Dahua DEE1010B User manual

Access and Control Extension Module
User’s Manual
Version 1.0.0

i
Welcome
Thank you for purchasing our product!
This user’s manual is designed to be a reference tool for your system.
Please keep this user’s manual well for future reference!
Please read the following safeguard and warnings carefully before you use this series product!
Important Safeguards and Warnings
All installation and operation here should conform to your local electrical safety codes.
We assume no liability or responsibility for all the fires or electrical shock caused by improper
handling or installation.
Do not apply power to the device before completing installation.
UPS is recommended if you want to use the device even in power failure.
Always follow the instruction guide the manufacturer recommended.
Be sure to use all the accessories recommended by manufacturer.
We are not liable for any problems caused by unauthorized modifications or attempted repair.

ii
Table of Contents
1.
General Introduction ..................................................................................................................1
1.1
Overview........................................................................................................................1
1.2
Typical Connection.......................................................................................................1
2.
Installation....................................................................................................................................2
3.
FAQ ..............................................................................................................................................3
4.
Specifications..............................................................................................................................4

1
1. General Introduction
1.1 Overview
The access and control extension module is a door extension module controller for 86mm×86mm
power box. The extension module can work independently with the access control, video door
phone and management platform. It can easily realize A&C extension function. The module
communicates with the upper-level device via RS485 BUS to realize A&C function and support
swipe card function with the card reader. It has one-channel door sensor signal input, one-
channel lock/unlock input and one-channel door sensor control output and etc. The door lock
supports NO/NC.
Access and control extension module can work with the management platform to issue card,
delete card and open door remotely. The module can upload the swipe card information, door
lock/unlock information, alarm information to the management center to realize the realtime door
surveillance. Besides, the management center can set the A&C parameters and set customized
swipe card period and time sync. After grant the card rights, it can swipe the card or use the
button to open the door without the main controller.
1.2 Typical Connection
Please refer to the following figure for typical connection information. See Figure 1.
Figure 1

2
2. Installation
Please refer to the following figure for installation information. See Figure 2.
Figure 2
Please refer to the following sheet for detailed information
SN Name Function
1 +12V Power
2 GND Power GND
3 485A Host 485A
4 485B Host 485B
5 POWER Power indicator light
6 RUN Running indicator light
7 UNLOCK Unlock indicator light
8 NC Lock normal close
9 NO Lock normal open
10 COM Lock COM
11 BUTTON Lock/unlock button
12 BACK Lock sensor feedback
13 GND Ground
14 485B Card reader 485B
15 485A Card reader 485A

3
3. FAQ
I swipe the card but can not open the door.
Please contact the management center, make sure the card has the corresponding right, or
it is still in the valid period or it can not be used in currenr period.
The magcard is damaged.
Check the card reader connection. Make sure the card and the reader can work properly.
The lock or the device is damaged.
The device and the management center can not communicate.
Check 485 communication cable connection.
Click the lock/unlock button can not open the door.
Check the lock/unlock button and the device connection.
After open the door, the lock remains open for a long time.
Check the door is close or not.
The door sensor connection is OK or not. If there is no door sensor, please contact the
management center to make sure there is door sensor.
I still have questions here.
Please contact you retailer or serivic enginner for help.

4
4. Specifications
Model Module
A&C
Lock NO Support
Lock NC Support
Lock/Unlock
Button Support
Door Status
Detection Support
Operation Mode
Input Swipe card to input(work with the card reader)and lock/unlock
button
IC
Card
Supported Card
Amount
Max 5000 cards
Add/
Delete C
ard
Support
Realtime Clock
Clock Time
Sync Support
RTC Protection
after Power
Outage
Support
Uploaded Information
Upload Card No.Support
Upload Door
Open
Information Support
Upload Alarm Support
Others
Power
Supplying DC12V±10%
Power
Consumptions Standby≤0.5W;Work≤1W
Working
Environment -10℃~+60℃
10~95%RH
Dimensions 58mm*51mm*24.5mm(L*W*H)
Weight 0.56kg
Note
•This manual is for reference only. Slight difference may be found in the user
interface.
•All the designs and software here are subject to change without prior written
notice.
•All trademarks and registered trademarks are the properties of their respective
owners.
•If there is any uncertainty or controversy, please refer to the final explanation of us.

5
•Please visit our website or contact your local service engineer for more
information.
Table of contents