manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. CyberPower
  6. •
  7. UPS
  8. •
  9. CyberPower CSN75A12V3-G User manual

CyberPower CSN75A12V3-G User manual

User’s Manual for
CyberShield
CSN75A12V3-G
CyberShield UPSs are designed to provide a local power solution for
cable telephony, wireless local loop (WLL), and fiber to the home
(FTTH) broadband equipment.
IMPORTANT SAFETY WARNINGS
(SAVE THESE INSTRUCTIONS)
This manual contains important instructions regarding the installation and operation of this device.
Read this manual thoroughly before attempting to unpack , install or operate this device.
CAUTION! The battery can energize hazardous live parts inside even when the AC input power is
disconnected.
CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity
controlled indoor area, free of conductive contaminants. (Please see specifications for
acceptable temperature and humidity range).
CAUTION! To reduce the risk of electric shock, do not remove the cover, except to service the
battery. No user serviceable parts inside, except for the battery.
CAUTION! To avoid electric shock, turn off the unit and unplug it from the AC power source before
servicing the battery or installing a computer component.
ENCLOSURE INSTALLATION
Carefully follow these instructions during installation of this device:
1.) Carry out the installation in a safe area that is free of excessive dust and has adequate airflow.
2.) Screws must be appropriate for total weight of the UPS and the mounting surface material.
3.) Do not operate the UPS where the temperature and humidity are outside the specified limits.
(Refer to specification in this manual.)
BATTERY REPLACEMENT
This battery is hot-swappable. As long as utility power is on , you may leave the UPS and connected
equipment on while replacing a new battery.
Once the battery is disconnected, the connected equipment is not protected from power
outages.
Deliver spent batteries to a recycling facility or ship to the manufacturer in the
replacement battery packing material.
WARNING INDICATOR
OPERATION
Connect: Equipment and Power
Step1. Plug the UPS power cord into the utility power cord inlet
Step2. Plug the UPS power cord into the wall outlet.
The UPS battery charges when it is connected to utility power. The battery charges
fully during the first 24 hours of normal operation. Do not expect full battery run
capability during this initial charge period.
COLD START
The cold start feature is for applying power to the UPS and connected equipment when the UPS is
off and there is no utility power. Before using the cold start feature, please make sure the battery is
charged. To start the cold start feature, press the recessed cold start button with a small pointed
object.
UPS is on utility power.
UPS is on battery power.
DC output power is provided by the battery or
utility power.
The battery is not connected or the battery
needs to be replaced.
Green
Yellow
Green
Red
Indicator
Step 1:
a. Remove the battery cover.
Step 2:
a. Unstrap strap from battery.
b. Slide battery off of the
shelf.
c. Disconnect battery cable
connector at chassis end.
Step 3:
a. Use the enclosed installation template to
mark an installation location for the unit.
b. Mount the unit on the wall with 2 mounting
screws into the keyhole slots.
c. Tighten the screws to secure the units.
d. Connect the battery connector and replace
the battery back.
Step 1:
a. Remove the battery cover.
Step 2:
a. Loosen the battery strap.
b. Disconnect battery cable connector
to remove battery.
c. Replace with new battery and
re-connect the battery connector.
Step 3:
a. Tighten the battery strip and
close the battery cover.
Front Panel
AC
OUTPUT
BATTERY
Note: please always mount the unit on the wall when it is working.
AC OUTPUT BATTERY
Back Panel
CAUTION:
FOR USE IN A CONTROLLED ENVIRONMENT.
REMOVE COVER. NO USER SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
REFER TO MANUAL FOR ENVIRONMENTAL CONDITIONS.
/ CSN75A12V3-G
RISK OF ELECTRICAL SHOCK. DO NOT
FCC CLASS B VERIFIED
Mustbe properly recycled or disposed.
Containssealed nonspillable lead acid battery.
E235457
I.T.E.POWERSUPPLY
LPS
Pb
12V 75W
100-120V~ 50-60Hz ; 2.0A
INPUT: OUTPUT:
Color Condition
SPECIFICATION
12V
12V RTN
SIG RTN
ON BATTERY
REPLACE BATTERY
BATTERY MISSING
LOW BATTERY
+ Voltage output
- Voltage output
Signal return
Low when operating from utility line.
Open when operating from battery.
Low when battery is charged.
Open when battery fails the Self Test.
Low when battery is present.
Open when battery is missing.
Low when battery is near full charge capacity.
Open when operating from a battery with < 20% capacity.
Signal Message
MODEL
Input Voltage Range
Input Frequency Range
Input Power Cord
AC Input
CSN75A12V3-G
North America (NEMA 5-15)
3-Prong Power Cord
90 - 132VAC
50 - 60 Hz
(L*W*D)
On Battery Output Voltage
Continuous Power Capability
Output Power Max
Efficiency (at 75% Max Load)
Battery Type
Numbers of Battery
Typical Recharge Time
Replaceable
Lightning / Surge Protection
Audible Indicator
LED Indicators
Auto-Charge
Communication Interface
Maximum Dimensions
Weight
Operating Temperature
Operating Humidity
Max Operating Elevation
Max Storage Elevation
Storage Temperature
Environment
Battery
DC Output
Physical
Surge Protection and Filtering
Warning Diagnostics
Management
12VDC (10.35 - 13.65VDC at 25°C)
75W
75W
20AH / 12V x 1
30cm x 28cm x 10.1cm
8.2Kg
Sealed, Maintenance Free Lead-Acid Battery
On Battery, Replace Battery, Battery Missing, Low Battery
-4°F - 113°F (-20°C - 45°C)
10,000 ft (3,048m)
Utility Failure, Low Battery
50,000 ft (15,240m)
-4°F - 113°F (-20°C - 45°C)
>80%
Around 20 hours
Yes
Yes
AC, Output, Battery
Yes
0 - 95% noncondensing within enclosure
COMMUNICATION SIGNALS
BUZZER ON / OFF SWITCH
The default position of the buzzer switch is OFF.
If you want to enable this function, there is a button
inside the hole, please insert a paper clip or small
pointed object into the hole and press the button.
In case of utility failure (on battery ), it will emit a
long beep.In case of low battery, it will emit a short
beep.
Utility Power Cord Inlet
Communication signals
COLD START
LOW BATTERY
BATTERY MISSING
REPLACE BATTERY
ON BATTERY
XBP
12V
SIG RTN
12V RTN
12V
+
-
LIMITED WARRANTY
CyberPower warrants to you, the Initial Purchaser, that the Product will be free from defects in material and workmanship for three years from the date of original purchase, subject to the terms of this Limited
Warranty. This Limited Warranty gives you specific rights, and you may have other rights, which vary from State to State or Province to Province.
Any Implied Warranty of Merchantability or for Fitness for a Particular Purpose, if applicable to the Product, is limited in duration to three years. This provision shall NOT create any Implied Warranty or
Merchantability or of Fitness for a Particular Purpose that would not otherwise apply to the Product. NOTE: Some States and Provinces do not allow limitations on how long an implied warranty lasts,
so the above limitation may not apply to you.
To be covered you must still be the owner of the Product at the time of the failure that results in the claim made under this Limited Warranty. Your sole and exclusive remedies are those provided by this
Limited Warranty. This exclusion of other express warranties applies to written and oral express warranties. CyberPower excludes any liability for personal injury. CyberPower excludes any liability for direct,
indirect, special, incidental, or consequential damages, whether for damage to or loss of property, loss of profits, business interruption, information or data. This exclusion applies even though damage or loss
is caused by negligence or other fault. NOTE: Some States or Provinces do not allow the exclusion or limitations of incidental or consequential damages, so the above limitation may not apply to you.
DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT OR OTHER HIGH RISK ACTIVITIES.
CyberPower does not sell the PRODUCT for use in high-risk activities. The PRODUCT is not designed or intended for use in hazardous environments requiring fail-safe performance, including the operation
of nuclear facilities, aircraft navigation or communication systems, air traffic control, weapons systems, life support or medical applications or for use in any circumstance in which the failure of the PRODUCT
could lead directly to death, personal injury, or severe physical or property damage, or that would affect operation or safety of any medical or life support device (collectively, "High Risk Activities").
CyberPower expressly disclaims any express or implied warranty of fitness for High Risk Activities. CyberPower does not authorize use of any PRODUCT in any High Risk activities.
ANY SUCH USE IS IMPROPER AND IS A MISUSE OF A CYBERPOWER PRODUCT.
The Limited Warranty is governed by the laws of the United States and the State of Minnesota, without reference to conflict of law principles. The application of the United Nations Convention of Contracts for
the International Sale of Goods is expressly excluded
FCC NOTICE:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with these instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: (1) Reorient or relocate the receiving antenna.
(2) Increase the separation between the equipment and receiver. (3) Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. (4) Consult the dealer or an
experienced radio/TV technician for help.
CAUTION: Shielded signal cables must be used with this device to ensure compliance with Class B FCC limits.
CAUTION: Any changes or modifications not expressly approved by CyberPower could void the authority granted by the FCC to operate this equipment.
For more information, please contact:
CyberPower Systems ( USA ), Inc. 4241 12th Avenue East, Suite 400, Shakopee, MN55379 Phone: (952)403-9500 Fax: (952)403-0009 www.cyberpowersystems.com
CyberPower Systems ( EUROPE ), Inc.. Flight Forum 3545, 5657DW Eindhoven, The Netherlands E-mail: [email protected] eu.cyberpowersystems.com
K01-7512001-00
The communication signals of this unit are isolated from the internal circuitry via open
collector opto-coupled transistors. The connection “SIG RTN” (Signal Return) is a common
return point for all communication signals. In the typical application, the attached equipment
digital ground connects to Signal Return, and pull-up resistors turn the open collector
signals into logic levels.
Alarm Silence

Other CyberPower UPS manuals

CyberPower BR700ELCD-UK User manual

CyberPower

CyberPower BR700ELCD-UK User manual

CyberPower ST425 User manual

CyberPower

CyberPower ST425 User manual

CyberPower 649532110001 User manual

CyberPower

CyberPower 649532110001 User manual

CyberPower OLS6KERT4UA User manual

CyberPower

CyberPower OLS6KERT4UA User manual

CyberPower 649532022069 User manual

CyberPower

CyberPower 649532022069 User manual

CyberPower UT650EG User manual

CyberPower

CyberPower UT650EG User manual

CyberPower UP1200 User manual

CyberPower

CyberPower UP1200 User manual

CyberPower OL10000RT3UTF User manual

CyberPower

CyberPower OL10000RT3UTF User manual

CyberPower BRG850 User manual

CyberPower

CyberPower BRG850 User manual

CyberPower STANDBY UPS Series User manual

CyberPower

CyberPower STANDBY UPS Series User manual

CyberPower ST425 User manual

CyberPower

CyberPower ST425 User manual

CyberPower UT1500E-FR/UPS User manual

CyberPower

CyberPower UT1500E-FR/UPS User manual

CyberPower 649532006878 User manual

CyberPower

CyberPower 649532006878 User manual

CyberPower Value1200EILCD User manual

CyberPower

CyberPower Value1200EILCD User manual

CyberPower CPS725SL User manual

CyberPower

CyberPower CPS725SL User manual

CyberPower CyberShield CS24U12V User manual

CyberPower

CyberPower CyberShield CS24U12V User manual

CyberPower CPS900AVR User manual

CyberPower

CyberPower CPS900AVR User manual

CyberPower 649532607006 User manual

CyberPower

CyberPower 649532607006 User manual

CyberPower CPS1000E User manual

CyberPower

CyberPower CPS1000E User manual

CyberPower 649532015061 User manual

CyberPower

CyberPower 649532015061 User manual

CyberPower Sinewave Series User manual

CyberPower

CyberPower Sinewave Series User manual

CyberPower CP825AVRLCD-G Series User manual

CyberPower

CyberPower CP825AVRLCD-G Series User manual

CyberPower ValuePro VP700ELCD User manual

CyberPower

CyberPower ValuePro VP700ELCD User manual

CyberPower OR500LCDRM1U User manual

CyberPower

CyberPower OR500LCDRM1U User manual

Popular UPS manuals by other brands

Minuteman MCP-E user manual

Minuteman

Minuteman MCP-E user manual

Datalogic 94ACC0164 instructions

Datalogic

Datalogic 94ACC0164 instructions

Omron Powli BY35S instruction manual

Omron

Omron Powli BY35S instruction manual

Phoenix Contact TRIO-UPS-2G/1AC/24DC/10 manual

Phoenix Contact

Phoenix Contact TRIO-UPS-2G/1AC/24DC/10 manual

Tescom LEO LCD 650 user manual

Tescom

Tescom LEO LCD 650 user manual

EFOY EFOY Pro 600 Operation and installation manual

EFOY

EFOY EFOY Pro 600 Operation and installation manual

Eaton Powerware 9125 installation guide

Eaton

Eaton Powerware 9125 installation guide

NXT Power INTEGRITY MAX L/T UPS Series manual

NXT Power

NXT Power INTEGRITY MAX L/T UPS Series manual

Keatec Energy C Series user guide

Keatec Energy

Keatec Energy C Series user guide

Battery Backup Power 15KL manual

Battery Backup Power

Battery Backup Power 15KL manual

AEG 80 / 120 kVA operating instructions

AEG

AEG 80 / 120 kVA operating instructions

Borri INGENIO COMPACT operating manual

Borri

Borri INGENIO COMPACT operating manual

Eaton Eaton 5PX Advanced user's guide

Eaton

Eaton Eaton 5PX Advanced user's guide

OPTI-UPS DS-D33 user guide

OPTI-UPS

OPTI-UPS DS-D33 user guide

lapara 1K user manual

lapara

lapara 1K user manual

INFOSEC X4 SINUSRT user guide

INFOSEC

INFOSEC X4 SINUSRT user guide

Vertiv Liebert NXL installation manual

Vertiv

Vertiv Liebert NXL installation manual

Gamatronic POWER PLUS Technical guide

Gamatronic

Gamatronic POWER PLUS Technical guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.