Controlled Access HS400 Series User manual

HS400 Series Tandem Full Height Turnstile
Service & Installation Manual
Note: Successful turnstile installation depends on reading this manual.
Please keep this service manual after installation. If an installation is done by a construction company
or outside installer, please pass this book along to the end user. This book is required for maintenance,
troubleshooting & repairs.
Service Manual: 0740 E Gen. 3
ag.inc 888-552-9046
125 E. Stan125 E. Stansifer Ave Clarksville, IN 47129

Important Electrical Information
Installation of the control head mechanism into the turnstile requires a grounding-type outlet recep-
tacle installed inside of the frame or cabinet through the provided conduit access points.
To reduce the risk of electric shock, this equipment has a grounding type plug that has a third
(grounding) pin. This plug will only t into a grounding type outlet. If the plug does not t into the
outlet, contact a qualied electrician to install the proper outlet. Do not change this plug in any way.
Additionally, the P24-60W power supply from this appliance must be grounded to the frame of the
turnstile. Utilize the green colored grounding screw threaded into the grounding tab located near the
power supply along with the provided grounding wire from the power supply to ensure the equip-
ment is properly grounded.
Do not connect to a receptacle controlled by a switch.
UL 294 Classication Declarations:
Feature Level
Destructive Attack Test I
Line Security I
Endurance IV
Standby Power I
ULC S319, Class 1
Wiring methods shall be in accordance with:
National Electrical Code, ANSI/NFPA 70
Canadian Electrical Code, CSA C22.1, Part I, Safety Standard for Electrical Installations
The 6500 Series Control Head is suitable for indoor & outdoor use, within in an appropriate turnstile or
gate model.
HS400 Series Tandem Full Height Turnstile Service & Installation Manual
0740E Gen 3.
2
HS400 Series Tandem Full Height Turnstile Service & Installation Manual
0740E Gen 3.
2
ag.inc 888-552-9046
125 E. Stan125 E. Stansifer Ave Clarksville, IN 47129

Table of Contents
Important Electrical Information 2
HS400 Series Tandem Full Height Data Sheet 4
HS400 Series Tandem Full Height Components 6
HS400 Series Tandem Full Height Fastener List 7
Pre-Installation Tips 8
Wedge Type Concrete Anchor Instructions 10
Installation Instructions 11
6500 Series Control Head Mechanical Overview 18
Internal Parts Breakdown 19
Control Head Parts List 20
Control Head Congurations 21
Locking Bar Information 22
Hydraulic Shock & Indexing 24
Electrical Introduction 25
Wiring Diagram 26
Wiring Legend 27
Limit Switch & Limit Switch Cam Information 28
Logic Controller Settings 29
Testing Procedure 30
Maintenance & Cleaning 31
Troubleshooting 32
Proper Turnstile Usage 35
Warranty 36
Appendix
HS400 Series Tandem Full Height Turnstile Service & Installation Manual
0740E Gen 3.
3
ag.inc 888-552-9046
125 E. Stan125 E. Stansifer Ave Clarksville, IN 47129

The Leader in Pedestrian Access Control
0220
The High-Security Series HS427-T | HS430-T
Full-Height Turnstile (Tandem) | Interior & Exterior Application
Controlled Access manufactures the most
reliable full-height turnstiles available.
The High-Security Series units can be
engineered to meet all your security and
control requirements, and can be created as
stand-alone units, or as part of an integrated
system. Available in stainless steel (304 or
316), carbon steel with powder coating,
or hot-dipped galvanized nish. These
units can be tted for any application with
leading edge technology and features.
Controls and Interfaces:
• Biometric Integration
• Fail-Open or Fail-Secure Locking
• Card Readers
• Push-Button and Wireless Remotes
• Electronic/LCD Counters
• Manual Key Override – both directions
• Indicator Lights
Size Options:
(pedestrian clearance)
HS427-T: 27” (685.8mm)
HS430-T: 30” (762mm)
304 Stainless, No. 4 Satin
nish (shown)
Optional black or safety
orange end caps available.
Hot-dipped galvanized nish.
Also available in stainless
steel or power coated nishes.
Built in the USA
* Dimensions subject to change without notice. See CAD drawings on reverse side
WidthDepth
59.375”
(1508.1mm)
94.250”
(2394mm)
27”
(685.8mm)
84”
(2133.6mm)
91”
(2311.4mm)
62”
(1574.8mm)
102”
(2590.8mm)
30”
(762mm)
84”
(2133.6mm)
91”
(2311.4mm)
HS427-T
HS430-T
A*B*C*D*E*
Passage
Width
Passage
Height
Overall
Height
We’re the #1 Choice of Top Architects,
Security Pros and Engineers
For more than 30 years, Controlled Access has been the globally trusted
name in pedestrian control equipment. Made in Ohio and shipped
worldwide, we are the rst choice of leading architects, facility managers,
security consultants, and engineers. Whether your project requires high
security full-height turnstiles, waist high units, or matching ADA accessible
gates, Controlled Access is the secure choice. We’re experienced in
access control systems, from card readers to biometric scanning, to give
you the power to control access.
60%
Gloss
Black
60%
Gloss
White
RAL 1013
Oyster
White
RAL 5023
Distant
Blue
RAL 5010
Gentian
Blue
RAL 6002
Leaf
Green
RAL 8028
Terra
Brown
RAL 9007
Grey
Aluminum
Additional colors available and can be quoted upon request.
Standard powder coating color selections:
ag.inc 888-552-9046
125 E. Stan125 E. Stansifer Ave Clarksville, IN 47129

The Leader in Pedestrian Access Control
0220
The High-Security Series HS427-T | HS430-T
Full-Height Turnstile (Tandem) | Interior & Exterior Application
Available Finishes:
• Hot dipped galvanized carbon steel
• Carbon steel with powder coating
(standard color is black/ other colors available upon request)
• Our signature 304 stainless steel, No. 4 satin
nish, or 316 stainless
Operation Features
6500 Series Control Head:
• Auto-indexing (self-centering) with adjustable
hydraulic shock suppression
• Hardened tool steel locking bars, cam and
roller assemblies
• Permanently lubricated bearings
• Your choice of manual or electronic control on
both directions
• Nearly universal integration to any number of
access control systems
• Your choice on each electronic direction of
locking or unlocking on power failure
Options:
• Card reader mounting plates
• Daylight visible indicator lights
• Bi-directional key overrides
• Lockout bar (padlock not included)
• Decorative arm caps
• Stainless steel overhead full canopy
• Half canopy (covers passageway)
• 8 digit key resettable LCD counter with seven
year lithium battery
• Cold weather package, including thermostat
controlled heater and insulated mainframe
• Push button and wireless remotes
• Heel guard arm covers
• Additional options available upon request
Warranty:
Units are warranted against defects in materials
and workmanship for a period of one year from
date of delivery. See warranty information for
specic details.
Matching Swing Gate available:
(see model HS336 and model HS348 Manual
Passage Gate information)
* Dimensions are approximate based on chart on reverse side
Electrical Specications:
(per rotor)
Input Voltage: 100-240 VAC
Input Current: 1.3 - .55 A
Frequency: 50/60 Hz
Storage Temperature: -40 to 158°F
Operating Temperature: -4 to 131°F
(Cold weather package available)
Operating Voltage: 24VDC
Operating Current: 1.2 A (typical)
Standards and Codes:
Austenitic stainless steel:
ASTM A240, A249, A276
Hot rolled steel:
AISI C-1020, AISI C-1018
Hot dipped galvanizing:
ASTM A-143, ASTM A-153-80
All fasteners provided meet IFI ANSI/
ASME Fastener Standards
American Welding Society (AWS)
Standard D 1.1
The 6500 Series Control Head
is certied to confor to the
following standards
UL 294, UL 325, UL Subject 2593,
CAN/ULC S319 & CSA C22.2#247
4008027
HS336 - Back
(stainless steel
with optional
mesh push bar)
ontrolled ccess, Inc. is certied
by Advantage International Registrar
to be an ISO 9001:2015 company
* Dimensions are subject to change without notice
Applications:
Ideal for controlling orderly ow of foot trafc in
both indoor and outdoor settings
Design & Construction:
• Designed for secure operation with
aesthetics in mind
• Featuring fully welded exterior components
• Minimal exposed stainless steel hardware
• Heavy gauge materials meeting
ASTM standards
Dimensions:
HS427-T
• Pedestrian Clearance: 27” (685.8mm)
• Width: 94.250” (2394mm)
• Depth: 59.375” (1508.1mm)
HS430-T
• Pedestrian Clearance: 30” (762mm)
• Width: 102” (2590.8mm)
• Depth: 62” (1574.8mm)
Arm & Barrier Tubing Sizes
(HS427-T & HS430-T):
• Standard: 1 1/2” (38.1mm) diameter 14 gauge
• Optional: 1 3/4” (44.4mm) diameter 14 gauge
(16 gauge – Stainless Steel models)
All Models:
• Overall Exterior Height: 91” (2311.4mm)
• Passage Height: 84” (2133.6mm)
• Removal of Cover: Minimum of 4” needed
ag.inc 888-552-9046
125 E. Stan125 E. Stansifer Ave Clarksville, IN 47129

Each HS400 Series tandem full height turnstile comes with the following components:
HS400 Series Tandem Full Height Components
1x Main Channel
Wrapped in foam & cardboard to protect the cover’s nish.
Not Shown: Fastener Kit, Optional Components
I1
AB OKESC
I2 IB IC ID IE
+
+
–
–
01 02 03 04
XD10
+–
+–
LN
VOut
PS24-60W
2x 6500 Series Control Heads
Precongured as ordered, appearances may vary.
1x ABBC Barrier1x AABB Barrier1x A Rotor 1x B Rotor
Lowest arm nearly ush
with bottom
Lowest arm recessed several
inches from bottom
Standing upright and facing
forward, lowest arm is
to the left.
Standing upright and facing
forward, lowest arm is
to the right.
4x Yoke Assemblies
Quantity of poles varies between model sizes.
HS400 Series Tandem Full Height Turnstile Service & Installation Manual
0740E Gen 3.
6
ag.inc 888-552-9046
125 E. Stan125 E. Stansifer Ave Clarksville, IN 47129

High Security Series Tandem Full Height Turnstile Fasteners
Qty 12 - 3/8“-16 x 3” carriage bolts with waxed grade 316 serrated ange nuts
For mounting the cross arms to the main channel
Qty 8 - 3/8”-16 x 2” carriage bolts with waxed grade 316 serrated ange nuts
For mounting the control head to the mainframe
Qty 8 - 3/8“-16 x 2” carriage bolts with waxed grade 316 serrated ange nuts
For mounting the four yoke assemblies to the cross arms
Qty 6 - 3/8“-16 x 2” carriage bolts with waxed grade 316 serrated ange nuts
For mounting the barriers to the cross arms
Qty 14- 3/8“-16 x 3.75” wedge type concrete anchors with nuts and washers
For mounting yoke assemblies and barrier assembles to concrete
Qty 2 - 5/8”-11 x 4.5“ wedge type concrete anchors with nuts, bearing blocks
and greased roller bearings
For the rotor bearing assemblies to the concrete
Qty 8 - 2” x 2“ square ribbed black plugs
For decorative plugging of the ends of the yoke cross arms
Qty 2 - 2” x 4” rectangle ribbed black plugs
For decorative plugging of the ends of the barrier cross arm
All High Security Series Full Height Tandem Turnstiles
Note: HS427 & HS430 models share a universal fastener kit.
If some bolts seem like they are too long, this is the reason.
Properly assembled, they will not be visible.
Some options (such as canopies) may alter fastener requirements.
Fun fact: the threads on stainless steel fasteners have a tendency to malform and bind under some
circumstances. This is known as galling and can make life very inconvenient. Galling can cause the
threads to fuse together with friction welding, making the nuts impossible to remove. Fortunately,
there are some simple steps that can be taken to prevent it from occurring.
We are now providing grade 316 serrated ange nuts with all of our carriage bolts. The alternate
alloy used in the nut prevents the galling from occurring. Not only that, but this type of nut makes
it easier to install. Instead of fumbling around with a washer and lock washer, the serrated ange
nut uses friction to grip the surface it is touching with one part. It is proven to be more eective
than standard lock washers, which rely on spring tension for gripping. We are also coating these
nuts with carnauba wax for an additional layer of protection against galling.
HS400 Series Tandem Full Height Turnstile Service & Installation Manual
0740E Gen 3.
7
ag.inc 888-552-9046
125 E. Stan125 E. Stansifer Ave Clarksville, IN 47129

Tandem Full Height Pre-Installation Electrical Tips
If the unit is to be electronically controlled, pre-plan how it will be wired. We provide
several options for running conduit to each turnstile.
Each end of the main channel is designed to accept up to two 3/4” conduits, and also allow for multiple units to be bolted together.
The stationary barriers (which run vertically from the concrete to the mainframe) connects to the 2” x 4” cross arm with a 1.25”hole for
conduit races.
If equipped with optional card reader plates, the reader’s cabling goes through the back of the plate into the vertical yoke tube (drilling
required), into the long cross arm via a provided tting, and nally into the mainframe itself. Access control contacts to the controller
should be at least 18 gauge. A normally open contact closure is required for each direction (and if used, each directional override).
HS400 Series Tandem Full Height Turnstile Service & Installation Manual
0740E Gen 3.
8
ag.inc 888-552-9046
125 E. Stan125 E. Stansifer Ave Clarksville, IN 47129

Use in concrete ONLY. Not recommended for use in lightweight masonry such as block or brick.
Warning!
Always wear safety glasses and other necessary protective devices or apparel when installing or working with anchors.
Caution: Use of core drills is not recommended to drill holes for use with this anchor.
Do not use an impact wrench to set or tighten the anchor. Not recommended for use in concrete which has not had sucient time to cure.
The use of carbide drill bits manufactured with ANSI B212.15 drill bit diameter requirements is recommended for installation of this anchor.
Anchor spacing and edge distance (anchor installation locations) are the responsibility of the engineer of record.
Installing product in oversized holes is not recommended. Product will not set properly or achieve full designed load in oversized holes.
* Setting torque only applies at the time of installation.
4
Select a carbide drill bit with a diameter equal to the anchor diameter. Drill hole at least 1/4”deeper than nominal anchor embedment.
Clean hole with pressurized air or vacuum to remove any excess dust/debris.
Using the washer and nut provided, assemble the anchor, leaving nut one half turn from the end of anchor to protect threads. Drive
anchor through xture to be fastened until washer is ush to the surface of xture.
Expand anchor by tightening nut to the specied setting torque - see Table (approx 3 to 5 full revolutions).
Wedge Type Concrete Anchor Instructions
HS400 Series Tandem Full Height Turnstile Service & Installation Manual
0740E Gen 3.
9
ag.inc 888-552-9046
125 E. Stan125 E. Stansifer Ave Clarksville, IN 47129

Installation Instructions
1.) If needed, pour a level concrete pad at least 4”thick and 4” greater than the unit’s
length and width in each direction. Model specic diagrams are available if needed.
2.) Unpack turnstile(s) and verify all parts are included. Use the parts checklist in the
beginning of this book.
3.) Unwrap the main channel from the cardboard & foam packaging. Remove the 9x
10/32 anged button head cap screws and lift the cover o.
4.) Remove the cross arms from inside of the main channel and identify the dierent
sides to the cross arms. Note that optional canopies can aect the cross arms. See
canopy diagram provided with option for proper assembly technique in that instance.
Upper View (4x Holes)
Touching the main channel
Under View (4x Holes)
Facing the oor
Center holes may be large or small depending on model.
Short Yoke Cross Arms
Has holes on two sides. Length varies by model.
Upper View (5x Holes)
Touching the main channel
Under View (4x Holes)
Facing the oor
Side View (2x Holes)
Facing in towards center
Long Yoke Cross Arms
Has holes on three sides. Length varies by model.
Barrier Cross Arm
Has holes on two sides. Length varies by model.
Upper View (4x Small Holes, 7x Large Holes)
Touching the main channel
Under View (10x Small Holes, 2x Large Holes)
Facing the oor
HS400 Series Tandem Full Height Turnstile Service & Installation Manual
0740E Gen 3.
10
ag.inc 888-552-9046
125 E. Stan125 E. Stansifer Ave Clarksville, IN 47129

Installation Instructions (continued)
5.) Assemble cross arms to mainframe using the provided 3/8”x 3” carriage bolts as
illustrated below. Ensure cross arms are square to mainframe and that the cross arms
are ipped the correct way before attaching. Note that the carriage bolts have square
heads and may need to be hammered into the round holes of the cross arms.
6.) Utilizing the assembled mainframe, mark holes on the ground for the 14x 3/8”
concrete anchors to each of the marked holes below.
Upper View
Side hole on
long cross arm
Side hole on
long cross arm
Side hole on
long cross arm
Side hole on
long cross arm
Under View
Side hole on
long cross arm
Side hole on
long cross arm
Side hole on
long cross arm
Side hole on
long cross arm
HS400 Series Tandem Full Height Turnstile Service & Installation Manual
0740E Gen 3.
11
ag.inc 888-552-9046
125 E. Stan125 E. Stansifer Ave Clarksville, IN 47129

Installation Instructions (continued)
7.) Following the concrete anchor installation directions, drill each of the marked holes
marked for the 3/8”anchors. Be sure to remove debris from holes before installing the
anchors.
8.) Install the curved yoke assemblies onto the concrete over the anchors. Take special
notice of the two screws and extra hole on one side of the yoke strap. These screws and
holes are for card reader mounting plates and should be facing outward when bolting
down.
Screws & hole
on one end
of the strap.
Each yoke assembly has two
button head cap screws and a
larger hole in the center strap.
Take notice of this for the next
step.
Screws & Hole Screws & Hole
Screws & HoleScrews & Hole
HS400 Series Tandem Full Height Turnstile Service & Installation Manual
0740E Gen 3.
12
ag.inc 888-552-9046
125 E. Stan125 E. Stansifer Ave Clarksville, IN 47129

Installation Instructions (continued)
9.) Install vertical barrier assemblies over the anchors onto the concrete as shown below.
The concept is that the left side of the tandem will have one set of arms from each
barrier that are raised while the right side will have arms that are lower.
10.) If ordered with optional card reader mounting enclosures, remove the plastic
plugs from the side holes of the long cross arm and install the elbow tting
(packaged with enclosures in control head box) by placing the threaded chase
nipples inside of the box tubing and spinning the ttings into place. The ttings
need to be pointing downward to the ground when complete.
ABBC BarrierAABB Barrier AABB Barrier
ABBC Barrier
HS400 Series Tandem Full Height Turnstile Service & Installation Manual
0740E Gen 3.
13
ag.inc 888-552-9046
125 E. Stan125 E. Stansifer Ave Clarksville, IN 47129

Installation Instructions (continued)
11.) Place assembled mainframe on top of yokes and stationary barriers. Attach
barriers and yokes to cross arms by using the provided 14x 2”carriage bolts and
serrated flange nuts. A 9/16“ deep wall socket will be required for this step.
Unless ordered with optional canopy or yoke guards, insert black plastic plugs
into the 1.125”holes to keep water from entering the cross arms when nished.
If ordered with optional card reader mounting enclosures, the ttings previously
installed will insert into top of the yoke assembly for easy wire pickup from the
plate below.
HS400 Series Tandem Full Height Turnstile Service & Installation Manual
0740E Gen 3.
14
ag.inc 888-552-9046
125 E. Stan125 E. Stansifer Ave Clarksville, IN 47129

Installation Instructions (continued)
Step 1 Step 2 Step 3 Step 4
12.) If necessary, level the mainframe by shimming from under the yokes and the
barrier. Once level, secure these components to the concrete by adding the nuts
to the anchors.
13.) Once level and secure, use a plumb-bob to nd the center for the rotors by
dropping it from the mainframe’s output holes. Mark the concrete for drilling in
these positions.
14.) Drill holes for 5/8”concrete anchors in the marked positions and remove dust.
Install concrete anchors, bearing blocks, greased roller bearings and nut as shown
below. There is no need for at washers on these components.
Drop Plumb Bob Here Drop Plumb Bob Here
HS400 Series Tandem Full Height Turnstile Service & Installation Manual
0740E Gen 3.
15
ag.inc 888-552-9046
125 E. Stan125 E. Stansifer Ave Clarksville, IN 47129

Installation Instructions (continued)
CRITICAL INSTALLATION STEP: Place rotors onto bearings and align them so that there is one set of arms
pointing to the center of the half-moon shaped yokes, meshed together with the arms of the stationary
barriers (unlike single full height turnstiles).
Failure to properly align the rotors can cause inconsistent operation and the possibility to become trapped
within the turnstile in some scenarios. If the rotors were installed incorrectly, the solution is to x the rotor
alignments. Do not adjust access control or logic controller settings to accommodate the improper
alignments.
Simply remove the four carriage bolts holding each of the 6500 Series Control Heads to the mainframe, pull
up on the control heads to remove them as assemblies, spin the rotors to the correct position, then reinstall
the control heads into the mainframe.
Correct Alignment Incorrect Alignment
Rotors should NOTtwo sets of
arms pointing to the outsides of the
half-moon yokes, with one set of arms
meshed together with the other rotor.
Rotors have one set of arms in
between two half-moon yokes in
home position. Arms are meshed with
stationary arms on the barriers (unlike
a single full height).
15.) Place rotor assemblies on the roller bearing assemblies. Rotor A will have the
lower set of arms (closer to the oor) while rotor B’s arms will be higher. When placed
properly, the arms should mesh through the arms on the stationary barriers.
16.) Utilizing the diagram below, align the rotors to the correct position. This step
is critical, and failure to properly align the rotors will result in operational issues.
A Rotor B Rotor
B RotorA Rotor
AABB Barrier
ABBC Barrier
HS400 Series Tandem Full Height Turnstile Service & Installation Manual
0740E Gen 3.
16
ag.inc 888-552-9046
125 E. Stan125 E. Stansifer Ave Clarksville, IN 47129

Installation Instructions (continued)
17.) Mount the two control heads to the mainframe using the provided 3/8-16
carriage bolts. Unless equipped with key overrides, it does not matter if the
springs are pointed to the left or the right. Be aware that the control heads
may be congured dierently from each other, refer to the labels on the control
head boxes for illustrations on how each control head has been congured.
18.) If required, refer to the wiring diagram & legend for connecting access control
to the turnstile.
19.) Refer to the hydraulic shock information to properly adjust the rotor’s rotation.
Ideally, the rotor should rotate to the home position, but do so without slamming.
This prevents wear and tear on the control head assembly.
20.) Using a grease gun, ll the roller bearing grease cavities by utilizing the grease
ttings located about 3/4”from the bottom of the rotors. In the factory, we use Mobil
Mobilgrease XHP 222 Special with Lithium Thickener, but a simple white lithium or
similar grease is suitable.
21.) Test the turnstile to ensure it is functioning properly, reinstall the cover on the
top of the unit once satised, and keep this book for future reference.
Tuck smaller half of cover under
larger half and over the main
channel, fasten into place.
Place larger half of cover onto
the main channel and fasten
it into place.
Main Channel Larger Main Cover Notched Cover Panel
HS400 Series Tandem Full Height Turnstile Service & Installation Manual
0740E Gen 3.
17
ag.inc 888-552-9046
125 E. Stan125 E. Stansifer Ave Clarksville, IN 47129

6500 Series Control Head Mechanical Information
All of our turnstiles and ADA gates operate with a mechanism called the 6500 Series Control Head.
This sturdy and easy to maintain drive for the turnstile has replaced all previous model control heads.
It is adaptable to nearly any existing turnstile and comes with each new turnstile purchase. This control
head can be congured in multiple ways to accommodate the security requirements of each individual
job site.
An internal view of an electronically controlled two way 6500 series control head.
While the head can be congured for mechanical (no electronics) operation, a turnstile’s security
potential is reached in the case of an electronic two way control head. In this instance, each rotational
direction is independently unlocked. Congured properly, a control head will allow for one rotation
per valid entry request. Our anti-backup cams are designed so that it is mechanically impossible to
become trapped within the turnstile when properly installed.
Each control head comes precongured to your specic needs based oof a directional sheet that
is lled out before shipment. The heads are delivered pre-wired, tested and adjusted to our factory
recommendations. Installation is simple: connect inputs from access control devices into the logic
controller and plug the unit’s power supply into a 100-240 VAC (single phase) receptacle. The power
supply will automatically set itself to function on your local voltage and convert it to 24VDC.
HS400 Series Tandem Full Height Turnstile Service & Installation Manual
0740E Gen 3.
18
ag.inc 888-552-9046
125 E. Stan125 E. Stansifer Ave Clarksville, IN 47129

Phone: (800)942-0829
Fax: (800)942-0828
Web: www.controlledaccess.com
Email: sales@controlledaccess.com
Prices are subject to change without notice. Parts orders are shipped via FedEx. Shipping costs are not included. All parts orders under $500 require a credit card payment. Date: 04/01/2022
Complete control heads are
available upon request.
Contact us for pricing details.
Locking Bar Linkages
6519 - Fail Open
$12.26
6518 - Fail Lock
$12.26
Locking Bar Assemblies
0382 - Fail Open Assembly
$90.92
0383 - Fail Lock Assembly
$90.92
Limit Switch Cams
2267 - Standard $30.66
2268 - ADA $30.66
2269 - One-Way $30.66
Limit Switches
2180 - Standard
(Z-15GW2-B7-K) $22.68
1700 - One Way
(BZ2RW825-A2) $82.33
0372 - Top Casting
$219.65
0373 - Bottom Casting
$219.65
Control Head Castings
6532 - Index Pin
$132.69
Proximity Sensor & Accessories
7211 - 24VDC PNP Prox. Sensor
w/ M12 Connector (Sick 1040763)
$91.09
6589 - Turnstile Prox. Bracket
w/ 3x Mounts - LH, RH & Home
$11.19
0766 - 3 Branch M12 Splitter
$148.92
Shock Housing Assemblies
6535 - WH/427/430/T80/ADA
$189.18
6541 - 439/448/P60/HD
$198.68
Control Head Bearings
Indexing Springs
1106 - Waist High (Light) $6.51
1108 - Full Height (Heavy) $6.51
1107 - ADA (Extra Heavy) $6.51
Solenoid Springs
6510 - Fail Open Spring
$9.02
6016 - Fail Lock Spring
$9.02
6051 - Solenoid
Deltrol D4A53717-82
$65.55
Hydraulic Shock Absorbers
6560 - WH/427/430/T80/ADA
$190.75
6561 - 439/448/P60/HD
$346.47
0381 - Locking Bar Casting
w/ Oil Impregnated Bushings
$43.76
6520 - Index Pin Tubing
$32.99
0740 - Logic Controller (XD10)
$281.34
1641 - 1” ID for HS-22/439/448/P60
/RD70/Pre 2018 Top Castings
(1641-2RSNR) $7.39
7208 - Bottom casting on all models
(6007RSNR) $6.14
1640 - 7/8” ID for WH/ADA/T80 and
7/8” hex cams sold after 2018
(1640-2RSNR) $5.89
0751 - 24VDC Power Supply (60 W)
w/ NEMA 5-15 Drop Cord
$183.85
I1
A B OKESC
I2 IB IC ID IE
+
+
–
–
01 02 03 04
XD10
ML60
Power Supply
24V 2.5A
MiniLine
AC 100-240V
+ -+ -
N L
DC on
24-28V
Cam Assemblies
0401 - T80/WH/Legacy 427/430
(7/8 Hex Shaft) $264.26
0407 - P60 & RD70 Models
(1.25" Hex, Long) $291.95
0402 - ADA w/ Arm Adaptor $264.26
0416 - ADA w/ Chain Drive
0415 - All HS-22 Models/439/448/HD
(1.25" Hex, Short) $278.26
$278.26
ag.inc 888-552-9046
125 E. Stan125 E. Stansifer Ave Clarksville, IN 47129
This manual suits for next models
2
Table of contents
Other Controlled Access Turnstile manuals
Popular Turnstile manuals by other brands

EMIT
EMIT SmartLog Pro 50723 Installation, operation and maintenance

PERCo
PERCo RTD-20 manual

Automatic Systems
Automatic Systems SMARTLANE SL 90X Technical manual

Alvarado
Alvarado UltraQ-AMT installation instructions

Dormakaba
Dormakaba ALVARADO SUPERVISOR 5000 user guide

HZ Security
HZ Security HZ-SWBS04 installation manual