Crown SX-5G3 User manual

MANUAL 10301R1
INSTALLATION & OPERATION
MANUAL
Gas Convection Steamer
SX-* SX-* SX-*
WARNING
Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read
the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.
IMPORTANT FOR FUTURE REFERENCE
Please complete this information and retain this
manual for the life of the equipment:
Model #: ___________________________
Serial #: ___________________________
Date Purchased: ____________________
CROWN FOOD SERVICE EQUIPMENT
A Middleby Company
70 Oakdale Road, Downsview (Toronto) Ontario, Canada, M3N 1V9
Telephone: 919-762-1000 www.crownsteamgroup.com
Printed in Canada

INSTALLATION AND OPERATION MANUAL, GAS FIRED STEAMER,
MODELS SX-5G3, SX-7G3, SX-10G3
Intended for commercial use only. Not for household use.
IMPORTANT NOTES FOR INSTALLATION AND OPERATION
This is the safety alert symbol. It is used to alert you to potential
personal injury hazards. Obey all safety messages that follow this
symbol to avoid possible injury or death.
WARNING: Improper installation, operation, adjustment, alteration,
service or maintenance can cause property damage, injury or death.
Read the installation, operating and maintenance instructions
thoroughly before installing, operating or servicing this equipment.
FOR YOUR SAFETY: Do not store or use gasoline or other
flammable vapours and liquids in the vicinity of this or any other
appliance.
PURCHASER: Instructions to be followed in the event that the
operator of this appliance smells gas must be posted in a prominent
location. This information shall be obtained by consulting the local
gas supplier.
Keep the appliance area free and clear from combustibles.
Do not obstruct the flow of combustion and ventilation air.
Adequate clearances must be maintained for servicing and proper operation.
Do not attempt to operate this unit in the event of a power failure.
This manual should be retained for future reference.
Part No. 10301R1 2 2018-12-11

INSTALLATION AND OPERATION MANUAL, GAS FIRED STEAMER,
MODELS SX-5G3, SX-7G3, SX-10G3
TABLE OF CONTENTS
DESCRIPTION PAGE
1.0 Service Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.0 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3.0 Performance Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
4.0 Operation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
SERVICE
5.0 Periodic Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
6.0 Deliming Procedure .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
7.0 Troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Part No. 10301R1 3 2018-12-11

INSTALLATION AND OPERATION MANUAL, GAS FIRED STEAMER,
MODELS SX-5G3, SX-7G3, SX-10G3
1.0 SERVICE CONNECTIONS
Part No. 10301R1 4 2018-12-11

INSTALLATION AND OPERATION MANUAL, GAS FIRED STEAMER,
MODELS SX-5G3, SX-7G3, SX-10G3
1.0 SERVICE CONNECTIONS (Continued)
Part No. 10301R1 5 2018-12-11

INSTALLATION AND OPERATION MANUAL, GAS FIRED STEAMER,
MODELS SX-5G3, SX-7G3, SX-10G3
2.0 INSTALLATION
GENERAL
Installation must conform with local codes, or in the absence of local codes, with the National
Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code,
CSA B149.1, as applicable.
1. The appliance and its individual shut off valve must be disconnected from the gas
supply piping system during any pressure testing of that system at pressures in
excess of ½ psi (3.5 kPa).
2. The appliance must be isolated from the gas supply piping system by closing its
individual manual shut off valve during any pressure testing of the gas supply
piping system at test pressures equal to or less than ½ psi (3.5 kPa).
Electrical grounding must be provided in accordance with local codes, or in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA
C22.2, as applicable.
Ventilation must be provided in accordance with local codes, or in the absence of local codes,
with ANSI/NFPA 96 Standard for Ventilation and Fire Protection of Commercial Cooking
Operations.
WARNING: Electrical grounding instructions - units equipped with a
three-prong (grounding) plug for your protection against shock
hazard and should be plugged directly into a properly grounded
three-prong receptacle. Do not cut or remove the grounding prong
from this plug. (120 volt units only).
WIRING DIAGRAM FOR APPLIANCE IS LOCATED ON RIGHT HAND SIDE PANEL OF THE
COOKER CABINET.
NOTICE: If this equipment is being installed at over 2,000 feet altitude and was
not so specified on order, contact service department. Failure to install with
proper orifice sizing may void the warranty.
Part No. 10301R1 6 2018-12-11

INSTALLATION AND OPERATION MANUAL, GAS FIRED STEAMER,
MODELS SX-5G3, SX-7G3, SX-10G3
2.0 INSTALLATION (Continued)
2.1 EXHAUST FANS AND CANOPIES:
Canopies are set over ranges, ovens, kettles, etc., for ventilation purposes. It is recommended
that a canopy extend 6" past appliance and be located 6' 6" from the floor. Filters should be
installed at an angle of 45 degrees or more with the horizontal. This position prevents dripping
of grease and facilitates collecting the run-off grease in a drip pan, usually installed with the
filter. A strong exhaust fan tends to create a vacuum in the room and may interfere with burner
performance or may extinguish pilot flames. Makeup air openings approximately equal to the
fan area will relieve such vacuum. In case of unsatisfactory performance on any appliance,
check with the exhaust fan in the “OFF” position.
2.2 WALL EXHAUST FAN:
The exhaust fan should be installed at least two feet above the vent opening at the top of the
unit.
2.3 CLEARANCES:
Adequate clearance must be provided in aisle and at the side and back. Adequate clearances
for air openings into the combustion chamber must be provided, as well as for serviceability for
use on noncombustible floors. Minimum clearance from combustible and noncombustible
construction, 3 inches on left side, 8 inches on right side and 6 inches from back.
WARNING: These procedures must be followed by qualified
personnel or warranty will be voided. An open gap floor drain is
required immediately below the appliance drain.
TO INSTALL:
1. Uncrate carefully. Report any hidden freight damage to the freight company immediately.
2. Set the unit in place. Be certain to maintain the minimum clearances from combustibles
and non-combustibles.
3. Level appliance using spirit level. Should flanged adjustable feet be provided, anchor to
floor using proper anchoring devices.
4. Seal bolts and flanged feet with Silastic or other equivalent compound.
5. Be certain to leave adequate clearances for cleaning, maintenance and service.
Part No. 10301R1 7 2018-12-11

INSTALLATION AND OPERATION MANUAL, GAS FIRED STEAMER,
MODELS SX-5G3, SX-7G3, SX-10G3
INSTALLATION
GAS CONNECTION:
1. The Serial and Rating Plate on the unit indicates the type of gas your unit is equipped to
burn. DO NOT connect to any other gas type.
2. A 3/4" NPT line is provided at rear for the connection. Each compartment is equipped with
an internal pressure regulator which is set at 3.5" W.C. manifold pressure for natural gas
and 9.0" W.C. for propane gas. Use 1/8" pipe tap on the burner manifold for checking
pressure.
An adequate gas supply is imperative. Undersized or low pressure lines will restrict the volume
of gas required for satisfactory performance. A steady supply pressure, between 6" W.C. and
14" W.C. for natural gas and between 11" W.C. and 14" W.C. for propane gas is
recommended. With all units operating simultaneously, the manifold pressure on all units
should not show any appreciable drop. Fluctuations of more than 25% on natural gas and 10%
on propane gas will create problems, affecting burner operation. Contact your gas company for
correct supply line sizes.
Purge the supply line to clean out any dust, dirt or other foreign matter before connecting the
line to the unit. Use pipe joint compound which is suitable for use with Propane on all threaded
connections. A manual gas shut off valve for each compartment is supplied with the unit.
Test pipe connections thoroughly for gas leaks.
WARNING: Never use an open flame to check for gas leaks. Check
all connections for leaks using soapy water before use.
NOTE: If applicable, the vent from the gas appliance pressure regulator shall
be installed to the outdoors in accordance with local codes or, in the absence
of local codes, with the National Fuel Gas Code, ANSI Z223.1 or the Natural
Gas Installation Code CAN/CGA-B149.1 or the propane installation code,
CAN/CGA-B149.2, as applicable.
Part No. 10301R1 8 2018-12-11

INSTALLATION AND OPERATION MANUAL, GAS FIRED STEAMER,
MODELS SX-5G3, SX-7G3, SX-10G3
DRAIN CONNECTIONS FIGURE 1
The drain connection must be 1̽" (37.5
mm) IPS down, preferably with one or two
elbows only, maximum length 6 feet (1830
mm) horizontal and piped to an open gap
type drain. Drain pipe should be copper.
DO NOT use PVC pipe – PVC pipe may
lose its rigidity or glue may fail.
CAUTION: To avoid
injury or damage to the
steamer, do not connect
solidly to any drain
connection.
FIGURE 2
Part No. 10301R1 9 2018-12-11

INSTALLATION AND OPERATION MANUAL, GAS FIRED STEAMER,
MODELS SX-5G3, SX-7G3, SX-10G3
WATER QUALITY
The water supply connected to the steam generator should meet the following guidelines:
Failure to comply with Water Quality Statement on page 4 may void the warranty.
Water supplies vary from one location to another. Other factors affecting steam generation are
iron content, chlorides, and dissolved gasses. A local water treatment specialist should be
consulted before installing any steam generating equipment.
Untreated water contains scale producing minerals which can precipitate onto the surfaces in
the generator. Due to the temperatures in the generator, the minerals can bake onto the
surfaces and components. This can result in early component failure and reduced product life.
ELECTRICAL CONNECTION
WARNING: Do not connect the steamer to the electrical supply until
after the gas connection has been made.
120 VAC-60 Hz-Single Phase
Units with this electrical rating are factory supplied with a three-wire cord and three-prong plug
which fits any standard NEMA 5-15R 125 VAC, three-prong grounded receptacle. A separate
15 amp supply is needed for each unit.
PLUMBING CONNECTIONS
WARNING: Plumbing connections must comply with applicable
sanitary, safety and plumbing codes.
Part No. 10301R1 10 2018-12-11

INSTALLATION AND OPERATION MANUAL, GAS FIRED STEAMER,
MODELS SX-5G3, SX-7G3, SX-10G3
PLUMBING CONNECTIONS (Continued)
The water supply inlets are provided with 3/8" (10 mm) compression fittings for 3/8" O.D.
copper tubing. The water supply line pressure should be 25 - 50 psi (170-345 kPa) for each
line. The water supply to the generator tank(s) separate from the water supply to the cooling
system where steam is condensed before entering the drain line.
Install line strainers (not provided). A manual shutoff valve for each supply line must be
provided convenient to the steamer.
Treated water feeding the boiler inlet supply is recommended, and untreated water feeding the
condensing water inlet. Inlets are labelled on the back of the steamer
COLD WATER CONDENSER
The steamer is equipped with a cold water condenser in the rear of the cooking chamber which
helps to condense the steam prior to discharge into drain. The steamer freely vents itself by
the negative pressure created by the condensate water drainage. This negative pressure
prevents steam leakage around the door gasket and helps draw the steam through the cooking
compartment. Steam leakage at the door may indicate a plugged or improperly installed drain.
WATER CONDITIONING
It is important that the water supply connected to this steamer be softened to no more than 2.0
grains of hardness and have a pH of 6 to 7.5. This degree of hardness can be easily obtained
with the use of a properly maintained water softener. The use of a water meter will determine
the water consumption and when the water softener needs regeneration or recharging. Failure
to comply with these water condition standards may void the warranty.
Untreated water contains scale producing minerals which can precipitate onto the surfaces in
the generator. Due to the temperatures in the generator, the minerals can bake onto the
surfaces and components. This can result in early component failure and reduced product life.
Water level probes become coated with scale. Scale will bridge across the probe insulator from
the metal extension which senses the water level in the generator. Once this scale becomes
wet, the water level control is unable to maintain the proper water level in the generator.
STRAINERS and FILTERS will NOT remove minerals from the water.
Part No. 10301R1 11 2018-12-11

INSTALLATION AND OPERATION MANUAL, GAS FIRED STEAMER,
MODELS SX-5G3, SX-7G3, SX-10G3
3.0 PERFORMANCE CHECK
Once the steamer is installed and all mechanical connections have been made, thoroughly test
the steamer before operation.
1. Check that proper water, drain and electrical and gas connections have been made.
2. Turn main power switch ON. After approximately 12 minutes, the “READY” light should
come on, indicating that the water temperature is 205º Fahrenheit (97º Celsius).
3. Check that “Ignition” light comes on when the pilot burner is on.”
4. When the “READY” light comes on, set timer to the “5 minute” position. With door open,
observe that no steam is entering the compartment and that the “COOKING” light is OFF.
5. Close compartment door. The COOKING light should now be illuminated and steam should
be heard entering the compartment after about 45 seconds. “READY” light is OFF.
6. Ensure that water from cold water condenser is flowing through the drain line.
7. Open compartment door and observe that steam supply to chamber is cut off. “READY”
light should again come “ON” as “COOKING” light goes “OFF.”
8. Close compartment door and let cooking cycle finish. When the timer returns to “0"
position, a buzzer will sound signalling the end of the cooking cycle. Buzzer must be
manually turned off by setting the timer to its “OFF” position.
Part No. 10301R1 12 2018-12-11

INSTALLATION AND OPERATION MANUAL, GAS FIRED STEAMER,
MODELS SX-5G3, SX-7G3, SX-10G3
4.0 OPERATION INSTRUCTIONS
WARNING: The steamer and its parts are hot. Use care when
operating, cleaning or servicing the steamer. The cooking
compartment contains live steam. Stay clear when opening door.
Your steamer has been factory set when “ON” to maintain water temperature during the
READY phase at approximately 205º Fahrenheit (97º Celsius) just below water boiling point.
CONTROLS
Ready Pilot Light
When lit, indicates steam chamber has reached 205º Fahrenheit (97º Celsius) and is ready for
the cooking cycle.
Cooking Pilot Light
When lit, indicates that a cooking cycle is in progress.
Ignition Light
When lit, indicates that pilot burner has been ignited.
Timer
Set the cooking time (0 to 60 minutes) - steam cooking will begin when the door is closed. The
cooking cycle will be interrupted if the door is open during the cooking cycle; resume cooking by
closing the door.
MAIN POWER SWITCH
On
The generator will automatically fill and begin heating to the pre-set temperature.
Off
The generator will drain.
Part No. 10301R1 13 2018-12-11

INSTALLATION AND OPERATION MANUAL, GAS FIRED STEAMER,
MODELS SX-5G3, SX-7G3, SX-10G3
4.0 OPERATION INSTRUCTIONS (Continued)
Delime
Closes the drain valve while CLR liquid is being poured into the generator during the Delime
procedure.
WARNING: In the event of main burner ignition failure, a 5 minute
purge period must be observed prior to re-establishing ignition
source. If so equipped, some units will automatically re-attempt
ignition.
WARNING: In the event a gas odour is detected, shut down
equipment at the main shut off valve and contact the local gas
company or gas supplier for service.
LIGHTING
1. Ensure power, gas and water supply is on.
2. Turn power switch “ON.”
3. Generator tank will begin filling with water.
4. Once water level has been reached, the ignition light should come on and remain on
throughout the operation of the appliance.
5. When “READY” light comes ON the steamer is ready for use.
Part No. 10301R1 14 2018-12-11

INSTALLATION AND OPERATION MANUAL, GAS FIRED STEAMER,
MODELS SX-5G3, SX-7G3, SX-10G3
4.0 OPERATION INSTRUCTIONS (Continued)
SHUTDOWN
STAND BY
1. Set timer to “OFF” position and leave door slightly open.
COMPLETE SHUTDOWN
1. Set timer to “OFF” and turn power switch “OFF.” Generator will drain automatically.
2. Turn water supply “OFF.”
3. Turn gas supply “OFF.”
4. Disconnect power supply.
NOTE: The cooking compartments are operated independently of each other.
Each has its own gas and water supply and generator tank.
Part No. 10301R1 15 2018-12-11

INSTALLATION AND OPERATION MANUAL, GAS FIRED STEAMER,
MODELS SX-5G3, SX-7G3, SX-10G3
4.0 OPERATION INSTRUCTIONS (Continued)
STEAM COOKING
Your steamer efficiently cooks vegetables or other foods for immediate serving. Steam cooking
should be carefully time controlled. Keep hot food holding time to a minimum to produce the
most appetizing results. Prepare small batches, cook only enough to start serving, then cook
additional amounts to meet demand. Separate frozen foods into smaller pieces to allow more
efficient cooking.
Use a pan cover for pre-cooked frozen dishes that cannot be cooked in the covered containers
in which they are packed if they require more than 15 minutes of cooking time. When cover is
used, approximately one-third additional cooking time is necessary.
Cooking time for frozen foods depends on amount of defrosting required. If time permits, allow
frozen foods to partially thaw overnight in a refrigerator. This will reduce their cooking time.
PREPARATION
Prepare vegetables, fruits, meats, seafood and poultry normally by cleaning, separating,
cutting, removing stems, etc. Cook root vegetables in a perforated pan unless juices are being
saved. Liquids can be collected in a solid 12" x 20" pan placed under a perforated pan.
Perforated pans are used for frankfurters, wieners and similar items when juices do not need to
be preserved. Solid pans are good for cooking puddings, rice and hot breakfast cereals.
Vegetables and fruits are cooked in solid pans in their own juices. Meats and poultry are
cooked in solid pans to preserve their own juices or to retain broth. Canned foods can be
heated in their opened cans (cans placed in 12" x 20" solid pans) or the contents may be
poured into solid pans.
PAN
The steamer compartment is designed to accept combinations of the pan of 12" x 20" (either
solid or perforated) as shown on the following Table 1.
TABLE 1
DEPTH
OF PAN
NUMBER OF PANS
SX-5G3 SX-7G3 SX-10G3
Top
Compartment
Bottom
Compartment
Top
Compartment
Bottom
Compartment
1" 10 6 8 10 10
2½” 53455
4" 32233
6" 21222
Part No. 10301R1 16 2018-12-11

INSTALLATION AND OPERATION MANUAL, GAS FIRED STEAMER,
MODELS SX-5G3, SX-7G3, SX-10G3
5.0 PERIODIC MAINTENANCE
NOTICE: As a safety precaution, disconnect the power supply
during cleaning or servicing.
CLEANING
At the end of each day, or between cooking cycles if necessary:
1. Turn main power switch OFF.
2. Remove pans and racks from compartment and wash in sink.
3. Wash compartment interior with clean water.
4. Use warm soapy water with a cloth or sponge to clean exposed bead of door gasket, rinse
with warm clear water and wipe with a dry cloth.
Wipe surfaces which touch door gasket with a cloth or sponge and warm soapy water, rinse
with warm clear water and wipe with a dry cloth. Do not apply food oils or petroleum
solvents or lubricants directly to door gasket or surfaces which touch door gasket.
5. Remove drain screens from inside compartment drains. Using a plastic bottle brush and
mild detergent, clean inside the drain opening ensuring there is no food residue or
blockage. Clean the drain screen and replace in its original position.
6. Leave door slightly open when steamer is not in use.
CAUTION: Do not use cleaning agents that are corrosive.
NOTICE: Contact the factory, the factory representative or a local service
company to perform maintenance and repairs should the appliance
malfunction. Refer to warranty terms.
Part No. 10301R1 17 2018-12-11

INSTALLATION AND OPERATION MANUAL, GAS FIRED STEAMER,
MODELS SX-5G3, SX-7G3, SX-10G3
5.0 PERIODIC MAINTENANCE (Continued)
CLEANING
Weekly, or more often if necessary:
1. Clean exterior with a damp cloth and polish with a soft dry cloth.
2. Use a non-abrasive cleaner to remove discolorations.
3. Clean around burner air mixer and orifice if lint has accumulated. Side cover must be
removed to clean this area.
Monthly:
1. Clean around burner air mixers, louvered panels if grease or lint has accumulated.
Following daily and periodic maintenance procedures will enhance long-life for your equipment.
Climatic conditions - salt air - may require more thorough and frequent cleaning otherwise the
life of the equipment could be adversely affected.
It is NOT RECOMMENDED to use cleaning agents that are corrosive.
Use of cleaning agents that contain chloride, acids or salts which are corrosive may cause
pitting and corrosion when used over a period of time; this will reduce the life of the appliance.
Should pitting or corrosion occur, this is not covered by warranty.
Follow the recommended cleaning instructions. Use a mild detergent, warm water and rinse
thoroughly.
NEVER SPRAY WATER INTO ELECTRIC CONTROLS.
Part No. 10301R1 18 2018-12-11

INSTALLATION AND OPERATION MANUAL, GAS FIRED STEAMER,
MODELS SX-5G3, SX-7G3, SX-10G3
MAINTENANCE
STAINLESS STEEL
To remove normal dirt, grease or product residue from stainless steel, use ordinary soap and
water (with or without detergent) applied with a sponge or cloth. Dry thoroughly with a clean
cloth. Never use vinegar or any corrosive cleaner.
To remove grease and food splatters or condensed vapours that have baked on the equipment,
apply cleanser to a damp cloth or sponge and rub cleanser on the metal in the direction of the
polishing lines on the metal. Rubbing cleanser as gently as possible in the direction of the
polished lines will not mar the finish of the stainless steel. NEVER RUB WITH A CIRCULAR
MOTION.
Soil and burnt deposits which do not respond to the above procedure can usually be removed
by rubbing the surface with SCOTCH-BRITE scouring pads or STAINLESS scouring pads. DO
NOT USE ORDINARY STEEL WOOL as any particles left on the surface will rust and further
spoil the appearance of the finish. NEVER USE A WIRE BRUSH, STEEL SCOURING PAD
(EXCEPT STAINLESS), SCRAPPER, FILE OR OTHER STEEL TOOLS. Surfaces which are
marred collect dirt more rapidly and become more difficult to clean. Marring also increases the
possibility of corrosive attack. Refinishing may then be required.
TO REMOVE HEAT TINT
Darkened areas sometimes appear on the stainless steel surface where the area has been
subjected to excessive heat. These darkened areas are caused by thickening of the protective
surface of the stainless steel and are not harmful. Heat tint can normally be removed by the
foregoing, but tint which does not respond to this procedure calls for a vigorous scouring in the
direction of the polish lines using SCOTCH-BRITE scouring pads or a STAINLESS scouring
pad in combination with a powdered cleanser. Heat tint action may be lessened by not applying
or by reducing heat to equipment during slack periods.
REMOVAL OF SCALE DEPOSITS
It is recommended that your steamer be delimed once a month, or more often if necessary.
Should your steamer develop a heavy build-up of lime scale deposits, use the CLR
TREATMENT KIT available from your authorized servicer.
Before beginning deliming procedures, ensure that the water is not overflowing into the cooking
compartment.
Part No. 10301R1 19 2018-12-11

INSTALLATION AND OPERATION MANUAL, GAS FIRED STEAMER,
MODELS SX-5G3, SX-7G3, SX-10G3
6.0 DELIMING PROCEDURE
WARNING: Read and follow instructions on the CLR bottle. Use
plastic or rubber gloves to avoid skin contact. If CLR comes in
contact with skin, rinse with clean water.
1. Drain steam generator by setting power switch to “OFF.” Set cooking timer to 0.
2. Turn power switch to DELIME. Keep the doors closed.
3. Unscrew brass deliming plug on right side of steamer. Insert hose in hole of port. Pour 20
ounces of solution into generator slowly to avoid spillage. Remove hose. Screw deliming
plug back so it seals tightly. Turn power switch to on. (If there is no deliming plug on the
side of the steamer, check with your local service agency for proper deliming instructions of
your unit.)
4. Allow steamer to remain in ready cycle for ½ hour, then turn power switch “OFF” and allow
generator to drain.
5. Flush cycle. Turn power switch to “ON.” When ready light comes on, switch to “OFF” to
fully drain the generator. Repeat this step three times to completely flush generator.
6. Clean exterior and interior. Use a mild solution of soap and water. Rinse with clean water.
Dry with a soft cloth. LEAVE COMPARTMENT DOOR OPEN WHEN NOT IN USE.
The steamer is now ready for use. Turn off for overnight shutdown.
Part No. 10301R1 20 2018-12-11
This manual suits for next models
2
Table of contents
Other Crown Kitchen Appliance manuals