D&H Lifelabs AquaSolvo Eco AAE-5005 Series User manual

AquaSolvoTM Eco Air Sterilizer / Humidier
INSTRUCTION MANUAL
AAE-50XX05*
www.DHLifelabs.com
Powered by nature.
Delivered by science.
AquaSolvo HOCl technology
TM
*XX is color code, please refer to more information in page 1
MADE IN CHINA
EPA Est.
No. 99117-CHN-1
FDA Registered
No. 3013851416
Filter, Sterilize, Humidify

Table of Contents
Introduction ..........................................1
Safety Instructions .....................................2
Product Overview .....................................4
How It Works .........................................5
Product Specications ..................................5
Unpacking and Setup...................................5
The Control Panel .....................................6
Preparing the Salt Water Solution .........................7
Operating Procedures ..................................8
Cold Evaporation Filter Replacement ......................8
Troubleshooting ......................................9
Customer Service.....................................10
Product Warranty.....................................10

1 2
Introduction
Thank you for purchasing the AquaSolvo
Eco Air Sterilizer with Humidier. This device
incorporates a cold evaporation lter (CEF) with
a hypochlorous acid generator to sterilize the
air.
The AquaSolvo Eco Air Sterilizer with Humidier
is a comprehensive solution to remove the
bacteria and viruses from the air you breathe.
The AquaSolvo Eco Air Sterilizer with Humidier
is available in several colors. The model number
is AAE-50XX05 (XX is the product color code).
Color code: WN is whtie & navy blue
WB is white & brown
The cover's image is model: AAE-50WN05 and
is only for display.
Replacement Filters
Only use genuine D&HLifelabs CleVaFilter
& AquaSoFilter with your AquaSolvo Eco Air
Sterilizer with Humidier. Use of any other
lters may compromise the proper operation
of your unit and potentially void your
warranty.
•Pre-Filter:
Part Number AS05FT-1
Clean every month, or more frequently if
necessary
•CEF:
Part Number AS05FT-2
Replace every 6 months
To purchase replacement lters visit
www.DHLifelabs.com
Safety Instructions
READ THESE SAFETY INSTRUCTIONS BEFORE USE
When using electrical appliances, basic precautions should always be followed to reduce the risk of
re, electric shock, and injury to persons, including the following:
WARNING: to reduce the risk of re or electric shock, do not use this device with any solid-
state speed control device.
!Read all the instructions before operating the
Sterilizer.
!Place the Sterilizer in a location that is
convenient and where it is unlikely to be
bumped or overturned to avoid potential spills.
!DO NOT sit, stand, or place heavy objects on
the Sterilizer.
!The Sterilizer must only be used in the upright
position.
!Do not move the Sterilizer when operating.
!When moving the machine, it must be powered
off and moved carefully to avoid spilling the
water inside. If water is accidentally spilled,
please wipe it dry. If the machine is accidentally
tipped over or falls, water in the tank will spill
inside the machine. It is recommended to
unplug the power cord and allow the water to
completely dry before use.
!Children should not use this equipment alone.
Keep the Sterilizer away from small children
and pets.
!Do not use the Sterilizer outdoors.
!NEVER use the Sterilizer unless it is fully
assembled.
!This product can only be used with the
supplied accessories.
!DO NOT allow foreign objects to enter
ventilation or exhaust opening as this may
cause electric shock or damage to the Sterilizer.
DO NOT block air outlets or intakes.
!When using electrical appliances, always follow
basic precautions to reduce the risk of re,
electric shock, and personal injury.
!Locate the Sterilizer near the outlet and avoid
using an extension cord or power strip.
!This appliance has a polarized plug (one blade
is wider than the other). To reduce the risk of
electric shock, this plug is intended to t only
one way in a polarized outlet. If the plug does
not t fully in the outlet, reverse the plug. If it
still does not t, contact a qualied electrician.
DO NOT attempt to defeat this safety feature.
!Ensure the electrical outlet used with the
Sterilizer is not loose or damaged. A poor
electrical connection can result in overheating
and damage to the power cord. If the outlet
needs to be serviced contact a licensed
electrician for repairs.
!ALWAYS turn the Sterilizer OFF and unplug
from the wall outlet when not in use.
!To disconnect the Sterilizer, make sure it is
powered OFF then grip the plug and pull it
from the wall outlet. NEVER pull the cord to
unplug it.
!Do not use any electrical product that you
believe may be faulty product, or that has been
dropped or damaged in any way.
!Keep the power cord away from hot surfaces.

3 4
Safety Information (Cont.)
!Do not route the power cord under carpet or
cover it with carpet. Route the power cord to
minimize the possibility that someone could
trip over it.
!Do not expose the Sterilizer to excessive
moisture. Avoid operating it where it might
come in contact with water, such as bathrooms,
laundry rooms or other damp places.
!Ensure the electrical outlet used with the
Sterilizer is not loose or damaged. A poor
electrical connection can result in overheating
and damage to the power cord. If the outlet
needs to be serviced contact a licensed
electrician for repairs.
!Disconnect the power before cleaning or
servicing the Sterilizer.
!The Sterilizer is not user serviceable. Do not
attempt to repair the product yourself. In the
event of a failure, contact customer service for
repair or replacement.
!The inside of the tank must be cleaned
frequently, and relled with clean tap water
daily. Leaving dirty water inside the Sterilizer
will cause dirt/scale to form. This can produce
bad odors and cause a potential health hazard.
!The water in the tank is non-potable. Do not
allow animals to drink the water and do not
use it to water plants to avoid damaging their
health.
!If at any time during use of this product if you
feel unwell, turn off the Sterilizer and seek
medical attention.
!Do not add any mineral waters, chemicals,
aromatics or other liquids besides clean tap
water to the water tank. This can damage the
Sterilizer and potentially cause a health hazard.
!Only add tap water below 86° F (30° C).
Product Overview
•Top cover: The cover conceals the cold
evaporation lter and water tank.
•Cold Evaporation Filter Lid (CEF Lid)
•Cold Evaporation Filter (CEF):
Hypochlorous acid is generated inside the
machine, and absorbed by the CEF.
•Water Tank: The water tank includes a water
chamber mounted on a base that houses
the electronics of the sterilizer. The control
panel is located on the front of the base of
the water tank. There is a blue light inside
the water tank that turns on to indicate the
sterilizer is operating.
•Pre-Filter: The pre-lter captures larger
particulate matter
•Control Panel: On the front of the Sterilizer
is a control panel with touch-sensitive
buttons and a digital display. These buttons
are used to control operation of the sterilizer
and change colors to display operating
status.
•Power Cord: Used to connect the
AquaSolvo Eco Air Sterilizer with Humidier
to AC power.
NOTE: Only use non-iodized salt with the
Sterilizer.
•Salt Bottle with Scoop: The Sterilizer is
supplied with a salt bottle with a salt scoop
built into the cap.
NOTE: Do not overll the salt bottle with
too much salt, otherwise it will spill.
Figure 1. Major Components
WATER TANK
SALT BOTTLE
WITH SCOOP
POWER
CORD
PRE-FILTER
TOP COVER
COLD EVAPORATION FILTER LID
COLD EVAPORATION FILTER

5 6
How It Works
The AquaSolvo Eco Air Sterilizer with
Humidier has a two stage cleaning system to
disinfect the air. A fan draws air in through the
pre-lter at the bottom of the sterilizer. Inside,
the air passes through the CEF and exits
through the top cover. The two stages to the
sterilizer are:
•Stage 1: Pre-Filter. The pre-lter has
a screen that captures large airborne
particles.
•Stage 2: CEF. The CEF absorbs the HOCl
water generated in the water tank. The
HOCl water is evaporated as air passes
through the CEF. This disperses the HOCl
molecules throughout the airspace in the
room allowing it to destroy a variety of
bacteria and viruses.
ON/OFF
HOCI disinfection works when on
Fan Speed
(Sleep/2/3) Three levels of fan speed to choose from
Timer
(2H/4H/8H) Set the timer to have the machine turn off
automatically
Sterilize
The light remains on when the machine is on and ash when
electrolysis is working to process HOCl.
You can turn the sterilization function off, then it will work as a
humidier.
Humidity Indicator
Shows the humidity rate in the room
CEF Replacement Indicator
Will remind you to change the CEF
Control PanelUnpacking and Setup
1. Remove the Sterilizer from the box and
check that all the items shown in Figure 1
are included. It is a good idea to retain the
packaging for storing the Sterilizer or in the
event it must be shipped back for service.
2. Remove the top cover and make sure the
CEF and CEF lid are securely in place.
3. Place the Sterilizer on a at, solid surface in
proximity to an AC electrical outlet.
4. Connect the power cord to the Sterilizer,
and route the power cord to the outlet, but
do not plug it in yet. Make sure that the
power cord is out of the way and does not
pose a tripping hazard, and is out of reach
of children and pets.
Congratulations! You are now ready to enjoy
clean safe air using the AquaSolvo Eco Air
Sterilizer with Humidier.
Product Specications
Model Number AAE-50XX05 (XX is the product color code)
Power Consumption 22 Watts
Input Voltage 120 VAC 60Hz
Fan Speed 3 levels (Sleep/ 2/ 3)
Noise (dB(A)) Max. 53
Timer 2H/4H/8H
Water Tank Capacity 2500ml/84.54oz.
HOCl Recipe 3 scoops non-iodized salt: 2500ml/84.54oz. tap water
Material & Finish ABS, Glossy White & Silver belt
Recommended Room Size 540 square feet
Reminder - Filter Replacement Reminder: Cold evaporation lter
- Salt Level Reminder
- Water Level Reminder
Dimensions H13.6"xDia10.6”(H347x Dia270mm)
Net Weight (without water) 7.28 lbs (3.3 kg)
Figure 2. Control Panel

7 8
Preparing the Salt Water Solution
1. Make sure the AC power adapter is
unplugged.
2. Remove the top cover and CEF lid.
NOTE: Only use non-iodized salt with
the Sterilizer.
3. Make sure the CEF is securely in place.
Make sure the CEF lid is turned with the
AquaSolvo logo aligned with the control
panel the water tank.
4. Using the scoop supplied with the Sterilizer,
place 3 scoops of non-iodized salt on top
of the CEF lid as shown .
NOTE: Hard water can shorten the life of
the Sterilizer. Water used should not have a
hardness greater than 100ppm.
5. Close the top cover.
6. Pour fresh tap water over the CEF lid
into the water tank until the water level
reaches the MAX line on the water tank
(2500ml/84.54oz.). Make sure all the salt is
washed off the CEF lid.
7. Plug in the AC power cord to the sterilizer.
Figure 3. Mixing Salt Water Solution
ADD WATER
UNTIL LEVEL
REACHES
MAX LINE
AQUASOLVO
LOGO SHOULD
BE ALIGNED
WITH CONTROL
PANEL
PLACE SALT
ON THESE AREAS
POUR WATER
OVER THIS AREA
OF CEF LID Timer Operation
Press the timer button to toggle through the
options (2H-4H-8H-None). Once selected, an
internal timer controls operation of the Sterilizer
for the selected duration. Once the timer expires,
the sterilizer shuts down and enters the standby
mode. NOTE: Do not use this option if you want
the sterilizer to run continuously.
Humidier Operation
To use the sterilizer as a standard humidier to
increas the humidity in the room:
1. Fill the water tank with clean tap water - DO
NOT add salt to the tank.
2. Press the HOCl disinfection indicator/button
to toggle the HOCl generator off. This will
stop the disinfection function.
Operating Procedures
1. Press the Power ON/OFF button to turn
the Sterilizer on. The unit will play the
start up sound (do-re-mi) and all the
indicators on the control panel will turn
on for 3 seconds.
2. The Power ON/OFF button will be
illuminated white, indicating that the
sterilizer is in standby mode.
3. Press the power ON/OFF button again
to begin operation. The blue light in the
water tank will turn on, and the fan speed
will default to level 2 fan speed and the
HOCl disinfection indicator/button will
illuminate, indicating that the sterilizer is
disinfenting bacteria and viruses from the
air.
4. Press the fan speed button to toggle
the fan speed between sleep, 2, and 3
speeds. When sleep mode is selected,
fan speed is reduced and the blue light
inside the water tank will turn off.
5. Press the power ON/OFF button again to
turn the sterilizer OFF.
CEF Replacement
The CEF should be replaced every six
months, or whenever indicated by the lter
replacement indicator on the control panel.
Unplug the power cord and remove the top
cover. The sterilizer will automatically shut
down.
1. Remove the CEF lid.
2. Unscrew the CEF from the tank and
discard.
NOTE: Handle the new CEF by the end
caps to avoid touching the CEF and
preventing possible contamination of the
lter element.
3. Remove the replacement CEF from
packaging and screw it into the bottom
of the water tank. Plug in the power
cord.
4. Turn on the Sterilizer and press and hold
HOCl air disinfection button for three
seconds to reset the lter life timer.
Note that If you replace the lter before
the accumulated life time is reached, the
lter life timer cannot be reset.
To purchase replacement lters, please
visit: www.DHLifelabs.com

9 10
Troubleshooting
Symptom Probable Cause/Solution
Low air ow Check that Pre-Filter and the air inlet are free from
obstructions and not blocked by dust, trash, etc. Clean
as necessary.
Emits a chlorine (disinfection) smell Chlorine smell is normal. You can change to sleep
mode to minimize the smell in the room.
Air from the Sterilizer smells bad. Check that water tank and CEF are clean. Clean water
tank regularly and replace CEF as necessary.
The Sterilizer has been tipped over or
fallen.
Immediately unplug the power adapter. Lift up the
Sterilizer and wipe off any water on the surface of the
machine. Allow the Sterilizer to completely dry before
resuming operation.
Water added to water tank, but water
level indicator is still ashing
Check that water level is not too high, and that tank is
installed correctly on base. If not, seat the water tank
in securely in place.
For any issues not covered here, contact Customer Assistance.
Customer Service
For assistance with your AquaSolvo Eco Air Sterilizer with Humidier, call our Customer Service Line:
1-855-ETI-SSLI (1-855-384-7754)
8 a.m. - 5 p.m., CST, Monday – Friday
Dernier&Hamlyn Inc.
720 Northgate Parkway
Wheeling, IL 60090
PRODUCT WARRANTY
This 2 year limited warranty applies to repair or replacement of product found to be defective in material or
workmanship. This warranty does not apply to damage resulting from commercial, abusive, unreasonable
use or supplemental damage. Defects that are the result of normal wear and tear will not be considered
manufacturing defects under this warranty. D&HLifelabs IS NOT LIABLE FOR INCIDENTAL OR CONSE-
QUENTIAL DAMAGES OF ANY NATURE, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION TO THE DURATION OF
THIS WARRANTY. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential
damages or limitations on how long an implied warranty lasts, so the above limitations or exclusions may
not apply to you. This warranty gives you specic legal rights, and you also may have other rights which
vary from jurisdiction to jurisdiction. This warranty applies only to the original purchaser of this product
from the original date of purchase.
At its option, D&HLifelabs will repair or replace this product if it is found to be defective in material or
workmanship.
This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use
not in accordance with the instruction manual.
This warranty does not cover the lter except for material or workmanship defects.
FCC STATEMENT
This device complies with related rules, operation is subject to the following two conditions.
(1) This device may not cause harmful interference and,
(2) This device must accept any interference received, including interference that may cause undesired operation.
Company Name: Dernier&Hamlyn Inc.
Address: 720 Northgate Parkway, Wheeling, Illinois, 60090
Telephone Number: 1-855-384-7754
Copyright © 2021 Dernier&Hamlyn Inc. All rights reserved. Revised 2021/12/29

Table of contents
Popular Laboratory Equipment manuals by other brands

MRC
MRC ROVA-100S Operation instructions

Mindeo
Mindeo MP720 quick guide

Fritsch
Fritsch ANALYSETTE 18 operating instructions

KNF
KNF LABOPORT N820.18 EX operating instructions

Sartorius Stedim Biotech
Sartorius Stedim Biotech Flexel Series user manual

Panasonic
Panasonic MIR-H163 Series operating instructions

VWR
VWR Signature ME50 manual

Agilent Technologies
Agilent Technologies 8860 Maintaining

Thermo Scientific
Thermo Scientific Dionex IonPac AS32-Fast-4mm Analytical product manual

PASCO
PASCO ME-8594 quick start guide

Accu-Scope
Accu-Scope Excelis AU-300 Series quick start guide

Ocean Optics
Ocean Optics USB2000 Plus Installation and operation manual