98
DSCS-9/10 Series
LLPCL006-1x-06/17(XXX)
CLEARANCESTO COMBUSTIBLES (in centimeters)*
FIREHAZARD.
Alwaysmaintain published clearances to combustibles.
Inlocations used for the storage of combustible materials, signs must be
posted.Consult manual for additional guidelines.
HOTWHILE IN OPERATION. DO NOT TOUCHhot surface. Contact may
causeburn. Allow to cool before servicing. Keepchildren, clothing,
furniture,gasoline, and other liquids having flammable vapors away.
Thisheater must be installed by qualified personnel only and in accordance with the
latestedition of the ANSI/NFPA Standards and E.U.Gas Safety Regulations 1984 and
BS6891:2015.Due account should be taken of any oblgations arising from the Health
andSafety at Work Act 1974, the current I.E.E. Regulations, and other relevantcodes
ofpractice.
1. Close electrical circuit (usually thermostat).
2. If the heater fails to light after 3 attempts, open electrical circuit and wait 5 minutes
beforerepeating.
AVOIDSERIOUS INJURY OR DEATH. Improper installation,
adjustment,alteration, service, or maintenance can cause property
damage,injury, or death. Read the installation, operation, and maintenance
manualthoroughly before installing or servicing this equipment.
Thisis not an explosion-proof heater.Where there is the possibility of flammable vapors
ordusts, consult the local fire marshal, fire insurance carrier, or other authorities for
approvalof the proposed installation. Always maintain minimum ventilationrequirements.
ENDVIEW 0°
SIDESIDE
BELOW
TOP
ENDVIEW 30°
30°
BEHIND
TOP
FRONT
BELOW
*Minimum mounting height is 199
centimetersabove the finished
floor.
ModelNo.: All Models
Mounting
Angle:
0°
w/guard
30°
stnd.
End(s): 31 31
Side(s): 46 36
Below: 122 122
Top: 33 33
Behind: N/A N/A
Front: N/A N/A
SIDEVIEW
END END
0°
stnd.
31
N/A
102
46
46
92
Safety Labels and Their Locations
It is important to provide warnings to alert individuals to potential hazards and safety actions. Safety
warning labels must be maintained on the infrared heater. Illustrations of the safety labels and their
locations are pictured below. In locations used for the storage of combustible materials, signs must be
posted to specify the maximum permissible stacking height to maintain the required clearances from the
heater to combustibles. Signs must either be posted adjacent to the heater’s control or, in the absence of
such control, in a conspicuous location.
Figure 2.2 •Heater Safety Label Locations
2.0 Safety •Safety Labels and Their Locations
Clearances to combustibles must be maintained at
all times in order to prevent the ignition of
combustible materials. In locations used for the
storage of combustible materials, signs must be
posted to specify the maximum permissible stacking height to
maintain the required clearances from the heater to the
combustibles. Signs must either be posted adjacent to the
heater’s thermostats or, in the absence of such thermostats, in a
conspicuous location. Clearances are provided on the heater’s
safety label and in the heater’s Installation, Operation, and
Maintenance manual. Product installation and operation must
comply with applicable standards, codes, and regulations. Post
this tag adjacent to the heater’s thermostat or controls before
operating the heater.
- INSTALLER: READ AND POST THIS NOTICE -
LL001-XM-07/18 (CDS)
This product can
expose you to
chemicals including
lead and carbon
monoxide, which are known to the
State of California to cause birth
defects or other reproductive harm.
For more information go to
www.P65Warnings.ca.gov.
WARNING
!
Avoid Serious Injury, Death, or Property Damage.
Maintain Clearances to Combustible to Prevent the Risk of Fire.
California Proposition 65
Front Panel
0086
DSCS-9.0-G20
Gas Safety Installation and Use Regulations 1984
BS 6896:2005
I.S. 3212:1987, ICP 4, I.S. 327
06/17
-
2.35 50
0.12
mm
STARTINGAMPS
GROSS
GROSS
SAMPLE
Side Panel
End Panel
Rating Label (inside panel)
IGNITION
MODULE
ELECTRODE
ASSEMBLY GASVALVE
230VAC DSI MODULE
OPR GY
BK
BL
G/Y BR
L2
L1
W
BR
BK
BL
G/Y
G/Y
BR BL
G/Y
LLWP007-1M-11/18 (CDS)
1
50 Hz
PROVIDE
230 VAC
FROM CLASS II
SOURCE ONLY
DISCONNECT
POWER
BEFORE
SERVICING!
DANGER
230V
!
LLPCL006-1x-06/17 (XXX)
CLEARANCES TO COMBUSTIBLES (in centimeters)*
FIRE HAZARD. Always maintain published clearances to combustibles.
In locations used for the storage of combustible materials, signs must be
posted. Consult manual for additional guidelines.
HOT WHILE IN OPERATION. DO NOT TOUCH hot surface. Contact may
cause burn. Allow to cool before servicing. Keep children, clothing,
furniture, gasoline, and other liquids having flammable vapors away.
This heater must be installed by qualified personnel only and in accordance with the
latest edition of the ANSI/NFPA Standards and E.U. Gas Safety Regulations 1984 and
BS6891:2015. Due account should be taken of any oblgations arising from the Health
and Safety at Work Act 1974, the current I.E.E. Regulations, and other relevant codes
of practice.
1. Close electrical circuit (usually thermostat).
2. If the heater fails to light after 3 attempts, open electrical circuit and wait 5 minutes
before repeating.
AVOID SERIOUS INJURY OR DEATH. Improper installation,
adjustment, alteration, service, or maintenance can cause property
damage, injury, or death.Read the installation, operation, and maintenance
manual thoroughly before installing or servicing this equipment.
This is not an explosion-proof heater.Where there is the possibility of flammable vapors
or dusts, consult the local fire marshal, fire insurance carrier, or other authorities for
approval of the proposed installation. Always maintain minimum ventilation requirements.
END VIEW 0°
SIDESIDE
BELOW
TOP
END VIEW 30°
30°
BEHIND
TOP
FRONT
BELOW
* Minimum mounting height is 199
centimeters above the finished
floor.
Model No.: All Models
Mounting
Angle:
0°
w/ guard
30°
stnd.
End(s): 31 31
Side(s): 46 36
Below: 122 122
Top: 33 33
Behind: N/A N/A
Front: N/A N/A
SIDE VIEW
END END
0°
stnd.
31
N/A
102
46
46
92 Top Panel
F/N: LL001
Clearance Safety Tag
(affix adjacent to heater’s control device) F/N: LLPCL011
Warning Label
F/N: LLDR009 (Nat. Gas)
F/N: LLDR010 (Prop. Gas)
Gas Type Label
F/N: LLPCL012
230 Volts
F/N: LLWP007
Wiring Diagram (inside panel)
F/N: LLOGO026
Designer Series Plaque
F/N: PCL006
Clearances to Combustibles Label
LLPCL011-1M-04/16(CDS)
WARNING
Donot operate
thisappliance
beforereading
theinstr uction
booklet.
Donot place
articles on or
againstthis
appliance.
Donot store
chemicalsor
flammable
materials,or
sprayaerosols
nearthis appli-
ance.
Donot operate
withpanels,
removedfrom
thisappliance.
Donot operate
room.
Donot operate
ina room with a
200M3.
Notsuitable for
indoordomestic
use!
WARNING
Do not operate
this appliance
before reading
the instruction
booklet.
!
Do not place
articles on or
against this
appliance.
Do not store
chemicals or
flammable
materials, or
spray aerosols
near this appli-
ance.
Do not operate
with panels,
covers, or guards
removed from
this appliance.
Do not operate
room.
Do not operate
in a room with a
volume less than
200M3.
Not suitable for
indoor domestic
use!