digicon dGate User manual

Product Manual


Copyright– Digicon S.A.
Controle Eletrônico para Mecânica – 2016
All rights reserved. No part of this publication may be reproduced, transmitted,
transcribed, stored in a retrieval system, translated into any language or computer language
in any electronic, magnetic, optical, chemical, manual way, or otherwise, without the express
written permission from Digicon S.A.
Code: 069.31.213
Version: 02
This manual was elaborated by: Digicon S.A. Controle Eletrônico para Mecânica
Documentation Sector - EDS

Contents
05
06
06
07
08
09
09
10
10
13
14
14
16
17
17
19
19
20
21
22
22
23
24
24
25
25
26
26
28
29
1. Important instructions ...................................................................................
2. Orientation ...................................................................................................
3. Introduction .................................................................................................
4. Features of dGate..........................................................................................
4.1.Block dGate operation ..................................................................................
5. Installation and assembly ...............................................................................
5.1.Unboxing....................................................................................................
5.2.Preparing for fixing ......................................................................................
5.3.Fixing to the floor ........................................................................................
5.4.Access to dGate after assembly .....................................................................
6.Power connection ...........................................................................................
6.1.Connections between cabinets .......................................................................
6.2.Electric panel ..............................................................................................
6.3.Electric power and logic supply......................................................................
6.4 ....................................................................................................Interface
7. Optional items ..............................................................................................
7.1.Collecting box kit.........................................................................................
7.2.Pictograms .................................................................................................
7.3.Display.......................................................................................................
8. Sensors .......................................................................................................
8.1 barriers of sensors.......................................................................................
9.Anti-panic .....................................................................................................
10.Maintenance ...............................................................................................
10.1.Door ........................................................................................................
10.2.Equipment cleaning....................................................................................
10.3 Defects and possible causes ........................................................................
11. Technical characteristics ..............................................................................
11.1 Dimensions ...............................................................................................
11.2 Other information ......................................................................................
12. Warranty and technical assistance .................................................................

1. Important instructions
You can see, below, the symbols that will appear in this manual, signaling important
moments. It is essential to pay attention to them.
TIP: Indicates something Digicon considers important.
CAUTION: Indicates a moment of extreme caution when
handling the equipment/product.
ATTENTION: Indicates a moment when your observation
skills should be extremely productive.
INFORMATION: Presents interesting facts about the
purchased product.
QR CODE: Presents additional information or links
with more details about the presented text.
05

06
Read the information and instructions of this manual carefully, before using the
product. This ensures the correct use of the equipment and maximum use of its
technical features as well as a prolonged service life.
This product does not present sealing against the rain, that is, it is designed to
be used indoors.
Keep this manual for future consultations.
Digicon reserves its right to its products at any moment to adapt themchange
to more recent technical advancements.
Digicon maintains its right to the information contained in this manualchange
without previous notice.
Digicon does not provide any contractual warranty concerning the information
in this manual, and cannot be held responsible for errors it may contain and
problems due to its use.
The information contained in this manual is exclusive property of Digicon and is
protected by copyright laws.
This manual cannot be reproduced, photocopied or translated, in its entirety or
in part, into any kind of medium, without Digicon's written consent.
2. Orientations
3. Introduction
When innovation meets and design meets reliability, you meet the bestrobustness
access control solution. Digicon presents a solution thought out in the smallest details
to bring innovation, quality, and design to the access control market. dGate is born as
the results of an intense process of research in world tendencies and a thorough
engineering work.

07
4. Features of block dGate
The access control system dGate has a motorized system for opening and closing
access doors activated after identification and authorization of user access. A system
of sensors is used to identify and avoid passage of non-authorized people – bobbing
attempts.
AISI 304 brushed stainless steel casing manufactured in 2.0mm sheets.
Angel wings and swing gate doors in Tempered Glass or Polycarbonate with 12mm
of thickness.
Side doors open via key with secret – they open to the block's interior and facilitate
access to configuration and maintenance.
Specific micro processed controller allows accelerating and decelerating the door's
movement, optimizing passage flow.
motorHigh-performance dPower with door opening in 0.7 seconds, silent and with
encoder for precise positioning.
Indicators for visual and sound alarms.
Detection system: 8 infrared sensors to detect passage plus 2 safety sensors
(the model has 2 extra sensors).PNE
Anti-crushing system: the doors open when they detect an obstacle.
Anti-fraud system with sound alarm and bobbing detection (user in opposite
direction and invalidated passage attempt).
Direction control: allows bidirectional operation – can be configured to work in
different passage directions.
Emergency opening: automatic opening in case of power failure or activation of
energy alarm.
Internal space specific for integrating the access controller.
Full range supply (from 90 to 240 Vca).power
version with doors closedConsumption of 25W (in the 500mm ).
U RGBpper pictogram (operation) with high-brightness leds, with individual
control for each color.
F RGBrontal pictogram (orientation) with leds, with individual brightness control
for each color.
moto.Dedicated microcontroller for controlling the
High-durability Brushless engine.
Door positioning control monitored by a magnet encoder (no wear since it is
magnetic).

4.1 dGate operation
dGate access controller has a motorized system for opening and closing the access
doors, which is activated after the identification and authorization of user access
(access controller board is required. Ex.: board).MCA
A system of sensors is used to identify and avoid the passage of non-authorized people
or bobbing attempts.
dGate uses the exclusive dPower , completely developed by Digicon with patentmotor
technology.
dPower allows controlled, smooth, silent, and comfortable turning for the user.
Some engine characteristics:
Robust;
Reliable;
High performance;
Electronicontrol;
Silent.
The equipment has an operation mechanism activated by a permanent-magnets
engine, brushless type. The motor set is activated by direct current converted through
the activation of signals for later activation of the coil set.PWM
The engine is brushless-type, which is, the use of direct-current engines that use coal
as elements of its commuting system of magnet field is not accepted.
The equipment's activating mechanism (permanent-magnets brushless-type engine)
must be sealed and made of robust casing, with heat dissipation via natural or forced
convection; its mechanical elements, subject to supporting efforts, must be
permanently lubricated.
Voltage: 24Vdc
Power: 60W
Tork: 6,96Nm
Torque: <45dB
08
Motor SW
(swing gate)
Motor AW
(angel wing)
Voltage: 24 Vdc
Power: 72W
Tork: 17Nm
Torque: <20dB

5.Installation and assembly:
5.1 Unboxing:
As the items inside the package can vary (depending on the client's requests), it is
important to perform a cautious visual inspection before installing and assembling the
turnstile. A checklist that works as a guide during inspection accompanies all Digicon
packages.
09
INFORMATION: The cover is configured according to commercial
combination.
Glass/polycarbonate
door (door-type
optional: or )AW SW
Collecting Box kit inlet
(optional)
Upper cover
(glass or stainless steel)
Orientation
pictogram
Access pictogram
(operation)
Frontal or rear
column
Side doors for accessing
The equipment's
electronics and mechanism
Package
Display
(optional)
SW

5.3 Fixing to the floor
The image below indicates the fixing points on the floor.
The surface must be steady and leveled to ensure good alignment of the sensors.
Fixing can be done through anchor bolts, also known as parabolts, through chemical
fixing.
5.2 Preparation for fixing
Before installing block , check:dGate
1. The place chosen for installing the equipment;
2. If there is a power source or electric socket nearby (ducts for connection).
3. If the place chosen is adequate for the installation of the access controller (indoors).
4. If the floor has conditions to receive anchor bolts (at least 4cm of 15 M.P.A.FCK
concrete or equivalent).
ATTENTION: Once the block dGate installation requires floor drilling, it is
extremely important that the place of installation be chosen carefully.
INFORMATION: Measures of the blocks dGate are illustrated in millimeters
and (Inches).
TIP: To fasten the screws, use a tool with a long extensor.
-Fixing points
10
Optional fixing points
70 (2.755")
1309(51.535")
1416(55.748")
159 (6.259")
320(12.598")
320(12.598")
130(5.118")
130(5.118")
240(9.448")
Ø15(0.590")
90
(3.543")
84
(3.307")
220(8.661") 220(8.661") 220(8.661")

11
With the holes for fixing the turnstile done, install the fixing tie rods according to the
image below. Digicon recommends using a capsule chemical anchorage by Hilti
( ).www.hilti.com.br
Step by step:
1. Using a 12mm drill, make a hole 90mm deep (tie rods M10).
2. Clean the hole with a blower or aspirator to remove the dust residue.
3. Place the tie rod inside the hole and measure the depth. The tie rod has a mark
that must remain parallel to the ground.
4. Place the capsule inside the hole.HVU

5. Secure the tie rod in the drill and screw it in until it reaches the bottom of the hole or
until the mark in the rod is leveled with the ground.
6. Apply the drill until the chemical material reaches the surface.
7. do not touch the tie rod to allow the chemical reaction (10 min).
8. curing time indicated in the table:
9.Tightening torque and other information can be seen in the following table:
12
Temperature of base material
Temperature of base materialCuring time necessary
until the fixing is able to receive the total load tcure
20°C to 40°C
20 min
10°C to 19°
30 min
0° to 9°C
1 h
-5°C to -1°C
5 h
Data according to the -05/0255/0256/0257, edition 2010-03-01 / 2006-01-20ETA

Resistences of calculation must be reduced for distances from the edge and spacing smaller than
the critical values.
a) h: base material thickness
b) This is the maximum tightening torque recommended to avoid rupture through cracking during
installation for fixings with minimal distance from the edge and/or spacing.
5.4 Access to block dGate after assembly:
After the block dGate is installed and assembled, access to the interior of the
equipment can be done with the key that accompanies the equipment, in two ways:
Via the door that grants access to the electric panel;
Via the door that grants access to the engine or some accessory that is added, such
as the collecting box kit.
13
Locks
Electric panel door
Access door to
engine and accessories
Additional panel
for assembly of
inegrator’s access
controller
230x350mm
Additional panel
for assemblyof
(optional) orMCA
for the integrator’s
access controller
180x205mm

6.Power connection
14
1416(55.748")
188(7.401")
220(8.661")
598(23.543")
220(8.661")
45(1.771)
70(2.755")
298(11.732")
708(27.874")
160(6.299")
Embedded boxes
6.1 Interconnection of blocks
Below, you can see a template of the measures for installation of the embedded boxes,
which are installed before the block. There are two openings under the block, one on the
right and another one on the left, inside which the embedded boxes should be.
Conduits of
50 mm of diameter
920
520
520
Power network
Data cable
Power
network
cable
Interconnection
boxes
PASSAGE BOXES
Entry
Exit
Block seen from below:
4"x4"
INFORMATION:
The measures of block dGate are illustratein and (Inches),
I PNEn model, the block body measures 360mm of width.
80(3.149")

TIP: Separate the power network from the logic network.
15
INFORMATION:
Measures of block dGate are illustrated in millimeters.
There are three interconnection possibilities for the blocks: right side,
left side, and center.
The colors of the cables are illustrative only. The distance between the
passage boxes vary according to the block size.
Basic cabling:
037.12.352 - Power cable sensors barrier Transmitter
037.12.355 - Power cable solenoid BOX
037.12.356 - Power cable Motor 2AC
037.12.357 - Communication cable 485 Motor 2RS
037.12.358 - Cable collecting box sensor
PNE:
037.12.445 - Interconnection cable between blocks
INFORMATION:
Digicon offers 5-meter long interconnection cables.
The depth of the ducts must be measured so that the cables are long enough.

16
6.2 Electric panel
The electric panel presents the (Passage control Module), supplies (12Vcc), andMCP
control (Central processing unit). If the integrator requires more space, the blockCPU
has another area destined for it. In this area, there are the connections of the passage
sensors and power.
CAUTION: Risk of electric shock on the panel.
Panel
MCA
(optional)
Board
MCP
Borne Supply
Set

17
6.3 Electric power and logic supply:
The block dGate is fed with tension from to 240 Vca. Digicon recommends the90
regulation 5410 as reference to the equipment's electrical connections. In one ofNBR
its columns, the turnstile has a borne where the power cables (electrical supply) and the
ground wire must be connected.
6.4 Block interfacing
P
N
G
Born Set 02
Borne Set 01
- for connecting
electric and logic
network
Logic network
(used when the
turntile has board).
Borne 01 to borne 14
Borne 15 to borne 28
Borne 29 to borne 42

NA
NA NA
NA
UUUUU UUUUU
NF NF
CC
Input
Input
Output
Output
(Integrator’s controlboard)
( )Panel's inner circuit
CC
NA
UUUUU
NF
(Integrator’s controlboard)
Switch
18
12345678910 11 12 1314
Enabling passage through dry contact (input):
Connection borne 02 borne 01
Switch (input):
Connection borne 02 borne 02 (optional)
Allows keeping block open leaving
The passage free in both directions
Confirmation of passage through dry
contact (output):
Connection borne 02 borne 15

7.Optional items
dGate is compatible with most access control technologies in the market today;
however, Digicon offers a range of optional items that allow enhancing and matching
the equipment's performance to the client's needs. See the description of each of
these items:
The collecting box kit has a device for collecting, retaining, and gathering cards or
badges. It is ideal for places with eventual visitors or users. The kit is composed of a
socket, a retention device activated by a solenoid, and a storage box.
The image below shows the items that accompany the collecting box kit and can
work as a guide for its assembly:
19
7.1 Collecting box kit
Box
Inlet
Collecting safe
Collecting box kit

7.2 Pictograms
The block has two pictograms: Orientation and operation, the frontal pictogramdGate
(orientation) is integrated to the upper pictogram (operation) without electric
connection.
Operation pictogram (upper):
The operation pictogram is installed on the upper part of the equipment and is
represented by a red arrow and by a green arrow.
The red blinking pictogram, in both sides, means passage not allowed.
The green pictogram flows indicating direction means passage allowed.
Orientation pictogram (frontal):
The orientation pictogram is installed on the edges of the equipment and is also
represented by red and green arrows.
The red pictogram informs the user that the block dGate is not operating in that direction
or that, at the time, passage is not allowed.
The green pictogram informs the user the direction in which block dGate is operating.
20
Pictogram Pictogram
Direction ollowed or danied,
for example, when a user
clears the passage in the
opposite direction, flow is
denied.
Enable or disabled
direction, for example,
blockage can be
configured in only one
direction of passage
(entry only).
Display
Antenna
Table of contents
Other digicon IP Access Controllers manuals