3
Step # 1: Set the dial micrometer to the setting as shown in the most current Continental Hydraulic Crimp Speciications Manual or via our
mobile app - CIQ for the combination of hose and itting being crimped.
Note: PC120M speciic row.
Step # 2: Select the correct die set for the combination of hose and itting being crimped.
Note: The correct die set can be found in the Continental Hydraulic Crimp Speciications Manual or via our mobile app - CIQ.
Step # 3: Install the die ingers individually one at a time into the crimper.
Note: Each die inger has a retaining pin where enters in the location hole in the master die. The die inger will click into place when it is
properly positioned.
Step # 4: Select the correct hose and fitting for your project.
Note: The correct combination of hose and itting being crimped can be found in the Continental Hydraulic Specifications Manual or via our
mobile app - CIQ.
Step # 5: Insert the hose assembly into the crimper, actuate the power unit (pneumatic pump, hand pump, or electric pump) continue to apply
pressure until the LED light indicator turn on to indicate that the crimp is complete. Release the pressure on the power unit to retract the dies
and remove the hose assembly.
Step # 6: Check the crimp diameter of the inished assembly with calipers or micrometers, to be certain that it is within the speciications as
outlined in the Continental Hydraulic Crimp Speciications Manual or via our mobile app - CIQ.
PC120M Crimping Procedure
PC120M Calibration Procedure
Step # 5 Step # 6Step # 4
Note: All settings are approximate, for minor adjustment adjust the dial micrometer as needed. If the crimp diameters are consistently too
tight or consistently too loose, follow the next steps to recalibrate the PC120M crimper.
Step # 1: To get an accurate calibration, make sure that the crimper’s head is fully open.
Step # 2: Set the dial micrometer at “0”.
Step # 1 Step # 2
Step # 2Step # 1 Step # 3