Davcor Smartlock Digital 4300 Quick start guide

V1.0_0212 | Division of Davcor Group Pty Ltd | www.smartlock.com.au | www.smartlock.co.nz
66E
Supra v1.10
MASTER SETUP AND OPERATIONAL INSTRUCTIONS
LOCK OPERATING CONVENTIONS:
LOCK USERS FUNCTIONS
All locks are shipped from the factory in pre-setup mode,
with no features installed.
EXIT PRE-SETUP
KEYPAD SETUP
MASTER FUNCTIONS
LOCKS ENTRY DEVICE OPTIONS
+User ID plus 6 digit PIN
+Time Delay: Delay 01-99; Open 01-19
+Duress (+/- last digit of combination, if enabled)
+Single Access Mode - one combination required to open.
+Dual Access Mode - two combinations required to open
(if enabled.)
+Wrong Try (4 wrong combinations = 5 minute lock out)
+If a mistake is made, wait thirty (30) seconds and
repeat operation.
+Double signal - two (2) LED ashes and two (2) beeps -
indicates entry is valid or accepted.
+Triple signal - three (3) LED ashes and three (3) beeps -
indicates invalid or not accepted.
Master User - Lock setup, add Users, and Master Reset
Manager User - Open Lock, Enable/Disable Users,
Delete/Reinstate User, set Time Delay, and Audit
Access User - Open Lock
+User 02 -30
+User 31 (Time Delay Override, if enabled)
Lock will open when 1 is pressed.
1. Press and hold the “0” key until unit double signals.
2. Enter the default Master Combination, 00 5-5-5-5-5-5.
+ Unit will signal twice.
Lock is now in setup and test mode.
+ONLY the Master can enroll manager and users!
+ONLY the manager can select operational modes: Time
Delay Override, Dual Mode, or Silent Alarm. (Special
Function 8, see conguration chart.)
To enroll/activate the Manager (Master only)
To enroll/activate Users (Master only)
4300
Dual-Handed
Swing bolt
6040
Dead bolt 3125
Round Entry
8130
(Optional)
NOTE: User IDs are underlined in the instruction
for identication purposes.
NOTE: Perform all Administrative Functions with the door open.
NOTE: User 31 must be activated to use Time Delay Override.
NOTE: the Manager can open the lock, but all other “Manager
Function” will not be available until the Lock is in Operational
Mode (see Exiting Setup Mode.)
NOTE: Each combination must be changed independently at the
Lock. When selecting a combination, do not use a birthday or
other predictable information that could give correlation between
the user and the combination.
1. Enter Master combination (00 555555) and hold down last digit
of combination until unit double signals and the LED stays on.
2. PRESS 1 (add user).
3. Enter Manager ID 01; lock should beep twice and LED stays on
4. Enter the Manager ID 01 and combination XXXXXX. (Example:
01 123456)
5. Re-enter 01 XXXXXX
6. The Lock will double signal if the operation was successful, and
triple signal if not accepted.
Key press sequence – 00 555555(hold last) 1, 01, 01 123456, 01
123456
Manager is now enrolled and activate; to test enter the Manager
ID and combination; the lock should open.
1. Enter Master combination (00 55555) and hold down last digit
of combination until unit double signals and the LED stays on.
2. PRESS 1 (add user).
3. Enter User ID (02-31); lock should beep twice and LED stays on.
4. Enter User ID and combination XXXXXX (example: 02 222222).
5. Re-enter ID XXXXXX
6. The Lock will double signal if the operation was successful, and
triple signal if not accepted.
Repeat the process for each User enrolled.
3750-K
Round Entry

V1.0_0212 | Division of Davcor Group Pty Ltd | www.smartlock.com.au | www.smartlock.co.nz
1. Enter Master combination (00 555555) and hold down last digit
of combination until unit double signals and the LED stays on.
2. PRESS 8.
3. Enter operational mode: (0-7 - corresponding operational
mode from chart below.)
4. Re-enter operational mode (0 – 7) to conrm.
1. Enter Manager combination and hold down last digit of
combination until unit double signals and the LED stays on.
2. PRESS 2. Unit signals twice.
3. Enter User ID (02 to 31). User is temporarily disabled. (User
combination is saved and will be valid if reinstated.)
1. Enter Manager combination and hold down last digit of
combination until unit double signals and the LED stays on.
2. PRESS 3. Unit signals twice.
3. Enter User ID (02 to 31). User is deleted.
1. Enter Manager combination and hold down last digit of
combination until unit double signals and the LED stays on.
2. PRESS 1. Unit signals twice.
3. Enter User ID (02 -31). Unit signals once. User is reinstated. (If
deleted continue with steps 4-6.)
4. Enter User ID and new combination XXXXXX.
(Example: 02 222222.)
5. Re-enter ID XXXXXX.
6. The Lock will double signal if the operation was successful,
and triple signal if not accepted.
1. 1. Enter User ID (00-31) and current combination (example 02
222222) and hold down last digit of combination until unit
double signals and the LED stays on.
2. PRESS 0 (change combination).
3. Enter User ID and new combination XXXXXX.
(Example 02 020202.)
4. Reenter User ID and new combination XXXXX (to conrm).
5. The Lock will double signal if the operation was successful,
and triple signal if not accepted.
1. 1. Enter Manager combination and hold down last digit of
combination until unit double signals and the LED stays on.
2. PRESS 9. Unit signals twice.
3. Enter two-digit Delay period value (00 to 99 minutes) followed
by the two-digit Open period value (00 to 19 minutes).
• Unit will signal twice, if accepted.
• Unit will signal three times, if invalid.
4. Re-enter the Delay and Open period values, to conrm.
• Unit will signal twice and feature is active.
Example: TD override and Silent Alarm
Key press sequence – 00 55555 (hold last) 8, 5, 5
(operation complete).
It is recommended that the Master combination be changed from
the default combination.
1. Enter Master combination (00 555555) and hold down last digit
of combination until unit double signals and the LED stays on.
2. PRESS 0 (change combination).
3. Enter 00 and new combination XXXXXX. (Example 00 654321.)
4. Reenter 00 and new combination XXXXX (to conrm).
5. Lock is now in operational mode, and the only function the
Master can now perform is resetting the lock.
The Master combination must be changed from the initial
combination used during activation in order to enable all the
Manager functions.
1. Enter Manager combination (01 XXXXXX) and hold down last
digit of combination until unit double signals and the LED
stays on.
2. PRESS 0 (change combination).
3. Enter 01 and new combination XXXXXX. (Example 01 111111.)
4. Reenter 01 and new combination XXXXX (to conrm).
5. Lock is now in operational mode, and the only function the
Master can now perform is resetting the lock.
66E
Supra v1.10
To enroll/activate the Manager (Master only)
Exiting Setup Mode
Changing the Master Combination:
Changing the Master Combination:
Mode Option Time Delay Override
(User 31)
Dual Mode Silent Alarm
0
1x
2x
3x x
4x
5x x
6x x
7x x x
NOTE: While the lock is in Setup Mode, only the Master can
perform “Manager Functions” (see Operational Instructions).
Once in Operational Mode, only the Master User can perform
these functions.
NOTE: Entering 0000 will deactivate the Time Delay Feature.
NOTE: If Time Delay is active it may only be deactivated or delay
value decreased in Open Period.
CAUTION: Always perform this operation with the door open, and
test the opening of the Lock with the new combination several
times before closing the door.
WARNING: Once the Master or the Manager changes their
combination then the setup is frozen (Operational Mode). Lock
must be reset either with Master reset or Reset box (p/n 6066) to
change conguration or add Users.
This Function will reset the Lock to pre-setup mode; all Lock settings
and Users are erased. To perform a Master Reset the following two
condition must be met: The Lock must be in Operational Mode
AND the Manager combination must be changed from the initial
combination used to enroll/activate the Manager.
1. Enter Master combination and hold down last digit of
combination until unit double signals and the LED stays on.
2. PRESS 8 (Special Function - Master Reset).
3. Enter Manager combination.
4. Lock will sound one long beep (approx. 2 seconds); the lock is
now in pre-setup mode.
5. PRESS 1 to open the lock.
Example: 00 654321 (hold last); 8, 01 111111 (operation complete)
Master Reset:
OPERATIONAL INSTRUCTIONS
MANAGER FUNCTIONS
Disable User
Delete User
Reinstate User
Change Combination (all users)
Set/Change Time Delay Values

V1.0_0212 | Division of Davcor Group Pty Ltd | www.smartlock.com.au | www.smartlock.co.nz
1. Plug Interface into PC and open LGViewer software on PC.
2. Connect Interface to front of keypad and click safe icon button
on the PC software to begin acquisition.
3. Enter Manager combination and hold down last digit of
combination until unit double signals and the LED stays on.
4. PRESS 7. Unit signals once and Audit will be sent.
5. Disconnect Interface Cable from PC and keypad.
1. Must add at least one (1) user to open lock.
(See Enroll Activate Users.)
• At least one user must be active; all users cannot be disabled
or deleted.
2. If Time Delay is active, one valid combination will start Delay
period.
• Two combinations required to open lock in Open period.
66E
Supra v1.10
Time Delay – Lock Response
Time Delay Override (If feature is enabled)
Silent Alarm (If feature is enabled AND optional Alarm Box is
connected to an alarm system)
Disable Lock
(Optional Alarm Box is connected to an alarm system)
Wrong Try Penalty
Dual Access Mode (If feature is enabled)
Receive Audit
(Manager Only; this function requires Serial Interface [P/N 43087]
and LGViewer Software)
+During the Delay Period the LED will ash every second.
+During the Open Period the LED will ash twice a second, and
the Entry Device will beep every 10 seconds.
+Repeated LED ashing beeping after an opening indicates
that the battery is low and needs immediate replacement. It is
recommended that batteries be replaced at least once a year.
+Uses alkaline battery only. (Example: Duracell™ or Eveready™
alkaline batteries.)
+When the battery level becomes too low to safely operate
the lock any key press will give a low battery warning, and the
battery must be changed before the lock will operate.
If battery is depleted and will not allow lock to open, follow
instructions found in the User Instructions for your keypad.
Lock contains a non-volatile memory; even with batteries
removed the lock will retain all programming.
+Must add User 31. (See Enroll/Activate Users.)
- If User 31 is disabled or deleted, this feature will no longer
function.
+Entry of Override combination during Delay period will open
the lock.
Enter last digit of combination one number higher or one number
lower.
Example: Combination: 01 1-2-3-4-5-6
Duress: 01 1-2-3-4-5-5 or 01 1-2-3-4-5-7
The lock will open without any indication that the duress signal has
been sent.
Alarm Box (2789 or 4002) required. Input signal to the Alarm Box
will disable the lock opening by a valid combination.
Entry of four (4) consecutive invalid combinations starts a ve (5)
minute delay period.
- LED ashes red at ten (10) second intervals.
At the end of the delay period, two more consecutive invalid
combinations will start the ve (5) minute delay period.
During delay period keystrokes will respond with three
signals.
Battery Low Warning
This manual suits for next models
4
Other Davcor Lock manuals