DDS AX User manual

Ambulatory Spinal-Air Decompression Collar
User ManUal
DDs MaX

2
2Table of Contents
Table of Contents
Thank you for choosing DDS
and welcome to an enjoyable life,
free from neck pain.
3 What’s Inside the Box
4 What it is & How it Works
5 Features of the DDS MAX
6 Contraindications & Precautions
7 How to Wear
9 Recommendations for Eective Use
10 How to Wash
11 Warranty
12 Registration & Warranty Card
www.DDSbelt.com

3
What’s Inside the Box
What’s Inside the Box
• Cervical Traction Collar: Velcro Enclosures, Flexible Support Frame,
Support Panel Velcro Enclosures, Extension Hose, Air Valve
• Fixed Chin Collar: Chin Cushion, Collarbone Cushion
• Hand Air Pump
• Instruction Manual
Fixed Chin CollarCervical Traction Collar
Hand Air Pump
User Manual
Important : Read all the instructions and precautions before using the DDS MAX.
Flexible
Support
Frame
Air Injection Nozzle
Extension HoseAir Injection Tongs
Pump Hose
Pump
Handle
Air Injection
Piston
Pressure
Gauge

4
4What it is & How it Works
What it is & How it Works
The DDS MAX is a lightweight and easy to use ambulatory traction collar.
It helps to reduce pressure within the cervical spine using a revolutionary
longitudinal expansion system. The expandable Cervical Traction Collar (rear
section), along with the Fixed Chin Collar (front section), reduces disc pressure
within the cervical spine eectively eliminating pain.
Before Treatment
The herniated or bulging cervical disc, or herniated nucleus
pulposus, applies pressure on the nerve root, ultimately
causing pain.
After Treatment
The DDS MAX alleviates pain and assists active-rehabilitation
by allowing the cervical disc, or nucleus pulposus, back to
its natural position. By increasing the intervertebral space,
pressure applied on the nerve root is relieved, naturally
reducing pain.
Important : Read all the instructions and precautions before using the DDS MAX.

5Features of DDS
Features of the DDS MAX
1The DDS MAX can assist with the following indications:
•Whiplashinjuries(injurieswhichdonotinvolvebreakageordislocationofthebones)
•Job-relatedneckpain,i.e.,prolongedcomputeruse,sewing,etc.
•Sportsinjuries(withoutbreakageordislocation)
•Jointchanges
•DegenerativeChanges(arthritis)
•JointPain/SymptomaticFacetJoint
•MuscleSpasmandGuarding
•PostcompressionFracture
•Nerveimpingement(Subacute-chronicphase)
•Herniateddisc
•NarrowingForamen
•Spondylolisthesis
•Spondylolysis
•CompressionsorRadiculopathies
2 Treatsbulgingand/orherniateddiscseliminatingneckpain.
Bulging and herniated discs are reduced by elongating
the intervertebral spaces in the cervical spine.
3Relaxes muscle spasms, muscle cramps, strain and pain.
4Helps treat degenerative disc disease, spinal stenosis, sciatica
and spondylolysis.
5Helps maintain proper posture.
6Assists individuals with strenuous jobs.
7Is very lightweight and comfortable.
8Is made of highly durable material.
9Simple to use.

6
6
1 DDS MAX should be used under the supervision of a licensed Health
Care Provider.
2 Inate with extreme caution. Do not inate at a rate faster than one pump
in each direction every 5 seconds.
3 Start at a slow pace - inate only to 5 PSI on the rst day, 10 PSI on the
second day, 15 PSI on the third day. Immediately release air to reach a
comfortable PSI level if experiencing any discomfort.
4 Recommended usage is 15 PSI or less depending on your comfort.
Do not exceed 25 PSI.
5 ExtracautionandcaremustbetakenwithpatientswithTMJconcerns.
6 Do not lay down with the device inated.
7 Do not turn your neck either left or right while wearing the device.
8 Consult a physician if the pain increases.
9 Handle with care; dropping the Hand Air Pump can result in malfunction.
10 Shut the Air Valve tightly before machine wash. Water must not enter the
Device. For more information regarding washing DDS proceed to page 10.
Contraindications & Precautions
Precautions
Contraindications
Patients with any of the following health conditions should notify their
physicians before administering DDS:
•highbloodpressure
•cardiovasculardiseases:uncontrolledhypertension,aorticaneurysm,
congestive heart failure
•severecervicalspineinstability
•severeosteoporosis
•cerebrovasculardiseases
•postspineoperationpriortothethirdmonth
•cervicaltumor
•TMJconcerns
Warning: Failure to follow contraindications and precautions may lead to serious
injury and damage to the product.

7
How to Wear
How to Wear
1
2
3
Deate the Cervical Traction Collar
completely by turning the Air Valve
counterclockwise. Upon complete
deation, turn the Air Valve clockwise
until the Valve is fully locked.
Connect the Traction Collar to the
Fixed Chin Collar in order to prepare
positioning on your
neckline.
Position the Fixed Chin Collar so that the chin ts comfortably in the chin groove.
Make sure the device is attached evenly around your neck.
Warning: Keep body in upright position when applying the DDS MAX (sitting or standing).
DO NOT lay down.
Important :
Remembering which numbered line the Primary Velcro Strap adheres to
on the Fixed Chin Collar allows for an easy and consistent application every single time.
The device should be close-tting, secure and comfortable.

8
8How to Wear
4
5
6
Connect Hand Air Pump to the Air
Valve precisely attaching the Air
Injection Tongs with the Air Valve.
Proceed to slowly use the Hand Air Pump to inate the belt.
Inate the bladder at a rate that is no faster than 1 stroke in each direction
every 5 seconds.
Start with a low pressure (5 PSI) on the rst day and gradually increase to 10 PSI on
the second day and then to 15 PSI on the third day. Recommended usage is 15 PSI
or less depending on your comfort.
Wear for 15-30 minutes. You
can adjust the air pressure at
anytime to your comfort level by
momentarily pressing the Air Valve
to release air.
Release pressure to reach
a comfortable PSI level if
experiencing any discomfort.
Removing DDS: You MUST release the air completely out of the device before removal.
You can do so by unscrewing the Air Valve.
Warning:
Do not inate to 15 psi upon rst application. Never exceed 25 psi.

9
Recommendations for Eective Use
Recommendations for Eective Use
1 Inate the bladder slowly and not to excess, starting with a low pressure
on the rst day and gradually increasing the PSI each day until a comfortable
PSI level is reached. If experiencing any discomfort release pressure immediately.
2 Inate the bladder at a slow rate that is no faster than one stroke in each
direction every ve seconds.
3 Recommended usage is 15 PSI or less depending on your comfort.
4 Recommended treatment time is 15-30 minutes daily, 2-3 times a day.
5 Remaining at rest while wearing the DDS MAX will increase the
eectiveness of treatment.
6 Prior to removing the DDS MAX you MUST rst release the air by turning
the air valve counter-clockwise.
7 You may release air anytime while wearing the DDS MAX to increase
comfort by pressing down briey on the air valve stem.
8 The DDS MAX may be worn directly on your skin. If allergies persist,
consult a physician.
9 Apply a hot pack before using DDS MAX to promote muscle relaxation
and to soften disc and soft tissue.
10 Adjust according to your body type. You may obtain greater traction by
adjusting the collar higher or lower on your cervical spine.
11 If further pain persists, seek consultation from your physician.

10
10 How to Wash
How to Wash
1Inate the Cervical Traction Collar to approximately 5 PSI. Make sure that
the Air Valve is tightly shut; water must not enter the Traction Collar.
2Soak the Cervical Traction Collar in water with neutral detergent and
use a soft sponge to wash the Traction Collar.
3Air-dry in the shade.
1Detach the chin and collarbone cushions from the Fixed Chin Collar.
2Soak the cushions along with the Fixed Chin Collar in water and
use a soft sponge with mild detergent to wash.
3Air-dry in the shade.
Important : Do NOT machine wash any portion of the DDS MAX.
To wash the Cervical Traction Collar:
To wash the Fixed Chin Collar:

11
Warranty
Warranty
Limited 1 Year Warranty
DDS, Inc. will repair or replace the unit free of charge for a 1 year period from
the date of purchase. The warranty is covered only if the device is defective in
workmanship or materials.
To obtain service under this warranty, please mail the warranty card at the time
of purchase. You may then return the defective product to the service center on
the warranty card, together with your purchase receipt and $5.00 postage and
handling. In the absence of a purchase receipt, an invoice must to be produced
fromtheseller.Thiswarrantydoesnotapplyforanymisuseand/ordeliberate
mishandling of our products.
Any implied warranty, obligations or liabilities, including but not limited to the
implied warranty of merchantability tness for a particular purpose, shall be
limited in duration to the 1 year duration of this written, limited warranty.
Some states do not allow limitations on how long an implied warranty lasts, so
the limitations may not apply to you.
In no event shall DDS be liable for any special, incidental or consequential
damages for breach of any other warranty, express or implied whatsoever.
Some states do not allow the exclusion and the limitation may not apply to you.
This warranty gives you specic legal rights. These rights may vary according to
your state laws.

12
12 Registration & Warranty Card www.DDSbelt.com
Registration/WarrantyCard
FIRST NAME: MI: LAST:
ADDRESS 1:
ADDRESS 2:
CITY: STATE: ZIP:
PHONE (DAY): (EVENING)
PRODUCT INFORMATION
DATE OF PURCHASE:
DDS MODEL: DDs MaX
HOW DID YOU BECOME AWARE OF DDS?
Mail To Service Center:
DDS, INC.
100 Commerce Way, Suite 5
Hackensack,NJ07601U.S.A.
Table of contents
Other DDS Medical Equipment manuals
Popular Medical Equipment manuals by other brands

Alpinion Medical Systems
Alpinion Medical Systems X-CUBE 70 quick guide

TASKA Prosthetics
TASKA Prosthetics TASKA-XXXXXX Appropriate Use Guidelines

Juzo
Juzo JuzoFlex Patella Xtra Instructions for use

swissflex
swissflex uni 12_75K bridge operating instructions

Rheintechnik
Rheintechnik HK operating instructions

Pari
Pari BOY mobile S Instructions for use