The One-zone Hardwire Module (DGP2-ZX1) is an interface
between the Digiplex (DGP-48) or DigiplexNE (DGP-NE96) control
panels and any hardwired detection devices. The DGP2-ZX1
connects to the Digiplex/DigiplexNE control panels’ communication
network providing you with one additional hardwired input.
INSTALLATION
The DGP2-ZX1 modules are connected to the control panel’s
communication network in a star and/or daisy chain configuration.
The communication network consists of four wires that provide
power and two-way communication between the control panel and
all modules connected to it. Connect the four terminals labeled red,
black, green, and yellow of each DGP2-ZX1 to the corresponding
terminals on the control panel as shown in Figure 1 on the back of
this instruction. Please refer to the appropriate control panel’s
Installation & Reference Manual for maximum allowable installation
distance from the control panel.
ZONECONNECTIONS
Each DGP2-ZX1 has one hardwired input terminal that will allow
you to connect up to two (with ATZ enabled) non-bus detection
devices to the Digiplex/DigiplexNE system. Each device connected
to the DGP2-ZX1’s input terminal must be assigned to a zone in
the control panel and the zone’s parameters must be defined. For
more information, please refer to the appropriate control panel
Installation & Reference Manual. The DGP2-ZX1 will communicate
the status of the zones to the control panel through the
communication network. Connect the devices to the DGP2-ZX1 as
shown in Figure 1 on the back of this sheet.
The DGP2-ZX1 follows the ATZ and EOL definitions set
in the Digiplex/DigiplexNE control panels.
PROGRAMMING METHOD
From any keypad connected to the communication network:
Please note that the serial number is located on the DGP2-ZX1’s
PC board. We recommend that you use the DGP2-ZX1’s
programming sheet found in the Digiplex/DigiplexNE Modules’
Programming Guide to keep track of what was programmed and
how. This module can also be programmed using the control
panel’s Module Broadcast Feature (refer to the appropriate control
panel Installation & Reference Manual) as well as through the
WinLoad Security Management Software (refer to the WinLoad
Software Help File for more information).
The DGP2-ZX1 comes equipped with an on-board tamper switch.
When option [1] is enabled in section [001] and the tamper switch
is triggered, a Module Tamper report will be sent to the control
panel via the communication network.
INPUTSPEEDTIMINGS
The input speed defines how quickly the input terminal on the
DGP2-ZX1 responds to an open zone. The control panel will only
respond if the zone remains open for the duration of the Input
Speed. All other zone definitions and options don’t come into effect
until the control panel has responded. This feature prevents any
momentary glitches from causing an alarm or unnecessary
reporting.
Input Speed = Base Time x Time Value.
This section determines the unit of time to be multiplied by the
Time Value.
000 = 15 milliseconds
001 = 1 second
002 = 1 minute
Enter a 3-digit decimal value between 001 and 255. This decimal
value will be multiplied by the Base Time to determine the input
speed. For example, if section [002] = 001 and section[003] = 030,
the Input Speed will be 30 seconds.
SPECIFICATIONS
On-board tamper switch: Yes
Voltage: 9-16 VDC
Current consumption: 28mA maximum
Number of inputs: 1
Number of zones: 1 (2 with ATZ enabled) standard zone
Input speed: 15ms - 255 minutes
Power-up indication: Green LED illuminated
Proper operation: Red LED flashes
Locate indication: Green LED flashes
Communication Fault
Indication: Green and red LEDs flash alternately
Locate deactivation: Press tamper switch
Humidity: 95% maximum
STEP 1: Press and hold the [0] key
STEP 2: Enter the [INSTALLERCODE]
STEP 3: Enter section [953] (DGP-48) / [4003] (DGP-NE96)
STEP 4: Enter the DGP2-ZX1’s 8-digit [SERIALNUMBER]
STEP 5: Enter the 3-digit [SECTION]you want to program
STEP 6: Enter the required data
Section [001] - Option [1]
Tamper Recognition
Section [002]
Base Time
Section [003]
Time Value
All manuals and user guides at all-guides.com
all-guides.com
Figure 1: Connecting the DGP2-ZX1
All manuals and user guides at all-guides.com

Other Digiplex Control Unit manuals

Digiplex DGP2-ZX1 User manual

Digiplex

Digiplex DGP2-ZX1 User manual

Digiplex DGP2-ZC1 User manual

Digiplex

Digiplex DGP2-ZC1 User manual

Digiplex EVO ANC1 User manual

Digiplex

Digiplex EVO ANC1 User manual

Digiplex EVO DGP2-ANC1B User manual

Digiplex

Digiplex EVO DGP2-ANC1B User manual

Popular Control Unit manuals by other brands

Western Electric D1 Installation

Western Electric

Western Electric D1 Installation

Jung 5192KRMTSD Series Product documentation

Jung

Jung 5192KRMTSD Series Product documentation

Cosmo CKPL quick guide

Cosmo

Cosmo CKPL quick guide

DoorBird D21x Series manual

DoorBird

DoorBird D21x Series manual

HPE Synergy 620 Gen9 Dissambly instruction

HPE

HPE Synergy 620 Gen9 Dissambly instruction

Kaco Powador XP Series installation instructions

Kaco

Kaco Powador XP Series installation instructions

EOS InfraStyle Installation Instructions for retailers

EOS

EOS InfraStyle Installation Instructions for retailers

Cosmo CKZM quick guide

Cosmo

Cosmo CKZM quick guide

Intellijel AMPS manual

Intellijel

Intellijel AMPS manual

INVENTIA MT-151 user manual

INVENTIA

INVENTIA MT-151 user manual

Nice TTPRO BD Instructions and warnings for installation and use

Nice

Nice TTPRO BD Instructions and warnings for installation and use

Satel MST-1 manual

Satel

Satel MST-1 manual

Klark Teknik DN32-ADAT quick start guide

Klark Teknik

Klark Teknik DN32-ADAT quick start guide

LEGRAND VM1000 installation instructions

LEGRAND

LEGRAND VM1000 installation instructions

Arbor Technology EmETXe-i87M2 user manual

Arbor Technology

Arbor Technology EmETXe-i87M2 user manual

Lenze L-force SM301 Mounting instructions

Lenze

Lenze L-force SM301 Mounting instructions

RF SOLUTIONS BLE-PB03 user manual

RF SOLUTIONS

RF SOLUTIONS BLE-PB03 user manual

Siemens SIMATIC NET IE/AS-INTERFACE LINK PN IO manual

Siemens

Siemens SIMATIC NET IE/AS-INTERFACE LINK PN IO manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.