Danfoss MP20 Series User manual

Revision history Table of revisions
Date Changed Rev
January 2019 Rebranded to Danfoss Power Solutions 0101
User Manual
MP20V Receiver
2 | ©Danfoss | January 2019 BC292570533618en-000101

Safety instructions General safety....................................................................................................................................................................................4
Safety warnings.................................................................................................................................................................................4
Technical description Dimensions.........................................................................................................................................................................................6
Hardware description..................................................................................................................................................................... 7
Installation Receiver installation........................................................................................................................................................................ 8
Input and output configuration..................................................................................................................................................9
Digital outputs............................................................................................................................................................................. 9
Analog outputs..........................................................................................................................................................................11
Pinout............................................................................................................................................................................................12
Troubleshooting Receiver icon troubleshooting..................................................................................................................................................13
User Manual
MP20V Receiver
Contents
©Danfoss | January 2019 BC292570533618en-000101 | 3

MP20V general safety
The following safety instructions must be read carefully in order to install and use the product properly
and to keep it in perfect working condition and to reduce the risk of misuse.
Potential damage to operator and product.
Do not use this product on machines in potentially explosive atmospheres unless the model is ATEX/
RATEX certified to do so.
•Strictly adhere to the installation instructions contained in this document.
•Make sure that professional and competent personnel carry out the installation.
•Ensure that all site and prevailing safety regulations are fully respected.
•Make sure that this document is permanently available to the operator and maintenance personnel.
•Keep the transmission key when the set is not in use.
•On starting each working day, check to make sure that the STOP button and other safety measures
are working.
•When in doubt, press the STOP button.
•Whenever several sets have been installed, make sure the transmitter is the right one. Identify the
machine controlled on the label for this purpose on the transmitter or by using the display (in case it
has one).
•Service the equipment periodically.
•When carrying out repairs, only use spare parts from Danfoss.
MP20V safety warnings
Potential damage to operator and product.
Follow the guidelines below to reduce risk of injury to the operator and the product.
•Use the device with the manufacturer's battery and battery charger (if applicable).
•Only allow qualified personnel to operate the equipment.
•Always set the STOP button in the off position when not in use.
•Always press STOP before plugging in tether cable (if applicable).
•Do not operate product when visibility is limited.
•Make sure product is compatible with the machine.
•Avoid knocking or dropping the product.
•Do not use the product if a failure is detected.
Changes or modifications not approved by Danfoss can void the user's authority to operate this product.
User Manual
MP20V Receiver
Safety instructions
4 | ©Danfoss | January 2019 BC292570533618en-000101

Quick reference precautions
User Manual
MP20V Receiver
Safety instructions
©Danfoss | January 2019 BC292570533618en-000101 | 5

MP20 dimensions
Dimensions in mm
167.25
82.37
R 2.60
81.55 R 2.60
104.00
149.00
232.00
216.00 R 2.60
167.25
358.74
R 2.60
248.91
31.50
User Manual
MP20V Receiver
Technical description
6 | ©Danfoss | January 2019 BC292570533618en-000101

MP20V hardware description
4
3
5
6
7
8
9
10
11
212
13
1
1. Fixing slots (fixed assembly or anti-vibration)
2. DEUTSCH connector
3. Tether connection
4. External antenna A60 (433) or A70 (870)
5. External EEPROM
6. LCD connection
7. TR800-CE MCX radio
8. CAN connection
9. CAN power supply
10. BUS termination CAN
11. Signaling intern LEDs
12. DEUTSCH connector pinout
13. Switches to control voltage options
User Manual
MP20V Receiver
Technical description
©Danfoss | January 2019 BC292570533618en-000101 | 7

MP20V receiver installation
The below information describes hazards to be aware of during installation and steps to locate the
receiver.
Risk of shock
Completely shut down the machine when installing the receiver.
Check the power supply and shut off the main switch to disconnect the interface cable between the
receiver and the machine's electrical box.
1. Find an easily accessible and clear location with a direct vision between the receiver's antenna and
the transmitter's working area.
2. Optional: If it is difficult to achieve direct vision between the receiver's antenna and the transmitter's
working area, it is recommended to use an extended antenna in a clear location (only for models that
allow an antenna).
In areas of high vibration, the use of dampers is advised.
3. Proceed to connect the power supply. Use the connection block diagram provided with the system,
where the correspondence between the transmitter maneuvers and the receiver's outputs are
detailed.
1234567
15 16 17 18 19 20 21
29 30 31 32 33 34 35
43 44 45 46 47 48 49
57 58 59 60 61 62 63
22 23 24 25 26 27 28
36 37 38 39 40 41 42
50 51 52 53 54 55 56
64 65 66 67 68 69 70
8910 11 12 13 14
4. Check if the electrical installation and verify if there's an option to connect the neutral or the ground
cable. In that case, don't forget to connect the ground cable.
The use of fireproof or flame retardant cables are recommended for the connection.
User Manual
MP20V Receiver
Installation
8 | ©Danfoss | January 2019 BC292570533618en-000101

MP20 input and output configuration
The MP20 includes a 7.5A permeable internal fuse.
MP20 digital outputs
The digital outputs K1-K4 have a common contact at pin 47 of the connector. This pin is connected to pin
46 (stop) for powering up this group of outputs. Maximum 2A per output. It is recommended to use K1
for by-pass valve.
The digital output K5-K12 have a common contact at pin 48 of the connector. This pin is connected to pin
45 (stop) for powering up this group of outputs. Maximum 2A per output.
As an alternative, the K5-K12 output group can be connected directly to the external general power
supply in order to provide a higher capacity of current.
User Manual
MP20V Receiver
Installation
©Danfoss | January 2019 BC292570533618en-000101 | 9

User Manual
MP20V Receiver
Installation
10 | ©Danfoss | January 2019 BC292570533618en-000101

MP20V analog outputs
The analogue outputs, that are different for MP20A or MP20V, have a common contact at pin 47 of the
connector. This pin is connected to pin 46 (stop) for powering up the 1-8 outputs.
Nsa1-Nsa8 have a common contact at pin 47 of the connector. Pin 47 connects with pin 46 (STOP) in
order to feed nSA1-nSA8 outputs. Maximum 20mA per output.
The MP20V allows to choose the control voltage in order to set the output power with the selection of 2
switches. Control voltage options: 0-5V, 0-10V, 0-Vcc.
User Manual
MP20V Receiver
Installation
©Danfoss | January 2019 BC292570533618en-000101 | 11

MP20V pinout
1234567
15 16 17 18 19 20 21
29 30 31 32 33 34 35
43 44 45 46 47 48 49
57 58 59 60 61 62 63
22 23 24 25 26 27 28
36 37 38 39 40 41 42
50 51 52 53 54 55 56
64 65 66 67 68 69 70
8910 11 12 13 14
Pin Description Pin Description
1 CAN-H 36 SA-7
2 CAN-GND 37 SA-6
3 CAN-L 38 SA-5
4 - 39 SA-4
5 - 40 SA-3
6 - 41 SA-2
7 IN-4 42 SA-1
8 - 43 PSWF
9 - 44 HAND
10 - 45 STOP
11 - 46 STOP
12 - 47 ABV; K1-4
13 - 48 K5-K12
14 - 49 Vdc8
15 K11 50 Vdc7
16 K9 51 Vdc6
17 K7 52 Vdc5
18 K5 53 Vdc4
19 K3 54 Vdc3
20 K1 55 Vdc2
21 Err8 56 Vdc1
22 Err7 57 GND
23 Err6 58 +RRC
24 Err5 59 +12/24V
25 Err4 60 IN-3
26 Err3 61 IN-2
27 Err2 62 IN-1
28 Err1 63 GND-8
29 K12 64 GND-7
30 K10 65 GND-6
31 K8 66 GND-5
32 K6 67 GND-4
33 K4 68 GND-3
34 K2 69 GND-2
35 SA-8 70 GND-1
User Manual
MP20V Receiver
Installation
12 | ©Danfoss | January 2019 BC292570533618en-000101

Receiver icon troubleshooting
Icon Description Action
Power failure Check the receiver power supply
Hardware error Contact distributor; replace receiver
CAN error Contact your distributor
Repose state due to active stop Release stop button and turn transmitter on
Repose state due to passive stop Reestablish link to activate the transmitter
Linked state Correct link
Correct ID (link quality as indicated by the bar) In case of no signal, check if the transmitter is turned on
Incorrect ID In case of interference, change frequency channel
RF signal detected In case of interference, change frequency channel
Mask error Contact your distributor
User Manual
MP20V Receiver
Troubleshooting
©Danfoss | January 2019 BC292570533618en-000101 | 13

User Manual
MP20V Receiver
14 | ©Danfoss | January 2019 BC292570533618en-000101

User Manual
MP20V Receiver
©Danfoss | January 2019 BC292570533618en-000101 | 15

Danfoss Power Solutions is a global manufacturer and supplier of high-quality hydraulic and
electric components. We specialize in providing state-of-the-art technology and solutions
that excel in the harsh operating conditions of the mobile off-highway market as well as the
marine sector. Building on our extensive applications expertise, we work closely with you to
ensure exceptional performance for a broad range of applications. We help you and other
customers around the world speed up system development, reduce costs and bring vehicles
and vessels to market faster.
Danfoss Power Solutions – your strongest partner in mobile hydraulics and mobile
electrification.
Go to www.danfoss.com for further product information.
We offer you expert worldwide support for ensuring the best possible solutions for
outstanding performance. And with an extensive network of Global Service Partners, we also
provide you with comprehensive global service for all of our components.
Local address:
Danfoss
Power Solutions GmbH & Co. OHG
Krokamp 35
D-24539 Neumünster, Germany
Phone: +49 4321 871 0
Danfoss
Power Solutions ApS
Nordborgvej 81
DK-6430 Nordborg, Denmark
Phone: +45 7488 2222
Danfoss
Power Solutions (US) Company
2800 East 13th Street
Ames, IA 50010, USA
Phone: +1 515 239 6000
Danfoss
Power Solutions Trading
(Shanghai) Co., Ltd.
Building #22, No. 1000 Jin Hai Rd
Jin Qiao, Pudong New District
Shanghai, China 201206
Phone: +86 21 3418 5200
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without subsequent changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
©Danfoss | January 2019 BC292570533618en-000101
Products we offer:
•DCV directional control
valves
•Electric converters
•Electric machines
•Electric motors
•Hydrostatic motors
•Hydrostatic pumps
•Orbital motors
•PLUS+1®controllers
•PLUS+1®displays
•PLUS+1®joysticks and
pedals
•PLUS+1®operator
interfaces
•PLUS+1®sensors
•PLUS+1®software
•PLUS+1®software services,
support and training
•Position controls and
sensors
•PVG proportional valves
•Steering components and
systems
•Telematics
Comatrol
www.comatrol.com
Turolla
www.turollaocg.com
Hydro-Gear
www.hydro-gear.com
Daikin-Sauer-Danfoss
www.daikin-sauer-danfoss.com
Other manuals for MP20 Series
1
This manual suits for next models
1
Table of contents
Other Danfoss Receiver manuals

Danfoss
Danfoss SonoCollect 210 User manual

Danfoss
Danfoss RZ1 User manual

Danfoss
Danfoss SonoRead 868 User manual

Danfoss
Danfoss MP20 Series User manual

Danfoss
Danfoss R13 B User manual

Danfoss
Danfoss RX1 User manual

Danfoss
Danfoss RX1-S V2 User manual

Danfoss
Danfoss RZ1 User manual

Danfoss
Danfoss SonoCollect 210 User manual

Danfoss
Danfoss SonoRead 868 User manual