Vantage Installation Manual
Publication Number: 312031005INS - 5 - © 2003-2014, Cornelius Inc.
5. Connect numbered syrup source tubes to corresponding numbered stainless-steel syrup inlet tubes located
behind the front access panel on the Unit. (No.1 syrup inlet tube provides syrup to No.1 dispensing valve).
6. Connect carbonated water tubes from the remote carbonator to labeled flexible carbonated water inlet tubes
located behind the Unit front access panel.
SEALING UNIT BASE TO COUNTERTOP
NOTE: To comply with NSF International (NSF) requirements within the United states, the Unit
base must be sealed to the countertop. an alternative to sealing the Unit base to the countertop
would be to install Leg Kit (P/N 4923) on the Unit.
1. To meet NSF International (NSF) requirements, seal Unit to countertop with sealant, such as Dow Corning
RTV 731 or equivalent.
2. Install drip tray on Unit.
Hole in drip tray drain outlet may be opened and a drip tray drain hose may be connected
and routed to
a permanent drain.
PREPARING UNIT FOR OPERATION
Starting Refrigeration System
Starting Refrigeration System On Unit With Integral (Built-In Carbonator).
1. Fill water tank with clean water until water begins to run out of overflow tube into the drip tray.
Use low-mineral-
content water where a local water problem exist.
2. Adjust CO2 regulator for the Unit built-in cold carbonator at 60-psi maximum.
3. Open plain water source shutoff valve. Check for water leaks and repair if evident.
4. Plug Unit power cord into accessible electrical outlet meeting electrical specifications found on the Unit name-
plate with ELCB. The Unit refrigeration system will start after a 2-minute time delay and will begin building an
ice bank. The carbonator water pump will start and begin filling the carbonated water tank with carbonated
water. After the carbonated water tank has been filled with carbonated water, the water pump will stop. Pull up
on carbonated water tank relief valve to allow air to be purged from the tank.
Starting Refrigeration System On Unit Connected to Remote Carbonator).
1. Fill water tank with clean water until water begins to run out of overflow tube into the drip tray.
Use low-mineral-
content water where a local water problem exist.
2. Adjust CO2 regulator for the Remote carbonator to CO2 pressure specified in manual provided with the carbon-
ator.
3. Plug Unit power cord into electrical outlet meeting electrical specifications found on the Unit nameplate. The
Unit refrigeration system will start after a 2-minute time delay and will begin building an ice bank.
ADJUSTING SYRUP SOURCE CO2 REGULATOR
Sugar Syrup Tanks CO2 Regulator.
Adjust syrup tanks CO2 regulator to a minimum of 45-psi.
Syrup Pumps (Bag-In-Box System).
Adjust syrup pumps CO2 regulator to 70-psi.
DO NOT EXCEED MAXIMUM CO
2
PRESSURE SPECIFIED ON
THE SYRUP
PUMPS.