Contemporary Controls CTRLink EISX9-100T User manual

Manufacturer’s Declaration of April 1, 2003: I declare that the EISX9-
100T conforms to the above directives and standards.
George M. Thomas, President TD020800-0IA
EISX9-100T
Industrial Ethernet 10/100 Mbps Miniature Switching Hub
Installation Guide
The EISX9-100T segments the Ethernet LAN into nine collision domains. It
acts as a “bridge” between data links—creating a larger network diameter
than possible with repeating hubs. Each port automatically negotiates its
data rate to 10 Mbps or 100 Mbps and controls data flow with the PAUSE
function in full-duplex or the backpressure method in half-duplex.
The switch provides preamble regeneration with symmetry and amplitude
compensation—retiming signals to eliminate jitter. Digital pre-emphasis
compensates for inherent signal strength roll-off. Link integrity is monitored,
verifying that a working adapter or hub is on the distant end of a segment.
The switch learns port assignments by reading Ethernet frames and logs
source addresses on a table which can hold over 4000 addresses. With this
information, it improves throughput by restricting traffic to only those ports
party to a data exchange—while other data is simultaneously exchanged on
other ports. Store-and-forward operation is implemented and broadcast,
multicast, or unicast transmissions are received by all ports.
The switch has nine normal ports for attaching local devices. A special
uplink port (9X) allows cascading two hubs with no need of a crossover
cable. In addition to one power LED, each port has an LED which shows
link/activity/data rate.
The unit mounts on TS35 DIN-rail, can operate from a wide range of low-
voltage AC or DC power and offers redundant power connections.
Designed for Industrial Ethernet applications, the switch
complies with EMC immunity and emissions compatibility
standards for industrial environments.
INDUSTRIAL
CONTROL
EQUIPMENT
4EA4
Specifications
Electrical
INPUT DC AC
Voltage: 10-36 V 8-24 V
Power: 4 W 4 VA
Frequency: N/A 47-63 Hz
Temperature
Operating: –40°C to +75°C
Storage: –40°C to +85°C
Mounting
DIN-rail: TS35
Shipping Weight 1 lb (0.45 kg)
Regulatory Compliance
CE Mark
FCC Part 15, Class A
EN55022
EN55024
0Vdc
Input Ratings DC AC
Voltage
Power
Frequency
10-36 8-24
4W 4VA
N/A 47-63Hz
INDUSTRIAL
CONTROL
EQUIPMENT
4EA4
For Use In Class 2 Circuits
www.CTRLink.com
10Vdc36
8Vac24
EISX
PWR
1234 5678
1
2
3
4
56
78
X99
9
9mm
0.35”2.98”
76 mm
2.52”
64 mm
1.30”
33 mm
3.75”
95 mm
3.36”
85 mm
3.75”
95 mm
®
For use in Class 2 circuits.
Functional
Compliance: ANSI/IEEE 802.3
Data Rates: 10 and 100 Mbps
Signaling: 10BASE-T and
100BASE-TX
Connectors: Shielded RJ-45
Segment length: 100 m (max)
LED Indicators
Power green
Data Rate/Link green = 100 Mbps
yellow = 10 Mbps
Activity flashing
RJ-45 Connector Pin Assignments
Pin Function
1 TD+
2 TD–
3 RD+
6 RD–
(All other pins are unused.)
Mechanical
Power Options
12345678
Specifications
Electrical
INPUT DC AC
Voltage: 10-36 V 8-24 V
Power: 4 W 4 VA
Frequency: N/A 47-63 Hz
Temperature
Operating: –40°C to +75°C
Storage: –40°C to +85°C
Mounting
DIN-rail: TS35
Shipping Weight 1 lb (0.45 kg)
Regulatory Compliance
CE Mark
FCC Part 15, Class A
EN55022
EN55024
0Vdc
Input Ratings DC AC
Voltage
Power
Frequency
10-36 8-24
4W 4VA
N/A 47-63Hz
INDUSTRIAL
CONTROL
EQUIPMENT
4EA4
For Use In Class 2 Circuits
www.CTRLink.com
10Vdc36
8Vac24
EISX
PWR
1234 5678
1
2
3
4
56
78
X99
9
9mm
0.35”2.98”
76 mm
2.52”
64 mm
1.30”
33 mm
3.75”
95 mm
3.36”
85 mm
3.75”
95 mm
®
For use in Class 2 circuits.
Functional
Compliance: ANSI/IEEE 802.3
Data Rates: 10 and 100 Mbps
Signaling: 10BASE-T and
100BASE-TX
Connectors: Shielded RJ-45
Segment length: 100 m (max)
LED Indicators
Power green
Data Rate/Link green = 100 Mbps
yellow = 10 Mbps
Activity flashing
RJ-45 Connector Pin Assignments
Pin Function
1 TD+
2 TD–
3 RD+
6 RD–
(All other pins are unused.)
Mechanical
Power Options
12345678
0Vdc
Input Ratings DC AC
Voltage
Power
Frequency
10-36 8-24
4W 4VA
N/A 47-63Hz
INDUSTRIAL
CONTROL
EQUIPMENT
4EA4
For Use In Class 2 Circuits
www.CTRLink.com
10Vdc36
8Vac24
EISX
PWR
1234 5678
1
2
3
4
56
78
X99
9
9mm
0.35”2.98”
76 mm
2.52”
64 mm
1.30”
33 mm
3.75”
95 mm
3.36”
85 mm
3.75”
95 mm
®
Specifications
Electrical
INPUT DC AC
Voltage: 10-36 V 8-24 V
Power: 4 W 4 VA
Frequency: N/A 47-63 Hz
Temperature
Operating: –40°C to +75°C
Storage: –40°C to +85°C
Mounting
DIN-rail: TS35
Shipping Weight 1 lb (0.45 kg)
Regulatory Compliance
CE Mark
FCC Part 15, Class A
EN55022
EN55024
For use in Class 2 circuits.
Functional
Compliance: ANSI/IEEE 802.3
Data Rates: 10 and 100 Mbps
Signaling: 10BASE-T and
100BASE-TX
Connectors: Shielded RJ-45
Segment length: 100 m (max)
LED Indicators
Power green
Data Rate/Link green = 100 Mbps
yellow = 10 Mbps
Activity flashing
RJ-45 Connector Pin Assignments
Pin Function
1 TD+
2 TD–
3 RD+
6 RD–
(All other pins are unused.)
Mechanical
Power Options Power Considerations
Voltage in the range of 10–36 VDC or 8–24 VAC
must deliver current commensurate with 4-watt
power consumption. Conductors should be sized
accordingly. Zero volts and the chassis are isolated
from each other. Input connections are reverse-
polarity protected. Primary power backup is possible
via redundant diode-isolated inputs for a substitute
DC supply or backup battery, but separate provisions
are required for charging any backup battery.
LED Indicators
To aid troubleshooting, each port LED glows solid if
a link exists, flashes to show activity and shows
data rate by color: green for 100 Mbps and yellow
for 10 Mbps. One power LED is provided.
Network Connections
Only standard straight-through cables are needed
to connect to NIMs or another hub. Eight “normal”
ports make the crossover function internally for
attaching local devices. Port 9 can provide another
local drop via its “normal” jack or allow hub-to-hub
cabling via straight-through cable if using its “uplink”
jack (marked “9X”) — but the two Port 9 options can
NOT be used simultaneously.
Uplink Ports vs. Normal Ports
The EISX9-100T can
be powered in various
ways as illustrated
below :
DC POWERED
0 Vdc
REDUNDANT DC POWERED
AC POWERED
AC POWERED WITH
GROUNDED SECONDARY
AC POWERED WITH
BATTERY BACKUP
0 Vdc
0 Vdc
0 Vdc
0 Vdc
12345678
NEED MORE HELP INSTALLING THIS PRODUCT?
More information can be found in the Technical Support part of our web site
at www.ccontrols.com. If contacting our office, ask for Technical Support.
WARRANTY
Contemporary Controls (CC) warrants this product to the original purchaser
for one year from the shipping date. If it fails to operate in compliance with
its specification during this period, CC will, at its option, repair or replace the
product at no charge. The customer is responsible for shipping the product;
CC assumes no responsibility for the product until received. This limited
warranty covers products only as delivered. If user modification damages
the product, repair or replacement are not covered. Damage from abuse,
accident, disaster, misuse, or incorrect installation are not covered. This
warranty in no way warrants suitability of the product for any specific
application. More warranty information can be found at www.ccontrols.com.
Warning: This is a Class A product. In a domestic environment this product may cause
radio interference in which case the user may be required to take adequate measures.
RETURNING PRODUCTS FOR REPAIR
Before returning a product for repair, contact the manufacturer (USA office)
or its representative (UK office) below for instructions on return procedure:
Contemporary Control Systems, Inc.
2431 Curtiss Street
Downers Grove, Illinois 60515 USA
Tel: +1-630-963-7070
Fax: +1-630-963-0109
E-mail: [email protected]
WWW: http://www.ccontrols.com
Contemporary Controls Ltd
Barclays Venture Centre
University of Warwick Science Park
Sir William Lyons Road
Coventry CV4 7EZ UK
Tel: +44 (0)24 7641 3786
Fax: +44 (0)24 7641 3923
E-mail: [email protected]
DECLARATION OF CONFORMITY
Applied Council Directives: EMC Directive 89/336/EEC as amended by
92/31/EEC & 93/68/EEC; General Product Safety Directive 92/59/EEC
Standards to which Conformity is Declared: EN 55022:1995 (CISPR22:
1993), Class B; EN 55024:1998 I.T.E. Immunity Characteristics
Manufacturer’s Declaration of April 1, 2003: I declare that the EISX9-
100T conforms to the above directives and standards.
George M. Thomas, President TD020800-0IA
EISX9-100T
Industrial Ethernet 10/100 Mbps Miniature Switching Hub
Installation Guide
The EISX9-100T segments the Ethernet LAN into nine collision domains. It
acts as a “bridge” between data links—creating a larger network diameter
than possible with repeating hubs. Each port automatically negotiates its
data rate to 10 Mbps or 100 Mbps and controls data flow with the PAUSE
function in full-duplex or the backpressure method in half-duplex.
The switch provides preamble regeneration with symmetry and amplitude
compensation—retiming signals to eliminate jitter. Digital pre-emphasis
compensates for inherent signal strength roll-off. Link integrity is monitored,
verifying that a working adapter or hub is on the distant end of a segment.
The switch learns port assignments by reading Ethernet frames and logs
source addresses on a table which can hold over 4000 addresses. With this
information, it improves throughput by restricting traffic to only those ports
party to a data exchange—while other data is simultaneously exchanged on
other ports. Store-and-forward operation is implemented and broadcast,
multicast, or unicast transmissions are received by all ports.
The switch has nine normal ports for attaching local devices. A special
uplink port (9X) allows cascading two hubs with no need of a crossover
cable. In addition to one power LED, each port has an LED which shows
link/activity/data rate.
The unit mounts on TS35 DIN-rail, can operate from a wide range of low-
voltage AC or DC power and offers redundant power connections.
Designed for Industrial Ethernet applications, the switch
complies with EMC immunity and emissions compatibility
standards for industrial environments.
ts.
INDUSTRIAL
CONTROL
EQUIPMENT
4EA4

Other Contemporary Controls Switch manuals

Contemporary Controls EISK5-100T/F Series User manual

Contemporary Controls

Contemporary Controls EISK5-100T/F Series User manual

Contemporary Controls EISW8-100T User manual

Contemporary Controls

Contemporary Controls EISW8-100T User manual

Contemporary Controls CTRLink EIDX MP Series User manual

Contemporary Controls

Contemporary Controls CTRLink EIDX MP Series User manual

Contemporary Controls CTRLink EISK5-100T User manual

Contemporary Controls

Contemporary Controls CTRLink EISK5-100T User manual

Contemporary Controls CTRLink EIBA5-100T User manual

Contemporary Controls

Contemporary Controls CTRLink EIBA5-100T User manual

Contemporary Controls CTRLink EISK8-100T User manual

Contemporary Controls

Contemporary Controls CTRLink EISK8-100T User manual

Contemporary Controls CTRLink EISK8-GT/H User manual

Contemporary Controls

Contemporary Controls CTRLink EISK8-GT/H User manual

Contemporary Controls CTRLink EISK8M Series User manual

Contemporary Controls

Contemporary Controls CTRLink EISK8M Series User manual

Contemporary Controls CTRLink Skorpion Series User manual

Contemporary Controls

Contemporary Controls CTRLink Skorpion Series User manual

Contemporary Controls CTRLink EISC-100T User manual

Contemporary Controls

Contemporary Controls CTRLink EISC-100T User manual

Contemporary Controls EISW Series User manual

Contemporary Controls

Contemporary Controls EISW Series User manual

Contemporary Controls EISK5-100T/H User manual

Contemporary Controls

Contemporary Controls EISK5-100T/H User manual

Contemporary Controls CTRLink EISK8P-GT User manual

Contemporary Controls

Contemporary Controls CTRLink EISK8P-GT User manual

Contemporary Controls EISX8M series User manual

Contemporary Controls

Contemporary Controls EISX8M series User manual

Contemporary Controls EISK16-100T User manual

Contemporary Controls

Contemporary Controls EISK16-100T User manual

Contemporary Controls CTRLink EISK5-GT/H User manual

Contemporary Controls

Contemporary Controls CTRLink EISK5-GT/H User manual

Contemporary Controls EISK8-100T/F Series User manual

Contemporary Controls

Contemporary Controls EISK8-100T/F Series User manual

Contemporary Controls EISW5-100T User manual

Contemporary Controls

Contemporary Controls EISW5-100T User manual

Popular Switch manuals by other brands

Radial Engineering Tonebone JX-2 Switchbone user guide

Radial Engineering

Radial Engineering Tonebone JX-2 Switchbone user guide

hager SP 801 User instructions

hager

hager SP 801 User instructions

3Com OfficeConnect 3CDSG8 datasheet

3Com

3Com OfficeConnect 3CDSG8 datasheet

Kinesis FS007RJ11 user guide

Kinesis

Kinesis FS007RJ11 user guide

3Com CoreBuilder 9000 Quick installation guide

3Com

3Com CoreBuilder 9000 Quick installation guide

TP-Link TL-SG1008MP installation guide

TP-Link

TP-Link TL-SG1008MP installation guide

Moxa Technologies EtherDevice EDS-G205A-4POE-1GSFP-T Quick installation guide

Moxa Technologies

Moxa Technologies EtherDevice EDS-G205A-4POE-1GSFP-T Quick installation guide

Lindsay Broadband LB-1000-OSW user manual

Lindsay Broadband

Lindsay Broadband LB-1000-OSW user manual

Cleveland Controls AFS-951-1 manual

Cleveland Controls

Cleveland Controls AFS-951-1 manual

Key Digital KD-HDMI4X1 operating instructions

Key Digital

Key Digital KD-HDMI4X1 operating instructions

Comtrol ROCKETLINX ES8510 Quick installation guide

Comtrol

Comtrol ROCKETLINX ES8510 Quick installation guide

Transition Networks SM TAT4X Series quick start guide

Transition Networks

Transition Networks SM TAT4X Series quick start guide

IPGARD SA-DVN-8S quick start guide

IPGARD

IPGARD SA-DVN-8S quick start guide

Geo Cosy installation instructions

Geo

Geo Cosy installation instructions

EtherWAN EX26262F installation guide

EtherWAN

EtherWAN EX26262F installation guide

Guntermann & Drunck TradeSwitch4-USB Installation and operation

Guntermann & Drunck

Guntermann & Drunck TradeSwitch4-USB Installation and operation

NETGEAR GS308 installation guide

NETGEAR

NETGEAR GS308 installation guide

SMC Networks D-P3DW* Series Operation manual

SMC Networks

SMC Networks D-P3DW* Series Operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.