DAN DRYER 3050 Manual

Version Document Lang. Page
16.06.2021 3050-3056 BJÖRK touch-free dispenser, soap / disinfectant
Maintenance and service manual
ENG 1
of 12
DAN DRYER A/S • Alsikevej 8 • DK-8920 Randers NV • +45 86 41 57 11 • www.dandryer.com • info@dandryer.dk
3050-3056 BJÖRK touch-free dispenser, liquid soap / disinfectant
Maintenance and service manual
Version: Description of changes: Page(s):
Version history

Version Document Lang. Page
16.06.2021 3050-3056 BJÖRK touch-free dispenser, soap / disinfectant
Maintenance and service manual
ENG 2
of 12
DAN DRYER A/S • Alsikevej 8 • DK-8920 Randers NV • +45 86 41 57 11 • www.dandryer.com • info@dandryer.dk
Preface 2
General 2
Intended product use 2
The supplier’s product liability 2
Safety and warnings 2
Installation and connection 3
External power supply (optional) 6
Liquid filling 7
Battery exchange 9
Regular maintenance 10
Trouble shooting 10
Technical specifications 11
Dimensions 11
Spare parts 12
Table of contents:
Preface
Thank you for purchasing your equipment from
DAN DRYER A/S and congratulations on your
new soap/disinfectant dispenser. If you use and
maintain your dispenser according to our manu-
al, it will work to your satisfaction for many years.
General
The dispenser must only be installed and used
in accordance with these instructions and safety
precautions. All service staff who work with
installation, servicing and repair of the dispenser
must have read and understood this manual. If
you have questions concerning the use or main-
tenance of your dispenser, you are welcome to
contact us.
Intended product use
The dispenser is designed for installation in indo-
or public or private restrooms and may only be
used for liquid soap/disinfectant.
The supplier’s product liability
DAN DRYER A/S accepts no responsibility if the
dispenser is installed, used, modified or compo-
sed otherwise than specified in this manual.
Warning!
If the dispenser is not installed and connected
properly it can be dangerous to use due to the
risk of electric shock. Always follow the installa-
tion instructions in this manual.
All service staff who work with servicing and
repairing of the dispenser must have read and
understood this manual.
Warning!
During cleaning, inspection, service etc. the
dispenser must always be disconnected from
the main power supply.
Safety precautions:
Maintenance work requiring dismantling of the
dispenser must only be carried out by staff with
proper training.
Safety precautions:
Check before use that:
• the dispenser is securely attached to the wall.
• the dispenser is properly cleaned.
• the dispenser is not damaged or otherwise in
disorder.

Version Document Lang. Page
16.06.2021 3050-3056 BJÖRK touch-free dispenser, soap / disinfectant
Maintenance and service manual
ENG 3
of 12
DAN DRYER A/S • Alsikevej 8 • DK-8920 Randers NV • +45 86 41 57 11 • www.dandryer.com • info@dandryer.dk
Installation and connection:
1. Open the front cover
using the supplied
square key.
2. Open the flap on the front of the pump hou-
sing by gently lifting it approximately 1 cm
and turn it anticlockwise.
4. Mark the holes
on the wall at the
chosen location by
using the enclosed
mounting template.
3. Remove the liquid container by gently pul-
ling it out of the pump housing.
To prevent accidental activation, the dispen-
ser must be placed at least 200 mm above
the tabletop (with normal reflection).
If the worktop is made of stainless steel
or other reflective material the minimum
distance is 300 mm.
!!"
# !"$%&'(')($!!"
('(%%!* '! +'(
,!%-.!!$ !$!
*%*/01/2
!34*546/%-
78949:;::)))<'
:;94
;
66
:6
-=,7=,7#.!'2'
=#&/7%7#!'')!(!!(2''!'
>=?@7=,#!'AB'(2'A!B'(!
=#&/7%7=C!D'E'2'E'..'(!
5. Mount dispenser on
the wall using the
three screw holes. Al-
ways use screw types
and plugs suitable for
your wall type.
6. Remove the cap
and fill the contai-
ner with appropia-
te liquid. Refit the
cap and wipe any
spilled soap.

Version Document Lang. Page
16.06.2021 3050-3056 BJÖRK touch-free dispenser, soap / disinfectant
Maintenance and service manual
ENG 4
of 12
DAN DRYER A/S • Alsikevej 8 • DK-8920 Randers NV • +45 86 41 57 11 • www.dandryer.com • info@dandryer.dk
7. Mount the liquid
container by
gently pushing it
into the groove
on the pump
housing.
8. Pull the silicone tube downwards and place the
outlet nozzle in the slot. Make sure that the collar
is located under the pump housing.
If the outlet nozzle
is placed or instal-
led incorrectly, the
pump will not func-
tion or its function
will be decreased.
Make sure that the
collar is located under
the pump housing.
9. Close the flap on the front of the pump
housing by turning clockwise and lifting it
approximately 1 cm so the two pins fall into
the guide holes.
11. Open the door to the battery box.
(If you have chosen to use external power
supply, skip to page 6).
10. Remove the
protective
plastic plug.
Installation and connection (continued):

Version Document Lang. Page
16.06.2021 3050-3056 BJÖRK touch-free dispenser, soap / disinfectant
Maintenance and service manual
ENG 5
of 12
DAN DRYER A/S • Alsikevej 8 • DK-8920 Randers NV • +45 86 41 57 11 • www.dandryer.com • info@dandryer.dk
Installation and connection (continued):
12. Carefully remove the battery box from the pump
housing. Be careful not to pull the wires. Mount
four AA batteries as shown. Be aware that they
must be properly oriented with polarity as indica-
ted inside the battery box.
13. Put the battery box back into the pump housing
and gently close the door to the battery box.
14. Close the front cover by pushing it against
the wall until your hear a ”click”.
The dispenser is now ready for use.
This manual suits for next models
1
Table of contents
Other DAN DRYER Dispenser manuals
Popular Dispenser manuals by other brands

BOWMAN
BOWMAN CL003-0111 manual

SIKA
SIKA Power Cure operating instructions

Silver King
Silver King Majestic SK12MAJ Technical manual and replacement parts list

Franke
Franke F3Dn Twin Service manual

HURAKAN
HURAKAN HKN-MT1 manual

STIEBEL ELTRON
STIEBEL ELTRON UltraHot Plus Operation and installation instructions