digicon dTower User manual

Product Manual
Tower


All rights reserved. No part of this publication may be reproduced,
transmitted, transcribed, stored in a retrieval system, translated into any language
or computer language in any electronic, magnetic, optical, chemical, manual way,
or otherwise, without the express written permission from Digicon S.A.
Code: 069.31.221
Version: 0 -2 English
This manual was elaborated by: Digicon S.A. Controle Eletrônico para Mecânica
Documentation Sector - EDS
Copyright– Digicon S.A.
Controle Eletrônico para Mecânica – 2017
©
Tower

Contents
05
06
06
07
08
09
09
10
14
15
16
17
22
24
24
25
26
26
26
27
1. .................................................................................Important instructions
2. ...............................................................................................Orientations
3. ...............................................................................................Introduction
4. ......................................................................................Features of dTower
4.1 ....................................................................................dTower Pictograms
5. ............................................................................Installing and Assembling
5.1 .................................................................................................Unboxing
5.2 .......................................................................Fixing dTower to the ground
5.3 .................................................................Accessing dTower after assembly
5.4 ..........................................................Connections among equipment pieces
5.5 .......................................................Connection to power and data networks
5.6 ..........................................................................Connecting control signals
5.7 controller board .................................................................Configuration of
6. ...............................................................................Technical characteristics
6.1 ..............................................................................................Dimensions
6.2 ......................................................................................Other information
7. ....................................................................................................Cleaning
7.1 ........................................................Maintenance and preservation of doors
7.2 ....Maintenance and preservation of dTower (glasses and stainless steel sheets)
8. .................................................................Warranty and technical assistance
Tower

1. Important instructions
You can see, below, the symbols that will appear in this manual, signaling
important moments. It is essential to pay attention to them.
TIP: Indicates something Digicon considers important.
CAUTION: Indicates a moment of extreme caution when
handling the equipment/product.
ATTENTION: Indicates a moment when your observation
skills should be extremely productive.
INFORMATION: Presents interesting facts about the
purchased product.
QR CODE: Presents additional information or links with
more details about the presented text.
05
Tower

06
Read the information and instructions of this manual carefully, before using the
product. This ensures the correct use of the equipment and maximum use of its
technical features as well as a prolonged service life.
This product does not present sealing against the rain, that is, it is designed to
be used indoors.
Keep this manual for future consultations.
Digicon reserves its right to alter its products at any moment to adapt them to
more recent technical advancements.
Digicon maintains its right to alter the information contained in this manual
without previous notice.
Digicon does not provide any contractual warranty concerning the information
in this manual, and cannot be held responsible for errors it may contain and
problems due to its use.
The information contained in this manual is exclusive property of Digicon and is
protected by copyright laws.
This manual cannot be reproduced, photocopied or translated, in its entirety or
in part, into any kind of medium, without Digicon's written consent.
The equipment described here is customizable, that is, this manual describes
all possible models and they may not reflect, necessarily, the model purchased
by the customer.
2. Orientations
3. Introduction
Gate line especially developed for access control solutions that operate in small
spaces. Using the comfort and safety of swing gate doors, the dTower line offers
maximum flexibility with minimum use of space.
Tower

4. Features of dTower
-Innovative design, according to the dGate and dFlow lines;
-Robust solution, with motorized system and control with proprietary technology;
-Reinforced structure for fixing it to the ground;
-Available in stainless steel and carbon steel painted in powdered epoxy;
-Available with doors in 1 mm polymer – more resistant to impacts;2
-Very fast door opening;
-Offers operational pictogram (top) – clear access;
-Offers orientation pictograms (front) for both directions;
-Offers sound signal (beep) to indicate access cleared or denied;
-Doors with bidirectional movement;
-Inputs for activation sensors that open or close the doors;
-Optional card collecting box;
-Allows installation of reader on the edges;
-Easy integration with access controllers available in the market.
07
Tower

4.1 dTower Pictograms
dTower has two pictograms: direction and operation
A) Operational pictogram (top):
The operational pictogram is installed on the upper part of the equipment and is
represented by a sequence of LED lights in several colors, depending on the
operational flow direction and validation group, if it exists.
LED lights flashing red or flowing in the opposite direction represent passage not
cleared.
LED lights flashing green indicating the direction of passage represent cleared
passage.
B) Orientation Pictogram (front)
The orientation pictogram is installed on the edges of the equipment and is
represented by a green arrow > or red x.
The red pictogram informs the user that dTower is not operating in the indicated
direction or that passage is not allowed, or even that it is busy.
The green pictogram informs the user that dTower is free or controlled for passage
in the indicated direction.
08
Tower
and

5. Installing and Assembling
5.1 Umboxing
As the items inside the package can vary (since the equipment is customizable), it is
important to perform a cautious visual inspection before installing and assembling the
turnstile. A checklist that works as a guide during inspection accompanies all Digicon
packages. In case of missing pieces, immediately contact the Digicon representative
responsible for the sale.
2D Reader
Orientation
pictogram:
and
Operational
pictogram
Swing Gate
Door
Upper
cover
Key Lock
Access Door
Stainless Steel Column
Identification
label (by color)
09
Tower

5.2 Fixing dTower to the ground
The image below indicates the points for fixing the product to the ground.
The surface must be steady and leveled to ensure good performance for the
passage-controlling sensor and to maintain the doors aligned.
Fixing can be done through mechanical bolts, also known as parabolts, or through
chemical anchorage.
It is very important to check, upon installation, the alignment of the doors in the
closed position. The distance, from top to bottom, must be the same.
TIP:
To fasten the bolts, use a tool with long extensor.
- Fixing points
- Optional fixing points
INFORMATION: Measures are given in millimeters and (inches).
10
Tower
170(6,692")
93
(3,661")
90(3,543")
80
(3,14")
24(0,944")
Ø15(0,590")
Ø13(0,511")
TIP: We recommend bolts by Tecnart, model AF38110, 3/8x4''.

Passage free span:
With the fixing perforations ready, install the fixing threaded bars according to the
drawing below. Digicon recommends using the chemical capsule anchor system
by Hilti ( ).www.hilti.com.br
INFORMATION:
Digicon meets the norm
ABNT NBR 9050:
Accessibility to
buildings, furniture,
space and urban
equipment.
90°
283
(11,141")
11
INFORMATION: We recommend
using the chemical anchorage;
however, if you prefer parabolts, make
sure the ground is adequate.
Tower

Step-by-Step:
1. Use the 12mm (0,47'') drill to drill the hole with depth of 90mm (Threaded
bar M10);
2. Clean the hole with an air blower or a vacuum to remove any debris;
3. Place the threaded bar inside the hole and measure the depth. The bar has
a mark that must be leveled with the ground;
4. Place the capsule HVU inside the hole;
5. Attach the threaded bar to the drill and screw it until it reaches the hole's
bottom or until the mark of the threaded bar is leveled with the ground;
6. Apply the drill until the chemical material rises to the surface;
7. Do not touch the threaded bar until the chemical reaction is over (10min);
8. Cure time according to the table:
12
Tower
Cure time in general conditions
Base material temperature
Cure time necessary for the fixing to receive
total load tcure
20°C to 40°C 20min
10°C to 19°C 30min
0°C to 9°C 1h
-5°C to -1°C 5h
Data according to ETA 05/0255/0256/0257, edition 2010-03-01 / 2006-01-20

9. Tightening torque and other information can be seen in the table below:
13
Tower
Estimate resistances must be reduced to distances from edge and spacing
smaller than critical values.
a) h: base material thickness (h h );> min
b) This is the maximum tightening torque recommended to avoid
rupture by cracking during installation for fixings with minimal distance
from edge and/or spacing.
M8 M10 M12 M16 M20 M24 M27 M30
Nominal diameter of drill d0[mm] 10 12 14 18 24 28 30 35
Effective depth of hole and
anchorage hef [mm] 80 90 110 125 170 210 240 270
Diameter of hole on sheet df[mm] 9 12 14 18 22 26 30 33
Minimum space Smin [mm] 40 45 55 65 90 120 130 135
Minimal distance form
edge Cmin [mm] 40 45 55 65 90 120 130 135
Critical spacing for rupture
by cracking Scr.s p
hmin
a)[mm] 140 160 210 210 340 370 480 540
Ccr.s p [mm] 160 180 220 250 340 420 480 540
hmin
a)[mm] 160 180 220 250 340 420 480 540
Ccr.s p [mm] 100 130 180 180 340 340 480 540
hmin
a) [mm] 110 120 170 170 220 300 340 380
Ccr.s p [mm] 130 150 220 250 340 420 480 540
hmin
a) [mm] 160 180 220 250 340 420 480 540
Ccr.s p [mm] 80 20 110 125 170 210 240 270
hmin
a) [mm] 110 120 140 170 220 270 300 340
Ccr.s p [mm] 80 90 110 125 170 210 240 270
2cr.s p
Anchorage diameter
Data according to the ETA-05/0255/0256/0257,
edition 2010-03-01/2006-01-20
Critical distance from edge for rupture by cracking – Temperature range I
Critical distance from edge for rupture by cracking – Temperature range II
Critical distance from edge for rupture by cracking – Temperature range III
Optimized for minimum
thickness of base material
Optimized for minimum
spacing
Optimized for minimum
thickness of base material
Optimized for minimum
spacing
Critical spacing for
rupturing by cement
cone
Scr.N
Critical distance from
edge for rupture by
cement cone
Ccr.N
Tightening torque b) Tmax [Nm] 10 20 40 80 150 200 270 300
2 Ccr.N
1,5 hef
Installation details

5.3 Accessing dTower after assembly
After is installed and assembled, access to the interior of the equipment candTower
be done with the key that accompanies the equipment, in 2 ways:
1. Via the upper glass cover: access the readers, pictograms and engine board;
2. Via the inner side door: access the Controller board, connection terminals and
source.
14
Lock for opening
upper glass cover
Lock for opening
inner side door
Tower

5.4 Connections among equipment pieces:
Interconnection cables can be found in the dTower Receptor and must pass through
the ducts as seen below:
Interconnection duct for communication cables
Interconnection duct for CA cable
JUNCTION BOXES
4"x4"
Conduit with 50mm
diameter
Transmitter Receptor
15
Exit
Entrance
Tower
Cable
passage

power and data networks5.5 Connection to
TIP: We recommend using good quality AC and grounding cables, with
dimensions compatible with the distance until the switchboard. The data
cable must be CAT5E. Recommended manufacturers: FURUKAWA and AMP.
CAUTION: Electrical connections must be performed by qualified
professionals.
There two ways of supplying power to :dTower
1º With inner source: Power supply to the equipment must be 100 to 240Vca.
2º With outer source: Power supply must be 24Vcc (+/- 5%) by module.
Digicon recommends using the norm NBR 5410 as reference for electrical installations of
equipment pieces.
Power cables of power supply must be connected to the circuit breaker and the ground
cable in yellow/green terminal.
Tower
16
Grounding
Power network
Supply

5.6 Connecting control signals
Enabling dry contact with 2 relays:
Enabling both directions with only 1 relay:
7654321
U
UU
UU
UU
UU
U
Dry Contact
Clockwise
Enab.
Anti-
clockwise
Enab.
7654321
UUUUU
Relay
Integrator controller
Dry contact (simultaneous)
Tower
17

Enabling by solid state (positive, positive voltage):
Enabling solid state (negative)
654321
Anti-
clockwise
Clockwise
Vcc Vcc
Vcc = 5~24V
Integrator controller
Tower
18
54321
Vcc
Vcc = 5~24V
Integrator controller
Anti-
clockwise
Clockwise

Confirming passage
Vcc - True logical level, configured in “disk emulation”DIP Ds2 n°7 in ON.
Integrator controller
Vcc
4321
Positive digital input
UUUUU
NA NF
Rl2
3
4
NA NF
1
2
Rl1
UUUUU
Clockwise
turn
Anti-
clockwise
turn
Tower
19

Integrator controller
4321
Negative digital input
Confirming passage by disk emulation
Firmware version 2.0.0 or superior
Confirming passage by pulse
Confirmation of passage by pulse or “disk emulation”can be configured through the
dipswitch Ds2 n°7; if it is on, it will emulate the disk; if it is off, pulse will be
generated when passing.
Confirming passage - Negative
1
1
Rl1
Rl2
1
1
Rl1
Rl2
Tower
20
Other manuals for dTower
1
Table of contents