Contents
1. Important instructions .........................................................................05
2. Orientations .......................................................................................06
3. Introduction .......................................................................................06
4. Features of atrax FitC ...........................................................................07
4.1 atrax Fit OperationC ...........................................................................08
5. Installation/Assembling Catrax Fit .........................................................09
5.1 Unboxing .........................................................................................09
5.2 Floor drilling .....................................................................................10
5.3 Colum fixation ..................................................................................10
5.4 Assembling the arms .........................................................................11
5.5 Access to Catrax Fit after assembling ....................................................12
5.5.1 Cover ...........................................................................................12
6. Optional items ...................................................................................13
6.1 Pictogram kit ...................................................................................13
6.2 Electric counter kit ............................................................................14
6.3 Power supply ...................................................................................16
6.4 Control board ...................................................................................17
6.4.1 Inputs ..........................................................................................20
6.4.1.1 Connection scheme .....................................................................21
6.4.1.2 Pictogram ..................................................................................21
6.4.1.3 Pictogram's connections ...............................................................21
6.4.2 Configuration of control board – Switch Ds1 .........................................22
6.4.3 Outputs ........................................................................................22
6.4.3.1 Return signals .............................................................................23
6.4.3.2 Electromagnets ...........................................................................23
6.4.3.3 Sound alarm...............................................................................23
6.4.4 Examples of some configurations ......................................................24
6.5 Anti-Panic System .............................................................................25
7. Maintenance ......................................................................................26
7.1 Preventive and corrective routine maintenance .......................................26
7.2 Defects and possible causes ................................................................28
8. Technical characteristics ......................................................................29
8.1 Dimensions ......................................................................................29
8.2 Other information ..............................................................................30
9. Warranty and Technical Assistance .........................................................31

05
1. mportant nstructionsI i
You can see, below, the symbols that will appear in this manual,
signaling important moments. It is essential to pay attention to them.
TIP: Indicates something Digicon considers important.
CAUTION: Indicates a moment of extreme caution when
handling the equipment/product
ATTENTION: Indicates a moment when your observation
skills should be extremely productive.
INFORMATION: Presents interesting facts about the
purchased product.
QR CODE: Presents additional information or links
with more details about the presented text.

2. Orientations
Read the information and instructions of this manual carefully, before using the
product. This ensures the correct use of the equipment and maximum use of its
technical features as well as a prolonged service life.
This product does not present sealing against the rain, that is, it is designed to be
used indoors.
Keep this manual for future consultations.
Digicon reserves its right to alter its products at any moment to adapt them to more
recent technical advancements.
Digicon maintains its right to alter the information contained in this manual without
previous notice.
Digicon does not provide any contractual warranty concerning the information in this
manual, and cannot be held responsible for errors it may contain and problems due
to its use.
The information contained in this manual is exclusive property of Digicon and is
protected by copyright laws.
This manual cannot be reproduced, photocopied or translated, in its entirety or in
part, into any kind of medium, without Digicon's written consent.
3. Introduction
Following a new technological concept focused on solidity and reliability and counting
with innovative design elements, with color variety and widely curved lines, Digicon has
launched the line C Fit.atrax
C Fit serves most technologies of access control currently available at companies,atrax
condominiums, clubs, and gyms. This manual presents a detailed description of the
components and working of C Fit.atrax
To see our complete catalogue, visit www.digicon.com.br

4. atraxFeatures of C Fit
C Fit, an access controller in the model mini turnstile (column type), presents threeatrax
bidirectional, equidistant arms at 120 degrees with brushed stainless steel (AISI 304)
finishing.
The column can present external 1020 carbon steel finishing with electrostatic painting
in black or grey epoxy powder.
It has reinforced structure, fully rounded corners, and non-exposed screws, offering
space and comfort for any access control solution.
Standard holes for the fixation of additional electronic boards. Moreover, the clients,
according to their needs, can add additional holes. Access to the support is done through
a key with secret, whose removal and insertion are extremely easy.
A plastic cover and a stainless steel sheet compose the upper panel. The cover, made of
injected plastic, can be purchased in the colors green, burgundy, or black or in any other
color desired, on demand. Optionally, the cover can present a slot for the reading of
magnetic cards/badges and barcodes.
The upper cover in stainless steel allows easy configuration and low-cost customization
of the product. The sheet can also present slots for optional items, such as pictogram,
display kit, or a combination of these items.
Besides compatibility with most available technologies, Digicon can provide the
following optional items: pictogram kit, counter kit, power supply, and control board.

INFORMATION: The turning of the turnstile can be blocked only with the
activation of the electromagnets. If the turnstile has no power supply, the
turning mechanism remains free.
4.1 C Fit Operationatrax
In the basic mechanism, C Fit has a two-dimensional rotation system with twoatrax
12 V electromagnets for activating the locks and two optical sensors that can provide
the signal for the activation of the electromagnets and passage clearance.
In the electronic model, which includes a microprocessor control board (optional), a
signal enabling passage is sent through one of the inputs, depending on the passage
direction. If this signal is recognized, the equipment will allow the turning of the arm
of C Fit. After half of the turning is complete (60 degrees), a 400 millisecondsatrax
returning signal will be sent, informing the passage direction. After the signal, the
arm cannot be returned to the previous position.
Depending on the C Fit model and configuration, if the passage is forced withoutatrax
the enabling signal, an electromagnet will be activated to prevent turn. In addition,
the equipment can emit a signal for a sound alarm and/or the exhibition of a red X on
the upper panel display (models with pictogram). In this case, a return signal will be
sent, indicating that the turnstile was forced, informing the direction of turn.
-Mechanisms of C Fit:atrax

5. Installing/Assembling C Fitatrax
5.1 Unboxing
As the items inside the package can vary (depending on the client's requests), it is
important to perform a cautious visual inspection before installing and assembling the
turnstile. A checklist that works as a guide during inspection accompanies all Digicon
packages.
See below the parts that can compose C Fit:atrax
ATTENTION: To avoid losses, the screws and the wrenches used for
assembling the C Fit are attached to the box containing the arms.atrax
Before discarding the packing materials (cardboard and plastics), make
sure all the items in the checklist are accounted for.
Left to right direction
Right to left direction
Arm
Lock
Cables
passage
Steel sheet
Plastic
cover kit
Column

5.2 Floor drilling
Before installing C Fit, check:atrax
-If there will be enough space.
-The place chosen for the installation.
-If there is a power source or electric socket nearby (ducts for connection);
-if the place chosen is adequate for the installation of the access controller (indoors);
-if there will be enough space (minimum 5 cm) between the rear of the C Fitatrax
column and the wall. This space is important in order to provide access to the upper
panel and plug's locks for the cables passage.
-if there will be enough space for the arms after C Fit is assembled.atrax
-If the floor is in conditions to receive anchor bolts (minimum of 4 cm of FCK15 M.P.A.
concrete or equivalent).
5.3 Colum fixation
To fixate the column to the floor, observe the following steps:
1. drill the floor with 3/8” drills (then use a 12mm or the ½” drill). Make 4 external
holes, according to the measures indicated in the image below:
ATTENTION:Since the C Fit's installation requires floor drilling, itatrax
is important that the location be chosen carefully.
Measures in millimeters and inches.
120 (4,724")
54 (2,125")
51 (2,007")
230 (9,055")

ATTENTION: in the central slot, destined to the passage of cables, it is
necessary to measure the cables according to the opening's size.
TIP: As an optional item, Digicon can provide a steel template for the
fixation of Catrax Fit, containing the exact demarcations of the necessary
holes.
2. Clean the holes, removing any debris from drilling.
3. Place the external part of the bolts in the holes. Leave about 25mm of the bolt out
of the hole.
4. Position the column and fasten it to the floor with the four screws that accompany
the bolts. Use a flex-head socket wrench with ¾'' or an articulated socket wrench.
5.4 Assembling the arms
After drilling the floor and assembling the column, it is possible to assemble the arms
and plastic covers.
The image below shows the specific parts of C Fit's arms and upper frontalatrax
cover.
TIP: We recommend the bolts by the brand Tecnart, model AF38110,
3/8x4''.
Screw M3x8
Screw M3x16
Upper plastic
cover
Flat washer M3
Arm
*Screws’access cover
*Screw Allen M6x20
*Lock washer M6

1º 2º
3º 4º
5.5 Access to C Fit after assemblingatrax
After Catrax Fit is installed and assembled, access to the interior of the equipment can
be done with the key that accompanies the equipment.
5.5.1 Cover
1. Open the lock with the smaller key (clockwise)
2. Unscrew the two screws in the turnstile's front
3. Pull the cover forward, disengaging the back pins
4. Drag the cover until it is completely out
See the images below:

6. Optional items
Catrax Fit is compatible with most access control technologies in the market today;
however, Digicon offers a range of optional items that allow enhancing and matching
the equipment's performance to the client's needs. See the description of each of
these items:
6.1 Pictogram kit
The pictogram kit visually signals the direction of passage (green arrows) or the
passage blocking (red X).

6.2 Electric counter kit
The electric counter kit for pulses and turns is digital presents six digits and was
developed for access control applications that use the C Fit turnstile, and can also beatrax
used in other projects that require such device. The location of the counter in the
equipment (side gap) is the same as the mechanical counter.
The electronic counter has inputs for two sensors, which allows its configuration for
sequential sensing, enabling it to detect turns of the turnstile only for one direction or the
other. This device also offers the possibility of counting simple pulses (like the other
counters available in the market).
The Digicon electronic counter works through a key (button) that allows access to all its
functions. Optionally, there is the possibility of the installation of an additional key on the
front panel, activated by switch.
Key
Signal Name/description
CN1
1 Ground wire
2 Input sensor 1
3 Input sensor 2
CN2
1 External supply of 5 Vcc (battery eliminator)
2 Ground wire
3 Input for clearance key of frontal key
CN3
1 Ground wire
2 Powered by batteries of 3 Vdc (two AA batteries of
1.5 Vdc)
Signal Name/description
CN1
1 Ground wire
2 Input sensor 1
3 Input sensor 2
CN2
1 External supply of 5 V (battery eliminator)
2 Ground wire
3 Input for clearance key of frontal key
CN3
1 Ground wire
2 Powered by batteries of 3 V (two AA batteries of 1.5
V)

The device also presents two independent totalizer accumulators, one total and one
partial; only the latter can be reset during normal functioning.
To shift visualization of the counter kit between total and partial totalizers, just press
the key and release it in a short period. To identify which totalizer is being displayed,
the indication totAL or PArtial appears on screen, as well as a point on the right lower
edge for the partial totalizer and a point on the left lower edge for the total.
Visualization of partial counter
Visualization of total counter
Resetting the partial totalizer
To reset the partial totalizer, it is necessary to access the partial visualization mode
and then press the function key for about 3 seconds (or until all the digits are zero).
Configuration of operation mode:
The counter can be configured to count pulses or turns clockwise or counter
clockwise (the denomination “clockwise”and “clockwise”only serves tocounter
distinguish the two tuning directions). To configure the counter, it is necessary to
access the total visualization mode and proceed as shown:
Sensors:
The sensors must connect the sensor's input to the counter's ground wire (switches,
optical couplers, buttons, relays, etc.).

Power characteristics
External dimensions
6.3 Power supply
This power supply was especially designed for the line C . Among the mainatrax
advantages of this optional item, is its adaptation capability to the voltage
variations often found in installation sites –the input voltage can vary between
100 and 240 V .ac
The supply's specific technical features, protections and dimensions were
carefully tested and approved in hostile temperature and environmental
conditions, which ensures the adequate power supply to the equipment's
performance. Besides the input and output voltages indicated in the image
below, the supply has a short-circuit and overheating protection.
Power 2 AA batteries (3V)
5V battery eliminator
Battery life 1.5 year or over 3,000,000 cycles (alkaline
batteries, with sensors and open buttons)
Number of digits 6
Period of data
retention
1 min 30 secs (to replace batteries without
losing count)
Digits size 8 x 4 mm (height x width)
Output:
Input:
Ground
Neutral
Phase
TIP: The power supply can be mounted to the board's support that
accompanies CATRAX Fit.
100 A 240Vac

6.4 Control board
C Fit's control board was designed to meet most technologies of access controlatrax
terminals in the market. The controller have mechanical features and layout perfectly
suited for the C Fit's needs and it is one of the best options for the equipment'satrax
operation.
The following image shows the control board with its straps, connectors, and dipswitch.
The table below describes the functions of the control board's connectors:

Signal Name/description
CN1 Inputs
1 (+) vext 1 (enables turn through voltage)
2 HAB1 (from right to left)
3 GND
4 Vext2 (enables turn through voltage)
5HAB2 (enables turn through dry contact –from
left to right)
6 GND
7(+) 12Vdc (available to auxiliary –maximum 500
mA)
8 CLOCK1 (input for reader from left to right)
9 DATA1 (input for reader from left to right)
10 CLOCK2 (input for reader from right to left)
11 DATA2 (input for reader from right to left)
12 GND
CN2 OUTPUTS
1 NO or NC Contact (HAB1 return)
2 Contact C (HAB1 return)
3 NO or NC Contact (HAB2 return)
4 Contact C (HAB2 return)
5Output for indicative X (open collector NPN –
maximum 500 mA) orange wire
6Output for arrow > (open collector NPN –
maximum 500 mA) blue wire
7Output for arrow < (open collector NPN –
maximum 500 mA) green wire
8 (+) 24 Vdc (indicative arrows’power) red wire
9 GND (indicative arrows’power) black wire
10 (+) solenoid of badge collector box

CN3 POWER –POWER INPUT
1 Power input +12Vac
2 Power input GND
3 GND
CN4 BOX SENSOR
1 LED anode
2 Box signal
3 GND
4 GND
CN5 ELECTROMAGNETS
(+) electromagnet 1
(-) electromagnet 1
(+) electromagnet 2
(-) electromagnet 2
CN6 OPTICAL SENSORS
Sensor 1 signal
LED 1 anode
Sensor 2 signal
GND
LED 2 anode
INFORMATION: The cables of the optical sensors (CN6) and the
electromagnets (CN5) are provided alongside C Fit.atrax
19

6.4.1 Inputs
The input signals or passage clearance (HAB1 and HAB2) can be originated by relay
contact, pushbutton contact, tension from 5 to 24 Va / c, from 110 to 220 V / c.c d ac d
To enable passage through relay contact or pushbutton, make the connection as
shown below:
Enabling passage through tension pulse is shown in the image below. It is necessary
to observe the polarity of the Vcc voltages and to use an external resistor for high
voltages (110V and 220V).
NO or NC contact
5 to 24
Vac or Vdc
110 to 220
Vac or Vdc
20
Table of contents