1 Safety
1.1 Information of the AC Storage System
1.1.1 Disclaimer
1.1.2 Target Group
1.2 General Safety
1.2.1 Condition of Use
1.2.2 Symbols
1.2.3 Safety Instructions
1.2.3.1 Handling of Prohibitions
2 Introduction
2.1 About this Manual
2.2 Product Description
2.3 Additional Information
2.4 Product Overview
2.5 LED Indicators
2.6 Push Button (Start up/Shutdown)
3 Installation
3.1 Installation Environment
3.2 Unboxing and Review
3.3 Handle (optional)
3.4 Mechanical Installation
3.5 Assemble DC connectors
3.6 Delta Inverter Connection
3.7 Battery Pack Expansion
3.8 PE Connection
4 Maintenance
5 Error message and Trouble Shooting
6 De-Commissioning
7 Technical Data
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3

Figure 2-1 : The DELTA BX6.3_DD Series have 2 models
Figure 2-2 : Storage system operation illustration
Figure 2-3 : Shipping Components
Figure 2-4 : Dimensions
Figure 2-5 : Overview of interface
Figure 2-6 : Rating labels
Figure 2-7 : LED indicators
Figure 3-1 : Unpack
Figure 3-2 : General handling method
Figure 3-3 : Handling with optional transport handle
Figure 3-4 : Handling with optional transport handle_2
Figure 3-5 : Recommended installation space
Figure 3-6 : Recommended installation space with inverter
Figure 3-7 : Recommended Installation Space of BX6.3_DD + BX6.3_EX100
Figure 3-8 : Insert rawlplug
Figure 3-9 : Install the wiring cover
Figure 3-10 : Inverter Connection
Figure 3-11 : Expanding the Battery Pack with DC(BT+/-) cables
Figure 3-12 : PE Wiring
Figure
12
13
14
15
15
16
17
19
20
21
22
23
24
24
25
26
28
29
30
. . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
Table
Table 2-1 : Packing list
Table 2-2 : Option part of DELTA BX6.3_DD
Table 2-3 : Rating label explanation
Table 2-4 : LED Indicators
Table 2-5 : Push Button
Table 5-1 : Error Message
Table 5-2 : Fault Message
Table 7-1 : Specifications for BX6.3_DD
14
14
16
17
17
32
34
38
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4

Copyright – DELTA ELECTRONICS, INC. - All rights reserved.
This manual accompanies our product for use by the end users. The technical
instructions and illustrations contained in this manual are to be treated as
confidential and no part may be reproduced without the prior written permission
of DELTA ELECTRONICS, INC. Service engineers and end users may not
divulge the information contained herein or use this manual for purpose other
than those strictly connected with correct use of the product. All information and
specifications are subject to change without notice.
DELTA ELECTRONICS, INC. shall have no obligation to both personal injury
and property damage hereinafter with respect to any actions -- (a) the product
has been installed and repaired improperly; (b) the product has been misuse
without following the instructions on this user manual; (c) the product has failed
due to incorrect unpacking.
1 Safety
1.1 Information of the Battery Storage System
1.1.1 Disclaimer
This user manual of the battery storage system is prepared for a person who
is well-trained for installing, commissioning, using, and doing maintenance.
The well-trained person must have the following basic and advanced skills:
•The fundamentals of electricity, wiring, electrical components and electrical
schematic symbols.
• Knowledge of how a battery storage system works and is operated.
•
Training in the installation and commissioning of electrical devices and installations.
• Training in how to deal with the dangers and risks associated with installing
and using electrical devices and installations.
• Compliance with this manual and all safety information.
Please read the user manual before working on the product.
1.1.2 Target Group
Safety
5

1.2 General Safety
- Please read these instructions carefully and keep them for later use.
IMPORTANT SAFETY INSTRUCTIONS : SAVE THESE INSTRUCTIONS !
To prevent any personal injury and any property damage, also ensure long-term
operation of the battery storage system, you must read this section carefully and
review all the safety instructions at all times before using this battery storage system.
This user manual provides important instructions for DELTA BX6.3_DD Battery
storage system. The product is designed, tested, verified, and certified according
to international safety requirements, regulations, and standards but precautions
must be observed when installing and operating the product.
The DELTA BX6.3_DD is a battery storage system designed with two battery
modules. In order to prolong Lithium-based batteries' life, 100% state of charge
(SOC) shown on the device is actually within the range of 95%~100%.
The battery storage system can be charged/discharged from grid, and provides
electricity to household loads and electricity supply backup is available.
The DELTA BX6.3_DD Battery storage system is NOT to be used as a backup
for any medical uses or life supporting uses.
Before battery module running one cycle, it may an error at SOC accuracy.
If DELTA BX6.3_DD has not used for more than six months, please connect
to grid and check the SOC value on display, if the SOC value below 30%,
please select “Charge first mode” to charge BX6.3_DD, it should charge to at
least 30% SOC.
1.2.1 Condition of Use
6
Safety

This section describes the definition of the symbols in this manual.
In order to prevent both personal injury and property damage, and to ensure
long-term operation of the product, please read this section carefully and follow
all the safety instructions while you use the product.
1.2.2 Symbols
DANGER!
- This warning indicates an immediate hazard which will lead to death or serious
injury may occur.
- This warning indicates a possible hazard which may lead to minor injury
may happen.
CAUTION !
WARNING !
- This warning indicates a possible hazard which may lead to death or serious
injury may occur.
- This warning indicates a possible damage to property and the environment
might happen.
ATTENTION
- Additional information is indicated by an exclamation mark enclosed by double
circle. This means the following section contains important information and
user should follow the instruction to prevent any hazards.
INFORMATION
DANGER : ELECTRICAL HAZARD!!
- This warning indicates an immediate electrical hazard which will lead
to death or serious injury may occur.
- Equipment grounding conductor (PE)
- (PE) Équipement conducteur de terre
Safety
7

The battery storage system should not be installed in direct sunlight or on flammable
surfaces. Please be sure to mount the battery storage system tightly on a solid /
smooth surface. The optimal temperature range for the battery storage system to
operate is 10 to 30°C . The operating humidity is within the range from 0 to 95%.
If the ambient temperature is outside the operating range, the battery storage
system stops to protect itself from any unexpected damage.
This battery storage system should be installed by a trained and experienced
installer designated by the retailer. Having the product installed by a non-specialized
installer is very dangerous and can cause damage or injury. The battery storage
system is always installed by 2 or more people. (According to regional regulation,
more people may be required.)
Please make sure any breaker is turned off before connecting cables. Be careful
of the cable length must be less than 100 meters.
1.2.3 Safety Instructions
The battery module contains flammable materials such as organic solvents.
Mishandling the battery module may cause fire, smoke, or an explosion and
the battery module’s functionality will be seriously damaged. Protection circuits
are designed into the battery storage system via BMSS (PCB part inside the
battery cabinet) to protect the battery modules.
Please read and check the following prohibited actions.
1.2.3.1 Handling of Prohibitions
8
Safety

(1) Electrical Shock
Do not touch the terminals of the battery module without protectors.
Be grounded with the specified conditions.
High voltage may occur between the positive and the negative terminals.
Electric shock impairs health or may cause threat to life.
More than 2,000 meters higher, risks of an electric shock will be increased.
(2) Immersion
Do not immerse the battery module in liquid such as water, beverages, or
other fluids.
Do not expose to corrosive substances such as sea breeze, steam or chemicals.
Do not install in the humid places or places to condensation.
Exposure to liquid may damage the battery module or the circuit board.
This may cause a battery module's damage to leak electrolyte, generate
heat, smoke, catch fire, or explode.
(3) High Temperature
Do not use or place the battery module near an open flame, heater or high
temperature. Subjecting the battery module to high temperature may damage
the separator and cause internal short circuit.
This may cause the battery module's damage to leak electrolyte, generate heat,
smoke, catch fire, or explode.
(4) Charge Conditions
Only charge the battery module within the specified conditions.
(e.g., temperature range, voltage, current and etc.)
Charging with unspecified conditions (e.g., over charge or abnormal current)
may cause the battery module's damage to leak electrolyte, generate heat,
smoke, catch fire,or explode.
(5) Reverse Polarity
Check the positive (+) and the negative (-) terminals.
If the battery module is connected with a reversed polarity, unexpected
reactions may occur.
This may cause the battery module's damage to leak electrolyte, generate
heat, smoke, catch fire, or explode.
DANGER!
- This warning indicates an immediate hazard which will lead to death or serious
injury may occur.
9
Safety

(6) Direct Connection
Do not connect the battery module to AC power or unspecified DC power.
This may cause the battery module's damage to leak electrolyte, generate
heat, smoke, catch fire, or explode.
(7) Use in Other Equipment
Do not use the battery module for any other purposes or connecting
unspecified equipment.
If the battery module is used with unapproved applications or systems, the
battery module may be damaged, leak electrolyte, generate heat, smoke,
catch fire, or explode.
(8) Incineration and Heat
Keep the battery module away from heat and fire.
Heating the battery module and may cause it to be damaged, leak electrolyte,
generate heat, smoke, catch fire, or explode.
(9) Short-Circuit
Do not connect between the positive (+) and the negative (-) terminals with
a conductive material (e.g., wire, a cable, etc.).
Do not carry or store the battery module with metal objects.
If the battery module is shorted, the battery module may be overheated.
This may cause the battery module's damage to leak electrolyte, generate
heat, smoke, catch fire, or explode.
(10) Disassembly
Do not disassemble or modify the battery module.
Disassembly or modification of the battery module may damage the
protection circuit.
This may cause the battery module's damage to leak electrolyte, generate
heat, smoke, catch fire, or explode.
(11) Charge in High Temperatures
Do not charge the battery module in high temperature environment.
If the battery module is charged with exposing high temperature, the battery
module’s protection circuit may be activated and stop or fail the charging.
This may cause the battery module's damage to leak electrolyte, generate
heat, smoke, catch fire, or explode.
10
Safety

WARNING !
- This warning indicates a possible hazard which may lead to death or serious
injury may occur.
(1) Magnetism
Do not place the battery module near strong magnetism. (e.g., electromagnetic
cooker, etc. )
This may cause the battery module's damage to leak electrolyte, generate
heat, smoke, catch fire, or explode.
(2) Mixed Use
Do not mix with other batteries.
The battery module should not be used with other batteries having a different
capacity, chemistry, manufacturing date or manufacturer.
This could cause the battery module's damage to leak electrolyte, generate
heat, smoke, catch fire, or explode.
- This warning indicates a possible hazard which may lead to minor injury
may happen.
CAUTION !
(1) Exposure to Direct Sunlight
Do not use or leave the battery module in a location exposed to excessive
heat, such as in direct sunlight or in a car. It could cause the battery module's
damage to leak electrolyte, generate heat, smoke, catch fire, or explode.
It may also cause the battery's performance and life to deteriorate.
(2) Charging Temperature Range
Only charge the battery module within operating temperature range.
Charging outside of this temperature range could cause the battery module's
damage to leak electrolyte, generate heat.
It may also cause the battery module's performance and life to deteriorate.
(3) Manual
Please read the system manual before use.
Keep the system manual for future reference.
(4) Recycling
When disposing of the battery module, recycle it according to local rules
and regulations.
11
Safety

The user manual is valid for the following device types :
• DELTA BX6.3_DD
• DELTA BX6.3_DD + BX6.3_EX100
The DELTA BX6.3_DD Series have 2 models as shown in Figure 2-1.
Delta reserves
the right to make modifications to the content and technical
data in this user manual without prior notice.
2 Introduction
2.1 About this Manual
Figure 2-1 : The DELTA BX6.3_DD Series have 2 models
BX6.3_DD BX6.3_DD + BX6.3_EX100
This device is battery system with following features:
• Monitoring of battery system functions and performance achieved by inverter
monitoring
• Integrated energy management system
• Integrated charger controller
• Transformer-less
The system diagram of BX6.3_DD is shown as Figure 2-2.
Delta’s BX6.3/BX6.3_DD + BX6.3_EX100 series with high reliability Li-ion battery
is a home energy storage solution with 6.3/12.6 kWh capacity. It can be integrated
with home PV system and can be scalable up to 12kWh for future expansion.
With BX6.3/BX6.3_DD + BX6.3_EX100, house owner can maximize the efficiency
of home energy management by saving and managing excess solar energy from
home PV system. Besides, it can be considered as the backup power during
emergency or suffering a power outage.
2.2 Product Description
12
Introduction

Figure 2-2 : Storage system operation illustration
MyDeltaSolar (Admin)
Solar Panel Grid
3rd Party
Monitoring Plaform
INV
BX6.3_DD
Distribution Panel
BX6.3_EX100
Critical Load
DC
DC
DC
AC
CT
LAN
EthernetP2P
MyDeltaSolar Cloud Service (Monitoring)
Cloud
CT
Load
MicrowaveRice
Cooker
IHWashing
Machine
* Only one communication protocol (LAN, Ethernet, Wi-Fi) can be
used at the same time.
*For AU
market
Production: Feed-in:
Consumption: Purchased:
3 kW 1 kW
2 kW 0 kW
More details or related product information, please visit: http://www.deltaww.com
2.3 Additional Information
DC1
Data
Collector
LightTVRefrigeratorChargeing
Introduction
13

2.4 Product Overview
The shipping components of DELTA BX6.3_DD are shown as Figure 2-3.
Object Qty Description
1 Delta BX6.3_DD
Handle
1
1
1
Residential DC ESS
Inverter lifting handle
5 Plastic cover 4
6 H4 Wrench 2 To disconnect H4 connector
7 H4 Connector 2 pair Connector for inverter
9 Japanese Manual 2 User manual and Quick install guide in Japanese
Wiring Cover 1
Protective cover to prevent users from touching the power cable
8
2Quick Installation Guide
(English)
The Instruction to provide the information of safety,
Installation and specification.
3Communication
connector Connector for inverter communication board
4 Rubber cover 1 Protective cover for non-critical waterproof and dust prevent
Table 2-1 : Packing list
Figure 2-3 : Shipping Components
Table 2-2 : Option part of DELTA BX6.3_DD
Object Exterior Description
Option part
14
Introduction
①
②
⑧⑦⑥
③
⑨
④ ⑤

Figure 2-4 : Dimensions
unit: mm
Figure 2-5 : Overview of interface
Figure 2-4 shows the dimensions of DELTA BX6.3_DD.
Figure 2-5 shows the details of interface.
570
50
840
250
BT+
BT-
Inverter Bus+
Inverter Bus-
Push button
Inverter Comm.
Ex Comm.
It is prohibited to open the front door.
It may cause failure.
The warranty is void once the door is
opened.
15
Introduction

Please refer to Figure 2-6 for the location of product label. You can identify the
model number and the specifications by the information on the product label.
The table (Table 2-3) along with these labels explains the definition of the specific
mark.
Figure 2-6 : Rating labels
Symbol Definition
Before working with the Battery Pack, you must read the supplied
manual and follow the instructions contained therein.
The housing of the Battery Pack must be grounded if this is required
by local regulations.
WEEE marking
The Battery Pack must not be disposed of as standard household waste,
but in accordance with the applicable electronic waste disposal regulations
of your country or region.
Table 2-3 : Rating label explanation
16
Introduction

The DELTA BX6.3_DD has three different color LED notification on the front
cover of the case that signal various system statuses:
2.5 LED Indicators
Use Push button to turn ON/OFF the unit, or start-up inverter with system AC supply.
2.6 Push Button (Start up/Shutdown)
Figure 2-7 : LED indicators
Table 2-4 : LED Indicators
Table 2-5 : Push Button
Definition
Standby mode
Charge
Discharge
Boot up / Shut down
BMS error
LED Status
GREEN FLASH
ORANGE ON
GREEN ON
RED FLASH
RED ON
ProgrammingRED & GREEN FLASH AlTERNATELY
Status Operation Action
BX6.3_DD power OFF Power button push > 20 sec
(until grid green LED flash)
Power ON the unit
(Cold start-up)
BX6.3_DD power ON already Power button push >1 sec Power OFF the unit
Operating
* For Australia, make sure the external isolator has been turned on before starting up the
system and has been turned off when shutting down the system.
17
Introduction

The chapter contains instructions for (1) Installation environment
(2) Mechanical installation; (3) Electrical Installation; (4) Communication setup.
3 Installation
WARNING !
- Do not install BX6.3_DD near or on flammable surfaces.
- Please mount BX6.3_DD tightly on a solid / smooth surface.
- Install BX6.3_DD in a location that prevents damage from flooding.
- Do not expose BX6.3_DD to ambient temperatures above 60°C or below -10°C.
- Operating or storing BX6.3_DD in temperatures outside its specified range might
cause damage to BX6.3_DD.
- The optimal temperature range for BX6.3_DD to operate is -10° to 45°C.
- If the ambient temperature is outside the optimal operating range, BX6.3_DD
will be de-rating.
- The operating humidity is within the range from 0 to 95%.
- BX6.3_DD may limit charge or discharge power based on battery cell temperature
to improve battery lifespan.
- If the ambient temperature is outside the operating range, BX6.3_DD stops to
protect itself from any unexpected damage.
CAUTION !
3.1 Installation Environment
BX6.3_DD is designed to be waterproof and can be installed both indoors and
outdoors. However, please avoid exposure to direct sunlight, high temperature
and high humidity if installed outdoors.
Please avoid using in the following condition; otherwise the device may malfunction.
• Locations where IP65 isn't satisfied.
• Locations where temperature changes severely.
• Locations where the device is directly exposed to saltwater, sea breezes and
high humidity.
• Locations that are or might be affected by explosive, combustible, corrosive
and other poisonous gases.
• Location exposed dust and dirt.
• Location with poor ventilation.
• Locations with other special conditions.
• At altitude above 2000m.
18
Installation

3.2 Unboxing and Review
The unpacking procedure of BX6.3_DD is shown as
Figure 3-1
.
Figure 3-1 : Unpack
Require two or more persons
to move the battery inverter.
There is an optional handle to
easily stand up BX6.3, please
see section 3.3 for detail.
①
②
③③
19
Installation

Handle position
Prohibit to force with the
cabling area.
Require two or more persons
to move the battery inverter.
Figure 3-2 : General handling method
Cabling area
20
Installation
Other manuals for BX6.3 DD
1
Table of contents
Other Delta Storage manuals
Popular Storage manuals by other brands

AA Products
AA Products SH-4603-GAP instruction manual

Toolland
Toolland BG57000 user manual

ATTO Technology
ATTO Technology FastStream SC 7500 Technical specification

HP
HP P9000 user guide

Sun Microsystems
Sun Microsystems StorEdge 6920 System Regulatory and safety information

CRU Dataport
CRU Dataport RTX 100-3Q quick start guide

Maxtor
Maxtor OneTouch III C01W010 Specifications

BLUM
BLUM TANDEMBOX intivo Assembly instruction

Western Digital
Western Digital WDBAAH0015HCH - My Book Elite quick start

Buffalo
Buffalo HDW-PDU3 MiniStation Air Specifications

HP
HP StorageWorks XP10000 - Disk Array Configuration guide

Intenso
Intenso 2 operating instructions