7
QUICK REFERENCE GUIDE
Programming
Number Page Description of Task Factory
Setting
Programming
Procedure
81 41 Add or Edit a Full
Function Card 81 # (card PIN code) # (facility code) (card type, 26 or
30) # (schedule for door 1, 0-63) # (schedule for door 2,
0-63) # (schedule for door 3, 0-63) # (schedule for door
4, 0-63) #
82 41 Add a Group of Cards
at Once 82 # (card PIN code start range) # (card PIN code end
range) # (facility code) # (card type, 26 or 30) #
(0=deactivate, 1=activate) # (schedule for door 1, 0-63)
# (schedule for door 2, 0-63) # (schedule for door 3,
0-63) # (schedule for door 4, 0-63) # name (0-20
characters) #
87 42 Activate or Deactivate
a Card 87 # (card PIN code) # (facility code) # (card type, 6 or
30) # (0=deactivate; 1=activate) # (0=don’t use start;
1=use start) # (Start Date=yymmdd) # (Start Time=hhmm)
# (0=don’t use end; 1=use end) # (End Date=yymmdd) #
(End Time=hhmm) #
88 42 Delete a Card 88 # (card PIN code) # (facility code) # (card type, 26 or
30) #
90 45 Add a Basic
Transmitter 90 # (transmitter PIN code) # (facility code) # (sequence
number) # (ID number) # (button number) #
91 46 Add or Edit a Full
Function Transmitter All Doors=
1 Full
Access
91 (transmitter PIN code) # (facility code) # sequence
number) # (ID number) # (button number) # (schedule
for door 1, 0-63) # (schedule for door 2, 0-63) #
(schedule for door 3, 0-63) # (schedule for door 4, 0-63)
#
94 46 Add or Edit a Group of
Full Function
Transmitters
94 # (transmitter PIN code start range) # (transmitter PIN
code end range) # (facility code) # (sequence number) #
(ID number) # (button number) # (0=deactivate;
1=activate) # (schedule for door 1, 0-63) # (schedule for
door 2, 0-63) # (schedule for door 3, 0-63) # (schedule
for door 4, 0-63) #
95 47 Replace a Lost
Transmitter 95 # (transmitter PIN to change) # (facility code) #
(sequence number) # (ID number) # (button number) #
(new transmitter PIN) # (new facility code) # (new
sequence number) # (new ID number) # (new button
number) #
96 48 Verify a Transmitter 96 # (transmitter PIN code) # (facility code) # (sequence
number) # (ID number) # (button number) #
98 48 Activate or Deactivate
a Transmitter 98 # (transmitter PIN code) # (facility code) # (sequence
number) # (ID number) # (button number) #
(0=deactivate; 1=activate) # (0=don’t use start; 1=use
start) # (Start Date=yymmdd) # (Start Time=hhmm) #
(0=don’t use end; 1=use end) # (End Date=yymmdd) #
(End Time=hhmm) #
100 47 Delete Transmitter 100 # (transmitter number) # (facility code) # (sequence
code) # (ID number) # (button number) #
102 54 Configure “Door Held
Open” Alarm Feature Disabled 102 # (alarm option; 0=disable, 1=enable until relay time
expires, 2=enable until alarm clears) # (relay group, 0000-
1111) # Order of relays is 4321
103 55 Configure “Door
Forced Open” Alarm
Feature
Disabled 103 # (alarm option; 0=disable, 1=enable until relay time
expires, 2=enable until alarm clears) # (relay group, 0000-
1111) # Order of relays is 4321
104 55 Configure “Strikes and
Out” Alarm Feature Disabled 104 # (alarm option; 0=disable, 1=enable until relay time
expires, 2=enable until alarm clears) # (relay group, 0000-
1111) # Order of relays is 4321