Daintree GE Tetra Stick User manual

1
RETROFIT SIGN CONVERSION LED KIT FOR USE ONLY IN
ACCORDANCE WITH KIT INSTRUCTIONS.
KIT IS COMPLETE ONLY WHEN ALL PARTS REQUIRED BY
THE INSTRUCTIONS ARE PRESENT.
TROUSSE DE CONVERSION À DEL POUR LA
MODERNISATION DES ENSEIGNES
À UTILISER CONFORMÉMENT AU GUIDE D’INSTALLATION.
Prepare Electrical Wiring
Electrical Requirements
• Limited to use in dry and damp locations.
• The grounding and bonding of the LED Driver shall be
done in accordance with National Electric Code (NEC)
Article 600.
• Follow all National Electric Codes (NEC) and local codes.
• These products are only suitable for connection to a circuit
from a Class 2 power source.
• These products have not been evaluated for use when connected
to a power source that does not comply with Class 2 voltage and
energy limited supplies.
Save These Instructions
Use only in the manner intended by the manufacturer. If
you have any questions, contact the manufacturer.
WARNING/AVERTISSEMENT
RISK OF ELECTRIC SHOCK
∙Turn power o before inspection, installation or
removal.
∙Properly ground GE power supply enclosure.
RISK OF FIRE
∙Use only UL approved wire for input/output
connections. Minimum size 18 AWG (0.82mm2)
∙Follow all NEC and local codes.
∙Not to be submerged or used in a marine
environment.
RISK OF FIRE OR ELECTRIC SHOCK
∙LED Retrot Kit installation requires knowledge
of sign electrical systems. If not qualied, do not
attempt installation. Contact a qualied electrician.
∙Install this kit only in host signs that have been
identied in the installation instructions and where the
input rating of the retrot kit does not exceed the input
rating of the sign.
∙Installation of this LED retrot kit may involve drilling
or punching of holes into the structure of the sign.
Check for enclosed wiring and components to avoid
damage to wiring and electrical parts.
∙Do not make or alter any open holes in an enclosure
of wiring or electrical components during kit
installation.
RISQUES DE DÉCHARGES ÉLECTRIQUES
∙Coupez l’alimentation avant l’inspection, l’installation ou le déplacement.
∙Assurez-vous de correctement mettre à terre l’alimentation électrique GE.
RISQUES D’INCENDIE
∙N’utilisez que des ls approuvés par UL pour les entrées/sorties de connexion.
Taille minimum 18 AWG (0.82mm2)
∙Respectez tous les codes NEC et codes locaux.
∙Ne pas submerger ou installer dans un environnement marin.
RISQUE D’INCENDIE OU DE CHOC ÉLECTRIQUE
∙L’installation de l’équipement de remplacement DEL exige Ia connaissance
des systèmes électriques pour enseignes. Si non qualié, ne tentez pas
d’installation. Veuillez contacter un électricien qualié.
∙Risque d’incendie ou de choc Électrique. Installez cet ensemble seulement dans
des enseignes hôtes qui ont été identiés dans les instructions d’installation et
dont la capacité d’entrée de l’ensemble ne dépasse pas la capacité d’entrée de
l’enseigne.
∙L’installation de cet équipement de remplacement DEL peut impliquer le
perçage ou le poinçonnage de trous dans la structure du panneau Vériez le
câblage et les composants inclus pour éviter d’endommager le câblage et les
composants électriques.
∙Ne pas faire ou modier les trous ouverts dans une enceinte de câblage
ou de composants électriques pendant l’installation de cet équipement de
remplacement DEL.
Tetra®Stick
Fluorescent Box Sign Retrot
LED Lighting System
Installation Guide
2424
Volt
(GETSAABBCCC71D1)*
BEFORE YOU BEGIN
Read these instructions completely and carefully.
*key
AA PM = PowerMax or PH = PowerMax High Output
BB SS = Single Sided or DS = Double Sided
CCC 018=18’’; 024=24’’; 030=30’’; 036=36’’; 042=42’’; 048=48’’; 060=60’’; 064=64’’; 072=72’’; 084=84’’; 096=96’’; 108=108’’; 117=117’’;
120=120’’
D A=3’ Whip Length or B=6’ Whip Length

5TCMeasure Point
2
Installation
Turn o power and remove panel
from uorescent box sign.
1Read the product labels to determine
Tetra Stick length required to span
width of sign based on table in the
Specications section (pages 4-5).
3
Old Fluorescent
tube
Remove old
components F48T12HO
or F48T8HO
Remove old uorescent tubes, ballast
and wiring. DO NOT remove existing
uorescent lamp holders. Inspect
existing sockets and replace as needed.
De-energize the lamp holders.
NOTE:
Follow all federal and local
regulations when disposing of neon
tubing, uorescent tubes, transformers
and ballasts.
2
Prior to installation, survey the site for information regarding power and accessibility inside and outside the building. Ensure
that the branch circuit supplying the existing transformer or ballast will be within the voltage ratings of the new LED power
supply, and have a current rating not exceeding 20A, or that permitted by applicable local, state, or country electrical codes
(whichever is less).
If removal of the existing lighting equipment (see Step 2) eliminates the disconnect switch, as required by applicable local,
state, or country electrical codes; a new disconnect switch must be installed.
If required, the disconnect switch shall be installed by qualied personnel, in accordance with applicable local, state, and
country electrical codes.
Repair and seal any unused openings in the electrical enclosure. Openings greater than 12.7-mm (1/2-in) diameter require a
metal patch secured by screws or rivets and caulked with non-hardening caulk. Smaller openings may be sealed with non-
hardening caulk.
GETSAABBCCC71-6-1
Tetra Stick
Components
1
2
3
4
23
1
45
6
UL certied 18 AWG (0.82 mm2) supply wire
UL certied 22-14 AWG (0.33-2.08 mm2) wire connectors or
22-18 AWG (0.33-0.82 mm2) inline/IDC connectors
93020091 LFL-LED Sockets LineFit Light Sockets (optional)
Tetra®24 Volt Power Supply
GE Tetra® Stick
Electrical grade RTV silicone. Examples below:
• Momentive RTV 6700 Series Silicone Rubber Adhesive Sealant
• Momentive White Blanc RTV 162 Silicone Rubber Adhesive
Sealant-Electrical Grade
• Dow Corning 3140 - Non-Corrosive Flowable (clear)
• Dow Corning 3145 - Non-Corrosive Nonowable (clear or
gray)
• Dow Corning RTV 748 Non-Corrosive Sealant-White
6
Push Tetra Stick into existing
uorescent lamp holders.
5Continue installing Tetra Stick xtures.
NOTE: For horizontal installations
greater than 6ft in length, the Tetra
Stick(s) should be centrally supported.
6
Orient Tetra Stick so LEDs are facing
front of sign.
4
See Note about support
LEDs face
front of sign
Existing socket should
be push-in double
contact lamp holder

+
+
3
1Connect the red wire (+) of the Tetra Stick to the red wire (+) of the power supply. Connect the black wire (-) of the Tetra Stick
to the black or blue wire (-) of the power supply. Seal all connections that could be exposed to water with electrical grade
RTV silicone
Electrical Connections
Single Tetra Stick Installation
Power Supply
Add up total number of Tetra Sticks to determine the
appropriate number of 24VDC Class 2 Tetra LED drivers
to use based on the Specications Charts for Tetra
Stick chosen (see pages 4-5).
1
Mutiple Tetra Stick Installation
Connect the red wire (+) of the Tetra Stick to the red
wire (+) of the power supply. Connect the black wire (-)
of the Tetra Stick to the black or blue wire (-) of the
power supply.
2
AC line GEPS24-180
3Connect Tetra Stick using twist-on wire connectors or in-line (IDC) connectors. Join black wires together and red wires
together. Seal all connections that could be exposed to water with electrical grade RTV silicone.
NOTE: Make sure not to exceed LED driver power limits (see Step 1). Drawing above is for reference only; your lighting
layout may dier.
NOTE: All drivers except GEPS24-180U and GEPS24-300U must be enclosed or provided with a GEPSJB60 LED driver
extended enclosure.
NOTE: Refer to Power Supply Installation Guide for AC driver installation.
Power supply To Tetra Sticks
Red (+)
Red (+) Black (-)
Black or blue (-)
Power supply To Tetra Sticks
Red (+)
Red (+) Black (-)
Black or blue (-)

4
T-12
Length
(in)
Actual
Length
(in)
Watts
per Stick
Sticks per
80W
Power
Supply
Sticks per
100W
Power
Supply
Sticks per
180W
Power Supply
Total (per
Bank)
Sticks per
300W
Power
Supply
Total (per
Bank)
Part Number
(A-3 foot whip / B-6 foot whip)
18 15.91 1.7 38 47 86(43) 141(47) GETSPMSS1871A1 / GETSPMSS1871B1
24 21.91 2.5 26 32 58(29) 96(32) GETSPMSS2471A1 / GETSPMSS2471B1
30 27.91 2.5 26 32 58(29) 96(32) GETSPMSS3071A1 / GETSPMSS3071B1
36 33.91 3.4 19 24 42(21) 72(24) GETSPMSS3671A1 / GETSPMSS3671B1
42 39.91 4.2 15 19 34(17) 57(19) GETSPMSS4271A1 / GETSPMSS4271B1
48 45.91 5.0 13 16 30(15) 48(16) GETSPMSS4871A1 / GETSPMSS4871B1
60 57.91 5.9 11 14 24(12) 42(14) GETSPMSS6071A1 / GETSPMSS6071B1
64 61.91 6.7 10 12 22(11) 36(12) GETSPMSS6471A1 / GETSPMSS6471B1
72 69.91 7.6 8 11 20(10) 33(11) GETSPMSS7271A1 / GETSPMSS7271B1
84 81.91 8.4 8 10 18(9) 30(10) GETSPMSS8471A1 / GETSPMSS8471B1
96 93.91 10.1 6 8 14(7) 24(8) GETSPMSS9671A1 / GETSPMSS9671B1
108 105.91 10.9 6 7 14(7) 21(7) GETSPMSS10871A1 / GETSPMSS10871B1
117 114.91 11.8 5 7 12(6) 21(7) GETSPMSS11771A1 / GETSPMSS11771B1
120 117.91 12.6 5 6 12(6) 18(6) GETSPMSS12071A1 / GETSPMSS12071B1
T-12
Length
(in)
Actual
Length
(in)
Watts
per
Stick
Sticks per
80W
Power
Supply
Sticks per
100W
Power
Supply
Sticks per
180W Power
Supply
Total (per
Bank)
Sticks per
300W
Power
Supply Total
(per Bank)
Part Number
(A-3 foot whip / B-6 foot whip)
18 15.91 3.40 19 24 42(21) 72(24) GETSPMDS1871A1 / GETSPMDS1871B1
24 21.91 5.00 13 16 30(15) 48(16) GETSPMDS2471A1 / GETSPMDS2471B1
30 27.91 5.00 13 16 30(15) 48(16) GETSPMDS3071A1 / GETSPMDS3071B1
36 33.91 6.80 9 12 22(11) 36(12) GETSPMDS3671A1 / GETSPMDS3671B1
42 39.91 8.40 8 10 18(9) 30(10) GETSPMDS4271A1 / GETSPMDS4271B1
48 45.91 10.00 6 8 14(7) 24(8) GETSPMDS4871A1 / GETSPMDS4871B1
60 57.91 11.80 5 7 12(6) 21(7) GETSPMDS6071A1 / GETSPMDS6071B1
64 61.91 13.40 5 6 10(5) 18(6) GETSPMDS6471A1 / GETSPMDS6471B1
72 69.91 15.20 4 5 10(5) 15(5) GETSPMDS7271A1 / GETSPMDS7271B1
84 81.91 16.80 4 5 8(4) 15(5) GETSPMDS8471A1 / GETSPMDS8471B1
96 93.91 20.20 3 4 6(3) 12(4) GETSPMDS9671A1 / GETSPMDS9671B1
108 105.91 21.80 3 3 6(3) 9(3) GETSPMDS10871A1 / GETSPMDS10871B1
117 114.91 23.60 2 3 6(3) 9(3) GETSPMDS11771A1 / GETSPMDS11771B1
120 117.91 25.20 2 3 6(3) 9(3) GETSPMDS12071A1 / GETSPMDS12071B1
Specications – Single Sided PowerMAX
Specications – Double Sided PowerMAX

5
T-12
Length
(in)
Actual
Length
(in)
Watts
per
Stick
Sticks per
80W
Power
Supply
Sticks per
100W
Power
Supply
Sticks per
180W
Power
Supply
Total (per
Bank)
Sticks per
300W
Power
Supply
Total (per
Bank)
Part Number
(A-3 foot whip / B-6 foot whip)
18 15.91 2.40 26 33 58(29) 99(33) GETSPHSS1871A1 / GETSPHSS1871B1
24 21.91 3.60 17 22 40(20) 66(22) GETSPHSS2471A1 / GETSPHSS2471B1
30 27.91 3.60 17 22 40(20) 66(22) GETSPHSS3071A1 / GETSPHSS3071B1
36 33.91 4.80 13 16 30(15) 48(16) GETSPHSS3671A1 / GETSPHSS3671B1
42 39.91 6.00 10 13 24(12) 39(13) GETSPHSS4271A1 / GETSPHSS4271B1
48 45.91 7.20 9 11 20(10) 33(11) GETSPHSS4871A1 / GETSPHSS4871B1
60 57.91 8.40 7 9 18(8) 27(9) GETSPHSS6071A1 / GETSPHSS6071B1
64 61.91 9.60 7 8 14(7) 24(8) GETSPHSS6471A1 / GETSPHSS6471B1
72 69.91 10.80 6 7 14(7) 21(7) GETSPHSS7271A1 / GETSPHSS7271B1
84 81.91 12.00 5 7 12(6) 21(7) GETSPHSS8471A1 / GETSPHSS8471B1
96 93.91 14.40 4 6 10(5) 18(6) GETSPHSS9671A1 / GETSPHSS9671B1
108 105.91 15.60 4 5 10(5) 15(5) GETSPHSS10871A1 / GETSPHSS10871B1
117 114.91 16.80 4 5 8(4) 15(5) GETSPHSS11771A1 / GETSPHSS11771B1
120 117.91 18.00 3 4 8(4) 12(4) GETSPHSS12071A1 / GETSPHSS12071B1
T-12
Length
(in)
Actual
Length
(in)
Watts
per
Stick
Sticks per
80W
Power
Supply
Sticks per
100W
Power
Supply
Sticks per
180W
Power
Supply
Total (per
Bank)
Sticks per
300W
Power
Supply
Total (per
Bank)
Part Number
(A-3 foot whip / B-6 foot whip)
18 15.91 4.8 13 16 30(15) 48(16) GETSPHDS1871A1 / GETSPHDS1871B1
24 21.91 7.2 9 11 20(10) 33(11) GETSPHDS2471A1 / GETSPHDS2471B1
30 27.91 7.2 9 11 20(10) 33(11) GETSPHDS3071A1 / GETSPHDS3071B1
36 33.91 9.6 7 8 14(7) 24(8) GETSPHDS3671A1 / GETSPHDS3671B1
42 39.91 12.0 5 7 12(6) 21(7) GETSPHDS4271A1 / GETSPHDS4271B1
48 45.91 14.4 4 5 10(5) 15(5) GETSPHDS4871A1 / GETSPHDS4871B1
60 57.91 16.8 4 5 8(4) 15(5) GETSPHDS6071A1 / GETSPHDS6071B1
64 61.91 19.2 3 4 8(4) 12(4) GETSPHDS6471A1 / GETSPHDS6471B1
72 69.91 21.6 3 4 6(3) 12(4) GETSPHDS7271A1 / GETSPHDS7271B1
84 81.91 24.0 2 3 6(3) 9(3) GETSPHDS8471A1 / GETSPHDS8471B1
96 93.91 28.8 2 3 4(2) 9(3) GETSPHDS9671A1 / GETSPHDS9671B1
108 105.91 31.2 2 2 4(2) 6(2) GETSPHDS10871A1 / GETSPHDS10871B1
117 114.91 33.6 2 2 4(2) 6(2) GETSPHDS11771A1 / GETSPHDS11771B1
120 117.91 36.0 1 2 4(2) 6(2) GETSPHDS12071A1 / GETSPHDS12071B1
Specications – Single Sided PowerMAX HO
Specications – Double Sided PowerMAX HO

GE and the GE Monogram are trademarks of the General Electric Company and are used under license. Information provided is subject to change
without notice. All values are design or typical values when measured under laboratory conditions, and GE makes no warranty or guarantee,
express or implied, that such performance will be obtained under end-use conditions. © 2019 GE Current, a Daintree company.
www.LED.com SIGN220 (Rev 12/17/19) A-1001149
Wattage Power Supply Long Description
80W
GEPS24D-80U
Power Supply (24VDC / 96W), Input Voltage: 108-305VAC;
Damp Rated; Self-Contained, Remote or Raceway;
1 Output Bank; Class 2
GEPS24W-80
Power Supply (24VDC/180W), Input Voltage: 90-305VAC;
Damp Rated; Self-Contained, Remote or Raceway;
2 Output Banks of 90W each; Class 2
100W
GEPS24-100U-GL
GEPS24-100U-NA
GEPS24-100U-GLX
Power Supply (24VDC / 96W), Input Voltage: 108-305VAC;
Damp Rated; Self-Contained, Remote or Raceway;
1 Output Bank; Class 2
180W GEPS24-180U Power Supply (24VDC/96W), Input Voltage: 108-305VAC;
Damp Rated; 1 Output Bank; Class 2
300W GEPS24-300U-GL
0-10V Dimming Power Supply (24VDC/80W), Input Voltage: 90-305VAC;
Damp Rated; Self-Contained, Remote or Raceway;
1 Output Bank; Class 2
Power Supply Specications
Troubleshooting
This product is intended solely for the use of non-residential signage lighting and is not intended for use in any other applications.
Conforms to the following standards:
III
Symptom
Solution
Row of xtures does not light
• Check wire connections to power supply to ensure red stripe-to-red and white-to-black
connections.
• Check row-to-row polarity connections.
Sign does not light
• Check input and output voltage and check power supply input/output connections.
• Check polarity connections.
Individual xture does not light
• Remove xture and replace with another working xture.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual,
may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference
in which case the user will be required to correct the interference at his own expense.
This Class [A] RFLD complies with the Canadian standard ICES-005. Ce DEFR de la classe [A] est conforme à la NMB-005 du Canada.
This manual suits for next models
56
Table of contents
Other Daintree Work Light manuals
Popular Work Light manuals by other brands

REV Ritter
REV Ritter ZZ-812-SMD Assembly and operating instructions

Oregon Scientific
Oregon Scientific TH511 quick start guide

Kobalt
Kobalt WL 2040-06 Operator's manual

Concept LED Lights
Concept LED Lights V-PIX Vision Bar user manual

Makita
Makita DML805 instruction manual

DeWalt
DeWalt DCL074 instruction manual