Cooper Security i-dig02 User manual

i-dig02
Digital Communicator
Installation Guide

i-dig02
Page 2
Introduction
The i-dig02 module is designed to fit on the i-on40 control unit. The
i-dig02 allows the control unit to report alarm conditions over the
public switched telephone network (PSTN) using standard ARC
protocols such as Fast Format, SIA I, -II, –III, or extended SIA,
Contact ID, or SMS (Short Message Service) texts to mobile
telephones by way of the PSTN. In addition the i-dig02 allows
Downloader software to communicate with and monitor the control
unit.
Figure 1 shows the main features of the module.
3
12
1. Pins for ADSL filter 2. Telephone line connector
3. Off-hook LED
Figure 1. i-dig02 Module
Installation
Safety Notice
Figure 2 identifies connectors for Safety Extra-Low Voltage (SELV)
and Telecommunications Network Voltage (TNV) circuits on the
control unit's main PCB. These terms are used in accordance with
the definitions in Safety Standard EN60 950.
The Installer must ensure that TNV terminals are connected only to
other circuits designated as TNV circuits (for example, the PTSN)

i-dig02
Page 3
and that SELV terminals are connected only to other circuits
designated as SELV circuits. Strict adherence to the installation
instructions will ensure that the equipment continues to comply
with the safety regulations to which it was approved.
1. SELV
terminals
2. TNV
terminals.
1
2
Figure 2. SELV and TNV Terminals
CAUTION: Make sure that the end station is not powered (either
mains or battery) before fitting the i-dig02.
Preparation
Before fitting the i-dig02 module, check whether the telephone line
you intend to use is shared with an ADSL (broadband) modem. If it
is, then remove the factory fitted jumpers from the i-dig02 and fit
filter ADSL01 as shown in Figure 3 .
ADSL01
Figure 3. Fitting ADSL01 to i-dig02

i-dig02
Page 4
Note: If the telephone line is NOT shared with an ADSL modem
then leave the factory fitted jumpers in place.
Installing the Module in the End Station
1. Remove mains power from the end station.
2. Open the end station lid and disconnect the battery.
3. Fit the i-dig02 to the plug on module sockets (see Figure 4).
Figure 4. Fitting i-dig02 Module
4. Connect the module to the PSTN.
ABCEA1B1
See Not e
PSTN
WARNING: Telecommunications Network Voltage
A, B Connect to PSTN
A1, B1 Connect to local phone extension (if required)
E For added surge protection connect to a suitable protective earth.
C Note: (UK only) connect to ringing wire from PSTN and to ringing wire on extension
phone, if fitted.
Figure 5. Telephone Connection

i-dig02
Page 5
The person connecting the i-dig02 module to the PSTN must be
suitably qualified. Connect the i-dig02 telephone connector (see
Figure 5) ONLY to the PSTN or to other circuits designated as
Telecommunications Network Voltage.
Programming
For details on programming the i-dig02 please refer to the
i-on40 Programming Reference Guide. All the options necessary for
programming the module are in the Installer Menu under the
Communications – ARC Reporting option.
Note: The control unit hides the Communications - ARC Reporting
option if there is no i-dig02 fitted.
Finishing the Installation
Once programming is complete:
Re-fit the lid of the end station.
Test the module using the options in the Installer Menu - Test option.

i-dig02
Page 6
NOTES:

i-dig02
Page 7
NOTES:

i-dig02
Page 8
© Cooper Security Ltd. 2009
Every effort has been made to ensure that the contents of this book are correct. However,
neither the authors nor Cooper Security Limited accept any liability for loss or damage caused
or alleged to be caused directly or indirectly by this book. The contents of this book are subject
to change without notice.
Printed and published in the U.K.
This manual applies to software used in the I-ON40 control unit with version 1.xx.xx software.
www.coopersecurity.co.uk
Product Support (UK) Tel: +44 (0) 870 757 5400.
Available between:
08:15 and 17:00 Monday to Friday.
Product Support Fax: (01594) 545401
Part Number 11966531 Issue 1
Table of contents