Diesella 15305210 User manual

INTENDED USE
The refractometer is a measuring instrument for determining the refractive index of transparent
substances in the liquid or the solid state. It is used to observe the behavior of light as it passes
from a prism with known properties to the substance being tested. Use of the refractometer for
other purposes is contrary to its intended use and may be hazardous. The manufacturer shall
not be liable for any damages caused by improper use.
15305210: This refractometer is designed to work with high sugar sugar related liquids, honey,
jellies, jams and syrups to help monitor and control sugar concentrations in foods and beverages.
15305215: This refractometer has been specially designed to determine the moisture in honey.
Honey is a hygroscopic liquid that has excellent water absorbing properties, which is why honey
will change in moisture content according to the surrounding atmosphere. The moisture level in
natural, raw honey usually varies from 14% to 18% (or more).
PACKAGE CONTENTS
After unpacking and before using the device for the rst time, check that all listed parts have
been supplied. Replace damaged or faulty parts immediately and do not put them into
operation.
• Refractometer
• Storage box
• Pipette
• Adjustment tool
• Cleaning cloth
• Calibration oil and stone
• Operating instruction
INTRODUCTION
This user manual is for the refractometers item no. 15305210 / 15305215 (afterwards referred
to as the appliance) and provides important information on the use, safety, connection and
operation of the appliance. The user manual must always be kept near the appliance. It must
be read and used by the persons who have the task of operating and repairing faults on the
refractometer. Keep this user manual and leave it with the appliance if you pass it on to others.
LIMITATION OF LIABILITY
All technical information, data and information on connection and operation are in accordance
with the latest knowledge at the time of printing. No requirements can be made based on the
information, pictures and descriptions in this guide.
The manufacturer accepts no liability for damage due to non-compliance with the instructions,
use that does not fall within this scope, incorrect repairs, alterations made without permission
and use of unauthorized spare parts.
BASIC SAFETY INSTRUCTIONS
Observe the following safety instructions for safe use of the appliance:
• Check the appliance for external, visible damage before use. Do not use the appliance
if it is damaged. There is a risk of electric shock.
• Only have the appliance repaired by authorized specialist shops or customer service.
• Improper repairs can result in signicant damage hazards to the user.
Furthermore, ALL warranty claims are canceled.
• NEVER place the appliance in a window - there is a risk of re!
• This appliance must not be used by persons (including children) limited physical,
sensory or mental abilities or with lack of experience and/or lack of knowledge,
unless a responsible person supervises them and gives them instructions for
how to use the appliance.
• Children must be supervised to ensure that they do not play with the appliance.
We thank you for choosing a refractometer developed by Diesella. With this operating
instruction, we would like to help you get started using the product and ensure you get the
best user experience. Please keep this manual a safe place for later reference or use.
FIELD OF APPLICATION
This appliance is for indoor use only and can be used in working temperature from
10°C to 30°C.
All other uses are considered to be outside the scope. No claims can be made in connection
with damage caused by the use of the appliance for purposes for which it is not intended.
The owner bears the risk alone.
UNPACKING
NOTE
• Check that all parts are witin the package and that they do not have visible damage.
• If parts are missing or damaged due to defective packaging or transport,
please contact the dealer where you purchased the device.
• Take the appliance and the user manual out of the box.
• Remove all packaging material.
WARNING: Packaging materials must not be used for children’s play.
There is a danger of suffocation!
DISPOSAL OF THE PACKAGING
The packaging protects the lamp from transport damage. The packaging materials are
selected based on criteria such as environmental compatibility and disposal technology
and can therefore be recycled.
When handing over the packaging for recycling, many raw materials are saved and the
amount of waste is reduced. Dispose of packaging materials that are no longer to be
used in accordance with local regulations.
DEVICE DESCRIPTION
1. Prism cover
2. Prism surface
3. Adjustment screw
4. Eyepiece with rubber eyeshade
5. Diopter adjustment ring
6. Optical tubes with rubber grip
7. Storage box
8. Pipette
9. Refractometer
10. Calibration oil and stone
11. Adjustment tool
12. Cleaning cloth
DISPOSAL OF THE APPLIANCE
The packaging consists of environmentally friendly materials which can be disposed of via local
recycling facilities. The device and storage box should be disposed of by the operator in
accordance with applicable national or regional regulations at the place of use.
Do not dispose of the appliance with normal household waste.
• Dispose of the appliance at an approved waste disposal company
or at your municipal waste facility.
• Follow the current rules. Contact the waste disposal system if in doubt.
OPERATING INSTRUCTION
REFRACTOMETER HONEY SUGAR | HONEY WATER
Item no. 15305210 | 15305215
UK
The product may differ slightly from the illustrations.
5
6
7
8
9
10 11
12
1
2
3
4

ANALOGUE REFRACTOMETRE (HONEY)
SERVICE
After reading this operating manual, if you have any questions about setting up or using the
refractometer, or if any unexpected problem occurs, please contact your dealer.
WARRANTY!
The warranty shall be void in the event of:
• Failure to observe the instructions in the operating manual
• Use for purposes other than those described
• Changes or opening of the appliance house
• Mechanic damage and/or damage in cause of media, uids, natural wear
OPERATION AND FUNCTION
Zero Point Calibration and measurement procedure
The refractometer can be used to determine the refractive index of transparent substances,
liquid or solid ones quickly and accurately. To ensure correct measurement, the measuring
device should be adjusted before measurements are carried. out. Please make sure your
hands are dry before handling the measuring device.
1. Start by removing the protective lm (if present) from the prism surface [2]
and check that the rubber eyecup [4] is tted correctly.
2. Hold up the refractometer against a sufciently bright light source and look through
the eyepiece [5], holding the rubber eyeshade [4] closely against your eye/glasses.
3. Rotate the eyepiece [5] to adjust it for your eyesight, until you can see the scale sharply.
4. Open the prism cover [1].
5. Thoroughly clean the prism [2] and the underside of the prism cover [1] using a soft
cloth or soft paper (with alcohol if necessary) and wipe dry.
6. Now apply a few drops of the calibration liquid [10] onto the prism surface [2].
7. Close the prism cover [1]. The amount of uid should be sufcient to moisten most of
the prism surface. There should not be any air bubbles between the measuring prism
[2] and prism cover [1].
8. Wait about 30 seconds to allow the temperatures of the uid and prism to equalize.
9. Look through the eyepiece [4] while pointing the prism surface [2] at a bright light source.
10. Through the eyepiece [4], you will see a bright and a blue eld. The boundary line
between them shows the measured value on the scale which is also visible
through the eyepiece [4].
11. Use the supplied adjustment tool [11] to turn the adjustment screw [3] behind the
prism surface [2] (under the rubber cap) and adjust the scale so that the measuring
device is optimally set up by moving the boundary line upwards or downwards.
12. Repeat step 4 (cleaning).
MEASUREMENT PROCEDURE
It is important that the samples being measured are representative samples. For samples that
evaporate easily, measurements should be carried out quickly. The samples should be at the
same temperature as the measuring instrument in order to achieve an accurate result.
1. Make sure your hands are dry before handling the refractometer.
2. Open the prism cover [1] and use the supplied pipette [8] to apply a few drops of the
sample liquid [8] onto the prism surface [2]. Close the prism cover [1]. Spread the liquid
evenly by pressing down on the prism cover [1] and eliminate any air bubbles present.
3. Hold the device horizontally and wait about 30 seconds (for optimal temperature equal
ization between the sample and device).
4. View the measurement scale through the eyepiece [4]. Point the prism surface [2] of the
refractometer at a bright light source while doing this.
5. Rotate the adjustment ring [5] on the eyepiece [4] to adjust the focus.
6. The boundary line will move on the measurement scale depending on the
concentration. This bright/dark boundary line shows the result on the scale.
7. If the temperature deviates from +20 °C and a refractometer without ATC is used,
correct the measured result using the corresponding value from the temperature
correction table [13].
8. Carefully clean the supplied pipette [8] and the refractometer after carrying
out the measurement.
IMPORTANT!
After every measurement, use a lint-free, absorbent cloth to remove the uids from the prism
surface [2] and prism cover [1]. Then carefully clean the prism and prism cover using a
cloth moistened with water or if necessary, alcohol, and dry both parts using a soft,
dry and lint-free cloth. Avoid rubbing the prism [2].
Model Measuring range Scale
resolution
Scale accuracy Product
dimension
Net.
weight
15 3 0 5 21 0 58-90% Brix
12-27% Water
0.5% Brix
0.5% Bé
1% Water
±0.5% Brix
±0.5 Bé
±1% Water
145 × Ø40 mm 193 g
15305215 10~30% Moisture 0.1% ±0.1% 170 × Ø40 mm 207 g
CLEANING AND MAINTENANCE
Clean the refractometer using a soft, lint-free cloth moistened with either water or,
if necessary, alcohol. Do not use any aggressive or abrasive cleaning agents. Never
immerse the device in water or hold it under running water. Never handle the device
with wet or damp hands. Never touch the measuring prism [2] with hard tools made
from plastic, wood, rubber, metal, glass etc. Hard objects can quickly damage the
relatively soft prism glass, resulting in measurement errors. The refractometer is
maintenance-free. Cleaning should be carried out immediately before and after each
use of the refractometer to maximize its life and optimize measurement results.
• Avoid exposing the refractometer to direct sunlight.
• Never bring the refractometer into contact with solvents.
CALIBRATION PROCEDURE
1. The dioptric oil can attack the cover plate (all plastic and rubber),
please keep it away from the cover plate.
With repeated contact, the dioptric oil can cause cracking and fogging of the
cover plate. When you do the calibration, the calibration stone must be used
and it will act as a cover plate during calibration.
2. Put one drop of dioptric oil on the long-sided surface of the calibration stone.
Open the daylight plate, put the calibration stone (oily side down) on the surface
of the prism and press it lightly with your hand to prevent it from sliding down.
3. Rotate and adjust the calibration screw to make the white and blue boundary
t with the following reference reading: Water 19.6% or 78.8% Brix.
Honey refractometers need special calibration oil and stone.
This refractometer cannot be calibrated by using a standard conguration.
All refractometers are pre-calibrated and therefore there’s usually no need to calibrate it.
ART. 15305210 ART. 15305215
Diesella A/S | Marsvej 20 | DK-6000 Kolding | Tel. +45 7633 8888 | info@diesella.dk | www.diesella.dk
This manual suits for next models
1
Other Diesella Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

Macherey-Nagel
Macherey-Nagel NANOCOLOR Advance Operating instruction

Elcometer
Elcometer Zahn 2210 operating instructions

Endress+Hauser
Endress+Hauser Deltapilot M FMB50 Brief operating instructions

Nagman
Nagman MTC Series manual

PPS
PPS PPS36 user manual

Hanna Instruments
Hanna Instruments HI762 instruction manual