After the Timer-Off or the Timer-On, the Timer indicator lights.
e).Up\Down Key: Press this two key to set the desired room temperature.(Press the Up
key once, the temperature will increase by 1 or 1 , also press the down key to
decrease by 1 or 1 ), can also set the time in Timer situation; ca n also exchange
from ℃to display by pressing these two keys at the same time.
*
2. Operation instructions:
a) In the Cooling models:
16-30℃(60-86 ℉)
Under cool mode, user can choose High or Low fan speed. The range of setting
temperature is
In the mode, pressing Timer and Down button can senter sleep function, In sleep
function, the set temperature increases 1 (1℉)
After operating for anot
automatically two hours later.
her 2 hours, the set temperature will
Then, the set temperatur
increase 1 (1℉) again.
e will not change.
b) In the dry mode, if the ambient temperature ≥17 (62℉), the compressor will start.
Then, the unit is controlled in the following manner: when the ambient temperature
≤15 (59℉), the compressor shuts down. When the ambient temperature rises to
be ≥17 (62℉), the compressor starts again. The start/stop of the compressor
meets the requirement for 3-minute protection time.
c). Under the fan mode, fan motor works while the compressor doesn't. Temperature
setting is in vain. The low fan speed is forced.
3.Timer setting
a) Upon start, press the Timer button to enter timed shutdown. Upon shutdown, press
this button to enter timed start. In the meanwhile, the timer indicator will illuminate.
b) Press the Timer button to enter the timing function (timed start/timed shutdown).
Adjust the up or down button to set the timing. The time will cycle in the order of 1 -
2-3-……24 -0-1 hours or 24 -23 -22 -……1 -0-24 hours. The
adjustment time of the timing function is relative time.
c) After timed start is set, once the timed start time is reached, the unit will start. In the
meanwhile, the timer indicator will extinguish and the ambient temperature is displayed.
d) After timed shutdown is set, once the timed shutdown time is reached, the unit will
shut down. In the meanwhile, the timer indicator will extinguish and the ambient temperature
is displayed.
e) Only the last setting of the timing function is valid.
f) ON/OFF operations caused by the button or remote control will clear all timing
settings.
g) Once the timing is determined, if the timer button is pressed once, it is possible to
query the remaining timed start/shutdown time. If the timer button is pressed twice
continuously within 5s, it is possible to cancel timing.
h). The up and down buttonscan be used to change the set value of the timer.
Two. Operation instructions of the remote control:
The operation instructions of the buttons of this simple remote control are as follows:
1. Power button: press this button to turn on/off the unit;
2. Timer button: upon shutdown, press this button to set timed start; upon start, press
this button to set timed shutdown.
3. High button: press this button to allow the unit to operate in the high fan speed state
(except in the dry and sleep modes);
4. Low button: press this button to allow this unit to operate in the low fan speed state;
5. Up button: press this button to increase the temperature and timing value;
6. Down button: press this button to decrease the temperature and timing value;
7. — F button: press this button to switch between the Celsius degree and Fahrenheit
degree;
8. Cool button: press this button to set this unit to operate in the cooling mode;
9. Fan button: press this button to set this unit to operate in the air supply mode;
10. Dry button: press this button to set this unit to operate in the dry mode;
11. Sleep mode: press this button to set this unit to operate in the sleep mode.
Three. Multiple protection functions:
1. Anti-freeze protection function:
Upon cooling, when the compressors operates continuously for more than 10
minutes, if the pipe temperature Tp is less than or equal to 34℉continuously for 20
seconds, the compressor and water spraying motor turn off, other loads operate and
LED displays E4, the unit initiates the anti-frost protection function and the buttons are
inactive (except the OFF button). Once the pipe temperature rises to exceed or equal
46℉, the protection is relieved, the original status is restored and the unit meets the
requirements for 3-minute delay protection of the compressor.
2. Full water protection function:
When the water in the water tray exceeds the alarm level, the unit will alarm
automatically and the full water indicator illuminates. In this case, you need to drain the
condensate in the unit; otherwise, the unit will shut down automatically after the buzzer
gives off 5 beeps. (For more information about the drain method, refer to the “Drain”). If
the unit is not shut down manually, the unit will be restored to the previous operating
status automatically once the water is fully drained. Or the power may be turned on
again to start the unit.
3. Delay protection function of the compressor
This unit offers restart protection for the compressor. Except that the compressor
may start immediately when the unit is energized for the first time, there is 3-minute
delay start protection after the compressor is shut down.
Water Drainage
1. Manual drain: (as shown in Figure 10)
1). Once the unit shuts down upon full water, turn off the power of the unit and then unplug
the power plug.
Note: move the unit carefully to avoid spillage of water in the water tray at the bottom
of the unit.
2). Put the vessel that holds water below the water outlet at the back of the unit.
3). Screw off the drain cap, unplug the water plug and water will flow into the vessel that
holds water automatically.
Note: 1. Protect the drain cap and water plug properly.
2. Tilt the unit slightly backward when draining.
3. If the vessel that holds water can not hold all water in the unit, before the
vessel that holds water is full of water, block the water outlet with the water