7
W415-0812 / D / 08.16.12
2.3 GENERAL INFORMATION
When the appliance is installed at elevations above 4,500ft, and in the absence
of specific recommendations from the local authority having jurisdiction, the
certified high altitude input rating shall be reduced at the rate of 4% for each ad-
ditional 1,000ft.
This appliance is approved for bathroom, bedroom and bed-sitting room
installations and is suitable for mobile home installation.
No external electricity (110 volts or 24 volts) is required for the gas system
operation. Expansion / contraction noises during heating up and cooling
down cycles are normal and are to be expected.
If utilizing one of Wolf Steel's trim or surround kits, follow the framing instructions and the finishing instructions,
for removal of the top extension.
NOTE: The protective wrap on plated parts is best removed when the assembly is at room temperature
but this can be improved if the assembly is warmed, using a hair dryer or similar heat source.
2.4 RATING PLATE INFORMATION
SERIAL NUMBER/
NO. DE SERIE: BGD40
W385-0656
CERTIFIED UNDER / HOMOLOGUE SELON LES NORMES:ANSI Z21.50b-2009 CSA2.22b-2009 VENTED GAS FIREPLACE / FOYERAU GAZAVEC EVACUATION
NOT FOR USE WITH SOLID FUEL. FOR USE WITH
COVERS AND GLASS DOOR CERTIFIED WITH THIS
UNIT ONLY.
WARNING: DO NOT ADD ANY MATERIAL TO THE APPLIANCE, WHICH WILL COME IN
CONTACT WITH THE FLAMES, OTHER THAN THAT SUPPLIED BY THE MANUFACTURER WITH
THE APPLIANCE.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS /
DEGAGEMENTS MINIMAUX DES MATERIAUX COMBUSTIBLES:
TOP, FLOOR, SIDES & BACK 0”
DESSUS, PLANCHER, COTES ETARRIERE
RECESSED DEPTH (CORNER INSTALLATION ONLY) 25 1/4”
PROFONDEUR D’ENCASTRE (INSTALLATION DU COIN SEULEMENT)
VENT / EVENT 1”
MANTEL HEIGHT / HAUTEUR DU MANTEAU 5”*
*MAXIMUM HORIZONTAL EXTENSION/L’EXTENSION HORIZONTALE MAXIMALE: 3”. SEE
INSTRUCTION MANUAL FOR GREATER EXTENSIONS. REFERER AU MANUEL
D’INSTRUCTION POUR DES EXTENSIONS PLUS GRANDES.
MINIMUM AND MAXIMUM HORIZONTAL VENT LENGTHSARE 10 INCHES AND 20 FEET
RESPECTIVELY. LES LONGUEURS HORIZONTALES MINIMALE ET MAXIMALE SONT 10
POUCES ET 20 PIEDS RESPECTIVEMENT.
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA
UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILISE
AVEC CET APPAREIL. UTILISER AVEC LES
COUVERTURES ET LES PORTES VITREES
HOMOLOGUEES SEULEMENT AVEC CETTE UNITE.
AVERTISSEMENT: N’AJOUTEZ PASA CETAPPAREILAUCUN MATERIAU DEVANT
ENTRER EN CONTACT AVEC LES FLAMMES AUTRE QUE CELUI QUI EST FOURNIAVEC CET
APPAREIL PAR LE FABRICANT.
THE APPLIANCE MUSTBE VENTED USING THE APPROPRIATE WOLF STEEL VENT KITS. SEE
OWNERS INSTALLATION MANUAL FOR VENTING SPECIFICS. PROPER REINSTALLATION AND
RESEALING IS NECESSARYAFTER SERVICING THE VENT-AIR INTAKE SYSTEM.
L’APPAREIL DOIT EVACUER SES GAZ EN UTILISANT L’ENSEMBLE D’EVACUATION PROPRE A
WOLF STEEL. REFERER AU MANUEL D’INSTALLATION DE PROPRIETAIRE POUR
L’EVACUATION PRECISE. IL EST IMPORTANT DE BIEN REINSTALLER L’EVENTAPRES AVOIR
ASSURE LE MAINTIEN DU SYSTME DE PRISE D’AIR.
ELECTRICAL RATING / CLASSIFICATION: 115V, 0.82 AMP, 60HZ
OPTIONAL FAN KIT / ENSEMBLE DE VENTILATEUR FACULTATIF: GZ-550KT
9700539 (WSL) 4001657 (NGZ)
4001658 (NAC) 4001659 (WUSA)
FOYER A GAZ VENTILE DIRECT. HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A
COUCHER, USE SALLE DE BAIN ET UN STUDIO. APPROPRIE POUR INSTALLATION
DANS UNE MAISON MOBILE SI SON INSTALLATION CONFROMEAUX EXIGENCES DE LA
NORME CAN/CSA Z240MH SERIE DE MAISONS MOBILES EQUIPEES AU GAZ, EN
VIGUEUR AU CANADA OU AUX ETATS-UNIS DE LA NORME DE SECURITE ET DE
CONSTRUCTION DE MAISONS MANUFACTUREES, TITRE 24 CFR, SECTION 3280.
DANS LE CAS OU CETTE NORME D’ETATS-UNIS NE PEUT ETRE APPLIQUEE, SE
REFERER A LA NORME RELATIVE AU CRITERE DE MESURES DE SECURITE CONTRE
L’INCENDIE POUR LES INSTALLATION DANS LES MAISONS MANUFACTURES, LES
SITES ET LES COMMUNAUTES, ANSI/NFPA 501A.
DIRECT VENT GAS FIREPLACE. APPROVED FOR BEDROOM, BATHROOM AND BED-SITTING
ROOM INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN
ACCORDANCE WITH THE CURRENT STANDARD CAN/CSA Z240MH SERIES GAS
EQUIPPED MOBILE HOMES, IN CANADA OR IN THE UNITED STATES THE
MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARD, TITLE 24 CFR,
PART 3280. WHEN THIS US STANDARD IS NOTAPPLICABLE USE THE STANDARD FOR
FIRE SAFETY CRITERIA FOR MANUFACTURED HOME INSTALLATIONS, SITES AND
COMMUNITIES, ANSI / NFPA501A.
BGD40GN BGD40N BCDV400N MODEL BGD40P BCDV400P BGD40GP
0-4500FT (0-1370m) ALTITUDE / ELEVATION 0-4500FT (0-1370m)
30,000 BTU/h INPUT /ALIMENTATION 30,000 BTU/h
20,000 BTU/hREDUCED INPUT / ALIMENTATION REDUITE 20,000 BTU/h
MANIFOLD PRESSURE: 3.5" WATER COLUMN MANIFOLD PRESSURE: 10" WATER COLUMN
PRESSION AU COLLECTEUR: 3.5" D'UNE COLONNE D'EAU PRESSION AU COLLECTEUR: 10" D'UNE COLONNE D'EAU
MINIMUM SUPPLY PRESSURE: 4.5" WATER COLUMN MINIMUM SUPPLY PRESSURE: 11" WATER COLUMN
PRESSION D'ALIMENTATION MINIMALE: 4.5" D'UNE COLONNE D'EAU PRESSION D'ALIMENTATION MINIMALE: 11" D'UNE COLONNE D'EAU
MAXIMUM SUPPLY PRESSURE: 7.0" WATER COLUMN MAXIMUM SUPPLY PRESSURE: 13" WATER COLUMN
PRESSION D'ALIMENTATION MAXIMALE: 7.0" D'UNE COLONNE D'EAU PRESSION D'ALIMENTATION MAXIMALE: 13" D'UNE COLONNE D'EAU
For rating plate location, see “INSTALLATION OVERVIEW” section.
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
NOTE: The rating plate must remain with the appliance at all times. It must not be removed.
NG LP
Altitude (FT) 0-4,500 0-4500
Max. Input (BTU/HR) 30,000 30,000
Max. Output Steady State (BTU/HR) 20,400 20,400
Min. Inlet Gas Supply Pressure 4.5" Water Column 11" Water Column
Max. Inlet Gas Supply Pressure 7" Water Column 13" Water Column
Manifold Pressure (Under Flow Conditions) 3.5" Water Column 10" Water Column
FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND
QUALITY!
PPLIANCE, WHICH WILL COME INWHICH WILL COME IN
PPLIED BY THE MANUFACTURER WITHPPLIED BY THE MANUFACTURER WIT
LLATION DU COIN SEULEMENT)LATION DU COIN SEULEMENT)
ENSION/L’EXTENSION HORIZONTALE M
NSION/L’EXTENSION HORIZONTALE
R GREATER EXTENSIONS. REFERER
REATER EXTENSIONS. REFERER
S EXTENSIONS PLUS GRANDES.
RIZONTAL VENT LENGTHS ARE
RS HORIZONTALES MINIMS HORIZONTALES MINI
001657
NGZ
001659
WUSA
N MOBILE SI SON INSMOBILE SI SON IN
SA Z240MH SERIE DE MA Z240MH SERIE DE
CANADA OU AUX ETATS-UNCANADA OU AUX ETATS-UN
CTION DE MAISONS MANUFACTUON DE MAISONS MANUFACTU
E CAS OU CETTE NORME D’ETATS-
RER A LA NORME RELATIVE AU CRITERME RELATIVE AU CRITE
CENDIE POUR LES INSTALLATION DS INSTALLATION D
0-4500FT (0-10-4500FT (0-
IMENTATION REDUITE 20,000 BMENTATION REDUITE 20,000
ANIFOLD PRESSURE:
PRESSION AU COLLECTRESSION AU COLLEC
E COLONNE D'EAUCOLONNE D'EA
66.8%
BCDV40