Digital Graphic Printer UP-D898MD Guide

Printed in China
Digital Graphic
Printer
ЦИФРОВОЙ
ГРАФИЧЕСКИЙ
ПРИНТЕР
ɐɂɎɊɅɕԔ
ȽɊȺɎɂɄȺɅɕԔ
ɉɊɂɇɌȿɊ
UP-D898MD
4-528-676-01(2)
© 2014 Sony Corporation
ご使用になる前に JP
Before Using this Printer ___ GB
Avant d’utiliser l’imprimante _
FR
Kurzeinführung ___________ DE
Prima dell’utilizzo della stampante_
IT
Antes de utilizar la impresora _
ES
Voordat u de printer gaat gebruiken_
NL
Innan du börjar använda skrivaren _
SE
Antes de utilizar esta impressora_
PT
Inden du bruger denne printer _
DK
Ennen tulostimen käyttöä___ FI
Før du bruker denne skriveren _
NO
Przeczytaj zanim rozpoczniesz pracę z drukarką __
PL
GR
Příručka Před použitím tiskárny_
CZ
Üzembehelyezési kisokos __ HU
Перед использованием принтера _
RU
Înainte de utilizarea acestei imprimante_
RO
Преди използване на този принтер __
BG
Pred použitím tejto tlačiarne_
SK
Pred uporabo tega tiskalnika_
SI
__ EE
_LV
_LT
Prije upotrebe ovog pisača _ HR
___ KR
_KZ
П
р
инте
рд
і пай
д
алан
уд
ы
ң
ал
д
ын
д
а
C:\#Work#\Taniguchi\4528676011\4528676011UPD898MDSY\01JP-UPD898MD\010COV.fm masterpage: Right
UP-D898MD
4-528-676-01(2)
お買い上げいただきありがとうございます。
電気製品は安全のための注意事項を守らないと、
火災や人身事故になることがあります。
この「ご使用になる前に」には、事故を防ぐための重要な注意事項と製品の取
り扱いかたを示してあります。この「ご使用になる前に」をよくお読みのう
え、製品を安全にお使いください。お読みになったあとは、いつでも見られる
ところに必ず保管してください。

JP 2
安全のために
本機は正しく使用すれば事故が起きないように、安全に
は充分配慮して設計されています。しかし、間違った使
いかたをすると、火災や感電などにより死亡や大けがな
ど人身事故につながることがあり、危険です。
事故を防ぐために次のことを必ずお守りください。
安全のための注意事項を守る
3 ~ 9 ページの注意事項をよくお読みください。製品全
般の安全上の注意事項が記されています。
故障したら使わない
すぐに、ソニーのサービス窓口または営業担当者にご連
絡ください。
万一、異常が起きたら
1電源を切ります。
2電源コードや接続ケーブルを抜きます。
3ソニーのサービス窓口または営業担当者までご相談く
ださい。
・ 煙が出たら
・ 異常な音、においがしたら
・ 内部に水、異物が入ったら
・ 製品を落としたり、キャビネットを破損したと
きは
警告表示の意味
取扱説明書および製品では、次のような表示をし
ています。表示の内容をよく理解してから本文を
お読みください。
この表示の注意事項を守らないと、火災・感電な
どにより死亡や大けがなどの人身事故につながる
ことがあります。
この表示の注意事項を守らないと、感電やその他
の事故によりけがをしたり周辺の物品に損害を与
えたりすることがあります。
注意を促す記号
行為を禁止する記号
行為を指示する記号

3JP
警告
下記の注意を守らないと、
火災や感電により死亡や大けがに
つながることがあります。
電源コードを傷つけない
電源コードを傷つけると、火災や感電の原
因となることがあります。
・ 設置時に、製品と壁やラック、棚などの
間に、はさみ込まない。
・ 電源コードを加工したり、傷つけたりし
ない。
・ 重いものをのせたり、引っ張ったりしな
い。
・ 熱器具に近付けたり、加熱したりしない。
・ 電源コードを抜くときは、必ずプラグを
もって抜く。
万一、電源コードが傷んだら、ソニーの
サービス窓口または営業担当者に交換をご
依頼ください。
内部に水や異物を入れない
水や異物が入ると火災や感電の原因となる
ことがあります。
万一、水や異物が入ったときは、すぐに電
源を切り、電源コードや接続ケーブルを抜
いて、ソニーのサービス窓口または営業担
当者にご相談ください。
分解や改造をしない
分解や改造をすると、火災や感電、けがの
原因となることがあります。
内部の点検や修理は、ソニーのサービス窓
口または営業担当者にご依頼ください
雨のあたる場所や、油煙、湯気、湿
気、ほこりの多い場所には設置しな
い
上記のような場所やこの取扱説明書に記さ
れている使用条件以外の環境に設置すると、
火災や感電の原因となることがあります。
火災 感電
警告
移動の際は電源コードや接続ケーブ
ルを抜く
コード類を接続したまま本機を移動させる
と、コードに傷がついて火災や感電の原因
となることがあります。
表示された電源電圧で使用する
製品の表示と異なる電源電圧で使用すると、
火災や感電の原因となります。
日本国内では 100 V でお使いください。
水にぬれる場所で使用しない
水ぬれすると、漏電による感電発火の原因
となることがあります。
JP

JP 4注意
下記の注意を守らないと、
けがをしたり周辺の物品に損害を与える
ことがあります
安全アースを接続する
安全アースを接続しないと、感電の原因と
なることがあります。
付属の電源コードを使用することで安全
アースが接続されます。
3極 t 2 極変換プラグは使用しないでくだ
さい。
不安定な場所に設置しない
ぐらついた台の上や傾いたところに設置す
ると、倒れたり落ちたりしてけがの原因と
なることがあります。また、設置・取り付
け場所の強度を充分にお確かめください。
ぬれた手で電源プラグをさわらない
ぬれた手で電源プラグを抜き差しすると、
感電の原因となることがあります。
付属の電源コードを使う
付属の電源コードを使わないと、火災や感
電の原因となることがあります。
製品の上に乗らない、重いものを乗
せない
倒れたり、落ちたり、壊れたりして、けが
の原因となることがあります。
コード類は正しく配置する
電源コードや接続ケーブルは、足に引っか
けると本機の落下や転倒などによりけがの
原因となることがあります。
充分注意して接続・配置してください。
電源コードのプラグ及びコネクター
は突き当たるまで差し込む
真っ直ぐに突き当たるまで差し込まないと、
火災や感電の原因となります。
注意
カッターの刃には触れない
カッターの刃に触れると、けがをすること
があります。
通風孔をふさがない
通風孔をふさぐと内部に熱がこもり、火災
や故障の原因となることがあります。風通
しをよくするために次の項目をお守りくだ
さい。
・ 壁から 10cm 以上離して設置する。
・ 密閉された狭い場所に押し込めない。
・ 毛足の長い敷物(じゅうたんや布団など)
の上に設置しない。
・ 布などで包まない。
・ あお向けや横倒し、逆さまにしない。
ドアパネルの上に指を置かない
ドアパネルを閉める際はドアパネルの上に
指を置かないでください。
フロントパネルとの間に挟んでけがの原因
となることがあります。
お手入れの際は、電源を切って電源
プラグを抜く
電源を接続したままお手入れをすると、感
電の原因となることがあります。
プリント直後サーマルヘッドに触れ
ない
プリント直後は、サーマルヘッドが熱く
なっている場合があり、触れるとやけどの
原因となることがあります。
プラテンローラーを連続回転させな
がらクリーニングしない
プラテンローラーをクリーニングする際は
プラテンローラーを連続回転させながらク
リーニングしないでください。ドアパネル
との間に指を挟んでけがの原因となること
があります。
プラテンローラーの回転中に手のひ
らをプラテンローラーに近づけない
プラテンローラーを連続回転させた状態で
クリーニングなどを行うと、手のひらが挟
み込まれてけがをする可能性があります。

5JP
注意
医療環境で使用するための重要なお
知らせ
1. 本機に接続する全ての機器は、安全規格の
IEC60601-1、IEC60950-1、IEC60065、あるい
は機器に適用できる他の IEC/ISO 規格等に従って承
認または適合しているものをご使用ください。
2. さらにシステム全体として IEC60601-1-1 規格に適
合していなければなりません。信号入力部分あるいは
信号出力部分に接続する全ての周辺機器が医療用のシ
ステムとして構成されるため、システム全体として
IEC60601-1-1 の規格要求に適合する責任がありま
す。疑義がある場合には、ソニーの営業担当にご相談
ください。
3. 他の機器と接続すると、漏れ電流を増加させる可能性
があります。
4. この特定の機器のために、すべての周辺機器は上記の
ように接続し、IEC60601-1 の構造要求と最小基礎
絶縁を備えている追加した絶縁トランス経由で商用電
源に接続してください。
5. この機器は無線周波エネルギーを発生、利用してお
り、周囲に放射する可能性があります。取扱説明書に
従って設置、使用されない場合、他の機器に対して電
磁波障害を引き起こすかも知れません。この機器が電
磁波障害を起こす場合は(この機器から電源コードの
プラグを抜くことにより確認できます)、以下の方法
を試してください。
電磁波障害を受けている機器に対して、この機器を移
動してください。この機器と電磁波障害を受けている
機器を異なる電源系統のコンセントに接続してくださ
い。
ソニーの営業担当にご相談ください。
(適合規格:IEC60601-1-2 と CISPR11、Class B、
Group1)

JP 6注意
医療環境で使用するための EMC に
関する重要なお知らせ
・ UP-D898MD は、EMC に関して特に注意する必要が
あり、取扱説明書で提供される EMC 情報に従って設置
及び使用する必要があります。
・ UP-D898MD は、携帯電話のような、携帯型及び移動
型の無線通信機器に影響を受けることがあります。
ソニー株式会社によって指定されたもの以外のアクセサ
リーやケーブルを使用すると、UP-D898MD のエミッ
ション(電磁妨害の放射)増加やイミュニティ(電磁妨
害の耐性)低下を招くことがあります。
UP-D898MD を他の機器と隣接または積み重ねて使用す
る場合には、その使用構成で正常に動作していることを
確認する必要があります。
警告
指針及び製造業者の宣言-電磁エミッション
UP-D898MD は、下記の電磁環境で使用することを前提としています。
UP-D898MD のお客様または使用者は、下記の環境で使用することを確認してください。
エミッション試験 適合性 電磁環境-指針
無線周波エミッション
CISPR 11
グループ 1
UP-D898MD は、内部機能のためだけに無線周波エネルギーを使用
しています。そのため、無線周波エミッションは非常に低く、近傍の
電子機器を妨害することは、ほぼありません。
無線周波エミッション
CISPR 11
クラス B
UP-D898MD は、家庭及び家庭用に使用される建物に給電する公共
の低電圧配電網に直接接続されている建造物を含むすべての建造物で
の使用に適しています。
電源高調波エミッション
IEC 61000-3-2
クラス A
電圧変動 / フリッカ エミッ
ション
IEC 61000-3-3
適合する
警告

7JP
注意
指針及び製造業者の宣言-電磁イミュニティ
UP-D898MD は、下記の電磁環境での使用を意図しています。UP-D898MD のお客様または使用者は、下記の環境で使
用することを確認してください。
イミュニティ試験 IEC 60601
試験レベル 適合性レベル 電磁環境-指針
静電気放電(ESD)
IEC 61000-4-2
±6 kV 接触
±8 kV 気中
±6 kV 接触
±8 kV 気中
床材は木材、コンクリートまたは陶製タ
イルとしてください。床材が合成物質で
覆われている場合、相対湿度が、少なく
とも 30%以上であることを条件としま
す。
電気的ファストトラ
ンジェント(高速過
渡現象)/ バースト
IEC 61000-4-4
± 2 kV 対電源線
± 1 kV 対入出力線
± 2 kV 対電源線
± 1 kV 対入出力線
電源の品質は、典型的な商用または病院
環境のものを利用してください。
サージ
IEC 61000-4-5
± 1 kV 差動モード
± 2 kV コモンモード
± 1 kV 差動モード
± 2 kV コモンモード
電源の品質は、典型的な商用または病院
環境のものを利用してください。
電源入力ラインでの
電圧ディップ、瞬停、
および電圧変動
IEC 61000-4-11
<5% UT
(>95% ディップ、UT時)
0.5 サイクルの間
40% UT
(60% ディップ、UT時)
5 サイクルの間
70% UT
(30% ディップ、UT時)
25 サイクルの間
<5% UT
(>95% ディップ、UT時)
5 秒間
<5% UT
(>95% ディップ、UT時)
0.5 サイクルの間
40% UT
(60% ディップ、UT時)
5 サイクルの間
70% UT
(30% ディップ、UT時)
25 サイクルの間
<5% UT
(>95% ディップ、UT時)
5 秒間
電源の品質は、典型的な商用または病院
環境のものを利用してください。
UP-D898MD の使用者が、停電中も継続
して運用することが必要な場合は、無停
電電源装置又はバッテリーから UP-
D898MD に電源供給することを推奨し
ます。
電源周波数
(50/60 Hz)
磁界
IEC 61000-4-8
3 A/m 3 A/m 電源周波数磁界は、典型的な商用または
病院環境内の典型的な場所での特性レベ
ルである必要があります。
備考 : UTは、試験レベルを加える前の機器の定格電源電圧である。

JP 8注意
指針及び製造業者の宣言-電磁イミュニティ
UP-D898MD は、下記の電磁環境での使用を意図しています。UP-D898MD のお客様または使用者は、下記の環境で使
用されることを確認してください。
イミュニティ試験 IEC 60601
試験レベル 適合性レベル 電磁環境-指針
伝導性妨害
IEC 61000-4-6
放射無線周波電磁界
IEC 61000-4-3
3 Vrms
150 kHz ~ 80 MHz
3 V/m
80 MHz ~ 2.5 GHz
3 Vrms
3 V/m
携帯型及び移動型の無線通信機器は、ケーブルを
含む UP-D898MD のどの部分に対しても、無線
通信機器の周波数に対応した式から計算された推
奨分離距離以下に近づけて使用しないでくださ
い。
推奨分離距離
d = 1.2 √P
d = 1.2 √P 80 MHz ~ 800 MHz
d = 2.3 √P 800 MHz ~ 2.5 GHz
P は、無線通信機器のメーカーが公表した最大出
力定格(単位はワット(W))で、d は推奨距離
(単位はメートル(m))です。
電磁環境の現地調査によって得られる固定の無線
送信機からの電磁界強度 aは、各周波数範囲 b に
おいて適合レベル未満である必要があります。
下記の記号が表示された機器の近くでは、妨害が
生じる可能性があります。
備考 1: 80 MHz 及び 800 MHz においては、高い方の周波数範囲を適用します。
備考 2: これらのガイドラインでは、対応できない場合もあります。
電磁波伝搬は、建物、物体および人体による吸収や反射の影響を受けます。
a 無線(携帯 / コードレス)電話及び陸上移動無線のための基地局、アマチュア無線、 AM 及び FM ラジオ放送並びに TV
放送のような固定の送信機からの電磁界強度は、理論上、正確に予測することはできません。固定の無線送信機による
電磁環境を評価する為には、電磁波の現地調査の検討が必要です。UP-D898MD が使用される場所で測定された電磁
界強度が、対応する無線の適合レベルを超える場合、UP-D898MD が、正常に動作していることを確認してください。
もし異常な動作が観測される場合、 UP-D898MD の向きや場所を変えるといった追加措置が必要となることがありま
す。
b 周波数範囲が 150 kHz ~ 80 MHz において、電界強度は 3 V/m 未満である必要があります。

9JP
注意
注意
本製品またはアクセサリーを廃棄するときは、関連した
地域または国の法律、および関連した病院の規則にした
がって実施されなければなりません。
警告
主電源を切断するには、電源プラグを抜いてください。
設置の際には、容易にアクセスできる固定配線内に専用
遮断装置を設けるか、使用中に容易に抜き差しできる、
機器に近いコンセントに電源プラグを接続してください。
電源プラグを抜くことが困難な場所に ME 機器を設置し
ないでください。
万一、異常が起きた際には、専用遮断装置を切るか、電
源プラグを抜いてください。
この機器のコネクターは絶縁されておりません。
ご使用にあたっては、IEC60601-1 に適合した機器以外
の接続は禁止します。
交流電源で動作する IT 機器や AV 機器を接続されると、
接続した機器から漏洩電流が流入し、患者や操作者に対
して感電の危険があります。
やむを得ずご使用になる場合は、IT 機器や AV 機器側の
電源に絶縁トランスを接続して絶縁を行うか、接続ケー
ブル間にアイソレーターを接続し絶縁を行う事により、
システムとして IEC60601-1 に適合出来るレベルに感電
のリスクが充分低減されている事を確認してからご使用
下さい。
携帯型及び移動型の無線通信機器と、UP-D898MD との間の推奨分離距離
UP-D898MD は、無線妨害放射が制御されている電磁環境内で使用することを前提としています。UP-D898MD のお客
様または使用者は、携帯型及び移動型無線通信機器(送信機)と UP-D898MD との間の分離距離を保つことによって、
電磁妨害を防ぐことができます。推奨の分離距離は、送信機器の最大出力によって、下記の通りです。
送信機の最大定格出力
W
送信機の周波数による分離距離
m
150 kHz ~ 80 MHz
d = 1.2 √P
80 MHz ~ 800 MHz
d = 1.2 √P
800 MHz ~ 2.5 GHz
d = 2.3 √P
0.01 0.12 0.12 0.23
0.1 0.38 0.38 0.73
11.21.22.3
10 3.8 3.8 7.3
100 12 12 23
最大定格出力が上記にリストされていない送信機器については、送信機器のメーカーが公表する最大出力定格を P(単
位:ワット(W))として、周波数に対応する式を使用して推奨分離距離 d(単位:メートル(m))を計算できます。
備考 1: 80 MHz 及び 800 MHz においては、高い方の周波数範囲に対する分離距離を適用します。
備考 2: これらのガイドラインでは対応できない場合もあります。
電磁波伝搬は、建物、物体および人体による吸収や反射の影響を受けます。
グラフィックシンボルの説明
一般的な警告標識
本機にこのマークがある箇所は、本取扱説明
書の警告文にしたがってご使用ください。
注記 背景色: 黄
三角形のバンド: 黒
シンボル: 黒
取扱説明書参照
本機にこのマークがある箇所は、本取扱説明
書の指示にしたがってご使用ください。
このシンボルは製造業者を表し、隣接して製
造業者名と住所が併記されます。
このシンボルは、欧州共同体における代表者
を表し、隣接して欧州共同体における代表者
の名称と住所が併記されます。
このシンボルは、システムの各部分を同じ電
位にするための、等電位端子を示しています。
警告

JP 10 CD-ROM マニュアルの使いかた
本機には、ペーパーカッターが装備されてい
ます。プリンター用紙を取り付ける際、カッ
ター部に触れるとけがの原因となることがあ
ります。充分ご注意ください。
プリンター用紙トレイの奥側に指を差し込ま
ないでください。隙間に指を挟んでけがをす
る恐れがあります。
機器内部の回路と患者を同時にさわらないでください。
本機の故障時に患者に悪影響を与える電圧が発生する可
能性があります。
CD-ROM マニュアルの
使いかた
付属の CD-ROM には UP-D898MD の取扱説明書が記録
されています。
(日本語、英語、フランス語、ドイツ語、イタリア語、ス
ペイン語、オランダ語、スウェーデン語、ポルトガル語、
デンマーク語、フィンランド語、ノルウェー語、ポーラ
ンド語、ギリシャ語、チェコ語、ハンガリー語、ロシア
語、ルーマニア語、ブルガリア語、スロバキア語、スロ
ベニア語、エストニア語、ラトビア語、リトアニア語、
クロアチア語、韓国語、カザフ語)
この取扱説明書は PDF (Portable Document Format)
ファイルで作成されています。
準備
付属の CD-ROM に収納されているオペレーションマニュ
アルを使用するためには、以下のソフトウェアがコン
ピューターにインストールされている必要があります。
・ Adobe Reader X 以上
Adobe Reader がインストールされていない場合は、下
記 URL よりダウンロードできます。
http://www.adobe.com/jp/
Adobe および Adobe Reader は、Adobe Systems Incorporated
(アドビシステムズ社)の商標です。
取扱説明書を読むには
CD-ROM に収納されている取扱説明書を読むには、次の
ようにします。
1
CD-ROM を、CD-ROM ドライブに入れます。
2
Instructions For Use フォルダ内の、読みたい言語
の取扱説明書を選択します。
Adobe Reader のバージョンによって、ファイルが正し
く表示されないことがあります。正しく表示されない場
合は、「準備」の項の URL より最新のソフトウェアをダ
ウンロードしてください。
注意
注意
注意
メモ
メモ

11 JP
主な仕様
ご注意
CD-ROM が破損または紛失したため、新しい CD-ROM
をご希望の場合は、お買い上げ店、またはセールス会社
窓口のしおり(付属)にあるソニーのご相談窓口にご依
頼ください。(有料)
主な仕様
電源 AC 100 V、50/60 Hz
入力電流 1.3 A
動作環境 温度:5 ℃~ 40 ℃
湿度:20% ~ 80%
気圧:700 hPa ~ 1,060 hPa
輸送保存環境時
温度:- 20 ℃~ + 60 ℃
湿度:20% ~ 80%
気圧:700 hPa ~ 1,060 hPa
最大外形寸法 154 × 88 × 240 mm(幅 / 高さ / 奥
行き)
質量 2.5 kg(本体のみ)
感熱ヘッド 薄膜サーマルヘッド 1280 ドット
階調数 256 階調(8 ビット)
メモリー容量 4096 × 1280 × 8 (bit)
画面寸法 最大 320 × 100 mm
プリント速度 約 1.9 秒 /1 画面(960 × 1280 ドッ
ト時)(メニューの「CONFIG.」t
「-SPEED」で「HI」設定時)
約 3.3 秒 /1 画面(960 × 1280 ドッ
ト時)(メニューの「CONFIG.」t
「-SPEED」で「NOR」設定時)
画素数 最大 4096 × 1280 ドット
画素密度 H:100 mm/1280 ドット= 0.078
mm/ ドット
V:100 mm/1280 ドット= 0.078
mm/ ドット
正方ドット
インターフェース
Hi-Speed USB(USB 2.0 準拠)
付属品 ヘッドクリーニングシート (1)
CD-ROM(プリンタードライバー、取
扱説明書格納)(1)
ご使用になる前に (1)
セールス会社窓口のしおり (1)
電源コード (1)
注意
付属の電源コードは本機の専用品です。
他の機器には使用できません。

JP 12 主な仕様
別売りアクセサリー
プリンター用紙
高濃度プリント用紙 UPP-110HD
光沢プリント用紙 UPP-110HG
白黒プリント用紙 UPP-110S
本機の仕様および外観は、改良のため予告なく変更する
ことがありますが、ご了承ください。
注意
3 極 t 2 極変換プラグはお使いにならないでください。
安全に関する仕様
電撃に対する保護の形式:
クラス I
水の浸入に対する保護等級:
0 級 (特に保護がされていない)
可燃性麻酔剤の点火の危険に対する保護:
空気、酸素または亜酸化窒素と混合
した可燃性麻酔ガスが存在する環境
での使用には適していません。
作動モード:
連続
プリントメディアに関するご注意
再使用禁止
動作不良の原因となり、印刷結果に悪影響を与え
ます。
本機は「高調波電流規格 JIS C 61000-3-2 適合品」で
す。
この装置は、クラス A 情報技術装置です。この装置を家
庭環境で使用すると電波妨害を引き起こすことがありま
す。この場合には使用者が適切な対策を講ずるよう要求
されることがあります。 VCCI-A
・ お使いになる前に、必ず動作確認を行ってください。
本機や付属のソフトウエア、記録メディア、外部スト
レージなどを使用中、万一これらの不具合により正常
に動作しなかった場合のプリント結果や記録データの
補償については、ご容赦ください。
・ 故障その他に伴う営業上の機会損失等は保証期間中お
よび保証期間経過後にかかわらず、補償はいたしかね
ますのでご了承ください。
・ 本製品を使用したことによるお客様、または第三者か
らのいかなる請求についても、当社は一切の責任を負
いかねます。
・ 諸事情による本製品に関連するサービスの停止、中断
について、一切の責任を負いかねます。
本機を寒いところから急に暖かいところに持ち込んだと
きなど、機器表面や内部に水滴がつくことがあります。
これを結露といいます。結露が起きたときは電源を切
り、結露がなくなるまで放置し、結露がなくなってから
ご使用ください。結露時のご使用は機器の故障の原因と
なる場合があります。
電解コンデンサの寿命は約 5 年です。
(常温で 1 日に 8 時間、1 カ月で 25 日間、通常に使用
すると想定した場合)
したがって、使用時間が上記より長い場合は、その分寿
命は短くなります。
電気メスなどの強い電磁波を発生する機器を同時に使用
する場合、事前に動作確認を行い、不具合の無いことを
確認した上でご使用ください。

13 JP
主な仕様

GB 2
Indication for Use / Intended use
The Sony UP-D898MD printer is a compact, medical
grade black and white digital printer. It is designed to be
integrated into digital radiology imaging systems such
as mobile c-arm, ultrasound, cardiac cath lab and other
compatible medical imaging systems and produce hard
copy prints of still images captured by these systems for
the patient record or for referrals.
Note
Images printed from the unit cannot be used for
diagnostic use.
Caution
Federal law (United States of America) restricts this
device to sale by or on the order of a licensed healthcare
practitioner.
Owner’s Record
The model and serial numbers are located at the bottom.
Record these numbers in the space provided below.
Refer to these numbers whenever you call upon your
Sony dealer regarding this product.
Model No. ____________________
Serial No. ____________________
To reduce the risk of fire or electric shock, do
not expose this apparatus to rain or moisture.
To avoid electrical shock, do not open the
cabinet. Refer servicing to qualified personnel
only.
No modification of this equipment is allowed.
THIS APPARATUS MUST BE EARTHED.
To disconnect the main power, unplug the
power plug.
When installing the unit, incorporate a readily
accessible disconnect device in the fixed
wiring, or connect the power plug to an easily
accessible socket-outlet near the unit.
Do not position the ME equipment where it is
difficult to unplug the power plug.
If a fault should occur during operation of the
unit, operate the disconnect device to
switch the power supply off, or unplug the
power plug.
For the customers in the U.S.A.
This equipment has been tested and found to comply
with the limits for a Class A digital device, pursuant to
part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful
interference when the equipment is operated in a
commercial environment. This equipment generates,
uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction
manual, may cause harmful interference to radio
communications. Operation of this equipment in a
residential area is likely to cause harmful interference in
which case the user will be required to correct the
interference at his own expense.
You are cautioned that any changes or modifications not
expressly approved in this manual could void your
authority to operate this equipment.
All interface cables used to connect peripherals must be
shielded in order to comply with the limits for a digital
device pursuant to Subpart B of part 15 of FCC Rules.
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device maynot cause harmful interference, and
WARNING
Symbols on the products
General warning sign
Follow the warnings in the Instructions for
Use for parts of the unit on which this mark
appears.
NOTE Background color: Yellow
Triangular band: Black
Symbol: Black
Consult the Instructions for Use
Follow the directions in the Instructions for
Use for parts of the unit on which this mark
appears.
This symbol indicates the manufacturer, and
appears next to the manufacturer’s name and
address.
This symbol indicates the European
Community representative, and appears next
to the European Community representative’s
name and address.
This symbol indicates the equipotential
terminal which brings the various parts of a
system to the same potential.

3GB
(2) this device must accept any interference received,
including interference that may cause undesired
operation.
For the customers in Canada
CAN ICES-3 (A)/NMB-3(A)
This unit has been certified according to Standard CAN/
CSA-C22.2 No.60601-1.
Important safeguards/notices for use in
the medical environments
1. All the equipments connected to this unit shall be
certified according to Standard IEC60601-1,
IEC60950-1, IEC60065 or other IEC/ISO Standards
applicable to the equipments.
2. Furthermore all configurations shall comply with the
system standard IEC60601-1-1. Everybody who
connects additional equipment to the signal input
part or signal output part configures a medical
system, and is therefore, responsible that the system
complies with the requirements of the system
standard IEC60601-1-1. If in doubt, consult the
qualified service personnel.
3. The leakage current could increase when connected
to other equipment.
4. For this particular equipment, all accessory
equipment connected as noted above, must be
connected to mains via an additional isolation
transformer conforming with the construction
requirements of IEC60601-1 and providing at least
Basic Insulation.
5. Thisequipment generates, uses, and can radiate radio
frequency energy. If it is not installed and used in
accordance with the instruction manual, it may cause
interference to other equipment. If this unit causes
interference (which can be determined by
unplugging the power cord from the unit), try these
measures: Relocate the unit with respect to the
susceptible equipment. Plug this unit and the
susceptible equipment into different branch circuit.
Consult your dealer. (According to standard IEC60601-
1-2 and CISPR11, Class B, Group 1)
Important EMC notices for use in the medical environments
• The UP-D898MD needs special precautions regarding
EMC and needs to be installed and put into service
according to the EMC information provided in this
instructions for use.
• The portable and mobile RF communications equipment
such as cellular phones can affect the UP-D898MD.
Warning
The use of accessories and cables other than those
specified, with the exception of replacement parts sold by
Sony Corporation, may result in increased emissions or
decreased immunity of the UP-D898MD.
Warning
If the UP-D898MD should be used adjacent to or stacked
with other equipment, it should be observed to verify normal
operation in the configuration in which it will be used.
Guidance and manufacturer’s declaration-electromagnetic emissions
The UP-D898MD is intended for use in the electromagnetic environment specified below.
The customer or the user of the UP-D898MD should assure that it is used in such an environment.
Emission test Compliance Electromagnetic environment-guidance
RF emissions
CISPR 11 Group 1
The UP-D898MD uses RF energy only for its internal
function. Therefore, its RF emissions are very low and are
not likely to cause any interference in nearby electronic
equipment.
RF emissions
CISPR 11
Class B
The UP-D898MD is suitable for use in all establishments,
including domestic establishments and those directly
connected to the public low-voltage power supply network
that supplies buildings used for domestic purposes.
Harmonic emissions
IEC 61000-3-2
Class A
Voltage fluctuations/
flicker emissions
IEC 61000-3-3
Complies
GB

GB 4
Guidance and manufacturer’s declaration - electromagnetic immunity
The UP-D898MD is intended for use in the electromagnetic environment specified below. The customer or the user of the
UP-D898MD should assure that it is used in such as environment.
Immunity test IEC 60601 test
level Compliance level Electromagnetic environment-guidance
Electrostatic
discharge (ESD)
IEC 61000-4-2
±6 kV contact
±8 kV air
±6 kV contact
±8 kV air
Floors should be wood, concrete or ceramic tile. If floors are
covered with synthetic material, the relative humidity should
be at least 30%.
Electrical fast
transient/burst
IEC 61000-4-4
±2 kV for power
supply lines
±1 kV for input/
output lines
±2 kV for power
supply lines
±1 kV for input/
output lines
Mains power quality should be that of a typical commercial or
hospital environment.
Surge
IEC 61000-4-5
±1 kV differential
mode
±2 kV common
mode
±1 kV differential
mode
±2 kV common
mode
Mains power quality should be that of a typical commercial or
hospital environment.
Voltage dips, short
interruptions and
voltage variations
on power supply
input lines
IEC 61000-4-11
< 5% UT
(> 95% dip in UT)
for 0.5 cycle
40% UT
(60% dip in UT)
for 5 cycles
70% UT
(30% dip in UT)
for 25 cycles
< 5% UT
(> 95% dip in UT)
for 5 sec
< 5% UT
(> 95% dip in UT)
for 0.5 cycle
40% UT
(60% dip in UT)
for 5 cycles
70% UT
(30% dip in UT)
for 25 cycles
< 5% UT
(> 95% dip in UT)
for 5 sec
Mains power quality should be that of a typical commercial or
hospital environment. If the user of the UP-D898MD requires
continued operation during power mains interruptions, it is
recommended that the UP-D898MD be powered from an
uninterruptible power supply or a battery.
Power frequency
(50/60 Hz)
magnetic field
IEC 61000-4-8
3 A/m 3 A/m Power frequency magnetic fields should be at least
characteristic of a typical location in a typical commercial or
hospital environment.
NOTE: UTis the a.c. mains voltage prior to application of the test level.

5GB
Guidance and manufacturer’s declaration - electromagnetic immunity
The UP-D898MD is intended for use in the electromagnetic environment specified below. The customer or the user of the
UP-D898MD should assure that it is used in such as environment.
Immunity test IEC 60601 test
level Compliance level Electromagnetic environment-guidance
Conducted RF
IEC 61000-4-6
Radiated RF
IEC 61000-4-3
3 Vrms
150 kHz to 80 MHz
3 V/m
80 MHz to 2.5 GHz
3 Vrms
3 V/m
Portable and mobile RF communications equipment should
be used no closer to any part of the UP-D898MD, including
cables, than the recommended separation distance
calculated from the equation appliance to the frequency of
the transmitter.
Recommended separation distance
d= 1.2 √P
d= 1.2 √P80 MHz to 800 MHz
d= 2.3 √P800 MHz to 2.5 GHz
Where Pis the maximum output power rating of the
transmitter in watts (W) according to the transmitter
manufacturer and dis the recommended separation distance
in meters (m).
Field strengths from fixed RF transmitters, as determined by
an electromagnetic site survey, ashould be less than the
compliance level in each frequency range. b
Interference may occur in the vicinity of equipment marked
with following symbol:
NOTE 1: At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and
reflection from structures, objects and people.
a Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile
radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To
assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be
considered. If the measured field strength in the location in which the UP-D898MD is used exceeds the applicable RF
compliance level above, the UP-D898MD should be observed to verify normal operation. If abnormal performance is
observed, additional measures may be necessary, such as reorienting or relocating the UP-D898MD.
b Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.

GB 6
Caution
When you dispose of the unit or accessories, you must
obey the law in the relative area or country and the
regulation in the relative hospital.
Warning on power connection
Use a proper power cord for your local power supply.
1. Use the approved Power Cord (3-core mains lead) /
Appliance Connector / Plug with earthing-contacts
that conforms to the safety regulations of each
country if applicable.
2. Use the Power Cord (3-core mains lead) / Appliance
Connector / Plug conforming to the proper ratings
(Voltage, Ampere).
If you have questions on the use of the above Power
Cord / Appliance Connector / Plug, please consult a
qualified service personnel.
Warning on power connection for
medical use
Please use the following power supply cord.
With connectors (plug or female) and cord types other
than those indicated in this table, use the power supply
cord that is approved for use in your area.
*Note: Grounding reliability can only be achieved when the equip-
ment is connected to an equivalent receptacle marked ‘Hospital Only’
or ‘Hospital Grade’.
For the customers in Europe
This product has been manufactured by or on behalf of
Sony Corporation, 1-7-1 Konan Minato-ku Tokyo, 108-
0075 Japan. Inquiries related to product compliance
based on European Union legislation shall be addressed
to the authorized representative, Sony Deutschland
GmbH, Hedelfinger Strasse 61, 70327 Stuttgart,
Germany. For any service or guarantee matters, please
refer to the addresses provided in the separate service or
guarantee documents.
Recommended separation distances between portable and mobile RF communications equipment and the
UP-D898MD
The UP-D898MD is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled.
The customer or the user of the UP-D898MD can help prevent electromagnetic interference by maintaining a minimum
distance between portable and mobile RF communications equipment (Transmitters) and the UP-D898MD as recommended
below, according to the maximum output power of the communications equipment.
Rated maximum output power of transmitter
W
Separation distance according to frequency of transmitter
m
150 kHz to 80 MHz
d= 1.2 √P
80 MHz to 800 MHz
d= 1.2 √P
800 MHz to 2.5 GHz
d= 2.3 √P
0.01 0.12 0.12 0.23
0.1 0.38 0.38 0.73
1 1.2 1.2 2.3
10 3.8 3.8 7.3
100 12 12 23
For transmitters rated a maximum output power not listed above, the recommended separation distance din meters (m) can
be estimated using the equation applicable to the frequency of the transmitter, where Pis the maximum output power rating
of the transmitter in watts (W) according to the transmitter manufacturer.
NOTE 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and
reflection from structures, objects and people.
United States and Canada
Plug Type HOSPITAL GRADE*
Cord Type Min.Type SJT
Min.18 AWG
Minimum Rating for Plug
and Appliance Couplers
10 A/125 V
Safety Approval UL Listed and CSA

7GB
Using this unit for medical purposes
This equipment's connectors are not isolated.
Do not connect any device other than one which
conforms to IEC60601-1.
When an information technology device or AV device
that uses an alternating current is connected, current
leakage may result in an electric shock to the patient or
operator.
If use of such a device is unavoidable, isolate its power
supply by connecting an isolation transformer, or by
connecting an isolator between the connecting cables.
After implementing these measures, confirm that the
reduced risk now conforms to IEC60601-1.
A paper cutter is mounted with the unit.
When cleaning the thermal head, be careful
not to touch the paper cutter. Touching the
paper cutter may cause injury.
Do not insert your finger into the back of the
paper tray. Your finger may become stuck in
an internal gap, which may lead to injury.
Caution
Do not touch any unit circuitry and the patient at the
same time.
If the unit malfunctions, it may generate voltage that
could be harmful to the patient.
Disposal of Old Electrical &
Electronic Equipment
(Applicable in Republic of
India)
This symbol indicates that this product shall not be
treated as household waste and may not be dropped in
garbage bins. Product owners are advised to deposit
their product at the nearest collection point for the
recycling of electrical and electronic equipment.
Your co-operation shall facilitate proper disposal & help
prevent potential negative consequences/hazards to the
environment and human health, which could otherwise
be caused by inappropriate waste disposal including
improper handling, accidental breakage, damage
and/ or improper recycling of e-waste. The recycling
of materials will help to conserve natural resources.
For more detailed information about recycling of this
product, please contact your local civic office, your
household waste disposal service provider or the store
where you made the purchase. You may contact our
company’s toll free number in India for assistance.
This product complies with the “India E-waste Rule
2011”.The E-waste Rules, 2011 is an Indian directive
aimed at reducing the harmful environmental impact of
waste electrical equipment by restricting the use of
known hazardous substances. As of 1st May 2012, new
electrical and electronic equipment introduced into the
market may no longer contain the following chemicals
or its specified maximum concentration levels:
Lead, Mercury, Hexavalent Chromium, Polybrominated
Biphenyls (PBB) or Polybrominated Diphenylethers
(PBDE) - in concentrations exceeding 0.1 weight % and
Cadmium - 0.01 weight %, except of exemptions set in
Schedule 2 of the aforesaid Rule.
Warning
Caution
Caution
Indiaonly
For the customers in the U.S.A.
SONY LIMITED WARRANTY - Please visit http://
www.sony.com/psa/warranty for important
information and complete terms and conditions of
Sony’s limited warranty applicable to this product.
For the customers in Canada
SONY LIMITED WARRANTY - Please visit http://
www.sonybiz.ca/solutions/Support.do for important
information and complete terms and conditions of
Sony’s limited warranty applicable to this product.
For the customers in Europe
Sony Professional Solutions Europe - Standard
Warranty and Exceptions on Standard Warranty.
Please visit http://www.pro.sony.eu/warranty for
important information and complete terms and
conditions.
For the customers in Korea
SONY LIMITED WARRANTY - Please visit http://
bpeng.sony.co.kr/handler/BPAS-Start for important
information and complete terms and conditions of
Sony’s limited warranty applicable to this product.

GB 8Using the CD-ROM Manual / Specifications
Using the CD-ROM
Manual
The supplied CD-ROM includes manuals for this printer
(in Japanese, English, French, German, Italian, Spanish,
Dutch, Swedish, Portuguese, Danish, Finnish,
Norwegian, Polish, Greek, Czech, Hungarian, Russian,
Romanian, Bulgarian, Slovakian, Slovenian, Estonian,
Latvian, Lithuanian, Croatian, Korean and Kazakh). The
copies of these manuals are created in pdf (Portable
Document Format).
Preparations
One of the following programs must be installed on your
computer in order to use the operation manuals
contained on the CD-ROM disc.
• Adobe Reader Version X or higher
Memo
If Adobe Reader is not installed, you can download it
from the following URL:
http://www.adobe.com/
Adobe and Adobe Reader are trademarks of Adobe Systems
Incorporated in the United States and/or other countries.
Reading the CD-ROM Manual
To read the manual on the CD-ROM, proceed as follows.
1
Insert the CD-ROM disc in your CD -ROM drive.
The manuals are saved in the Instructions For Use
folder.
2
Select and click the manual that you want to read.
Memo
The files may not be displayed properly, depending on
the version of Adobe Reader. In such a case, install the
latest version you can download from the URL
mentioned in “Preparations” above.
Note
If you lose the CD-ROM disc or you cannot read it for
some reason, you can purchase a new CD-ROM disc.
Contact your nearest Sony service representative.
Specifications
Power requirement
100 to 240 VAC, 50/60 Hz
Input current 1.3 A to 0.6 A
Operating temperature
5°Cto40°C(41°Fto104°F)
Operating humidity
20% to 80%
Operating pressure
700 hPa to 1,060 hPa
Storage and transport temperature
–20°Cto+60°C(–4°Fto+140°F)
Storage and transport humidity
20% to 80%
Storage and transport pressure
700 hPa to 1,060 hPa
Dimensions 154 ×88 ×240 mm (w/h/d)
(6 1/6 ×3 1/2 ×9 1/2 inches)
Mass 2.5 kg (5 lb 8.2 oz) (printer only)
Thermal head Thin-film thermal head, 1280 dots
Gradation 256-level gradation (8-bit)
Memory capacity
4096 ×1280 ×8 (bit)
Picture size 320 ×100 mm (max.)
Printing speed About 1.9 sec./image (960 ×1280
dots) (printing at the high speed)
About 3.3 sec./image (960 ×
1280 dots) (printing at the normal
speed)
Picture elements
4096 ×1280 dots (max.)
Dot density H: 100 mm/1280 dots = 0.078
V: 100 mm/1280 dots = 0.078
Square dots
Interface Hi-Speed USB (USB 2.0)
Accessories provided
Thermal head cleaning sheet (1)
CD-ROM (including multi-lingual
operating instructions, Readme and
printer driver) (1)
Before Using this Printer (1)
Service Contact List (1)
Optional accessories
Thermal Print Media
UPP-110HG (High Glossy)
UPP-110HD (High Density)
UPP-110S (High Quality)
Table of contents