Magnetic MHTM FlowMotion mTripod User manual

Operating Instructions
Turnstile
MHTM™ FlowMotion®
mTripod
Doc. ID: 5817,0026EN
Version 02
58170026EN_02.indd 1 04.04.2019 16:08:57

2
mTripod
MAGNETIC AUTOCONTROL GMBH
Grienmatt 20
D-79650 Schopfheim
Germany
Phone +49 7622 695 5
Fax +49 7622 695 802
www.magnetic-access.com

3
mTripod
Contents
Contents
1 Notes on the document 7
1.1 Purpose and contents of this operating instructions 7
1.2 Read and store the operating instructions 7
1.3 Non-compliance with the operating instructions 8
1.4 Symbols and illustrations used in these operating instructions 8
1.4.1 Warning notes and notes 8
2 Safety 10
2.1 Intended use 10
2.2 Changes and modifications 10
2.3 Target groups 11
2.3.1 Operator and his responsibilities 11
2.3.2 Personnel - activities and qualifications 12
2.4 Personal protective equipment 13
2.5 Symbols on the device 14
2.6 For your safety 15
2.7 To protect the environment 16
2.8 Emergency opening of the pedestrian gate 16
3 Technical data 17
3.1 Dimensions and design 17
3.1.1 mTripod-ML 17
3.1.2 mTripod-MS 19
3.2 Clearances and line configuration to be maintained 20
3.3 Electrical connection 21
3.4 Operating conditions 21
3.5 Emissions 21
3.6 Control unit MGC 22
4 Design and function 23
4.1 Design 23
4.2 Function 24

4
mTripod
Contents
5 Receipt of goods, transport and storage 25
5.1 Goods receiving department 25
5.2 Safety during transport 25
5.3 Transport 26
5.4 Storage 27
6 Unpacking, scope of delivery and identification 28
6.1 Unpacking 28
6.2 Scope of delivery 29
6.3 Identification 30
6.3.1 Type plate 30
7 Installation and assembly 31
7.1 Safety during installation and assembly 31
7.2 Mounting options 32
7.3 Required steps 32
7.4 Setting up foundation and placing empty conduits 33
7.4.1 Requirements foundation 33
7.4.2 Requirements empty conduits 33
7.4.3 Setting up foundation and placing empty conduits 34
7.4.4 Foundation and empty conduit plan
and reinforcement mTripod FMTP-ML 35
7.4.5 Foundation and empty conduit plan
and reinforcement mTripod FMTP-MS 37
7.5 Base plate and drilling template mTripod FMTP-ML 39
7.6 Base plate and drilling template mTripod FMTP-MS 40
7.7 Aligning the pedestrian gate 41
7.8 Assembly of the mTripod 41
7.8.1 Mounting variant “Direct mounting” 41
7.8.2 Mounting option «Mount base plate» 44
7.8.3 Mounting variant “Glue base plate” 48
7.9 Assembling mTripod 52
7.10 Dismantling and mounting cover 58
7.11 Opening and closing the housing 60
7.12 Checking the assembly 61

5
mTripod
Contents
8 Electrical connection 62
8.1 Safety during electrical connection 62
8.2 Installing electrical protective devices 63
8.3 Connecting the mains cable 64
8.4 Connecting customer control lines 65
8.4.1 Connecting emergency opening contacts 66
8.5 Installing and connecting customer-access control devices 66
8.6 Checking the electrical connections 68
9 Commissioning 69
9.1 Safety during commissioning 69
9.2 Putting the pedestrian gate into operation 69
9.3 Switching the pedestrian gate on and off 69
9.4 Parameterising the pedestrian gate 71
10 Test book 71
11 Operation 72
12 Cleaning and maintenance 72
12.1 Cleaning the pedestrian gate 72
12.2 Maintenance schedule 73
13 Corrective action 73
14 Spare parts and repair 74
15 Customer service 74
16 Decommissioning 75
16.1 Safety during decommissioning 75
16.2 Decommissioning of the pedestrian gate 75
17 Disassembly and disposal 76
17.1 Safety during disassembly and disposal 76
17.2 Dismantling and disposing of the pedestrian gate 76
18 EU-Declaration of Conformity 77
Index 79

6
mTripod

7
mTripod
Notes on the document
1 Notes on the document
1.1 Purpose and contents of this operating instructions
These operating instructions provide all the information required for the
product in the various phases of its life cycle.
These operating instructions contains the following information: Assembly and
function, transport and storage, unpacking and delivery, installation and
assembly, electrical connection, commissioning, operation, cleaning and
maintenance, decommissioning, dismantling and disposal.
IMPORTANT!
For parameterisation see separate document “Description of
MGC control unit for mTripod (Doc.ID: 5817,0025)”.
1.2 Read and store the operating instructions
Pre-requisite for safe working is the observance of all specified safety notes,
warning notes and instructions. In addition, the local accident prevention
regulations, general safety regulations and local environmental regulations
applicable to the area of application of the product must be observed.
Carefully read these operating instructions before starting any work! The
operating instructions are a product component and must be kept in direct
proximity of the product, well accessible to the personnel at all times.
If the product is passed on to third parties, please also provide these operating
instructions.

8
mTripod
Notes on the document
1.3 Non-compliance with the operating instructions
Magnetic declines all liability for personal injury and material damage caused
by not observing the operating instructions.
This applies in particular to damage caused by:
› Non-intended use
› Use of non-qualified personnel
› Use of non-approved components
› Unauthorised modifications
› Inappropriate assembly and installation
› Improper operation
› Defective or unperformed maintenance and repairs
› Use of non-approved spare parts
› Operation of a faulty product
1.4 Symbols and illustrations used in these operating instructions
1.4.1 Warning notes and notes
Warning notes are characterised by pictograms in these operating instructions.
A warning note starts with a signal word that expresses the extent of the
hazard.
It is absolutely essential to observe the warning notes and to proceed with
caution in order to prevent accidents as well as bodily injuries and property
damage.
Warning Notes
DANGER
The signal word DANGER points to an immediately dangerous
situation, which leads to death or severe injuries if it is not
avoided.
WARNING
The signal word WARNING points to a potentially dangerous
situation, which can lead to death or severe injuries if it is not
avoided.

9
mTripod
Notes on the document
CAUTION
The signal word CAUTION points to a potentially dangerous
situation, which can lead to minor injuries if it is not avoided.
NOTICE
The signal word NOTICE points to a potentially harmful situation,
which leads to property damage if it is not avoided.
Notes and recommendations
IMPORTANT!
The signal word IMPORTANT highlights useful notes and
recommendations as well as information for an efficient and
trouble-free operation.

10
mTripod
Safety
2 Safety
2.1 Intended use
The Magnetic turnstile mTripod is designed for the control of persons who
wish to enter or leave a restricted area.
The turnstile is intended for passage of persons who can pass the turnstile
safely, speedily and without any help. Separate access options are provided for
persons who cannot pass the turnstile safely or without any help, e.g. small
children, the elderly or persons with impairments. Children under 14 years of
age may only pass through the turnstile under the supervision of an adult.
The turnstile may only be mounted on non-flammable floors.
The turnstile may only be operated within the temperature range indicated on
the type plate.
Misapplications
Any other or further use is considered improper use. Magnetic is not liable for
any resulting personal injury or damage to property.
For example, the following applications are considered to be contrary to
regulations:
› Unaccompanied use of the turnstile by children under 14 years of age.
› Use of the turnstile by persons who cannot pass the turnstile safely, quickly
or without assistance.
› Using the turnstile without an enabled passage. This means that the
blocking arms are forced to rotate.
› Mounting the turnstile on a flammable floor.
2.2 Changes and modifications
Changes or modifications to the product, attachments or components may
result in unforeseen hazards. Before making any technical changes or
modifications to the product of any of the components, written permission
must be obtained from Magnetic.

11
mTripod
Safety
2.3 Target groups
2.3.1 Operator and his responsibilities
The operator must comply with the statutory obligations regarding work safety.
In addition to the safety instructions and warning notes in these operating
instructions, the valid safety, accident prevention and environmental
protection regulations must be observed.
In particular, the operator must:
› determine additional danger in a danger analysis.
› implement the necessary behavioral requirements in work instructions for
operation with the product at the operating location.
› regularly verify throughout the product time of use that the work
instructions drawn up by him comply with the current state of the
regulations.
› adapt the work instructions to any new provisions, standards and usage
conditions - where required.
› clearly regulate the responsibilities for all work on the product and with the
product such as installation, commissioning, operation, cleaning,
maintenance, etc.
› that the personal protective equipment is worn.
› ensures that all employees who work with the product or on the product
have read and understood the operating instructions.
Furthermore, the operator must train personnel regarding the use of the
product at regular intervals and provide information on possible dangers.
Furthermore, the operator is responsible for:
› the product is always in perfect technical condition.
› the product is maintained at specified maintenance intervals
› the product is only operated within the permitted temperature range.
The operator is also responsible that the danger area of the product cannot be
accessed by any unauthorised persons under any circumstances.

12
mTripod
Safety
2.3.2 Personnel - activities and qualifications
Only authorised, trained and sufficiently qualified personnel may work on and
with the product. The personnel must know and understand the operating
instructions and the required operating instructions.
Designation Qualification
Transport equipment operator › Has professional experience as a transport equipment
operator or warehouse and transport worker.
› Has a valid driving licence for the required industrial
truck, e.g. forklift.
› Knows the necessary regulations.
› Can assess the work assigned to her/him, recognises
possible dangers and take suitable safety measures.
Technician › Has completed training as a plant mechanic, plant fitter,
assembly mechanic, assembly fitter or has a comparable
technical education.
› Has completed training as an electrical safety expert.
› Has additional knowledge and experience.
› Knows the associated technical terms and regulations.
› Can assess the work assigned to her/him, recognises
possible dangers and take suitable safety measures.
Magnetic MHTM™ FlowMotion®
service expert
› Meets all requirements of the technician.
› Trained and authorised by Magnetic.
Operator › Trained by the operator.
Table 1: Qualifications of personnel

13
mTripod
Safety
Action Transport
equipment
operator
Technician Magnetic
service expert
Operator
Transporting X X – –
Unpacking X X X –
Laying the foundation – X – –
Assembly – X X –
Electrically connect – X X –
Parameterise – X X –
Commissioning 1) – X X –
Operating – X X X
Cleaning – X X X
Waiting – X X –
Rectify faults – X X –
Repairing – X X –
Decommissioning – X X –
Disassemble – X X –
Dispose – X – –
1) According to the supplied test book MHTM™ FlowMotion® mTripod
Table 2: Activities and qualifications
2.4 Personal protective equipment
It is necessary to wear personal protective equipment when dealing with the
product so as to minimise health hazards.
Before carrying out any work, properly dress in the necessary protective
equipment such as work clothes, protective gloves and safety shoes and wear
during work.

14
mTripod
Safety
2.5 Symbols on the device
Warning of dangerous electrical voltage!
The warning sign indicates hazardous areas with dangerous
electrical voltage. Non-observance of the warning signs causes
severe injuries or death. The work to be carried out may only be
carried out by a qualified electrician or an electric safety expert.
This warning sign is fixed at the following point:
› At the terminals, under the cover.

15
mTripod
Safety
2.6 For your safety
Mortal danger by electric voltage!
Touching live parts can be lethal. Damaged insulation or
damaged parts may be fatal.
› If the insulation or any parts are damaged, switch off the
power supply at once and initiate repair.
› Only qualified electricians or electrical safety experts may
work on the electrical system.
› Switch off power supply and secure against re-activation
before performing any work. Test for absence of voltage.
› Perform electrical installation in accordance with the
applicable regulations.
› Install protective devices that are prescribed by national
regulations, such as e.g. residual current circuit breakers.
These protective devices must be provided by the customer.
› Observe the information on the type plate.
› Close all covers after work has been carried out.
› Keep moisture and dust away from live parts. Penetrating
moisture and dust can lead to a short circuit.
› If the electrical connection is made during precipitation, e.g.
rain or snow, prevent the penetration of moisture by means of
suitable protective covers.
› During or after a lightning strike into the system, there is
danger to life if the components are touched or during a stay
in the immediate vicinity of the system. When installing
outdoors, do not install and mount the pedestrian gate during
thunderstorms.

16
mTripod
Safety
2.7 To protect the environment
Improper disposal!
Improper disposal can lead to damage to the environment.
› Dispose of product in accordance with local and national laws
and regulations.
› Sort resources and supply them to recycling.
2.8 Emergency opening of the pedestrian gate
äPage 66, chapter 8.4.1.

17
mTripod
Technical data
3 Technical data
3.1 Dimensions and design
3.1.1 mTripod-ML
55°
A A
Mag00811
1300
1239.5
290
1050
882
90
180
180
110
∅ 38
515
A
100
44
60
80
Fig. 1: Dimensions FMTP-ML (dimensions in mm)
A Dimensions for customer's access-control device

18
mTripod
Technical data
Designation Value
Dimensions
(length x width x height)
1300 mm x 290 mm x 1050 mm
äPage 17, Fig. 1.
Passage width 515 mm
Weight › Turnstile complete: Approx. 70 kg
› Optional foundation frame: Approx. 10.5 kg
Material › Housing: mDure
› Optional foundation frame: Stainless steel
Housing colour, standard › Side parts: basalt
› Frame: anthracite
Table 3: Dimensions and design – mTripod FMTP-ML

19
mTripod
Technical data
3.1.2 mTripod-MS
55°
A A
Mag00924
730
670
290
1050
882
90
180
180
110
∅ 38
515
A
100
44
60
80
Fig. 2: Dimensions FMTP-MS (dimensions in mm)
A Dimensions for customer's access-control device
Designation Value
Dimensions
(length x width x height)
730 mm x 290 mm x 1050 mm
äPage 19, Fig. 2.
Passage width 515 mm
Weight › Turnstile complete: Approx. 56 kg
› Optional foundation frame: Approx. 5.4 kg
Material › Housing: mDure
› Optional foundation frame: Stainless steel
Housing colour, standard › Side parts: basalt
› Frame: anthracite
Table 4: Dimensions and design – Tripod FMTP-MS

20
mTripod
Technical data
3.2 Clearances and line configuration to be maintained
Mag00817a
11
50
1050
882
515290
50
Fig. 3: Clearances and line configuration to be maintained
1 Minimum distance 50 mm