PH-1A
SINGLE CHANNEL
BATTERY OR AC POWERED
PHANTOM POWER SUPPLY
T
he Crown®PH-1A is a single-channel,
battery- or AC-powered phantom
power supply for condenser microphones.
Battery power provides 17V phantom and AC
power provides 24V phantom.
The unit can be AC powered by using the Crown
PS-24 AC/DC adaptor (not included). This
adaptor plugs into a 120V AC wall outlet and
provides 24V DC to the PH-1A.
When using external power, the PH-1A provides
+24V DC nominal loaded voltage on pins 2 and
3 with respect to pin 1 of the microphone input
connector.
With battery operation, the PH-1A provides
+17V DC nominal loaded voltage. “Loaded
voltage” is the phantom voltage available with a
microphone plugged in.
The PH-1A includes sufficient hum filtering for
extremely quiet operation and is transformer
isolated. If AC power fails, the batteries auto-
matically take over.
The rugged steel and aluminum chassis is de-
signed to withstand daily abuse in professional
applications.
Operation
To use your phantom supply, follow this pro-
cedure:
1. For AC power, plug the Crown PS-24 AC/DC
adaptor into an AC outlet providing 120 VAC, 60
Hz. Plug the 1/8 inch (3.5 mm) phone plug from
the AC/DC adaptor into the 1/8 inch (3.5 mm)
phone jack in the phantom supply.
2. For battery power, unscrew the two large
captive screws on the underside of the phantom
supply; open the chassis, and install two 9V
alkaline batteries (Duracell MN1604 or equiva-
lent). Replace the cover.
3. Plug the cable from your microphone into the
MIC IN connector.
4. Plug the cable going to the input of your
mixer or recorder into the OUTPUT connector.
This cable can be unbalanced because the phan-
tom supply is transformer isolated.
5. To prevent ground loops, be sure that the
phantom supply is resting on its rubber feet.
6. To avoid draining the batteries after use,
unplug the mic cables and unplug the AC/DC
adaptor from the phantom supply. There is no
battery drain when all cables are unplugged
from the supply.
Specifications
Phantom voltage supplied: 24V with AC
powering; 17V with battery power. Each volt-
age is nominal loaded voltage on pins 2 and
3 with respect to pin 1 of microphone input
connector.
Number of channels: 1.
Microphone input connector: Female 3-pin
professional audio connector (XLR-type).
Output connector: Male 3-pin professional
audio connector (XLR-type).
DC power input connector: 1/8 inch (3.5 mm)
phone jack, positive tip.
AC/DC adaptor: Use Crown PS-24 AC/DC adap-
tor (not included). 120V AC input, 24V to 31V
output, 1/8 inch (3.5 mm) phone plug output
connector with positive tip.
Battery powering: Two 9V alkaline cells
(Duracell MN1604 or equivalent). Batteries
not included.
Battery life: 525/I hours, where I = current
drain of microphone in mA. 350 hours typi-
cal.
Hum filtering (inside phantom supply): 50 dB
at 60 Hz; 62 dB at 120 Hz.
Dimensions: 5.0 x 2.325 x 1.750 inch LWH
(12.7 cm x 5.91 cm x 4.44 cm).
Weight: 1¼ lb. (0.57 kg).
Optional accessory: 24V AC/DC adaptor,
Crown model PS-24.
J1
+
PH-1A Schematic
Features
Supplies a single channel of phantom
power to a condenser microphone
Powered by internal 9V batteries or external
24V power supply
Supplies 17V with battery power and 24V
with AC power
Rugged construction for professional
use
If AC power fails, the batteries automati-
cally take over
Quiet, transformer isolated
Crown International
1718 W. Mishawaka Rd.
Elkhart, IN 46517-9439
TEL: 574-294-8000
FAX: 574-294-8FAX
www.crownaudio.com
©2007 Crown Audio®, Inc. Specifications subject
to change without prior notice. Latest information
available at www.crownaudio.com. Crown and
Crown Audio are registered trademarks of Crown
International. Printed in U.S.A.
11/07 103292-8A
Loaded Phantom Voltage
When you plug a microphone into a phantom
power supply, the supply voltage drops due
to the load of the microphone. The higher the
current drain of the microphone, the more the
voltage drops.
The loaded phantom voltage is the phantom
voltage available when a microphone is plugged
into the phantom supply. You can calculate
the loaded phantom voltage for the PH-1A as
described below:
For AC powering, the loaded phantom voltage
is:
EL= EU- RI
where
EL= loaded phantom voltage
EU= unloaded phantom voltage (30.7V with
Crown PS-24 AC/DC adaptor)
R = 983 ohms (internal resistance of PH-1A
when used with Crown PS-24 AC/DC adaptor)
I = current drain of microphone in amperes.
For battery powering, the loaded phantom
voltage is:
EL= EU- RI
where
EL= loaded phantom voltage
EU= unloaded phantom voltage (18V with two
9V batteries)
R = 743 ohms (internal resistance of PH-1A
when used with battery powering)
I = current drain of microphone in amperes.
Architects’ and Engineers’ Specifications
The model shall be the Crown PH-1A. It shall
be a single-channel, battery or AC powered,
17- or 24-volt DC phantom power supply for
condenser microphones.
With AC power, the supply shall provide 24V
DC nominal loaded voltage on pins 2 and 3 with
respect to pin 1 of the microphone input con-
nector. With battery power, it shall provide 17V
DC nominal loaded voltage.
The supply shall include sufficient hum filter-
ing for extremely quiet operation, and shall be
transformer isolated. If AC power fails, the bat-
teries shall automatically take over. The Crown
model PH-1A is specified.
Warranty
Crown professional microphones are guaran-
teed against malfunction for a period of three
years from date of original purchase. See
enclosed warranty sheet for additional informa-
tion.
Service
If the unit fails to operate, plug the AC/DC adap-
tor into a 120V AC power outlet and measure its
DC output voltage between the tip and sleeve of
the 1/8 inch (3.5 mm) phone plug. You should
measure at least 24V DC (approximately 31V
DC for the Crown model PS-24 AC/DC adaptor).
If not, return the model PS-24 AC/DC adaptor to
Crown’s Service Department.
If the AC/DC adaptor is working correctly, plug
it into the phantom supply. Measure the DC
voltage between pins 2 and 1 of the microphone
input connector. With no microphone plugged
in, you should measure at least 24V DC (ap-
proximately 30.7V DC with Crown model PS-24
AC/DC adaptor). If not, return the PH-1A phan-
tom supply to Crown’s Service Dept.
If both the AC/DC adaptor and phantom supply
are working correctly, check your microphone
cables and batteries.
Also check your microphone data sheet under
“operating voltage” to make sure it will operate
on the voltage supplied by the PH-1A.
If service is required, return the unit in its origi-
nal packaging to: Crown Factory Service, 1718
West Mishawaka Road, Elkhart, IN 46517-
9439. A Service Return Authorization (SRA) is
required for product being sent to the factory
for service. An SRA can be completed online
at www.crownaudio.com/support/
factserv.htm.
For further assistance or technical support call
800-342-6939.
PH-1A

Other Crown Power Supply manuals

Crown PH-4B User manual

Crown

Crown PH-4B User manual

Crown PH-1A User manual

Crown

Crown PH-1A User manual

Popular Power Supply manuals by other brands

Tetra GEPS24-100U-TT installation guide

Tetra

Tetra GEPS24-100U-TT installation guide

Perle IDPS-48-240-XT Hardware installation guide

Perle

Perle IDPS-48-240-XT Hardware installation guide

Altronix ALTV244UL3 Series installation guide

Altronix

Altronix ALTV244UL3 Series installation guide

Vertiv NetSure7100 Series user manual

Vertiv

Vertiv NetSure7100 Series user manual

Accuris myVolt Mini operating manual

Accuris

Accuris myVolt Mini operating manual

Xantrex XPower Powerpack 400 Plus, 400 R owner's guide

Xantrex

Xantrex XPower Powerpack 400 Plus, 400 R owner's guide

ABB ACS880-304 +A018 Hardware manual

ABB

ABB ACS880-304 +A018 Hardware manual

Palmer PWT12IEC user manual

Palmer

Palmer PWT12IEC user manual

Harman Martin DMX PowerPort 375 Series user manual

Harman

Harman Martin DMX PowerPort 375 Series user manual

StarTech.com ATXPOW350PRO instruction manual

StarTech.com

StarTech.com ATXPOW350PRO instruction manual

Savant PKG-EMKIT1P-00 Wiring guide

Savant

Savant PKG-EMKIT1P-00 Wiring guide

hager TXA 111 manual

hager

hager TXA 111 manual

EFOY Pro 800 Firmware Guide

EFOY

EFOY Pro 800 Firmware Guide

Extron electronics PS Series Specification sheet

Extron electronics

Extron electronics PS Series Specification sheet

Altronix AL100UL quick start guide

Altronix

Altronix AL100UL quick start guide

Enterasys C2RPS-SYS installation guide

Enterasys

Enterasys C2RPS-SYS installation guide

AFi PSR-2 instruction manual

AFi

AFi PSR-2 instruction manual

Altronix AL300ULXJG installation guide

Altronix

Altronix AL300ULXJG installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.