iBootBar Quick Start © 2015 Dataprobe Inc. V150715E
What’s Included
•iBootBar Unit
•Rack Mounting Ears
•Network Cable
•Quick Start Guide
Available Online at
dataprobe.com/support_ibootbar.html
•Complete Product Manual
•Device Management Utility
•Latest iBootBar Firmware
•Software Developer Tools
Front Panel
Rear Panel – NEMA Versions
Rear Panel – IEC Versions
Quick Start Defaults
IP address 192.168.0.254
User Credentials Username: admin
Password: admin
Command Line Quick Start:
To view outlet status iBootBar> get outlets
To turn on off outlet 1 iBootBar> set outlet 1 off
To reboot outlet 2 iBootBar> set outlet 2 cycle
Quick Start Guide
Outlet Status
Indicators Reset Pushbutton
(Recessed) Mains (Inlet) Power
Indicators
Linecord for NEMA
Models
Circuit Breaker(s)
2nd Linecord
on -2N Models
8 NEMA 5-15
Outlets
Serial
(DCE)
Network
(10/100)
Phone Line
(Modem Versions)
Expansion for Cluster
Configurations
8 IEC C13 Outlets
IEC C-14 (10 Amp) or
IEC C-20 (20 Amp) Inlets
2nd Inlet on -2C Models
Circuit Breaker(s)
iBootBar Quick Start © 2015 Dataprobe Inc. V150715E
Setting the IP address using CLI
Connect to the iBootBar for initial setup using the Command Line Interface (CLI) to set the IP Address. You will need to be on the
same local subnet (192.168.0.xxx) to perform the initial configuration.
These are the basic commands to set the network parameters. After setting these parameters, the iBootBar will need to be rebooted
for the settings to take effect. Any command that requires rebooting of the iBootBar will provide a prompt to do so. All commands
may be entered as required before rebooting.
Example: Telnet to default IP address 192.168.0.254
iBootBar Rev 1.5a.276
User Name: admin
Password: *****
iBootBar > set ipaddress 192.168.1.3
Reboot Required!
OK
iBootBar > set subnet 255.255.255.0
Reboot Required!
OK
iBootBar > set gateway 192.168.1.7
Reboot Required!
OK
iBootBar > reboot
IP Address = 192.168.1.3
Serial Port
The iBootBar has a 9 pin D subminiature connector for RS-232
serial control. The connector is configured as DCE for direct
connection to a laptop or other terminal device. Default serial
parameters are 115,200 bps, 8 data, no parity, 1 stop bit
(115200,8,n,1). Flow control is not used.
Web Browser Control
The iBootBar web interface provides the easiest
means of operating the outlets and monitoring the
current status of the units. One or more outlets can
be simultaneously controlled with a few mouse clicks.
In cluster configurations, all 128 outlets can be
managed from the web pages.
To Control any of the outlets, Click on the checkbox
next to one or more outlets, then click the desired
new status, On Off or Cycle.
When Cycle is selected, the outlet(s) will cycle for
the amount of time set in the Cycle box. When mor
e than one outlet is controlled to turn on, there will
be a delay between outlets turning on, as set by the
Delay box.
Pin No
Description
2
Receive Data
3
Transmit Data
5
Signal Ground
Additional Useful CLI Commands
get outlets
set outlet <1-8> <on/off/cycle>
get network
help
help <network/outlets/device/users/groups…>
logout
See all the CLI Commands in the complete iBootBar
manual, available at dataprobe.com/support
Important Safety Instructions
When using this product, basic safety precautions should always be followed to reduce the risk of fire,
electric shock, and injury to persons, including the following:
1. Read and understand all instructions.
2. Follow all warnings and marked on the product.
3. Unplug this product from the wall outlet before cleaning. Do not use liquid
cleaners or aerosol cleaners. Use a damp cloth for cleaning.
4. Do not use this product in an outdoor environment or near water, for
example, near a bath tub, wash bowl, kitchen sink, or laundry tub, in a wet
basement, or near a swimming pool.
5. Do not place this product on an unstable cart, stand, or table. The product
may fall, causing serious damage to the product.
6. Slots and openings in this product and the back or bottom are provided for
ventilation to protect it from overheating; these openings must not be
blocked or covered. The openings should never be blocked by placing the
product on the bed, sofa, rug, or other similar surface. This product should
never be placed near or over a radiator or heat register. This product
should not be placed in a built-in installation unless proper ventilation is
provided.
7. This product should be operated only from the type of power source
indicated on the marking label. If you are not sure of the type of power
supply to your home, consult your dealer or local power company.
8. This product is equipped with a three wire grounding type plug, a plug
having a third (grounding) pin. This plug will only fit into a grounding type
power outlet. This is a safety feature. If you are unable to insert the plug
into the outlet, contact your electrician to replace your obsolete outlet. Do
not defeat the safety purpose of the grounding type plug. Do not use a 3-
to-2 prong adapter at the receptacle; use of this type adapter may result in
risk of electrical shock and/or damage to this product.
9. Do not allow anything to rest on the power cord. Do not locate this product
where the cord will be abused by persons walking on it.
10. Do not overload wall outlets and extension cords as this can result in the
risk of fire or electric shock.
11. Never push objects of any kind into this product through slots as they may
touch dangerous voltage points or short out parts that could result in a risk
of fire or electrical shock. Never spill liquid of any kind on the product.
12. To reduce the risk of electrical shock, do not disassemble this product, but
take it to a qualified serviceman when some service or repair work is
required. Opening or removing covers may expose you to dangerous
voltages or other risks. Incorrect re-assembly can cause electric shock
when the appliance is subsequently used.
13. Unplug this product from the wall outlet and refer servicing to qualified
service personnel under the following conditions:
a) When the power supply cord or plug is damaged or frayed.
b) If liquid has been spilled into the product.
c) If the product has been exposed to rain or water.
d) If the product does not operate normally by following the operating
instructions. Adjust only those controls that are covered by the
operating instructions because improper adjustment of other controls
may result in damage and will often require extensive work by a
qualified technician to restore the product to normal operation.
e) If the product has been dropped or has been damaged.
f) If the product exhibits a distinct change in performance.
14. Avoid using a telephone (other than a cordless type) during an electrical
storm. There may be a remote risk of electric shock from lightning.
15. Do not use the telephone to report a gas leak in the vicinity of the leak.
16. Do not exceed the maximum output rating of the auxiliary power receptacle.
Technical Support, Returns and Warranty
Dataprobe Technical Support is available 8:30AM to 5:30PM ET to assist you in the installation and operation of this product. To
obtain Technical Support call 201- 934-5111, or Email us at tech@dataprobe.com. Please have the following information available
when you call:
• Model of Product
• Lot and Version Numbers
• Data of Purchase
• Name of Seller (if other than Dataprobe)
If you purchased this product through an Authorized Dataprobe Reseller, you should contact them first, as they may have information
about the application that can more quickly answer your questions.
3 Year WARRANTY
Download complete manual or visit dataprobe.com/support/dataprobe_warranty.pdf

Other manuals for iBootBar

1

Other Dataprobe Power Distribution Unit manuals

Dataprobe 1530041 User manual

Dataprobe

Dataprobe 1530041 User manual

Dataprobe iBootBar iBB-N15 Owner's manual

Dataprobe

Dataprobe iBootBar iBB-N15 Owner's manual

Dataprobe sBB-N15 Owner's manual

Dataprobe

Dataprobe sBB-N15 Owner's manual

Popular Power Distribution Unit manuals by other brands

ASTi ACE-RIU Technical user guide

ASTi

ASTi ACE-RIU Technical user guide

Tesla TI4200 GPU-24 user manual

Tesla

Tesla TI4200 GPU-24 user manual

Amina APU-RS8 Installer's guide

Amina

Amina APU-RS8 Installer's guide

DIGIPDU SMLW 16 Series Operation manual

DIGIPDU

DIGIPDU SMLW 16 Series Operation manual

A. & H. Meyer Netbox Smart installation guide

A. & H. Meyer

A. & H. Meyer Netbox Smart installation guide

Siemens Siprotec 5 7SS85 Techical data

Siemens

Siemens Siprotec 5 7SS85 Techical data

Essential Audio Tools Mains Multiplier 6+ user manual

Essential Audio Tools

Essential Audio Tools Mains Multiplier 6+ user manual

D&R ELECTRONICS PDU14-K Installation & operation manual

D&R ELECTRONICS

D&R ELECTRONICS PDU14-K Installation & operation manual

Siemens SDV7 instruction manual

Siemens

Siemens SDV7 instruction manual

LEGRAND PLUGMOLD PM48TC installation instructions

LEGRAND

LEGRAND PLUGMOLD PM48TC installation instructions

IBM Rack Power Distribution Unit Installation and maintenance guide

IBM

IBM Rack Power Distribution Unit Installation and maintenance guide

Vdwall DS4-8 user manual

Vdwall

Vdwall DS4-8 user manual

BS 9902A instruction manual

BS

BS 9902A instruction manual

Denali POWERHUB2 installation instructions

Denali

Denali POWERHUB2 installation instructions

Easee Equalizer quick guide

Easee

Easee Equalizer quick guide

S&C VacuFuse Installation and operation

S&C

S&C VacuFuse Installation and operation

Gewiss GW 68 017 N manual

Gewiss

Gewiss GW 68 017 N manual

Clever Electronics NPM2000 user manual

Clever Electronics

Clever Electronics NPM2000 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.