Service Manual Series 51 and 51-1 Motors Service Manual
Troubleshooting
Sluggish system
System operating hot
Excessive noise or vibration
Check Cause Corrective action,,
1Controlorifices Blocked or restricted orifice will cause sluggish
response. Orifices installed to the wrong locations
will cause PCOR controlto be sluggish.
Remove, inspect and clean all orifices. Ensure the
appropriate orifi ces are installed.
2. Threshold setting (proportional
controls) Inappropriately high threshold setting will shift the
motor at the wrong tlme. Checkthreshold setting. AdJust if necessary.
3. Control spoolor piston A sticky 4-way spool or control piston will cause
sluggish response. Clean and inspect the 4-way valve spool and control
piston. Replace if necessary.
4. Pressure com pensator setting Inappropriately low pressure compensati ng setti ng
will shift motorto maximum displacement at lower
pressure
Check pressure compensator setting. Adjust if
necessary.
5. Control input signal An improper or erratic input signalto the control
may cause sluggish response. Check input signal or electric current and correct if
necessary.
Charge pressure lnappropriately low pressure setting at loop
flushing relief valve may cause improper supply
pressure to motor control.
Measure change pressure in forward and reverse.
Adjust loop flushing relief valve if necessary.
1System pressure Inappropriately low system pressure setting may
cause sluggish response. Measure system pressure. Adjust pump pressure
limiter or system relief valve if necessary.
8. Internalleakage Excessive leakage will cause lower charge pressure
and affect performance. Install loop flushing defeat option and monitor case
flow. lf case flow is excessive, motor may require major
repair. Contact your Danfoss service provider.
Check Cause Corrective action
'l Oillevel Insufficient hydraulic fluid will cause overheating. Fill reservoir to proper level,
2. Heat exchanger Blocked heat exchanger or low air flow will not
sufficiently cool the system. Check temperature upstream and downstream of heat
exchanger. Clean, repair, or replace heat exchanger if
necessary.
3. Loop flushing charge pressure Inappropriately high loop flushing relief valve
setting will reduce or prevent loop flushing flow.
lmproper orifice size will not give proper flow for
cooling purposes.
Monitor case drain flow. lf low adjust loop flushing
relief valve setting or replace with orificed type relief.
4. System pressure lf system relief valve settings aretoo fow, excess
heat will be generated. Adjust system relief valve settings.
5. Air in system Entrained air generates heat under pressure and
causes cavitation Look for foam or bubbles in reservoir. Check for leak
on inlet side of charge pump.
6. Internalleakage Excessive internal leakage will overheat the system. Install loop flushing defeat option and monitor case
flow. lf case flow is excessive, motor may require major
repair. Contact your Danfoss service provider.
Check Cause, Corrective action
IOillevelin reservoir Insufficient hydraulic fluid will cause cavitation. Fill reservoir to proper level.
2. Air in system Air bubbles may lead to cavitation. OLookforfoam or bubbles in reservolr. Checkfor leak
on inlet side of charge pump.