Avance
1-2 M1204616
Intended use
The Avance anesthesia system combines our highly advanced
anesthesia delivery, the very best in patient monitoring, and care
information management. The contemporary, compact design
addresses many ergonomic considerations including an efficient
cable management solution and storage system and an extra large
work surface area. Optional, integrated features include auxiliary O2
and suction control. The Avance system offers improved usability
through integration of ventilation, gas delivery and gas monitoring (E
and M-Series respiratory gas module capable) on a full-color 12-inch
display. This system also features electronic gas mixing of upto three
gases.
This anesthesia system is designed for mixing and delivering
inhalation anesthetics, Air, O2, and N2O. The anesthesia system’s
small breathing system volume allows an anesthetic agent delivery
response time of less than 7 seconds. (Agent response time defined
as achieving 90% of the setting change measured while in non-circle
circuit with a 2 l/min fresh gas flow.)
This anesthesia system uses SmartVent ventilation technology
offering Volume Control Ventilation with tidal volume compensation
and electronic PEEP. The proven SmartVent technology also
features optional Pressure Control Ventilation, Pressure Support
Ventilation with an Apnea Backup (PSVPro) that is used for
spontaneously breathing patients, Synchronized Intermittent
Mandatory Ventilation (SIMV) modes, Pressure Control Ventilation-
Volume Guarantee (PCV-VG), Constant Positive Airway Pressure/
Pressure Support Ventilation (CPAP/PSV), and VCV cardiac bypass.
In Volume Control Ventilation, a patient can be ventilated using a
minimal tidal volume of 20 ml. In Pressure Control Ventilation,
volumes as low as 5 ml can be measured. These advanced features
allow for the ventilation of neonates to adult patients.
This anesthesia system uses the Advanced Breathing System (ABS).
This integrated breathing system is easy to remove and disassemble
and is fully autoclavable. Its fully integrated design enhances the
system’s elegance while minimizing tube connections, minimizing
circuit volume, and increasing the work surface area.
This anesthesia system is designed for expansion and upgrades, so it
is easy to add new technologies and ventilation capabilities without
investing in a new system.
This anesthesia system is not suitable for use in an MRI environment.
This system must only be operated by authorized medical personnel
well trained in the use of this product. It must be operated according
to the instructions in this User’s Reference manual.
WARNING Explosion Hazard. Do not use this system with flammable
anesthetic agents.