19
!
3-9 kW 1290 mm 580 mm 515 mm 250 kg
Installation by authorised
technician
This manual contains instructions about how
the stoves must be assembled and installed.
To ensure the function and safety of the stove,
we recommend that the installation is carried
out by an authorised technician. Contact one
of our dealers who can recommend suitable
technicians.
Building application
These main instructions may give guidance
which would contravene national building
regulations. Please refer to supplementary
instructions or ask your local authority for
advice regarding building regulations.
Before installing a stove or erecting a chimney
it is necessary for you to make a building
application permission to your local authority.
The owner of the house is personally
responsible for ensuring compliance with the
mandatory safety requirements and must
have the installation approved by a qualified
inspector. Your local chimney sweep must
also be informed about the installation as this
will affect the routines for regular chimney-
sweeping services.
Structural support
Check that the wood joists are strong enough
to bear the weight of the stove and chimney.
The stove and chimney can usually be placed
on a normal wooden joist in a single occupancy
house if the total weight does not exceed
400 kg.
Hearth plate
Due to the risk of falling embers, a flammable
floor must be protected by a hearth plate. It
must extend 300 mm in front of the stove and
100 mm on each side of the stove, or have a
200 mm extension on each side of the opening.
The hearth plate can consist of natural stone,
concrete, metal plate or glass. A glass hearth
plate is available as an accessory for these
models.
Final inspection of the
installation
It is extremely important that the installation
is inspected by an authorised chimney sweep
before the stove is used. Also read the
”Lighting instructions”, before lighting for the
first time.
Nominal effect 6 kW
Efficiency 86 %
Type approved in accordance with:
European standard EN-13240
NS 3059 (Norway)
BImSchV.2 (Germany)
Art. 15a B-VG (Austria)
Clean Air Act. (UK)
The stove becomes very hot
During operation, certain surfaces of the
stove become very hot and can cause
burn injury if touched. Be aware of the
strong heat radiated through the hatch
glass. Placing flammable material closer
than the safe distance indicated may
cause a fire. Pyre lighting can cause quick
gas ignition with the risk of damage to
property and personal injury.
Connection to chimney
• The stove must be connected to chimneys dimensioned for a minimum flue
gas temperature of 400°C.
• The external diameter of the connection sleeve is 150 mm.
• Normal chimney draw under nominal operation should be between 20-25
Pa close to the connector. The draft is affected both by the length and
area of the chimney, and by how well sealed it is. Minimum recommended
chimney length is 3.5 m and suitable cross section area is 150-200 cm²
(140-160 mm in diameter).
• A flue with sharp bends and horizontal routing reduces the draught in
the chimney. Maximum horizontal flue is 1 m, on the condition that the
vertical flue length is at least 5 m.
• It must be possible to sweep the full length of the flue and the soot
hatches must be easily accessible.
• Carefully check that the chimney is sealed and that there is no leakage
around soot hatches and flue connections. See page 40.
Supply of combustion air
When a stove is installed in a room, the demand for air supply to the room
increases. Air can be provided indirectly via a vent in the outer wall or via a
duct from the outside that is connected to the connector on the underneath
of the stove. The amount of air needed for combustion is 15 m3/h.
The connector for the combustion air has an external diameter of 67 mm.
When duct routing further than 1 m the pipe diameter must be increased to
100 mm and a correspondingly larger wall vent must be selected.
In hot areas, the duct should be insulated with 30 mm mineral wool with a
moisture inhibiting outer cover. It is also important to seal around the hole
in the wall (or floor) of the lead-in using sealant.
A 1 m length of condensation insulated ducting for combustion air is
available as an accessory. See page 42.
Facts
Contura reserves the right to change dimensions and procedures described in these instructions
at any time without special notice. The current edition can be downloaded from www.contura.eu
GB
20
!
The minimum distance in front of
the stove opening to combustible
parts of the building or interior
decoration must be at least 1,2 m.
The dimension diagrams only
show the minimum permitted
installation distances for the
stove. When connecting to a steel
flue, also note the safety distance
requirements of the flue. The
safety distance between an un-
insulated flue and a combustible
part of the building should be at
least 450 mm.
Installation distances
WHEN INSTALLING TURNTABLE (OPTION) the follow-
ing installation distances do not apply.
See the separate turntable installation instructions.
A = height from floor to chimney
connection upwards
B = height from floor to c/c chimney
connection rear
C = height from floor to air inlet
D = height from floor to lower edge
of hatch
A separate glass hearth
plate (accessory)
increases the connection
height to the chimney by
10 mm.
Permitted area for
combustible parts
of the building
* If the stove is placed on a hearth plate made of glass for example (accessory), the height from the floor is affected by a distance corresponding to the thickness of the hearth plate, for a free standing
glass hearth plate this is 10 mm.
** To prevent discolouration of painted non-flammable walls we recommend that the same side distance as to combustible walls is used.
INSTALLATION AGAINST COMBUSTIBLE WALLS INSTALLATION AGAINST FIREWALLS
1290
580
2100*
D 367
92
219
Combustible roof
140
110
B 1078*
A 1205*
C 389
40
515
Air inlet Ø67
Ø150
848
685
335
100
Combustible wall
650
780
636
285
50
650
Fire-retardant wall
of brick or concrete
1100
520
192
50
227**
900
Fire-retardant wall
of brick or concrete
800
507
570
570
242
100
Combustible wall
C620T / C620TG Style
GB
21
PRODUCT
Type Wood burning stove
Trade name Contura 620T
Intended area of use Heating of rooms in residential buildings
Fuel Wood
MANUFACTURER
Name NIBE AB / Contura
Address Box 134, Skulptörvägen 10
SE-285 23 Markaryd, Sweden
VERIFICATION
According to AVCP System 3
European standard EN 13240:2001 / A2:2004 / AC:2007
Test institute Rein-Ruhr Feuerstätten Prüfstelle, NB 1625.
D e c l a r a t i o n o f p e r f o r m a n c e a c c o r d i n g
to Regulation (EU) 305/2011
DECLARED PERFORMANCE
ESSENTIAL CHARACTERISTICS PERFORMANCE HARMONISED TECHNICAL
SPECIFICATION
Fire safety Pass
Fire classification A1
Minimum distance to flammable
materials
Rear: 100 mm
Side: 507 mm
Ceiling: 810 mm
Front: 1200 mm
Floor: 0 mm
Corner: 100 mm
Fire hazard due to burning fuel falling out Pass EN 13240:2001 / A2:2004 / AC:2007
Cleanability Pass
Emissions from combustion CO: 0,08%
Surface temperatures Pass
Temperature on the handle Pass
Mechanical resistance Pass
Temperature in the space for wood storage Pass
Nominal output 6,0 kW
Efficiency 86,0%
Flue gas temperature at nominal output 206°C
Flue gas temperature in flue spigot 247°C
The undersigned is responsible for the manufacture and conformity with the declared performance.
Niklas Gunnarsson, Business area manager NIBE STOVES
Markaryd, December 19, 2019
No. C620T-CPR-191219
GB
22
EU Declaration of Conformity
Manufacturer NIBE AB / Contura
Address Box 134, Skulptörvägen 10
285 23 Markaryd, Sweden
E-Mail info@contura.se
Website www.contura.eu
Telephone +46 433 275100
THIS DECLARATION OF CONFORMITY IS ISSUED UNDER OUR SOLE RESPONSIBILITY FOR THE FOLLOWING PRODUCT:
Trade name Contura 600 Style-series 610 (A) / 620 (T) / 690 (A/T)
Identification of product www.contura.eu
THE OBJECT OF THE DECLARATION DESCRIBED ABOVE IS IN CONFORMITY WITH -
THE RELEVANT UNION HARMONIZATION LEGISLATION: THE RELEVANT HARMONIZED STANDARDS:
DIR 2009/125/EC EN 13240:2001/A2:2004/AC:2007
REG (EU) 2015/1185 CEN/TS 15883:2010
REG (EU) 2015/1186
REG (EU) 2017/1369
REG (EU) 305/2011
TECHNICAL DOCUMENTATION
Indirect heating functionality: No
Direct heat output: 6,0 kW
Energy Efficiency Index (EEI): 114,7
Test report RRF 40 17 4615, NB 1625
CHARACTERISTICS WHEN OPERATING WITH THE PREFERRED FUEL
ITEM SYMBOL VALUE UNIT ITEM SYMBOL VALUE UNIT
HEAT OUTPUT USEFUL EFFICIENCY, BASED ON NET CALORIFIC VALUE (NCV )
Nominal heat output: Pnom 6,0 kW Useful efficiency at nominal
heat output η th,nom 86,0 %
AUXILIARY ELECTRICITY CONSUMPTION TYPE OF HEAT OUTPUT/ROOM TEMPERATURE CONTROL
At nominal heat output elmax - kW Single stage heat output, no room temperature control Yes
At minimum heat output elmin - kW Two or more manual stages, no room temperature control No
In standby mode elSB - kW With mechanic thermostat room temperature control No
With electronic room temperature control No
With electronic room temperature control plus day timer No
With electronic room temperature control plus week timer No
OTHER CONTROL OPTIONS
Room temperature control, with presence detection No
Room temperature control, with open window detection No
With distance control option
Specific precautions for assembly,
installation, or maintenance.
Fire protection and safety distances to combustible building materials must be observed under all circumstances.
A sufficient supply of combustion air must always be guaranteed. Air suction systems can interfere with the combustion
air supply.
FUEL PREFERRED
FUEL OTHER SUITABLE
FUEL η S (%)
EMISSIONS AT NOMINAL HEAT OUTPUT
PM OGC CO NOx
mg/ Nm3 (13% O2)
Wood logs with moisture content ≤25% Yes No 76,0 <40 <120 <1500 <200
Compressed wood with moisture content <12% No Yes 76,0 <40 <120 <1500 <200
Other woody biomass No No
Non-wood biomass No No
Anthracite and dry steam coal No No
Hard coke No No
Low temperature coke No No
Bituminous coal No No
Lignite briquettes No No
Peat briquettes No No
Blended fossil fuel briquettes No No
Other fossil fuel No No
Blended biomass and fossil fuel briquettes No No
Other blend of biomass and solid fuel No No
The undersigned is responsible for the manufacture and conformity with the declared performance.
Niklas Gunnarsson, Business area manager NIBE STOVES
Markaryd, January 1, 2022

This manual suits for next models

1

Other Contura Stove manuals

Contura C 630 User manual

Contura

Contura C 630 User manual

Contura C 800 User manual

Contura

Contura C 800 User manual

Contura C 850W User manual

Contura

Contura C 850W User manual

Contura C 480 User manual

Contura

Contura C 480 User manual

Contura C i10 User manual

Contura

Contura C i10 User manual

Contura NIBE i50 User manual

Contura

Contura NIBE i50 User manual

Contura C i40 User manual

Contura

Contura C i40 User manual

Contura 580 User manual

Contura

Contura 580 User manual

Contura Vridplatta C500 User manual

Contura

Contura Vridplatta C500 User manual

Contura C 780 User manual

Contura

Contura C 780 User manual

Contura C i5 User manual

Contura

Contura C i5 User manual

Contura C 51L User manual

Contura

Contura C 51L User manual

Contura 51 User manual

Contura

Contura 51 User manual

Contura C690 Style User manual

Contura

Contura C690 Style User manual

Contura C i4 User manual

Contura

Contura C i4 User manual

Contura C 32 User manual

Contura

Contura C 32 User manual

Popular Stove manuals by other brands

HASE BASILIA Maintenance and installation instructions

HASE

HASE BASILIA Maintenance and installation instructions

hergom C-14 Installation, use and maintenance instructions

hergom

hergom C-14 Installation, use and maintenance instructions

Continental Fireplaces CDVS500P Installation and operation manual

Continental Fireplaces

Continental Fireplaces CDVS500P Installation and operation manual

Force 10 751 Series owner's manual

Force 10

Force 10 751 Series owner's manual

Nordpeis SA-ME000-C84 Installation and user manual

Nordpeis

Nordpeis SA-ME000-C84 Installation and user manual

Olsberg Vela Instruction

Olsberg

Olsberg Vela Instruction

Costway NP10722 user manual

Costway

Costway NP10722 user manual

Lotus Mondo Series Mounting and user instructions

Lotus

Lotus Mondo Series Mounting and user instructions

Desa CGESBMRA Safety and operation manual

Desa

Desa CGESBMRA Safety and operation manual

Nibe Contura C596 manual

Nibe

Nibe Contura C596 manual

Flavel Arundel XL MK2 Installation and operating instructions

Flavel

Flavel Arundel XL MK2 Installation and operating instructions

Hamlet Hero Deluxe Operating & installation manual

Hamlet

Hamlet Hero Deluxe Operating & installation manual

Percy Doughty & Co FIREFOX 8 Installation and operating instructions

Percy Doughty & Co

Percy Doughty & Co FIREFOX 8 Installation and operating instructions

Cadel MITHOS PLUS 12 PS Installer manual

Cadel

Cadel MITHOS PLUS 12 PS Installer manual

CPL PORTA OVEN PRO 40 user manual

CPL

CPL PORTA OVEN PRO 40 user manual

Austro Flamm Ruby operating manual

Austro Flamm

Austro Flamm Ruby operating manual

Palazzetti Sphera idro Installation - use - maintenance

Palazzetti

Palazzetti Sphera idro Installation - use - maintenance

Zibro ARABELLA operating manual

Zibro

Zibro ARABELLA operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.