Technical Data
TowiTek Long Range RFID Reader
dimensions : 240 x 240 x 35 mm
connection cable: fixed, 6 pin, 2 m
supply voltage: 12-15V C =
current consumption: less than 200mA
Interfaces: Wiegand 42 / RS-485 9600/8N1
allowed ambient temperature: 0°C .... 40°C
operating frequency: 125kHz
compatible RFI transponders: TowiTek transponder and
EM410x comp. 64/40Bit ROM
Disposal after end of using life for this product
Electronic devices of all kinds must not be disposed thru regular
household waste disposal but should be turned in to a collection
point for proper recycling. lease check with your local
requirements.
Limited Warranty
This product was designed and manufactured with great care and comes with a
warranty against material or manufacturing defects at time of purchase. This
warranty is valid for 24 months starting with the day of purchase and can be claimed
with original sales receipt. The warraty of TowiTek is limited to cost free repairing or
replacement of the defective unit. Expenses and risk of transportation; compensation
for installation and de-installation and all other expenses which may be related to the
repair or exchange of this product are not refunded by TowiTek. The liability for
consequential damages resulting from the use of this product – no matter of which
exact kind – is generally ruled out.
TowiTek
Long Range RFID
Reader
Nr. 19 15 27
User Manual
www.conrad.com
Thank you for purchasing this product of TowiTek!
This user guide contains many important instructions on
safe and proper use of this product. The purpose of this
user guide is to make sure you always will get best
performance andan reliable operation of your new product.
LEASE FULLY READ THIS USER GUIDE!
The handling of products operating with electric current requires you to
follow the rules from V E such as V E 0100, V E0550/0551, V E 0700,
V E 0711 and V E 0860 or other local rules in your country.
•
TowiTek modules are not designed and authorized for use in life support
or life saving applications! o not use the product for applications in
which a temporary or permanent failure or malfunction could cause
damage to persons or propery.
•
If the module is used to switch currents greater 24V it is necessary to
have the installation done with no voltage applied and performed by a
trained professional authorized for such work. The module may only be
used in such application if it was installed in a safe to touch enclosure.
•
The module must only be used in dry and clean environment. The use
near water, heavy dirt and/or high humidity is dangerous and not
permitted.
•
The product must not be used in conjunction with any type of flammable
liquid or gas or other environment with risk of spark triggered
explosions.
•
Never exceed the limits or ratings listed in the 'Technical ata' section at
the end of this user guide.
•
If the module is used in schools or educational facilities or similar
institutions the operation must be supervised by trained and authorized
staff.
•
The product itself and all parts thereof (including packing material) are
not suitable toys for childern! (choking hazard, risk of electric shock, ...)
Intended use for this product
The TowiTek Long Range RFI Reader operating on 125kHz is designed
to read the I information from RFI tags and transmit this data to an
connected access control system.
The unit is equipped with two data interfaces
• Wiegand 42-Bit interface
• RS-485 serial interface operating with 9600bps / 8N1
connection wire assignment
The 6-wire interface cable uses this color coding for the signals:
red power supply +12-15V C
black power supply 0V ( ata - GN )
green Wiegand42 Interface 'WG0'
white Wiegand42 Interface 'WG1'
blue RS-485 Interface 'A'
yellow RS-485 Interface 'B'
ower supply requirements
The power supply voltage needs to be stabilized and there must be no
high frequency noise (ripple voltage) since this could significantly reduce
the obtained reading range.
Data format on the Wiegand 42 interface
On the Wiegand 42 interface a sequence of 42 pulses (bits) is transmitted
on the 'WG0' and 'WG1' lines
Both output signals are open collector type. The connected access control
terminal will pull up the lines to +5-12V level in quiet state.
For a complete I -code transmission 42 negative pulses with a duration of
100µs each and delay of 2 mS between consecutive pulses are sent.
epending a logic '0' or '1' the pulses are transmitted on the 'WG0' or
'WG1' line.
The I -code of the transponder is 40Bit and two parity bits are added for
validation of the transmission. The transmission starts with an added
'even' parity bit for the first 20 data bits and ends with added 'odd' parity bit
calculated from the later 20 data bits.
E (b0 ................ b19) (b20 ................ b39) O
Example:
1 0101 1101 0001 1010 0010 0001 0100 0110 0011 1100 1
The parity bits are calculated for the first 21 bits of the transmission
always having a even number of ones while the last 21 bits will always
have a odd number of ones.
Data format on the RS-485 interface
The data output on the RS-485 interface will start immediately after the
transmission on the Wiegand interface is completed.
The 40 bit of the I -code are send as 5 consecutive bytes without any
additional packet framing, header or checksum added.
The transmission speed is 9600 bps (104µS per bit). The transmission
uses 8 data bits, one start bit and one stop bit (8N1).
Mounting instructions
The RFI reader can be mounted to an even surface using the 4 holes in
the corners.
The antenna must be installed on a non-metallic surface since metal
objects will degrade the reading performance of the Antenna significantly.
The manuals and documentation for our products is constantly improved
and translations to other foreign languages may become available.
Please make sure to check for the latest versions at www.conrad.com
FIN MORE PRO UCTS FROM
AVAILABLE AT
www.conrad.com
19 15 27 ENG - REV 1.00 / 12.08
EU-Declaration of conformity
The company
TowiTek HK Ltd.
ROOM 1613, 16/F.
TAI YAU BUILDING
181 JOHNSTON ROAD
WANCHAI, HONG KONG
declares in their own responsibility that the product
Long Range RFID Reader BN 19 15 27
complies to the standards
EN 55022 (EMV emission)
EN 61000-6-1 (EMV tolerance)
The above named company keeps records
with confirm the compliance to the standards
Liu Hong Quan Shenzhen 15-12-2008
(managing director)

Other Conrad Barcode Reader manuals

Conrad LS3600J User manual

Conrad

Conrad LS3600J User manual

Conrad 401264 User manual

Conrad

Conrad 401264 User manual

Conrad SUNTOP 1D BT-10RTW Firmware update

Conrad

Conrad SUNTOP 1D BT-10RTW Firmware update

Conrad Scanbuddy GS-X3 User manual

Conrad

Conrad Scanbuddy GS-X3 User manual

Conrad RIOTEC FS5027L User manual

Conrad

Conrad RIOTEC FS5027L User manual

Conrad iDC9602A User manual

Conrad

Conrad iDC9602A User manual

Conrad RIOTEC iDC9607A User manual

Conrad

Conrad RIOTEC iDC9607A User manual

Conrad 401264 User manual

Conrad

Conrad 401264 User manual

Conrad LS6300E User manual

Conrad

Conrad LS6300E User manual

Popular Barcode Reader manuals by other brands

Opticon 25-WEDGE-04 user manual

Opticon

Opticon 25-WEDGE-04 user manual

Marson MT 1097 quick guide

Marson

Marson MT 1097 quick guide

HP 9200C - Digital Sender Getting started guide

HP

HP 9200C - Digital Sender Getting started guide

FujiFilm JADAK flexpoint HS-1M user guide

FujiFilm

FujiFilm JADAK flexpoint HS-1M user guide

Tysso BCP-5500 Series user manual

Tysso

Tysso BCP-5500 Series user manual

Penpower WorldPenScan Series user manual

Penpower

Penpower WorldPenScan Series user manual

Honeywell Fusion MS3780 Setup/Service Instructions

Honeywell

Honeywell Fusion MS3780 Setup/Service Instructions

Toshiba B-SV4T Safety precautions

Toshiba

Toshiba B-SV4T Safety precautions

Kroy K6200 Series user manual

Kroy

Kroy K6200 Series user manual

HDWR HD-S80 instructions

HDWR

HDWR HD-S80 instructions

RIOTEC iLS6303ABQ Programming Quick Guide

RIOTEC

RIOTEC iLS6303ABQ Programming Quick Guide

Avery Dennison Monarch Pathfinder Ultra System administrator guide

Avery Dennison

Avery Dennison Monarch Pathfinder Ultra System administrator guide

KoamTac KDC180 quick guide

KoamTac

KoamTac KDC180 quick guide

Di-soric ID-100 Configuration guide

Di-soric

Di-soric ID-100 Configuration guide

Leuze electronic BCL 900i Series manual

Leuze electronic

Leuze electronic BCL 900i Series manual

Scantech Vega V-1010BT user manual

Scantech

Scantech Vega V-1010BT user manual

Hand Held Products IMAGETEAM 3800i Application note

Hand Held Products

Hand Held Products IMAGETEAM 3800i Application note

Ticode TI4145 quick guide

Ticode

Ticode TI4145 quick guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.