Via monte Nero, 40/B – 21049 TRADATE (VA) ITALY
P one: +39 (0)331841070 Fax:+39 (0)331841950 - e-mail:[email protected] - www.datexel.it
DAT 4631 B
DAT 4631 B
Isolated Doubler / Converter
for RTD and resistance
configurable by Dip Switch or PC
FEATURES
Configurable input for RTD and resistance
Double output configurable in current or voltage
Configurable by dip switch or PC
High accuracy
On field reconfigurable
Galvanic isolation among the ways
EMC compliant – CE mark
Suitable for DIN rail mounting in compliance
with EN 50022 and EN 50035
GENERAL DESCRIPTION
T e isolated doubler/converter DAT 4631 B is able to measure and linearise t e standard RTDs and resistances wit 2 or 3 wires cable compensation .
In function of programming, t e measured values are converted in a current or voltage signal. T e device guarantees ig accuracy and performances
stability bot versus time and temperature.
T e programming is made by t e dip-switc located in t e window on t e side of t e enclosure. By means of dip-switc es it is possible to select t e input
type and range and t e output type wit out recalibrate t e device.
Moreover, by Personal Computer t e user can program all of t e device's parameters for is own necessity; t e configuration by PC allows to program
t e two outputs wit two independent settings. For all t e sensors it is possible to set t e cable compensation wit 2 or 3 wires.
Moreover it is available t e option of alarm for signal interruption (burn-out) t at allows to set t e output value as ig or low out of scale .
T e 1500 Vac galvanic isolation on all ways (input, outputs and power supply) eliminates t e effects of all ground loops eventually existing and allows t e
use of t e converter in eavy environmental conditions found in industrial applications.
T e DAT 4631 B is in compliance wit t e Directive 2004/108/EC on t e Electromagnetic Compatibility.
It is oused in a plastic enclosure of 12.5 mm t ickness suitable for DIN rail mounting in compliance wit EN-50022 and EN-50035 standards.
USER INSTRUCTIONS
T e converter must be powered by a direct voltage applied to t e terminals Q and R.
T e analog c annel measures t e value from t e sensor connected to t e terminals t e I, L and G and transmits t e output measures on t e terminals N
and M (OUT A) and t e terminals P and O (OUT B).
T e input and output connections must be made as s own in t e section "Connections".
It is possible to configure t e converter on field by dip-switc or Personal Computer as s own in t e section “ Programming ". T e configuration by dip-
switc es can be made also if t e device is powered (note: after t e configuration t e device takes some seconds to provide t e rig t output measure ).
TECHNICAL SPECIFICATIONS (Typical at 25 °C and in nominal conditions)
Sensor excitation current
RTD,Res 500 uA
Line resistance influence (1)
RTD 3 wires 0.05%/Ω (50 Ω max balanced)
Linearity (1)
RTD ± 0.1 % f.s.
Thermal drift (1)
Full scale ± 0.01% / °C
Input type Min Max Min.Span
TEMPERATURE AND HUMIDITY
Operative temperature -20°C .. +60°C
Storage temperature -40°C.. +85°C
Humidity (not condensed) 0 .. 90 %
Output type Min Max Min Span
HOUSING
Material Self-extinguis ing plastic
Mounting DIN rail in compliance
wit EN-50022 and
EN-50035
Weig t about 90 g.
Output calibration
Current ± 7 uA
Voltage ± 5 mV
Power supply voltage 18 .. 30 Vdc
Reverse polarity protection 60 Vdc max
EMC ( for industrial environments )
Immunity EN 61000-6-2
Emission EN 61000-6-4
Current consumption
Current output 55 mA max.
Voltage output 25 mA max.
Burn out values
Max. output value 22 mA or 10.6 V
Min. output value 0 mA or -0.6 V
Current 0 mA 20 mA 4 mA
Voltage 0 V 10 V 1 V
(1)referred to t e input Span (difference between max. and min.)
Response time (10÷ 90%) about 500 ms
Output load Resistance Rload
Current output < 500 Ω
Voltage output > 10 KΩ
S ort circuit current 26 mA max.
ISOLATION
Among all ways 1500 Vac,
50 Hz, 1 min
POWER SUPPLY
INPUT OUTPUT (2 CHANNELS)
RTD (2, 3 wires)
Pt100 -200°C 850°C 50°C
Pt1000 -85°C 185°C 30°C
Ni100 -60°C 180°C 50°C
Ni1000 -60°C 150°C 30°C
RES. (2, 3 wires) 0 Ω 500 Ω 50 Ω
0 Ω2000 Ω 50 Ω
Input Calibration (1)
RTD t e ig er of ±0.1% and ±0.2°C
Low Res. t e ig er of ±0.1% and ±0.15 Ω
Hig Res. t e ig er of ±0.2% and ± 1 Ω
RTD/RES
VmA
VmA
DC SUPPLY
OUTPUT A
+
INPUT
OUTPUT B
CONFIGURATION BY PC
By software DATESOFT it is possible to:
- set t e default programming of t e device;
- program t e options not available wit t e dip-switc ;
(burn-out level, etc...);
- read, in real time, t e input and output measures;
- follow t e dip-switc es configuration wizard.
To configure t e device follow t e next steps:
1) Power-on t e device.
2) Open t e protection plastic label on t e front of t e device.
3) Connect t e interface PRODAT to t e PC (COM port)
and to t e device (PGRM connector).
4) Open DATESOFT.
5) Select t e COM port in use.
6) Click on “Open COM”.
7) Click on “Program”.
8) Set t e programming data.
9) Click on “Write” to send t e programming data to t e device.
Warning: during these operations the device must always be powered and the TX/RX cable always connected.
For information about D TESOFT refer to the software's user guide.
DIP SWITCH CONFIGURATION TABLES
PROGRAMMING
J1
TX/RX CABLE
PRODAT
COM PORT
P.C.
V+ V
QR
PGRM
Plastic label protection
DAT
POWER SUPPLY
UNIT
1) Open t e suitable door on t e side of t e device.
2) Set t e input type by t e dip-switc SW1 [1..4] (see TAB.1)
3) Set t e minimum input scale value (Zero) by t e dip-switc SW1 [5..8] (see TAB.3)
4) Set t e maximum input value (Full scale) by t e dip-switc SW2 [1..6] (see TAB.3)
5) Set t e output type by t e dip-switc SW2 [7..8] (see TAB.2)
NOTE:
- It is also possible to set t e dip-switc es using t e wizard of t e configuration software following t e procedure described in t e section ”Configuration by
PC” until t e step 6 and clicking on “Switc ”.
CONFIGURATION BY DIP SWITCHES
87654321
87654321
SW1
SW2
Input type
Output
Full scale
Zero
OFF
ON
NOTES:
* For all t e input type selected by dip-switc es, t e compensation of wires is
fixed at 3.
* To configure t e range for t e input type selected (TAB.1) refer to t e section
of t e TAB.3 on next page relative to it (ex: for Pt100 use t e table TAB.3c ).
* If t e dip-switc es SW1 [1..4] are all set in t e position 0 (“EPROM”), t e
device will follow t e configuration programmed by PC ( input type and range,
output type and range and options).
* If t e dip-switc es SW1 [5..8] are all set in t e position 0 (“Default”), t e
device will follow t e input scale programmed by PC for t e input type
selected by t e dip-switc es SW1 [1..4]
* Eventual wrong dip-switc es settings will be signalled by t e blinking of t e
led “PWR”.
0-20 mA
SW2
87
TAB.2
Output settings
4-20 mA
0-10 V
0-5 V
SW1
321
EPROM *
TAB.1
Input type settings
R 2KΩ
Pt100
Ni100
Pt1000
Ni1000
R 500Ω
4
SW1
321
---
4
---
---
---
---
---
---
---
---
- Input type Pt100
- Zero value -50 °C
- Full scale value 200 °C
- Output type 4-20 mA
EX. of configuration: SW1 =
SW2 =
Zero
SW1
8
765
Default
0
150
300
350
400
450
500
550
600
650
700
750
800
Full scale
SW2
4321
Default
500
520
540
560
580
600
620
640
660
680
700
720
740
760
780
5 6
SW2
4321
800
820
840
860
880
900
920
940
960
980
1000
1025
1050
1075
1100
5 6
SW2
4321
1175
1200
1225
1250
1275
1300
1325
1350
1375
1400
1425
1450
1475
1500
5 6
SW2
4321
1650
1700
1750
5 6
1800
1850
1900
1950
2000
2000
2000
2000
2000
250
200
1125 1550
2000
2000
2000
16001150
Ω Ω Ω Ω Ω
TAB.3a – Settings for Resistance < 2KO m
Zero
SW1
8
765
Default
0
10
40
50
75
100
125
150
175
200
225
250
300
Ω
Full scale
SW2
4321
Default
50
55
60
65
70
75
80
85
90
95
100
110
115
120
Ω
5 6
SW2
4321
125
130
135
140
145
150
155
160
165
170
175
180
185
190
195
5 6
SW2
4321
220
230
240
250
260
270
280
290
300
310
320
330
340
350
5 6
SW2
4321
380
390
400
5 6
410
420
430
440
450
460
470
500
500
30
20
200 360
480
490
500
370210
105
Ω Ω Ω
TAB.3b – Settings for Resistance < 500 o m
Zero
SW1
8765
Default
-200
-150
-40
-30
-20
-10
0
5
10
20
30
50
100
°C
Full scale
SW2
4
321
Default
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
°C
5 6
SW2
4
321
75
80
85
90
95
100
110
120
130
140
150
160
170
180
190
°C
5 6
SW2
4
321
220
230
240
250
260
270
280
290
300
310
320
330
340
350
°C
5 6
SW2
4
321
380
390
400
°C
5 6
425
450
475
500
525
550
600
800
850
-50
-100
200 360
650
700
750
370210
TAB.3c – Settings for Pt100, Pt1K, Ni100, Ni1K
Datexel reserves its rig ts to modify totally or in part t e c aracteristics of its products wit out notice at any time .
CONNECTIONS
DAT 4631B / Pt100 / 0 ÷ 200 °C / 4 ÷ 20 mA / 3 wires
Input type
Input range
Output range
Options
HOW TO ORDER
T e device is provided as requested on t e Customer's order.
Refer to t e section “Programming” to determine t e input and output ranges.
In case of t e configuration is not specified, t e parameters must be set by t e user.
ORDER CODE EXAMPLE:
INSTALLATION INSTRUCTIONS
T e device is suitable for fitting to DIN rails in t e vertical position.
For optimum operation and long life follow t ese instructions:
When the devices are installed side by side it may be necessary to
separate them by at least 5 mm in the following cases:
- If panel temperature exceeds 45°C.
- Use of ig power supply value ( > 27 Vdc ).
- Use of output current.
Make sure t at sufficient air flow is provided for t e device avoiding to
place raceways or ot er objects w ic could obstruct t e ventilation slits.
Moreover it is suggested to avoid t at devices are mounted above
appliances generating eat; t eir ideal place s ould be in t e lower part
of t e panel.
Install t e device in a place wit out vibrations.
Moreover it is suggested to avoid routing conductors near power signal
cables (motors, induction ovens, inverters etc...) and to use s ielded
cable for connecting signals.
LIGHT SIGNALLING
LED COLOUR STATE DESCRIPTION
PWR GREEN ON
OFF
Device powered
Device not powered
BLINKING Wrong dip-switc es setting
INPUT
POWER SUPPLY
OUTPUT
ED.03.08 R.04
DIMENSIONS (mm)
90
112
PGRM
12.5
+
-
Vdc
Q
R
Rload
+
N
M
V
+
mA
Vout
Rload
Rload
+
P
O
V
+
mA
Vout
Rload
CHANNEL A
CHANNEL B
ISOLATION STRUCTURE
POWER SUPPLY
OUTPUT A
OUTPUT B
INPUT
Note: terminals H, E and F not connected (NC)
I
G
RTD/RES 2W
I
L
G
RTD/RES 3W

Other Datexel Media Converter manuals

Datexel DAT 3016 User manual

Datexel

Datexel DAT 3016 User manual

Datexel DAT 4532 C Operating and maintenance instructions

Datexel

Datexel DAT 4532 C Operating and maintenance instructions

Datexel DAT 4530 User manual

Datexel

Datexel DAT 4530 User manual

Popular Media Converter manuals by other brands

Extron electronics DSC HD-HD 4K Plus A Series user guide

Extron electronics

Extron electronics DSC HD-HD 4K Plus A Series user guide

LinMot 0150-3134 installation guide

LinMot

LinMot 0150-3134 installation guide

SoundTraxx tsunami soundcar user guide

SoundTraxx

SoundTraxx tsunami soundcar user guide

Esoteric G-25U owner's manual

Esoteric

Esoteric G-25U owner's manual

König KN-HDMICON30 manual

König

König KN-HDMICON30 manual

Lika LD25 Series user manual

Lika

Lika LD25 Series user manual

Ensemble Designs BrightEye 24 user guide

Ensemble Designs

Ensemble Designs BrightEye 24 user guide

Puls CD5.241-S1 installation manual

Puls

Puls CD5.241-S1 installation manual

Resol PSW Basic Mounting, Electrical Connection, Adjustment

Resol

Resol PSW Basic Mounting, Electrical Connection, Adjustment

Baumer Hubner Berlin OG 70 Mounting and operating instructions

Baumer

Baumer Hubner Berlin OG 70 Mounting and operating instructions

Transition Networks J/E-CX-TBT-01 user guide

Transition Networks

Transition Networks J/E-CX-TBT-01 user guide

Absolute Process Instruments DuoPak APD 2016 manual

Absolute Process Instruments

Absolute Process Instruments DuoPak APD 2016 manual

M-Audio Flying Cow user guide

M-Audio

M-Audio Flying Cow user guide

Allied Telesis AT-IMC1000TP/SFP user manual

Allied Telesis

Allied Telesis AT-IMC1000TP/SFP user manual

ICT ICT206012-100AI2 instruction manual

ICT

ICT ICT206012-100AI2 instruction manual

Massoth eMOTION M manual

Massoth

Massoth eMOTION M manual

Converters.TV TruVolume Operation manual

Converters.TV

Converters.TV TruVolume Operation manual

TRENDnet TFC-110S20D3i Specifications

TRENDnet

TRENDnet TFC-110S20D3i Specifications

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.