LCD Monitor Quality & Pixel Policy 
During the LCD Monitor manufacturing process, it is not uncommon for one or more pixels to become fixed in an unchanging state. The visible result is a fixed pixel that 
appears as an extremely tiny dark or bright discolored spot.When the pixel remains permanently lit, it is known as a “bright dot.”
When the pixel remains black, it is 
In almost every case, these fixed pixels are hard to see and do not detract from display quality or usability. A display with 1 to 5 fixed pixels is considered normal and 
withincompetitivestandards.Formoreinformation,seeDellSupportsiteat:support.dell.com. 
Maintenance Guidelines 
Caring for Your Monitor 
For best practices, follow the instructions in the list below while unpacking, cleaning, or handling your monitor: 
lTo clean your antistatic screen, slightly dampen a soft, clean cloth with water. If possible, use a special screen-cleaning tissue or solution suitable for the 
antistatic coating. Do not use benzene, thinner, ammonia, abrasive cleaners, or compressed air. 
lUseaslightlydampened,warmclothtocleantheplastics.Avoidusingdetergentofanykindassomedetergentsleaveamilkyfilmontheplastics. 
lIf you notice a white powder when you unpack your monitor, wipe it off with a cloth. This white powder occurs during the shipping of the monitor. 
lHandleyourmonitorwithcareasadarker-colored monitor may scratch and show white scuff marks more than a lighter-coloredmonitor. 
lTo help maintain the best image quality on your monitor, use a dynamically changing screen saver and power off your monitor when not in use. 
 
4.72inches(119.96mm) 
8.66inches(219.92mm) 
6.17inches(156.67mm) 
4.91inches(124.71mm) 
9.84inches(249.94mm) 
6.13inches(155.70mm) 
Weight with stand assembly and cables
Weight without stand assembly 
(For wall mount or VESA mount 
considerations -no cables)
Environmental Characteristics 
The following table lists the environmental conditions for your monitor: 
Dell IN1720 Flat Panel Monitor
Dell IN1920 Flat Panel Monitor
Temperature 
lOperating 
lNon-operating 
0°to40°C(32°to104°F) 
Storage: -20°to60°C(-4°to140°F)
Shipping: -20°to60°C(-4°to140°F)
0°to40°C(32°to104°F) 
Storage: -20°to60°C(-4°to140°F)
Shipping: -20°to60°C(-4°to140°F)
Humidity
lOperating 
lNon-operating 
 
10% to 80% (non-condensing) 
Storage: 5% to 90% (non-
condensing) 
Shipping: 5% to 90% (non-
condensing) 
 
10% to 80% (non-condensing) 
Storage: 5% to 90% (non-
condensing) 
Shipping: 5% to 90% (non-
condensing) 
Altitude
lOperating 
lNon-operating 
3,657.6m (12,000 ft) max 
12,192m (40,000 ft) max 
3,657.6m (12,000 ft) max 
12,192m (40,000 ft) max 
256.08 BTU/hour (maximum) 
119.5 BTU/hour (typical) 
71.82 BTU/hour (maximum) 
64.98 BTU/hour (typical) 
CAUTION: Read and follow the safety instructionsbeforecleaningthemonitor. 