Delta DOP-B07 Series User manual

DOP
-B07
High Color Wide Screen
User-Friendly HMI Products
B07S(E)415 / B07S(E)515 / B07PS415 / B07PS515 Instrunction Sheet
(1) Preface
Thank you for purchasing DELTA’s DOP-B series. This instruction sheet will be helpful in the installation, wiring and inspection of
Delta HMI. Before using the product, please read this instruction sheet to ensure correct use. You should thoroughly understand all
safety precautions before proceeding with the installation, wiring and operation. Place this instruction sheet in a safe location for
future reference. Please observe the following precautions:
Install the product in a clean and dry location free from corrosive and inflammable gases or liquids.
Ensure that all wiring instructions and recommendations are followed.
Ensure that HMI is correctly connected to a ground. The grounding method must comply with the electrical standard of
the country (Please refer to NFPA70: National Electrical Code, 2005 Ed.).
Do not disassemble HMI, modify or remove wiring when power is applied to HMI.
Do not touch the power supply during operation. Otherwise, it may cause electric shock.
If you have any questions during operation, please contact our local distributors or Delta sales representatives.
The content of this instruction sheet may be revised without prior notice. Please consult our distributors or download the most
updated version at http://www.delta.com.tw/ia
(2) Safety Precautions
Carefully note and observe the following safety precautions when receiving, inspecting, installing, operating,
maintaining and troubleshooting. The following words, DANGER, WARNING and STOP are used to mark safety
precautions when using the Delta’s HMI product. Failure to observe these precautions may void the warranty!
Installation
Comply with quick start for installation. Otherwise it may cause equipment damage.
Do not install the product in a location that is outside the stated specification for the HMI.
Failure to observe this caution may result in electric shock, fire, or explosion.
Do not install the product in a location where temperatures will exceed specification for
the HMI. Failure to observe this caution may result in abnormal operation or damage the
product.
Please note that this equipment has obtained EMC registration for commercial use. In the
event that it has been mistakenly sold or purchased, please exchange it for equipment
certified for home use.
Do not use this product as an alarm device for disaster early warning that may result in
personal injury, equipment damage, or system emergency stop.
Wiring
Connect the ground terminals to a class- 3 ground (Ground resistance should not exceed
100 ). Improper grounding may result in communication error, electric shock or fire.
Operation
The users should use Delta Screen Editor software to perform editing in Delta's HMI
product. To perform editing and confirming HMI programs without using Delta Screen
Editor software in Delta's HMI product may result in abnormal operation.
To prevent the personal injury and equipment damage, when designing HMI programs,
please ensure that a communication error occurred between Delta’s HMI product and the
connecting controller or equipment will not result in system failure or malfunction.
Please be sure to backup the screen data and HMI programs in case they are lost,
accidentally deleted or worse.
Do not modify wiring during operation. Otherwise it may result in electric shock or
personal injury.
Never use a hard or pointed object to hit or strike the screen as doing this may damage the
screen and let the screen has not respond at all, and then cause HMI to work abnormally.
Maintenance and Inspection
Do not touch any internal or exposed parts of the HMI as electrical shock may result.
Do not remove operation panel while power is on. Otherwise electrical shock may result.
Wait at least 10 minutes after power has been removed before touching any HMI terminals
or performing any wiring and/or inspection as an electrical charge may still remain in the
HMI with hazardous voltages even after power has been removed.
Turn the power off before changing backup battery and check system settings after
finishing change. (all data will be cleared after changing battery).
Be sure the ventilation holes are not obstructed during operation. Otherwise malfunction
may result due to bad ventilation or overheatin
g
troubles.
Wiring Method
Do not use a voltage that will exceed specification for the HMI. Failure to observe this
caution may result in electric shock or fire.
Remove the terminal block from the HMI before wiring.
Insert only one wire into one terminal on the terminal block.
If the wiring is in error, perform the wiring again with proper tools. Never use force to
remove the terminals or wires. Otherwise, it may result in malfunction or damage.
For the power line that forced to take out, ensure to check wiring again and restart.
Communication Wiring
Comply with communication wiring specification for wiring.
Wiring length should comply with the stated specification for the HMI.
Proper grounding to avoid bad communication quality.
To avoid noise and interference, the communication cable, all power cables, and motor
power cable should be placed in separate conduits.
(3) Pin Definition of Serial Communication
DOP-B07S(E)415 DOP-B07PS415 Series
COM1 Port (Supports Flow Control)
COM Port PIN Contact
RS- 232
1
2 RXD
3 TXD
4
5 GND
6
7 RTS
8 CTS
9
Note: Blank = No Connection.
COM2 Port (Supports Flow Control)
COM Port PIN MODE1 MODE2 MODE3
RS- 232 RS- 422 RS- 485
1 TXD+ D+
2 RXD
3 TXD
4 RXD+
5 GND GND GND
6 TXD- D-
7 RTS
8 CTS
9 RXD-
Note1: Blank = No Connection.
Note2: When COM2 port is used for RS- 232 flow control, i.e. RTS and CTS signals are used for flow control, COM3 port will
become incapable of being used.
Note3: When COM2 port is used for RS- 422 flow control, please refer to the following COM3 Port signals table for pin
assignments. The signals, RTS+ , CTS+ , RTS- and CTS- shown in brackets are the signals used for flow control.
COM3 Port
COM Port PIN MODE1 MODE2 MODE3
RS- 232 RS- 422 RS- 485
1 TXD+ (RTS+ ) D+
2 RXD
3 TXD
4 RXD+ (CTS+ )
5 GND GND GND
6 TXD- (RTS- ) D-
7
8
9 RXD- (CTS- )
Note1: Blank = No Connection.
Note2: When COM2 port is used for RS- 422 flow control, please refer to the COM3 Port signals table above for pin assignments.
The signals, RTS+ , CTS+ , RTS- and CTS- shown in brackets are the signals used for flow control.
DOP-B07S(E)515 DOP-B07PS515 Series
COM1 Port (Supports Flow Control)
COM Port PIN Contact
RS- 232
1
2 RXD
3 TXD
4
5 GND
6
7 RTS
8 CTS
9
Note: Blank = No Connection.
COM2 and COM3 Port
COM Port PIN
MODE1 MODE2 MODE3
COM2 COM3 COM2 COM3 COM2 COM3
RS- 232 RS- 485 RS- 485 RS- 485 RS- 232 RS- 422
1 D+ TXD+
2 RXD RXD
3 TXD TXD
4 D+ D+ RXD+
5 GND GND GND
6 D- TXD-
7
8
9 D- D- RXD-
Note1: Blank = No Connection.
Note2: B05S111 / B07S(E)515/ B07PS515 series models do not support RS- 422 flow control function.
Note3: COM3 is the extension port (COM2 and COM3 share one physical port).
DOP- B07E415 / DOP- B07E515 Ethernet Interface (LAN)
Ethernet Interface (LAN) PIN Contact
Ethernet
1 TX+
2 TX-
3 RX+
4
5
6 RX-
7
8
Note: Blank = No Connection.
(4) Parts Names
DOP- B07S(E)415 DOP- B07PS415 (Front View)
A : Power LED Indicator
Lights in green when HMI works normally.
C
: Operation LED Indicator (Blue) (Note1)
The operation LED indicator blinks in blue when either the communication is carried out or
the data is accessing (please refer to the “Note1” below for explanation).
: Alarm LED Indicator (Red)
The alarm LED indicator blinks in red when one of the alarms is on.
D Touch Screen / Display
NOTE
1. The definition of the operation LED indicator (Blue) can be determined by the users freely.
DOP- B07S(E)415 DOP- B07PS415 (Rear View)
A Power Input Terminal F Ethernet Interface (LAN)
B
COM3
(It is provided with two LED indicators to
indicate that HMI is in Read or Write status
during the communication process.)
G USB Host
C
COM2
(It is provided with two LED indicators to
indicate that HMI is in Read or Write status
during the communication process.)
H Audio Output Interface
D COM1 I Memory Card Slot / Battery
E USB Slave - -
A
C
B
G
D
C
B
A
I
E
F
H
PIN1
PIN1
PIN1
PIN1
PIN1

DOP- B07S(E)515 DOP- B07PS515 (Front View)
A Power LED Indicator (Lights in green when HMI works normally.)
B Touch Screen / Display
DOP- B07S(E)515 DOP- B07PS515 (Rear View)
A Power Input Terminal F USB Slave
B COM2 (can be extended to COM3
(Note1)
) G System Key
C COM1 H Ethernet Interface (LAN)
D Memory Card Slot / Battery Cover I Audio Output Interface
E USB Host - -
NOTE
1. For the setting method, please refer to the pin definition of serial communication.
(5) Dimensions
DOP- B07S(E)415 DOP- B07PS415
DOP- B07S(E)515 DOP- B07PS515
184(7.24")
144(5.67")
+1.0
172.4
0
T
+1.0
132.4
0
(5.21" )
Note:
T=1.6mm(0.063")~
6mm(0.24")
+0.04"
(6.79" )
0
+0.004"
0
43(1.69")
131(5.16")
(6) Specifications
MODEL DOP-B07
S415 DOP-B07
E415 DOP-B07
PS415 DOP-B07
S515 DOP-B07
E515 DOP-B07
PS515
LCD MODULE
Display Type 7” Widescreen TFT LCD
(65536 colors) 7” TFT LCD
(65536 colors)
Resolution 800 x 480 pixels 800 x 600 pixels
Backlight LED Back Light (less than 20,000 hours
hal
f
-lifeat25
oC)
(Note 1)
LED Back Light (less than 10,000 hours
hal
f
-lifeat25
oC)
(Note 1)
Display Size 152.4 x 91.44mm 141 x 105.75mm
Operation System Delta Real Time OS
MCU 32-bit RISC Micro-controller
NOR Flash ROM Flash ROM 128 MB
(OS System: 30MB / Backup: 16MB / User Application:82MB)
SDRAM 64Mbytes
Backup Memory 16Mbytes
Sound
Effect
Output
Buzzer Multi-Tone Frequency 2K ~ 4K Hz 85dB
AUX N/A Stereo output N/A N/A Stereo output N/A
Ethernet Interface N/A
IEEE 802.3,
IEEE 802.3u
N/A N/A
IEEE 802.3,
IEEE 802.3u
N/A
10/100
Mbps
auto- sensin
g (has
built- in
isolated
power
circuit
(Note
3)
10/100 Mbps
auto- sensing
(has built- in
isolated
power circuit
(Note 3)
USB 1 USB Host
(Note 2)
Ver 1.1 /
1 USB Slave Ver 2.0
Memory Card SD Card (supports SDHC)
Serial
COM
Port
COM1 RS- 232 (supports hardware flow control)
COM2 RS-232
RS-422
RS-485
RS-232
RS-422
RS-485
(has built- in
isolated
power circuit
(Note 3)
RS-232
RS-422
RS-485
RS-232
RS-485
RS- 232 /
RS- 485
(has built- in
isolated
power circuit
(Note 3)
)
RS-232
RS-485
COM3 RS-232
RS-422
RS-485
RS-232
RS-422
RS-485
(has built- in
isolated
power circuit
(Note 3)
RS-232
RS-422
RS-485
RS-422
RS-485
RS- 422 /
RS- 485
(has built- in
isolated
power circuit
(Note 3)
)
RS-422
RS-485
Function Key N/A
Perpetual Calendar
(RTC) Built- in
Cooling Method Natural air circulation
Safety Approval CE UL
(Note 4)
KCC
(Note 4)
Waterproof Degree IP65 NEMA4
Operation Voltage
(Note 5)
DC +24V
-10% ~
+15%
(please use
isolated
power
supply)
DC +24V
-10% ~
+15%
has
built- in
isolated
power circuit
(Note 3)
DC +24V
-10% ~
+15%
(please use
isolated
power
supply)
DC + 24V
(- 10% ~
+ 15%)
(please use
isolated
power
supply)
DC + 24V
(- 10% ~
+ 15%)
(has built- in
isolated
power circuit
(Note 3)
)
DC + 24V
(- 10% ~
+ 15%)
(please use
isolated
power
supply)
Voltage Endurance AC500V for 1 minute (between charging (DC24V terminal) and FG terminals)
Power Consumption
(Note 5)
5W 7.5W 5W 7.68W
Backup Battery 3V lithium battery CR2032 x 1
Backup Battery Life It depends on the temperature used and the conditions of usage,
about 3 years or more at 25oC.
Operation Temp. 0
o
C ~ 50
o
C
Storage Temp. -20
o
C ~ +60
o
C
Ambient Humidity 10% ~ 90% RH [0 ~ 40oC], 10% ~ 55% RH [41 ~ 50oC]
Pollution Degree 2
Vibration IEC 61131- 2 compliant 5Hz f8.3Hz = Continuous: 3.5mm, 8.3Hz f150Hz =
Continuous: 1.0g
Shock IEC 60068- 2- 27 compliant 15g peak for 11 ms duration, X, Y, Z directions for 6 times
Dimensions
(W) x (H) x (D) mm 215 x 161 x 50 184 x 144 x 50
Panel Cutout
(W) x (H) mm 196.9 x 142.9 172.4 x 132.4
Weight Approx.970g Approx.800g
NOTE
1) The half- life of backlight is defined as original luminance being reduced by 50% when the maximum driving current is
supplied to HMI. The life of LED backlight shown here is an estimated value under 25oC normal temperature and humidity
conditions.
2) USB Host port can provide up to 5V/ 500mA of power.
3) The withstand voltage of the isolated power circuit is 1500V peak for 1 minute.
4) Some models are in the process of application to UL and KCC certification. For more information, please consult our
distributors.
5) The value of the power consumption indicates the electrical power consumed by HMI only without connecting to any
peripheral devices. In order to ensure the normal operation, it is recommended to use a power supply which the capacity is
1.5 ~2 times the value of the power consumption.
6) The content of this quick start may be revised without prior notice. Please consult our distributors or download the most
updated version at
http://www.delta.com.tw/ia/
.
A
B
C
B
A
F
G
E
H
I
D
Units mm (inches)
Units mm (inches)
This manual suits for next models
6
Other Delta Touch Terminal manuals
Popular Touch Terminal manuals by other brands

Partner
Partner SP-26 Series quick start guide

Siemens
Siemens 3UF1900-1KA00 operating instructions

Wincor Nixdorf
Wincor Nixdorf Beetle /i8A operating manual

Alcatel
Alcatel OmniPCX Enterprise Easy Reflexes user guide

CTC Union
CTC Union CT142 Series product manual

Lear Siegler
Lear Siegler ADM 5 Maintenance manual