manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. CPS
  6. •
  7. Control Unit
  8. •
  9. CPS VORTECH MV13H3P5A User manual

CPS VORTECH MV13H3P5A User manual

Other CPS Control Unit manuals

CPS BlackMax User manual

CPS

CPS BlackMax User manual

CPS SVW User manual

CPS

CPS SVW User manual

CPS Pro-Set Workingman's 2 Valve Manifold User manual

CPS

CPS Pro-Set Workingman's 2 Valve Manifold User manual

Popular Control Unit manuals by other brands

Festo Compact Performance CP-FB6-E Brief description

Festo

Festo Compact Performance CP-FB6-E Brief description

Elo TouchSystems DMS-SA19P-EXTME Quick installation guide

Elo TouchSystems

Elo TouchSystems DMS-SA19P-EXTME Quick installation guide

JS Automation MPC3034A user manual

JS Automation

JS Automation MPC3034A user manual

JAUDT SW GII 6406 Series Translation of the original operating instructions

JAUDT

JAUDT SW GII 6406 Series Translation of the original operating instructions

Spektrum Air Module System manual

Spektrum

Spektrum Air Module System manual

BOC Edwards Q Series instruction manual

BOC Edwards

BOC Edwards Q Series instruction manual

KHADAS BT Magic quick start

KHADAS

KHADAS BT Magic quick start

Etherma eNEXHO-IL Assembly and operating instructions

Etherma

Etherma eNEXHO-IL Assembly and operating instructions

PMFoundations Attenuverter Assembly guide

PMFoundations

PMFoundations Attenuverter Assembly guide

GEA VARIVENT Operating	 instruction

GEA

GEA VARIVENT Operating instruction

Walther Systemtechnik VMS-05 Assembly instructions

Walther Systemtechnik

Walther Systemtechnik VMS-05 Assembly instructions

Altronix LINQ8PD Installation and programming manual

Altronix

Altronix LINQ8PD Installation and programming manual

Eaton Powerware Series user guide

Eaton

Eaton Powerware Series user guide

WAGO 750-407/040-000 manual

WAGO

WAGO 750-407/040-000 manual

Sony CCU-590 Operation manual

Sony

Sony CCU-590 Operation manual

Graco 25D614 instructions

Graco

Graco 25D614 instructions

Task Force Tips YE-RF-900 Instructions for installation, safe operation and maintenance

Task Force Tips

Task Force Tips YE-RF-900 Instructions for installation, safe operation and maintenance

Shini SPV-U Series manual

Shini

Shini SPV-U Series manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

OPEN
CLOSE
OPEN
CLOSE
VORTECH™ 4 VALVE
MANIFOLD
GENERAL SAFETY INSTRUCTIONS
ONLY QUALIFIED SERVICE PERSONNEL SHOULD OPERATE THIS UNIT. MOST STATES, COUNTRIES, ETC
MAY REQUIRE THE USER TO BE LICENSED. PLEASE CHECK WITH YOUR LOCAL GOVERNMENT AGENCY.
Danger- Avoid breathing refrigerant vapors and lubricant vapor or mist. Breathing high concentration levels
may cause heart arrhythmia, loss of consciousness, or even cause suffocation. Exposure may irritate eyes,
nose, throat, and skin. Please read the manufacturers Material Safety Data Sheet for further safety informa-
tion on refrigerants and lubricants.
Danger- EXPLOSION RISK. Use extreme caution when working with flammable refrigerants. Never use
this manifold with Oxygen.
Danger- EXPLOSION/RUPTURE RISK. DO NOT use this manifold with unregulated nitrogen, carbon diox-
ide or other very high pressure gasses. Unregulated gasses can cause components in a refrigeration system
to rupture. Severe Injury or Death can occur.
Caution- all hoses may contain liquid refrigerant under pressure. Contact with refrigerant may cause frost-
bite or other related injuries. Wear proper personal protective equipment such as safety goggles and gloves.
When disconnecting any hose, please use extreme caution.
None-Flutter Gauge /
Rugged metal housing
Sightglass
Large
Easy-to-Grab
Knobs
Anodized
Aluminum
Block Body
Protective Rubber
Gauge Boot
Front Calibration
Access Port
4 WAY MANIFOLD FUNCTION
1. The right end knob (red) will control the flow through the right end port.
2. The left end knob (blue) will control the flow through the left end port.
3. The front right hand knob (yellow) will control the flow through the right middle port port.
4. The front left side hand knob (green) will control the flow through the left middle port.
5. Low Pressure gauge measures pressure on the left end port with the left side valve closed.
6. High Pressure gauge measures pressure on the right end port with the right side valve closed.
OPEN
CLOSE
OPEN
CLOSE
COMPRESSOR
SUCTION
REFRIGERANT
CYLINDER
DISCHARGE
VACUUM
PUMP
D
A
LO
14
2
3
C
B
L
H
HI
OPERATING INSTRUCTIONS
I. TO PURGE HOSES WITH REFRIGERANT
GAS.
1.Connect hoses as shown with all valves
closed on MANIFOLD.
2. Loosely connect & hoses to
COMPRESSOR & service ports
respectively.
3. Open & valves on MANIFOLD.
4.Open valve on REFRIGERANT Tank.
5. Slowly open valve on MANIFOLD
until gas escapes from &
service valve connections.
6. Tighten & hose nuts on &
service valve connections.
II. TO MONITOR SYSTEM PRESSURES
A. CONNECTIONS
• Connect hoses as shown with all
valves closed on MANIFOLD.
• Open & service valves on
COMPRESSOR.
II. TO CHARGE SYSTEM WITH VAPOR ON
SUCTION SIDE
1. Connect hoses as shown with all
valves closed on MANIFOLD.
2. Purge hoses as in step I.
3. Open REFRIGERANT tank valve.
4.Open valve on MANIFOLD.
5. Open valve on MANIFOLD.
6.Open valve on MANIFOLD.
IV. TO EVACUATE SYSTEM
1. Connect hoses as shown with all
valves closed on MANIFOLD.
2. Start VACUUM pump.
3. Open valve on MANIFOLD.
4. Open & valve on MANIFOLD.
5. Open & service valves on
COMPRESSOR.
A B
1 2
C
H L
H H H H
L H
C
A
L
D
A B
L H
SERVICE PARTS LIST: 4V VVS MANIFOLDS
CPS P/N Items (qty.) Description 4V Models
MVXK 1,2,3,4,5,6 Black Knob w/covers w/screw MV4,MV9,MV12, MV13,
MVXTD 12,13 VVS Valve Repair Kit MV4,MV9,MV12, MV13,
MV4XRK 12(4), 13(4) 4V VVS Valve Repair Kit MV4,MV9,MV12, MV13,
MV4XHA 14 1/4 SAE, 3/8 SAE Hanger MV4,MV13,
MV9XHA 14 3/8 SAE Hanger MV9
MV12XHA 14 1/2-20,3/8 SAE Hanger MV12
MXMH 7 Hook Hanger MV4,MV9,MV12, MV13,
42-691 10 VVS Packing Nut MV4,MV9,MV12, MV13,
40-694 11 VVS Stem MV4,MV9,MV12, MV13,
40-147 8 1/4 SAE STR Fitting MV4,MV13,
40-137 8 1/2-20 UNC STR Fitting MV12
40-384 8 3/8 SAE STR Fitting MV9
40-625 9 3/8 SAE STR Fitting MV4,MV9,MV12, MV13,
6
3
2
1
10
11
12
13
9
8
8
1
1
7
5
4
8
2
14
WORLD HEADQUARTERS
1010 East 31st Street, Hialeah, Florida 33013, USA
Tel: 305-687-4121, 1-800-277-3808, Fax: 305-687-3743
e-mail: [email protected] www.cpsproducts.com
CPS CANADA
4605 Crysler Ave. Niagara Falls, Ontario L2E 3V6
Tel: 905-358-3124, Fax - 905-358-7187, 1-866-629-3895,
e-mail: [email protected]
CPS PRODUCTS N.V
Krijgsbaan 241, 2070 Zwijndrecht, Belgium
Tel: (323) 281 30 40, Fax: (323) 281 65 83, www.cpsproducts.be,
e-mail: [email protected]
CPS AUSTRALIA PTY. LTD.
109 Welland Avenue, Welland, South Australia 5007
Tel: +61 8 8340 7055, Fax: +61 8 8340 7033
e-mail: [email protected]
CPS ASIA
56A Kallang Pudding Road #02-00 Singapore Road 349329
Tel: (65) 68461056, Fax: (65) 68461054
e-mail: [email protected]
#70-907