1. PARTS:
A. Blend Center assembly B. 1 pc. 8’ long vinyl supply tubing with foot valve
C. 1 pc. Ceramic weight 1/4” ID, Model 633MB2; 3/8” ID, Model 633MB
D. 3 pcs. ea. #8x1-1/2” screws and anchors E. 1 pc. label card
F. Metering tip kit G. 1 pc. 1/4” NPT Garden Hose bushing
H. 1 pc. Hose clamp I. Ball Valve (633MB2 only)
2. INSTALLATION:
This product is designed only to be used as described in this instruction sheet. Adhere to all warnings and
cautions identified in this document.

WARNING: Installations must conform to all local and national plumbing codes and use
approved backflow prevention and pressure relief devices where required.
ALWAYS DISCONNECT DISPENSER FROM WATER SOURCE WHEN DISPENSER
IS NOT IN USE.

Always read SDS for all chemicals used and follow personal protective guidelines.
A) Mounting and Water Supply:
Remove the two cover retainer screws and the cover from the blend center assembly. Hold the unit to the wall and locate the
positions for the mounting screws. Mount the unit to the wall using 2 mounting screws and anchors, and replace the covers
and screws.
The water inlet is equipped with a female garden hose fitting (with strainer washer) for attaching a water supply hose. The
unit is designed so water can be supplied to either side by interchanging the pipe plug and the female hose fitting. Note:
Apply pipe dope, hand-tighten, and then turn 1-1/2 times with a wrench.
DO NOT OVERTIGHTEN.
B) Chemical Injection Adjustment:
WARNING: USE CARE WHEN HANDLING HAZARDOUS CHEMICALS.
Chemical feed rates are controlled by a metering tip screwed into the injector barb. Select a tip for the barb using Table 1 as
a guide.
633MB2 only: Screw ball valve onto inlet of injector.
C) Chemical Supply:
Place the chemical container in a convenient location not more than 6 feet below the blend center (greater lifts will reduce
injection capacity). Slip ceramic weight over tubing and insert the end with the foot valve into the chemical container. Cut
the tubing to any convenient length that will allow it to extend from the bottom of the chemical container to the injector inlet
barb (See figure 1). Gummed labels are provided for labeling chemicals.
D) Outlet:
Screw outlet hose (not provided) onto outlet of injector using the bushing. Squeeze hose clamp around hose. Locate
position for mounting screw and mount hose clamp to wall using remaining screw and anchor.
3. OPERATION:
The blend center is now ready for use. Depressing the push button opens the valve, allowing water to flow through the chemical
injector that mixes chemical at the desired rate. The button is spring loaded to prevent accidental overflow if unattended, but may
be converted to a locking button by cutting off the tab at the notch (See Figure 2). Pushing the button and turning it 1/4 turn
clockwise at the end of its travel allows the valve to lock on. This makes it unnecessary for the attendant to hold the button in
while filling large containers. Turning the button in a counterclockwise direction will release it, allowing the valve to shut off.
CAUTION: WHEN SERVICING UNIT BE SURE THAT REPLACEMENT PARTS HAVE BEEN INSTALLED
ACCORDING TO DRAWING. BE CERTAIN CHECK VALVE PARTS ARE IN PLACE.
4. SERVICING: CAUTION: TURN OFF WATER SUPPLY BEFORE SERVICING.
A. If unit fails to draw chemical. 1. Is the hose too long? (See Table 2)
2. Is the metering tip blocked? Remove tip and clear blockage. 3. Is the hose kinked or otherwise obstructed?
DEMA BLEND CENTER
MODELS 633MB, 633MB2
I-606 Pg. 2 of 4
Rev. B-36300 11/23/10
B. If unit stops drawing chemical. 1. Is the foot strainer clogged? Lift from drum and clean.
2. Is the metering tip blocked? Remove and clean. 3. Is the injector check valve clogged? Remove square,
plastic metering knob to inspect check valve ball, spring and O-ring.
C. Injector continues to draw chemical after water valve closes: Chemical supply is higher than bottom of discharge hose
creating a natural siphon. Lower the supply vessel or hang up outlet hose after use.
D. Valve Malfunction:
Check that the button moves freely up and down and that a “click” can be heard when the button is pushed and released,
indicating that the magnet is activating the plunger properly. Remove cover. To inspect internal parts, unscrew magnet
housing and carefully pull off the enclosing tube so as not to drop the plunger, kick-off spring and spacer. Check for dirt or
damage impeding plunger and kick-off spring movement. Inspect the diaphragm, making sure the two small pin holes (bleed
holes) in the diaphragm convolution are clear to allow the valve to close.
TABLE 1
Tip Color 1 cps 75 cps 200 cps
Oz/Gal Ratio Oz/Gal Ratio Oz/Gal Ratio
Clear 0.89 143 0.39 326 0.23 553
Purple 1.18 109 0.57 225 0.44 293
Yellow 1.93 66 1.17 109 0.88 145
Green 3.17 40 2.26 57 1.79 72
Pink 4.19 31 2.96 43 2.21 58
Turquoise 6.51 20 4.77 27 3.63 35
Black 7.14 18 5.85 22 4.49 29
Gray 9.28 14 7.27 18 5.47 23
Red 12.71 10 9.19 14 6.45 20
Blue 13.96 9 10.31 12 7.11 18
Brown 17.32 7 12.61 10 7.97 16
White 20.34 6 14.31 9 8.61 15
Orange 21.04 5 15.32 8 8.95 14
No Tip 23.94 4 17.02 7 10.61 12
TABLE 2
Hose I.D. 3/8" 1/2" 5/8"
Max. Length 15 ft. 50 ft. 100 ft.
RETURNS: NO MERCHANDISE MAY BE RETURNED FOR CREDIT WITHOUT DEMA’S WRITTEN
PERMISSION. RETURN MERCHANDISE AUTHORIZATION NUMBER REQUIRED IN
ADVANCE OF RETURN.
WARRANTY: DEMA products are warranted against defective material and workmanship under normal use and service
for one year from the date of manufacture. This limited warranty does not apply to any products which
have a normal life shorter than one year or failure and damage caused by chemicals, corrosion, improper
voltage supply, physical abuse, or misapplication. Rubber and synthetic rubber parts such as “o”- rings,
diaphragms, squeeze tubing and gaskets are considered expendable and are not covered under warranty.
This warranty is extended only to the original buyer of DEMA products. If products are altered or repaired
without prior approval of DEMA, this warranty will be void.
Defective units or parts should be returned to the factory with transportation prepaid. If inspection shows
them to be defective, they will be repaired or replaced without charge, F.O.B. factory. DEMA assumes no
liability for damages. Return merchandise authorization number, to return units for repair or replacement,
must be granted in advance of return.
DEMA BLEND CENTER
MODELS 633MB, 633MB2
I-606 Pg. 3 of 4
Rev. B-36300 11/23/10
BUSHING
UTILITY KNIFE
FIGURE 1
CHEMICAL CONTAINER
WEIGHT
FOOT VALVE
CERAMIC
PUSH BUTTON
HOSE CLAMP
PUSH BUTTON ACTUATOR
PIPE PLUG
SUPPLY TUBE
TO CHEMICAL
METERING TIP
BALL VALVE
(633MB2 ONLY)
STRAINER WASHER
INLET HOSE ADAPTOR
DEMA BLEND CENTER
MODELS 633MB, 633MB2
I-606 Pg. 4 of 4
Rev. B-36300 11/23/10
17
21
22
29 30
31
32
14
27 28 26
15
18
23
20
19
12
13 16
11
24 25
(SPECIFY COLOR)
69
10
8
7
4
5
3
(SPECIFY COLOR)
2
1
NO. PART NO. DESCRIPTION NO
. PART NO. DESCRIPTION
1 66-139 Magnet Housing (Specify Color) 19 24-24P Check Valve Ball
2 66-140 Push Button (Specify Color) 20 24-23 Check Valve Spring
3 63-53 Magnet 21 24-34-7 Check Valve Core
4 63-36 Spring 22 25-29 Metering Knob O-Ring
5 41-7-25 Enclosing Tube 23 24-68 Injector Body (P203C Series)
6 63-87 Valve Repair Kit 24 P203CTC-LB Injector (633MB)
7 63-37 Spacer 25 P203CTC-LB2 Injector (633MB2)
8 41-1-8 Kick-Off Spring 26 44-71-1 Ball Valve (633MB2 Only)
9 63-83 Plunger 27 100-12 Vinyl Tube (1/4 ID S 8’ Lg.) (633MB2)
10 41-15-10 Diaphragm 28 100-12L Vinyl Tubing (3/8’ ID X 8’ Lg.)(633MB)
11 63-39 Valve Body 29 61-107-2 Ceramic Weight (633MB)
12 100-38 Strainer Washer 30 61-107 Ceramic Weight (633MB2)
13 63-32 Pipe to Garden Hose Adapter 31 100-11P Foot Valve
14 66-153 Pipe Plug w/ O-Ring 32 60-43 Hose Clamp
15 24-67 Screw (4 Req’d)
16 61-9 Metering Tip (Specify Size) ACCESSORIES
17 23-32T Metering Knob NO
. PART NO. DESCRIPTION
18 24-25 Check Valve O-Ring 33 61-9K Metering Tip Kit (13 Sizes)

This manual suits for next models

1

Other DEMA Laboratory Equipment manuals

DEMA 162HCGHT User manual

DEMA

DEMA 162HCGHT User manual

DEMA 94235 User manual

DEMA

DEMA 94235 User manual

DEMA 681GAP-2P User manual

DEMA

DEMA 681GAP-2P User manual

DEMA 633AG-1 User manual

DEMA

DEMA 633AG-1 User manual

DEMA 163CH User manual

DEMA

DEMA 163CH User manual

DEMA 163-2DF-2 User manual

DEMA

DEMA 163-2DF-2 User manual

DEMA Fusion One Assembly instructions

DEMA

DEMA Fusion One Assembly instructions

DEMA 633GAP Series User manual

DEMA

DEMA 633GAP Series User manual

DEMA 203BS-2EP User manual

DEMA

DEMA 203BS-2EP User manual

DEMA 700 Series User manual

DEMA

DEMA 700 Series User manual

DEMA 292QD AERATING WAND User manual

DEMA

DEMA 292QD AERATING WAND User manual

Popular Laboratory Equipment manuals by other brands

IKA ULTRA -TURRAX Tube Drive P control operating instructions

IKA

IKA ULTRA -TURRAX Tube Drive P control operating instructions

WPI SpectroPipetter SPT instruction manual

WPI

WPI SpectroPipetter SPT instruction manual

Varian 1200 LC/MS Operator's manual

Varian

Varian 1200 LC/MS Operator's manual

Lonza 4D-Nucleofector manual

Lonza

Lonza 4D-Nucleofector manual

Thermo Scientific Shandon TissueWave 2 Operator's guide

Thermo Scientific

Thermo Scientific Shandon TissueWave 2 Operator's guide

dosatron D8RE3000 Troubleshooting

dosatron

dosatron D8RE3000 Troubleshooting

Metrohm 930 Compact IC Flex manual

Metrohm

Metrohm 930 Compact IC Flex manual

Fluke Ti450 PRO Quick reference guide

Fluke

Fluke Ti450 PRO Quick reference guide

Abbott CELL-DYN 3000 Operator's manual

Abbott

Abbott CELL-DYN 3000 Operator's manual

VWR avantor instruction manual

VWR

VWR avantor instruction manual

Invitrogen BW1000 user guide

Invitrogen

Invitrogen BW1000 user guide

UGO BASILE 37360 instruction manual

UGO BASILE

UGO BASILE 37360 instruction manual

Thermo Scientific TSQ Altis Hardware manual

Thermo Scientific

Thermo Scientific TSQ Altis Hardware manual

overhoff TRIATHALON-H3 Operation and maintenance manual

overhoff

overhoff TRIATHALON-H3 Operation and maintenance manual

Labnet Spectrafuge 16M Service manual

Labnet

Labnet Spectrafuge 16M Service manual

gako  unguator EMP quick start

gako unguator

gako unguator EMP quick start

BI RDP-12 quick start guide

BI

BI RDP-12 quick start guide

Merck Milli-Q EQ 7008 user manual

Merck

Merck Milli-Q EQ 7008 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.