52
GB
52
General
This manual contains
instructions about how the
Contura 50 series must be
assembled and installed.
To guarantee the function and safety of the stove we recommend
that it is installed by a professional. Our Contura agents can
recommend a suitable installer.
Instructions for lighting and use are also supplied with the stove.
Read them carefully and keep them safe for future use.
The stove meets with the requirements which allow it to be
connected to a chimney with gas temperatures of 350°C, the
external connection diameter is Ø150 mm. Supply air from the
open air should be used as combustion air.
Building application
Before installing a stove or erecting a chimney it is necessary for
you to apply for planning permission from your local authority. Ask
your local authority for advice regarding building regulations and
the application.
Structural support
Check that the wood joists are strong enough to bear the weight of
the stove and chimney. The stove and chimney can usually be placed
on a normal wooden joist in a single occupancy house if the total
weight does not exceed 400 kg.
Hearth plate
To protect the floor from any embers the stove must be placed on
a hearth plate. If the floor under the stove is flammable, it must be
protected by a non-flammable material which covers at least 300
mm to the front and 100 mm on each side.
The hearth plate can consist of natural stone, concrete or 0.7 mm
metal. As an accessory, the hearth plate is available in painted steel.
Chimney
The stove requires a draft in the chimney of at least –12 Pa. The
draught is affected both by the length and area of the chimney, and
by how well sealed it is. Minimum recommended chimney length is
3.5 m and a suitable cross section area is 150-200 cm² (140-160
mm in diameter). Carefully check that the chimney is sealed and that
there is no leakage around soot hatches and flue connections.
Maximum chimney weight loading on the stove 120 kg.
Note that a flue with sharp bends and horizontal routing reduces
the draught in the chimney. Maximum horizontal flue is 1 m, on the
condition that the vertical flue length is at least 5 m. It must be
possible to sweep the full length of the flue and the soot hatches
must be easily accessible.
HANDÖL
Inaccordance with standards below
markingwas affixed:
EuropeanStandard:
SEQuality Certification, P-marked:
NOStandard NS 3059:
DEand A Standard DINplus
andArt 15a B-VG:
Type:
NominalOutput:
Fuel:
Minimundraught:
Fluegas temerature:
Energyefficiency:
Emissionof CO in cumbustion products:
Distanceto cumbustible wall (mm):
Productionnumber:
Followthe installation instructions.
Useonly recomended fuels
NIBEAB Box 134 SE-285 23 MARKARYD SWEDEN
2006
EN13240
Certno 220316
SINTEF110-0257
RRF-4007 1261
H51/H52/H52T
5kW
Wood
12Pa
275°C
79%
0,13%
Behind150
Beside500
Corner150
HANDÖL
NIBE AB SE-85 21 Markaryd Sweden
Type:
Production no.
50-series
7090300236
Technical data
Output 3-7 kW
Nominal output 5 kW
Efficiency level 79%
Model 51 52 52T 53 54 54T
Weight (kg) 128 135 172 143 149 190
Width (mm) 495 495 495 550 550 550
Depth (mm) 420 420 420 455 455 455
Height (mm) 825 825 875 825 825 875
The connection’s external diameter is Ø150 mm.
Type approved in accordance with:
European standard EN-13240
Swedish environmental and quality marking,
P-marking cert. no. 22 03 16
(N) NS 3059, Cert.nr SINTEF 110-0257
(DE/A) DINplus, Art. 15a B-VG RRF-40 07 1261
Fire-box surround
Grate shuttle
Ash-pan
Log guard
Air supply control
Removable handle
Type plate