74.094.EU15
signs and symbols
- touch iqua-Touch - hand/object within sensor area
- water ows - LED ashes GREEN
- water ow stops - LED ashes RED
h - hours / min. - minutes / sec. - seconds
function procedure feedback
signal information default
setting
range
via iqua-
Touch
setting
range
via PC*
remove sticker +
1x app. 1 sec. till
+ 1x/sec., keep out of sensor area
wait till 1x
operation mode 1x >10 sec. (<10 Min.) water flows after leaving the sensor area
minimum =10 sec. - if <10 sec. no flushing - - -
minimum residence
time - - fixed, adjustable via PC* 10 sec. -3-30 sec.
ushing time
for normal operation
set / programm
1x app. 2 sec. till 1x extended function mode is active
7 sec. 2-30
sec.
0-3600
sec.
1x app. 5 sec. till 1x
1x 2 - 30 sec.
keep touched
+ 1x/sec. and water ows during touching -
releasing de nes ushing time
after releasing 1x con rmation, ready for operation
temporary off
«cleaning mode»
activate
1x app. 2 sec. till 1x extended function mode is active
15 min. - 0-3600
sec.
2x a app. 0,5 sec. pulsing during active function
temporary off
stop
1x app. 0,5 sec. 1x manual stop
automatic (preset time) 1x automatic after preset time
manual ush
activate
1x app. 2 sec. till 1x extended function mode is active
ush-
ing
time
see
ushing
time
see
ushing
time
1x minimum 3 sec.
(max. 5 sec.)
+ 1x/sec and water ow after releasing
manual ush
stop
1x app. 0,5 sec. manual stop
automatic (preset time) automatic after preset time
line purge feature
«automatic ush on
set intervall of non
usage»
-----------------------------
pre ush feature
activate / deactivate
1x app. 2 sec. till 1x extended function mode is active
off
----------
2 sec.
off
24 h
48 h
---------------
on/off
off
1-5000 h
---------------
1 - 3600
sec.
1x app. 25 sec. till 1x - 6x
purge pre ush purge pre ush
1x off off 4x off on
2x 24 h off 5x 24 h on
3x 48 h off 6x 48 h on
ignore ashes after 5 sec. and 10 sec. - keep
touched till 1x - 6x aftter app. 25 sec.,
releasing de nes interval
restart electronics
1x app. 2 sec. till 1x extended function mode is active
- - manually
2x a app. 0,5 sec. pulsing during active function
1x app. 5 sec. till 4x 1x/sec.
release and wait till + 1x/sec., keep out of sensor area
wait till 1x con rmation, ready for operation
sensor range
set / programm
1x app. 2 sec. till 1x extended function mode is active
61-8 steps manually
2x a app. 0,5 sec. pulsing
1x app. 15 sec. till 1x - 8x
1x = min. ...... 8x = max.
ignore ashes 4x after 5 sec., keep touched
till 1x - 8x after app. 15 sec., releasing
de nes sensor range step
release and wait till + 1x/sec., keep out of sensor area
wait till 1x con rmation, ready for operation
security feature >15 min. automatic sensor setting auto - -
empty battery 2x/sec. during dedecting hand / object auto - -
* With optional Service-Aadapter or wireless W-Combox and Service Monitor Software! Beside the mentioned functions the Service Monitor
Software offers additional possibilities for custom parameterization.
XXX
XXX
XXX
ouch
• electronic functions