
Project Name
Date Type
Catalog Number
AGENT/DISTRIBUTOR NAME-LOGO
FIELD-INSTALLABLE MOUNTING AND ACCESSORY OPTIONS
Mounting/Accessory Options
NOTE: If you press button, the remote led indicators will show the latest parameters which
were sent.
DDIISSPP
-1- - 2-
BRIGHTNESS
HOLD TIME
DAYLIGHT
SENSOR
STAND-BY DIM
STAND-BY TIME
High end trim turning function(To
Set the output level of connected
lighting during occupancy)
To repre sents t he t ime tha t th e
Sens or w ill k ee p the lig ht a t low d im
leve l af ter t he H OLD TIME el ap sed.
To represents various thresholds of
natural light level for the Sensor .
The daylight sensor stops working,
and all motion detected could turn on
the li gh ting fi xture , no m atter h ow
bright the natural light is.
LED DESCRIPTION DESCRIPTION
The time that the Sensor will turn
off(if you choose stand-by level is
0) or dim the light to a low level
after the area is vacated
SENSITIVITY
To set the occupancy sensing
sensitivity of the Sensor
LED
To set the o ut put l ev el of con ne cted
lighting during vacancy. The sensor
will regulate the lighting output at
the se t le vel . Se tting t he S TAN D-BY
DIM le ve l at 0 me an s light f ul l off
duringvacancy.
To select the current surrounding lux
value as the daylight threshold. This
feat ur e enabl es the fi xt ure to fu nc tion
well in any real application
circumstances.
LED INDICATORS
SPECIFICATIONS
Power supply
Carrying case
Upload range
Op. temperature
Dimensions
2 x AAA 1.5V battery, Alkaline preferred
RC-100 in carrying case
Up to 15 m (50 ft.)
0°C~50°C (32°F~122°F)
123 x 70 x 20.3 mm (4.84" x 2.76" x 0.8")
Sensor Remote Programmer
OPERATION INSTRUCTIONS
RC-100
Remove the batteries from compartment if the remote will not be used in 30 days.
WARNING
OVERVIEW
The Wireless IR Configuration Tool is a handheld tool for remote configuration of remote control
IR-enabled fixture integrated sensors. The tool enables device to modify via pushbutton without
ladders or tools, and stores up to four sensor parameter modes to speed configuration of multiple
sensors.
The uses bidirectional IR communication to send and receive sensor settings at remote control
mounting height up to 50 feet. The device can display previously established sensor parameters,
copy parameters and send new parameters or store parameter profiles. For projects where identical
settings may be desired across a large number of areas or spaces, this capability provides a
streamlined method of configuration. Settings can be copied throughout a site, or in different sites.
with carrying case
REMOTE
500300100
503010
MOD E4MOD E3MOD E2MOD E1
DAYLIGH T
SENSOR
BUTTON OPERATION
Pres s bu tto n, a ll sett in gs go
back t o se tting s of dip Sw it ch in
sensor.
OONN//
OOFFFF
Press button, upload the
current parameters to sensor(s),
the led light which the sensor
connects will on/off as confirm.
SSEENNDD
OOKK
Press button, the sensor starts to
function and all settings remain the same
as the latest status before the light is
switched on/off.
AAUUTTOO
Enter in the setting condition, the
parameter leds of remote control will
flash to be selected. and Navigate to
UP and Down for choose selected
parameters in LED indicators.
The button is for testing purp os e
sensitivity only. after you choose sensitivity
thresholds , th en y ou p re ss b ut to n,
The sensor goe s to tes t mo de (h ol d ti me i s
only 2s) automatically ,meanwhile the
stand-by period and daylight sensor are
disabled. Pr es s bu tt on t o qu it f ro m
this mode.
TTEESSTT
2s
BUTTON DESCRIPTION BUTTON DESCRIPTION
RREESSEETT
DDIISSPP
Display the current/lastest setting
parameters in LED indicators(the
LED indicators will on for showing
the setting parameters).
4 Scene modes with preset
parameters which are available to
be changed and saved in modes.
MMOODDEE11MMOODDEE22
MMOODDEE33MMOODDEE44
Navigate to LEFT and RIGHT for
choose selected parameters in
LED indicators.
SETTING
The SETTING Content contains all available settings and parameters for remote sensors. It
allows you to change the available control, parameters, and operation of the sensor from
factory default or current parameters.
Change multiple settings of sensor(s)
1.Press button, the remote control leds will show the latest parameters you set.
Confirm the selected parameters
selected parameters in remote
control.
Open and close smart daylight Sensor.
Press or Enter in the setting
condition, the parameter leds of remote
control will flash to be selected, Press
for open or close smart daylight
Sensor.
DDIISSPP
SSEENNDD
TTEESSTT
2s
TTEESSTT
2s
AAUUTTOO
NOTE: the setting works key step is by Push or , enter in the setting condition.
NOTE: the led light which the sensor connects will on/off after getting the new parameter as confirm.
RREESSEETT
Press the button, the light goes
to permanent on or permanent off
mode, and the sensor is disabled.
(MUST press button to quit this
mode for Setting.
AAUUTTOO
OONN//
OOFFFF
AAUUTTOO
OONN//
OOFFFF
AAUUTTOO
NOTE: if you push button before, you must push button to unlock the sensor.
2.Press or enter in the setting condition, the parameter leds of remote control will flash to be
selected, navigate to the desired setting by pressing to select the new parameters.
3.Press ok to confirm all setting and saving.
4.Aim at the target sensor and press to upload the new parameter, the led light which the sensor
connects will on/off as confirm.
Albeo®ARC Series
MOUNTING/ACCESSORY OPTIONS IMAGE ORDER SKU# DIMENSIONS/NOTES
ARC Emergency Battery Back-Up Kit
(120-277V)
120-277V
Safety Tether (optional)
100W
150W
200-240W
Cable length:
Wire Guard (optional)
100W
150W
200-240W
100W:
150W:
200-240W:
Polycarbonate Refractor (optional)
100W
150W
200-240W
100W:
150W
200-240W:
Polycarbonate Drop Lens (optional)
100-150W
200-240W
Drop lens adds:
100W:
150W:
200-240W:
Aluminum Reector (optional)
100W
150W
200-240W
100W:
150W:
200-240W:
Wall Mount Bracket (optional) (Not
Yet Available)
Coming Soon Total Height of assembly from top of bracket to
bottom of xture:
100W:
150W:
200-240W:
12V Tri-level occupancy and/or light
sensor (optional)
Sensor
Remote
Notes:
maintains IP65 rating
2.
Sensor requires remote if programming is desired