GAS REQUIREMENT
Verify the type of gas supply to be used, either natural or LP, and make sure the marking on the appliance rating
plate agrees with that of the supply. The rating plate is located on the bottom of the outdoor appliance. Never
connect an unregulated gas line to the appliance. You must use the gas regulator provided with the unit even if
the supply is controlled.
An installer-supplied gas shut-off valve must be installed in an easily accessible location. All installer supplied
parts must conform to local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA
70 or the Canadian Electrical Code, CSA C22.1, and the National Fuel Gas Code, ANSI Z223.1 or CAN/CGA-B149.1
Natural Gas Installation Code or CAN/CGA-B149.2 Propane Installation Code.
All pipe sealants must be an approved type and resistant to the actions of LP gases. Never use pipe sealant on
flare fittings. All gas connections should be made by a qualified technician and in accordance with local codes
and ordinances. In the absence of local codes, the installation must comply with the National Fuel Gas Code,
ANSI Z223.1. Gas conversion kits are available from the factory. When ordering gas conversion kits, have the
model number, and the type of gas (natural or LP) from your outdoor appliance.
TOTAL GAS CONSUMPTION OF THE OUTDOOR APPLIANCE WITH ALL BURNERS ON
HI/SEAR:
BFG-30G - 50,000 Btu/hr BFG-30BGD - 49,000 Btu/hr BFG-30BS - 34,000 Btu/hr
The applianceand its individual shut-off valvemust be disconnected from the gas supply piping system during
anypressuretesting of that system at test pressures in excess of 1/2 PSIG (3.5 kPa.) The appliance must be
isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure
testing of the gas supply piping system at test pressures equal to or less than 1/2 PSIG (3.5 kPa.). The installation
of this appliancemust conform with local codes or, in the absence of local codes, with the National Fuel Gas
Code,ANSI Z223.1. Installation in Canada must be in accordancewith the StandardCan1-b149.1 and/or .2
(installation code for gas burning appliances and
equipment) and local codes.
NATURAL GAS HOOK UP: (THIS TYPE OF
CONNECTION SHOULD BE PERFORMED BY A
CERTIFIED OR LICENSED TECHNICIAN ONLY.)
Connection: 1/2" NPT male with 3/8" flareadapter.
Operating pressure: 4.0" W.C. Supply pressure: 5"
to14" water column. If in excess of 14" W.C., a step-
down regulator is required. Check with your local
gas utility company or local codes for instructions on
installing gas supply lines.Be sure to check on type
and size of run, and howdeep toburythe line.If
the gas line is too small, the outdoor appliance will
not function properly. Any joint sealant used must
be an approved type and be resistive to the actions
of natural gases.
TO HOOK-UP THE FITTINGS SUPPLIED
WITH THE OUTDOOR APPLIANCE:
Assemble as shown (Fig. 22). Use threading
compound on male threads only. Donot use
threading compound on the male end of the 1/2”
NPT to 3/8 flare adapter. Use a second pipe wrench
tohold the outdoor applianceinlet pipe toavoid
shifting any internal gas lines of the outdoor
appliance. Ensure that the regulator arrow points in
the direction of gas flow towards the unit, away from the supply. Do not forget to place the installer-supplied
gas valve in an accessible location.