5. Troubleshooting.................................................................................25
5.1 High Back Pressure......................................................................................................................................27
5.1.1 Findingthe Source of High SystemPressure...............................................................................................27
5.1.2 Replacing Column Bed SupportAssemblies (4 mmand 2 mmcolumns only)........................................27
5.1.3 Filter Eluent....................................................................................................................................................28
5.1.4 Filter Samples................................................................................................................................................28
5.2 High Background..........................................................................................................................................28
5.2.1 Preparation of Eluents ...................................................................................................................................28
5.2.2 A Contaminated Trap Column......................................................................................................................29
5.2.3 Contaminated DionexCR-TC Column ........................................................................................................29
5.2.4 A Contaminated Guard orAnalytical Column............................................................................................ 29
5.2.5 Contaminated Hardware................................................................................................................................29
5.2.6 A Contaminated Suppressor..........................................................................................................................29
5.3 Inconsistent Retention Times .....................................................................................................................29
5.3.1 Drifting to Shorter Retention Time...............................................................................................................30
5.3.2 Drifting to Longer Retention Time...............................................................................................................30
5.3.3 Oscillating Retention Times..........................................................................................................................30
5.4 Poor Peak Resolution ...................................................................................................................................31
5.4.1 Loss of Column Efficiency...........................................................................................................................31
5.4.2 Analyte Specific Efficiency Loss .................................................................................................................32
5.4.3 Shortened Retention Times...........................................................................................................................33
5.4.4 Loss of Front-End Resolution.......................................................................................................................34
5.5 Spurious Peaks...............................................................................................................................................34
6. Appendix A –Column Care................................................................35
6.1 Recommended Operation Pressures.........................................................................................................35
6.2 Column Start-Up...........................................................................................................................................35
6.3 Column Storage .............................................................................................................................................35
6.4 Chemical Purity Requirements..................................................................................................................35
6.4.1 Inorganic Chemicals......................................................................................................................................36
6.4.2 Deionized Water............................................................................................................................................36
6.4.3 Solvents..........................................................................................................................................................36
6.5 Column Cleanup............................................................................................................................................37
6.5.1 Choosing the Appropriate Cleanup Solution...............................................................................................38
6.5.2 Column Cleanup Procedure..........................................................................................................................39
7. Appendix B –Quality Assurance Reports............................................40
8. Appendix C –Additional Information.................................................42
8.1 General Information on PEEK™ Tubing ...............................................................................................42