Cooper Lighting HALO LED H4 SERIES H456ICAT120D User manual

Catalog #
Project
Comments
Prepared by
Type
Date
HALO LED H4 Series
The Halo H4 LED is a family of 4” aperture recessed downlight
housings designed for use with Halo EL4 Series LED Light Engines
and compatible 4” LED trims. Halo H4 LED housings have integral
LED drivers that offer dimming as a standard feature.
H456ICAT120D is an insulated ceiling, AIR-TITETM housing offering
120 volt dimming capability with many incandescent or electronic
low voltage dimmers. Designed for use with EL4 series LED Light
Engines and TL4 LED Series Trims, the H456ICAT120D offers high
quality downlighting along with high efficacy – the result being great
lighting and significant energy savings.
MECHANICAL
Housings
• Box enclosure of formed
aluminum construction.
• Openings are gasketed
AIR-TITE.
• Designed for insulated ceilings in
direct contact with insulation.
(May also be installed in
non-insulated ceilings.)
Plaster Frame
• Galvanized steel die-formed
construction.
• The housing can be removed from
plaster frame to provide access to
the junction box.
• Plaster frame features include:
- Patented regressed locking screw
positioned for securing hanger
bars from below the ceiling.
- Cutouts for easily crimping
hanger bars in position.
- AIR-TITE aperture gasket is
pre-installed.
- HALO identity embossed on
plaster frame.
GOT NAIL! Pass -N-Thru™
Bar Hangers
• Pre-installed nail easily installs
in regular lumber, engineered
lumber and laminated beams.
• Safety and guidance system
prevents snagging, ensures
smooth straight nail penetration
and allows bar hangers to be easily
removed if necessary.
• Automatic leveling flange aligns
the housing and lets you hold the
housing in place with one hand
while driving nails.
• Housing can be positioned at any
point within 24” joist span.
• Pass-N-Thru™ feature allows bar
hangers to be shortened without
removing from plaster frame.
• Score lines allow “tooless”
shortening for 12” joists.
• Bar hangers may be repositioned
90°.
• Integral T-bar clip snaps onto
T-bars - no additional clips
required.
Slide-N-Side™ Junction Box
• Positioned to accommodate
straight conduit runs
• Seven 1/2” trade size conduit
knockouts with true pry-out slots
• Slide-N-Side™ wire traps allow
non-metallic sheathed cable to be
installed without tools and
without removing knockouts.
• Accepts a wide range of
non-metallic (type NM) sheathed
cables - the standard cable types
used in lighting in both U.S. and
Canada.
- Allows wiring connections to be
made outside the junction box
- Simply insert the cable directly
into the trap after connections
are made.
- Accommodates the following
standard non-metallic sheathed
cable sizes:
(US) #14/2, #14/3, #12/2, #12/3
(Canada) #14/2, #14/3, #12/2
LED Connection
• LED connector is a non-screw base
connector offering easy installation
with the EL4 Series LED Light
Engine.
• LED connector meets California
Title-24 high-efficacy luminaire
requirement for a non-screw
base socket, and where required
to qualify as a high-efficacy
luminaire.
LED Driver
• LED dimmable driver mounts
to the housing.
• Driver is a120 Volt, high efficiency,
electronic power supply providing
low voltage power to EL Series
LED Light Engines.
• Driver meets FCC EMI/RFI
Consumer Level limits for use in
residential and commercial
installations.
• Driver features high power factor
and low THD and has integral
thermal protection in the event
of over temperature or internal
failure.
• Driver is specifically designed
for compatibility with EL4 LED
Light Engines, and operates the
LED for long life, meeting 50,000
hour / 70% lumen maintenance
standard.
• If dimming is not required the
fixture can be operated from a
standard wall switch.
Dimming
• The HALO H4 LED luminaire is
dimmable to 15% with most
standard 120V dimmers;
including LED-rated and
electronic low voltage dimmers
(recommended); many
incandescent and magnetic low
voltage dimmers; and dims to 5%
using dimmers with low end trim
adjustment.
• Standard incandescent dimmers
require a minimum load of
typically over 40 watts on the
circuit for full range dimming
performance (four LED modules).
• For dimming with digital (smart)
multi-location dimmers or when
dimming fewer than four LED
modules, LED rated or electronic
low voltage dimmers are required
(ELV dimmers need a neutral
connection in the wallbox).
Labels
• UL/cUL Listed 1598 Luminaire
• UL/cUL Listed for Damp Location
• UL/cUL Listed for Wet Location,
covered ceiling - with select trims
• UL/cUL listed for Feed Through
• UL/cUL listed for Direct Contact
with insulation and combustible
material
Compliance
• Use with designated LED light
engines and trims for ENERGY
STAR® qualification.
• Can be used for State of California
Title 24 high efficacy compliance
with designated LED light engines
and trims.
• Can be used for International
Energy Conservation Code (IECC)
high efficacy compliance with
designated LED light engines
and trims.
• Refer to specification sheets online
for compliance information.
Qualification
IC and AIR-TITE™
Certified under ASTM-E283 and
listed UL/cUL 1598. May be used to
meet insulated ceiling and restricted
air-flow requirements such as:
• Washington State Energy Code
• International Energy
Conservation Code (IECC)
• New York State Energy
Conservation Construction
Code (NY-ECCC)
• State of California Title 24
“Recessed Luminaires in
Insulated Ceilings.”
DESIGN FEATURES
H456ICAT120D
4-Inch LED
Recessed Housing
New Construction
Insulated Ceiling -
With 4” LED Light Engines
and 4” LED Trims
High Efficacy LED Housing-
Dimmable
H4 Series LED Energy Data:
(Values at non-dimming line voltage.)
Minimum Starting Temp: -30°C (-22°F)
EMI/RFI: FCC Title 47 CFR, Part 18
(Consumer)
Sound Rating: Class A standards
Input Voltage: 120V
Power Factor: >0.90
Input Frequency: 50/60Hz
THD: <20%
Rated Wattage: 15W max.
Input Power: 14.0W
Input Current: 121mA
Driver Compliance: UL6950, LPS rated
Maximum IC (Insulated Ceiling) Ambient
Continuous Operating Room Temperature:
25°C (77°F)
Maximum Non-IC (Non-Insulated Ceiling)
Ambient Continuous Operating Room
Temperature: 40°C (104°F)
H4 Series LED
Summary Lighting Data:
Lumen range: . . . . . . . . . . . . .534-700
Lumens per watt: . . . . . . . . . . up to 46
Color
Correlated Color Temperature
(CCT): . . . . . . . . . . . . . . .2700K-4000K
Color Rendering Index (CRI, Ra): . . . 80
www.cooperlighting.com ADV110681
rev 4/8/11
HALO®
FOR USE IN
INSULATED CEILINGS
FOR DIRECT CONTACT
WITH INSULATION
ALSO SUITABLE FOR
NON-IC APPLICATIONS
www.cooperlighting.com
ORDERING INFORMATION
SAMPLE NUMBER: H456ICAT120D EL405827 TL400SC
Complete unit includes LED housing, light engine, and trim, ordered separately
DIMENSIONS
H456ICAT120D
HALO®
H456
H456=
4˝ Housing
H4 LED Series
Downlight
120D
120D=
LED driver,
120V, 50/60Hz,
Dimmable - most
standard electronic
low voltage
(recommended)
and incandescent/
magnetic low
voltage dimmers
(see dimming
application notes,
and refer to dimmer
manufacturers for
compatiblity)
H4 LED Housing
ICAT
ICAT=
New Construction,
Insulated Ceilng,
AIR-TITE
Accessories
Designer Trim Rings, Thin Profile
TRM400WH=White, die-cast trim ring
TRM400BK=Black, die-cast trim ring
TRM400SN=Satin Nickel, die-cast trim ring
TRM400TBZ=Tuscan Bronze, die-cast trim ring
TRM400PC=Polished Chrome, die-cast trim ring
EL4
EL4=
4˝ LED
Downlight
Light Engine
8
8=
80 CRI
05
05=
550
Design
Lumens*
27
27=2725°K
30=3045°K
35=3465°K
40=3985°K
H4 LED Light Engine
TL40x
TL400SC= Specular Clear Refector, White Trim Ring
TL400H=Haze Reflector, White Trim Ring
TL400WH=White Reflector, White Trim Ring
TL400SBK=Specular Black Reflector, White Trim Ring
TL400SN=Satin Nickel Reflector, Satin Nickel Trim Ring
TL400TBZ=Tuscan Bronze Reflector, Tuscan Bronze
Trim Ring
TL401WB=White Baffle, White Trim Ring
TL401BB=Black Baffle, White Trim Ring
TL402SCS=Specular Clear Reflector with Solite® Lens,
White Trim Ring
TL402HS=Haze Reflector with Solite® Lens, White Trim Ring
TL402WHS=White Reflector with Solite® Lens,
White Trim Ring
TL402SBKS=Specular Black Reflector with Solite® Lens,
White Trim Ring
TL402SNS=Satin Nickel Reflector with Solite® Lens,
Satin Nickel Trim Ring
TL402TBZS=Tuscan Bronze Reflector with Solite® Lens,
Tuscan Bronze Trim Ring
TL403WBS=White Baffle with Solite® Lens, White Trim Ring
TL403BBS=Black Baffle with Solite® Lens, White Trim Ring
H4 LED Trim
* Lumen output range of 534-700
lumens (depending upon color
temperature and trim)
6 inch
(152 mm)
1/2 inch
(13 mm)
5-3/8 inch
(136 mm)
outer dimension
8-1/2 inch
(216 mm)
4-1/4 inch
(108 mm)
Watt Stopper
Miro Incandescent DRD2 Series Dimmers
DCD26 Series Dimmers
DCD68 Series Multilocation - When used with DRD2 or DCD26
series master dimmers
• Incandescent Wireless Dimmers
• Minimum Circuit Load of Five LED Modules, Dimming to 15%
A 15W minimum incandescent load or a neutral in the wall box may be required to reliably dim
Lutron - Whole House
Homeworks HW-RPM-4A-120 Remote Power Module-Adaptive Dimming
HW-RPM-4V-120 Remote Power Module-Dimming
HWD-5NE, HRD-5NE Wired Maestro and RF Maestro Local Controls
120V AC dimmed power
to Halo LED Downlights
120V AC Power
(2 wire + Gnd typical)
1
t
Standard Dimming Control
Leviton
Illumitech™ IPI/RPI Series
Sureslide™ 663 Series
Trimatron™ 6681/6683/6602
TrueTouch™ 6606-ILM
Lutron
Diva® DVELV Series
Maestro® MAELV Series
Nova® NLV Series
Nova T® NTELV & NTLV Series
Skylark® SELV Series
Vierti® VTELV Series
Leviton
Minimum Brightness Adjustment (Low End Trim), Dimming to 5%
Acenti® ACE Series (Programmable trim)
IllumiTech™ IPE Series (Manual trim)
Vizia + VPE Series (Programmable trim)
Cooper Wiring Devices
ASPIRE RF® N/A
ASPIRE™ 9530, 9532, 9538, 9540
Decorator Slide® DI06P, DI10P
Decorator Full-Slide® SI061, SI06P, SI10P
Toggle® 6441, 6443, 6453
Rotary® 6001, 6013, 6000, 6003, 6020, 6023
Architectural Rotary® RAI10, RAI15, RAI20
Cooper Wiring Devices - LED Dimmers (Low End Trim)
ASPIRE 9573
Skye SLC03P
Devine DLC03P
SPECIAL NOTE: Incandescent Digital Dimmers
Incandescent Digital Dimmers (also called Smart or Multi-Location)
require an incandescent load. For circuit loads with LED modules
only - use reverse phase control (electronic low voltage rated)
dimmers.
www.cooperlighting.com
H456ICAT120D
Reverse Phase Control - 120VAC  Dimmers
• Electronic Low Voltage rated dimmers are typically Reverse Phase (Trailing Edge)
• ELV rated dimmers provide greater assurance of dimming performance compatibility.*
• Minimum Circuit Load of One LED Module, Dimming to 15% (dimming to 5% with select dimmers as noted)
Require the neutral terminal on the dimmer connected to a neutral in the wall box.
Forward Phase Control Dimmers - 120VAC
• Incandescent and Magnetic Low Voltage rated dimmers are typiccally
Forward Phase (Leading Edge) Dimmers
• Circuit Load of 4 LED Modules or More, Dimming to 15%
• Forward phase control dimmers are generally compatible and typically
provide acceptable dimming results.*
Illumitech™ IP10/IP40/IPM406/IPM10 Series dimmers (Manual trim)
Acenti® ACI/ACE/ACX/ATI Series (Programmable trim)
Vizia + VPI/VPE/VPX Series (Programmable trim)
Minimum Brightness Adjustment (Low End Trim), Dimming to 5%
Watt Stopper
Miro Universal DRD4 Series Dimmers
DCD267 Series Dimmers
DCD68 Series Multilocation - When used with DRD4 or DCD267 series
master dimmers
• Universal Wireless Dimmers (Incandescent, Magnetic Low Voltage, Electronic Low Voltage)
• Minimum Circuit Load of Two LED Modules, Dimming to 15%
*Applications Notes
1. LED Dimming performance may vary from incandescent dimming. Performance results may vary based upon dimmer model,
manufacturer, circuit wiring and circuit loading.
2. Dimmer maximum load rating with LED may differ from published Incandescent and Electronic Low Voltage dimmer ratings.
Consult dimmer manufacturer for maximum dimmer load with LED.
3. For special dimming applications consult dimmer manufacturer or controls specialist (e.g. large multiple circuit installations, many
LEDs per circuit, sequenced fades, 277V or 347V circuits powered by step-down transformers, etc.).
4. There are no warranties of performance or compatibilty implied.
5. This is a representative list of dimmers. Refer to dimmer manufacturers for further information on LED compatiblity and finish codes.
Lutron, Leviton, LiteTouch, Crestron, Watt Stopper and their product brand names are registered trademarks of each respective company.
Lutron - Commerical
Commercial Panel Systems LP-RPM-4A120 Remote Power Module - Adaptive Dimming
LiteTouch, Inc.
LiteTouch 08-2108-01 Quad dimmer
LiteTouch 08-2134-01 Hybrid dimmer
(LiteTouch recommends the fade times be set for at least 2 seconds on and off for the FIVEk in
the load group parameters. Consult LiteTouch for additional technical application).
Crestron*
CLS-C6(M), CLS-EXP-DIM, CLS-EXP-DIMU, CLX-1DIM4, CLX-1DIM8, CLX-2DIM8, CLX-1DELV4,
DIN-1DIM4, DIN-1DIMU4, GLX-DIM6, GLXX-2DIM8 (Crestron recommends if more than 1 fixture
is connected, set MIN LEVEL=3% to ensure all fixtures turn on simultaneously at low end).
CLW-DIMSWEX, CLW-DIMSWCN, CLW-DIMEX, CLW-DIMCN, P-DIMEX (Consult Crestron for
LED compatibilty and technical application. Require Neutral wire connection at dimmer and
custom firmware).
*Consult Crestron for Control System Min-Max % level Intensity recommendations.
Lutron
Ariadni® AY/TG Series
Ceana™ CN Series
Centurion® C Series
Dalia™ DL Series
Diva® DV Series
Glyder® GL Series
Lumea™ LG Series
Lyneo™ LX Series
Nova® N Series
Nova T® NT/NTB/NTA Series
Qoto™ Q Series
Skylark® S Series
Dimmer Types & Representative List of Manufacturers*
Cooper Controls
iLumin SC-UN Universal Source Controller Series - Lighting Control Panel System
www.cooperlighting.com
H456ICAT120D
HALO®
Note: Specifications and Dimensions subject to change without notice.
Visit our web site at www.cooperlighting.com
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 486.4801
Cooper Lighting 5925 McLaughlin Rd. Mississauga, Ontario, Canada L5R 1B8 905.507.4000 FAX 905.568.7049
Solite® is a registered trademark of AGC Flat Glass North America
3 YEAR PRODUCT LIMITED WARRANTY
Cooper Lighting (The Company) warrants
the HALO H4x Series LED housings, Halo
EL4x, ELG4x, ELSGx Series LED Light
Engines, and HALO TL4x, TLS4x Series
LED Trims against defects in material or
workmanship for a period of three years
from date of original purchase, and agrees
to repair or, at the company’s option, re-
place a defective product without charge
for either replacement parts or labor dur-
ing such time. This does not include labor
to remove or install fixtures.
This warranty is extended only to the origi-
nal purchaser of the product. A purchasers
receipt or other proof of date of original
purchase acceptable to the Company is
required before warranty performance
shall be rendered. This warranty only
covers product failure due to defects in
materials or workmanship which occurs
in normal use. It does not cover the failure
of product caused by accident, misuse,
abuse, lack of reasonable care, altera-
tion, or faulty installation, subjecting the
product to any but the specified electrical
service or any other failure not resulting
from defects in materials or workmanship.
Damage to the product caused by sepa-
rately purchased, non-Company supplied
components and corrosion or discolor-
ation of components are not covered by
this warranty. There are no express war-
ranties except as described above.
THE COMPANY SHALL NOT BE LIABLE
FOR INCIDENTAL, SPECIAL OR CONSE-
QUENTIAL DAMAGES RESULTING FROM
THE USE OF THE PRODUCT OR ARISING
OUT OF ANY BREACH OF THIS WAR-
RANTY. ALL IMPLIED WARRANTIES, IF
ANY, INCLUDING IMPLIED WARRANTS
OF MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE, ARE
LIMITED IN DURATION TO THE DURA-
TION OF THIS EXPRESS WARRANTY.
Some states do not allow the exclusion
or limitation of incidental or consequential
damages, or limitations on how long an
implied warranty lasts, so the above exclu-
sions or limitations may not apply to you.
No other warranty, written or verbal, is
authorized by the Company. This war-
ranty gives you specific legal rights, and
you may also have other rights which vary
from state to state. To obtain warranty
service, please write to Cooper Lighting,
1121 Highway 74 South, Peachtree City,
Georgia 30269. Enclose product model
number and problems you are experienc-
ing, along with address and telephone
number. You will then be contacted with a
solution or a Return Goods Authorization
number and full instructions for returning
the product. All returned products must be
accompanied by a Return Goods Autho-
rization Number issued by the Company
and must be returned freight prepaid. Any
product received without a Return Goods
Authorization Number from the Company
will be refused. Cooper Lighting is not
responsible for merchandise damaged
in transit. Repaired or replaced products
shall be subject to the terms of this war-
ranty and are inspected when packed.
Evident or concealed damage that is made
in transit should be reported at once to
the carrier making the delivery and a claim
filed with them.

This manual suits for next models

1

Other Cooper Lighting Light Fixture manuals

Cooper Lighting Corelite Junction Box Structure Interface User manual

Cooper Lighting

Cooper Lighting Corelite Junction Box Structure Interface User manual

Cooper Lighting Halo H2601E70 Chorus User manual

Cooper Lighting

Cooper Lighting Halo H2601E70 Chorus User manual

Cooper Lighting HALO LV208 User manual

Cooper Lighting

Cooper Lighting HALO LV208 User manual

Cooper Lighting BCHE User manual

Cooper Lighting

Cooper Lighting BCHE User manual

Cooper Lighting METALUX 248VHO User manual

Cooper Lighting

Cooper Lighting METALUX 248VHO User manual

Cooper Lighting RKS-140RS-48-10B User manual

Cooper Lighting

Cooper Lighting RKS-140RS-48-10B User manual

Cooper Lighting Corelite Traverse Wall 1T5HO User manual

Cooper Lighting

Cooper Lighting Corelite Traverse Wall 1T5HO User manual

Cooper Lighting Combolight LV360MH User manual

Cooper Lighting

Cooper Lighting Combolight LV360MH User manual

Cooper Lighting COMBOLIGHT LV3010IS User manual

Cooper Lighting

Cooper Lighting COMBOLIGHT LV3010IS User manual

Cooper Lighting PM134OB User manual

Cooper Lighting

Cooper Lighting PM134OB User manual

Cooper Lighting AMETRIX ADY080117 User manual

Cooper Lighting

Cooper Lighting AMETRIX ADY080117 User manual

Cooper Lighting Cobolight CR2111100 User manual

Cooper Lighting

Cooper Lighting Cobolight CR2111100 User manual

Cooper Lighting METALUX F-BAY I8 User manual

Cooper Lighting

Cooper Lighting METALUX F-BAY I8 User manual

Cooper Lighting Combo Trimless Series LV-216-TR User manual

Cooper Lighting

Cooper Lighting Combo Trimless Series LV-216-TR User manual

Cooper Lighting Halo L4009 User manual

Cooper Lighting

Cooper Lighting Halo L4009 User manual

Cooper Lighting SURE-LITES EUS Series User manual

Cooper Lighting

Cooper Lighting SURE-LITES EUS Series User manual

Cooper Lighting Metalux MB154 User manual

Cooper Lighting

Cooper Lighting Metalux MB154 User manual

Cooper Lighting Halo L5300 User manual

Cooper Lighting

Cooper Lighting Halo L5300 User manual

Cooper Lighting ALL-PRO ET700 User manual

Cooper Lighting

Cooper Lighting ALL-PRO ET700 User manual

Cooper Lighting F-Bay I8 Series User manual

Cooper Lighting

Cooper Lighting F-Bay I8 Series User manual

Cooper Lighting ComboLight Suspended Series User manual

Cooper Lighting

Cooper Lighting ComboLight Suspended Series User manual

Cooper Lighting Halo L704 User manual

Cooper Lighting

Cooper Lighting Halo L704 User manual

Cooper Lighting LUMARK M4 User manual

Cooper Lighting

Cooper Lighting LUMARK M4 User manual

Cooper Lighting FAIL-SAFE 1509 User manual

Cooper Lighting

Cooper Lighting FAIL-SAFE 1509 User manual

Popular Light Fixture manuals by other brands

Philips Lytecaster 316X specification

Philips

Philips Lytecaster 316X specification

Anslut 423-260 Assembly instructions

Anslut

Anslut 423-260 Assembly instructions

ShowPro PLUTO 800 user manual

ShowPro

ShowPro PLUTO 800 user manual

ALW LIGHTPLANE 11 installation instructions

ALW

ALW LIGHTPLANE 11 installation instructions

Philips ProSpec 26000 specification

Philips

Philips ProSpec 26000 specification

Lightolier SLB2SFSVA26U specification

Lightolier

Lightolier SLB2SFSVA26U specification

Westinghouse W-048 owner's manual

Westinghouse

Westinghouse W-048 owner's manual

Rebel Light ZAR0477 Guide

Rebel Light

Rebel Light ZAR0477 Guide

Philips 69108-35-PU Specification sheet

Philips

Philips 69108-35-PU Specification sheet

Satco NUVO S8031 Installation and safety instructions

Satco

Satco NUVO S8031 Installation and safety instructions

Klus LESTO Mounting instructions

Klus

Klus LESTO Mounting instructions

Eco A120 user guide

Eco

Eco A120 user guide

Anolis ArcSource Outdoor 24 MC Integral SmartWhite User instructions

Anolis

Anolis ArcSource Outdoor 24 MC Integral SmartWhite User instructions

Touch Of ECO LITEUP100 quick start guide

Touch Of ECO

Touch Of ECO LITEUP100 quick start guide

Elsner Cala KNX IL Installation and adjustment

Elsner

Elsner Cala KNX IL Installation and adjustment

IKEA LUNNOM LED1839S2 quick start guide

IKEA

IKEA LUNNOM LED1839S2 quick start guide

Licatec PLM III Assembly instruction

Licatec

Licatec PLM III Assembly instruction

Gavita Pro line HortiStar 600 SE EU manual

Gavita

Gavita Pro line HortiStar 600 SE EU manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.