The currently selected output port of the transformer has no output voltage,
and the load lamps do not light up.
Figure 1: OFF MODE
The currently selected output port of the transformer will maintain the output
through the day, and the load lamps will be always on.
Figure 2: ON MODE
In this mode, it will also take 0-30s for the transformer to detect the external
environment firstly. If it is night, the currently selected output port of the
transformer will start output later and the load lamps will light. Then they will
turn off automatically when the the countdown is over. If it is during the day,
the currently selected output port of the transformer will have no output and
the load lamps will not light.
Note: When the system starts to count down, if the surrounding light shines
on the sensor for more than 30s, the countdown will end, the currently
selected output port of the transformer will stop output, and the load lamps
will go out.
Figure 4 & Figure 5: COUNTDOWN MODE
In this mode, it will take 0 ~30s for the transformer to detect the external
environment firstly. If it is night, the currently selected output port of the
transformer will start output later, then the load lamps will light on
automatically and off at dawn. If it is during the day, the currently selected
output port of the transformer will have no output and the load lamps will
not light.
Note: If the light emitted by the load lamps shines on the sensor at night,
it may cause the transformer to continuously switch on/off, and the load
lamps flash continuously, with a flash interval of 30s.
Figure 3: AUTO MODE