Digital Monitoring Products GRAPHIC TOUCHSCREEN KEYPAD User manual

USER’S GUIDE
GRAPHIC TOUCHSCREEN KEYPAD
NOW 90
SAT 71 Reset

© 2013 Digital Monitoring Products, Inc.
Information furnished by DMP is believed to be accurate and reliable.
This information is subject to change without notice.
Silencing an Alarm
When the alarm siren is sounding, enter your user code or present your card to
a keypad during the Status List display.
All/Perimeter or Home/Sleep/Away System
IS THIS A FALSE ALARM? displays.
• If a burglar alarm is valid, press NO to send an alarm verication
message to the Central Station.
• If a valid alarm has not occurred, press YES to cancel the alarm
and send an ABORT or CANCEL message to the Central Station. The
keypad displays ALARM CANCELLED and the security system will be
disarmed.
What to do when a trouble tone is sounding
You can silence the trouble tone by touching any icon on the Main Screen. This
only silences the keypad and does not correct the condition that originally
caused the problem.

Graphic Touchscreen Keypad User’s Guide
Table of Contents
Section Page Section Page
Introduction ..............................................................1
How to use this guide................................................................1
Graphic Touchscreen Keypad......................................................1
Main Screen..............................................................................1
Interactive Shield ......................................................................2
Built-in Proximity Card Reader....................................................3
Power/Armed LED .....................................................................3
Weather Information .................................................................3
Carousel Menu ..........................................................................4
System Status Display ...............................................................5
Common Keys for Keypad Screen ...............................................6
COMMAND (CMD) .....................................................................6
Back Arrow ( <—).......................................................................6
Data Entry Digit keys.................................................................6
Keypad Select Areas ..................................................................6
Special Keypad Tones ................................................................6
Special Keypad Displays.............................................................7
Understanding Security System Terms ........................................8
Arming .....................................................................................8
Disarming .................................................................................8
Zone ........................................................................................8
Entry or Exit Zone .....................................................................8
Instant Zone .............................................................................8
24-Hour Zone............................................................................8
Areas .......................................................................................8
Central Station Monitoring..........................................................8
Status ......................................................................................8
Status List ................................................................................8
Zone Status ..............................................................................9
Armed Status............................................................................9
Exit Error ..................................................................................9
Arming and Disarming.............................................10
How Your System Operates......................................................10
Arming Functions .................................................................... 10
Key Fob Arming.......................................................................11
Key Fob Disarming ..................................................................11
System Arming........................................................................12
Home/Sleep/Away, Home/Away, and All/Perimeter..................... 12
System Disarming ...................................................................13
All Systems - with door entry ...................................................13
System Disarming ...................................................................13
Home/Sleep or Perimeter Systems - without door entry .............13
Disarming During an Alarm ......................................................14
Home/Sleep/Away, Home/Away, and All/Perimeter..................... 14
System Arming........................................................................14
Area Systems..........................................................................14
Arming the System..................................................................14
System Disarming ...................................................................16
Area Systems..........................................................................16
Disarming Area Systems During an Alarm .................................17
User Menu ...............................................................18
Accessing the User Menu ......................................................... 18
Common Keypad Displays ........................................................ 19
Graphic Touchscreen Keypad
User’s Guide

Introduction Graphic Touchscreen Keypad User’s Guide 1
Introduction
How to use this guide
This user guide is intended to provide information about how to
successfully use your Graphic Touchscreen Keypad to operate
your system. Since programming is different for each system at
installation, not all options described may be available for your
system. Each section gives instructions for all options available on
the keypad, contact your service provider for more information.
Please refer to the user guide provided with your control panel for
additional information on your system.
Graphic Touchscreen Keypad
Main Screen
Your system has an easy to use Graphic Touchscreen Keypad that
allows you to operate the system. When accessing any other screens
you may return to the Main Screen by pressing the blue mini shield
that displays in the upper left of the screen. In the event of an
alarm, the MainScreendisplaysredandaniconreectingthetype
of alarm displays in the center of the Interactive Shield.
Note: DO NOT use sharp objects to operate the touchscreen such
as a pen or pencil.
Graphic Touchscreen Keypad Main Screen
DISARMED
NOW
TUE
Panic
Chime
Check-in
Reset
MON 5:35 AM
Built in Proximity Card Reader
Carousel Menu
Interactive Shield
System Status Display
Power/Armed LED
Current Weather Information

2 Graphic Touchscreen Keypad User’s Guide
Interactive Shield Displays
Interactive Shield
The Interactive Shield provides arming and disarming from the Main
Screen.
Your system may be programmed for one of three arming options:
All/Perimeter, Home/Sleep/Away, or Area Arming.
Pressing the Shield displays an easy to
understand arming options screen. When
leaving in a hurry, press the shield until
it glows, the system quick arms the Away
system and starts the exit timer giving you
ample time to leave.
Once your system is armed the center of
the Shield will display an icon reecting
the status of your system. In the event of
an alarm, the Shield will display an icon
reectingthetypeofalarm.
Armed (Home)
Armed (All)
Armed (Away)
Armed (Area)
Alarm (Burglary)
Armed (Sleep)
Armed (Perimeter)
Alarm (Fire)
Interactive Shield

Graphic Touchscreen Keypad User’s Guide 3
Built-in Proximity Card Reader
Your keypad provides a built-in proximity card reader located
behind the Power/Armed LED for the ultimate in codeless arming/
disarming.
Power/Armed LED
The LED at the top-center of the keypad
indicates the keypad power
status and armed status of the panel. Depending on the operation,
the LED displays Red or Blue as listed in the table.
Color and Activity Armed Status Keypad Power Status
Blue Steady Panel Disarmed AC Power OK, Battery OK
Blue Blinking Panel Disarmed AC Power OK, Battery Fault
No Light Panel Disarmed AC Power Fault, Battery OK
Red Steady Panel Armed AC Power OK, Battery OK
Red/Blue Alternate Panel Armed AC Power OK, Battery Fault
Red Blinking Panel Armed AC Power Fault, Battery OK
Power/Armed LED
DISARMED
NOW
TUE
Panic
Chime
Check-in
Reset
MON 5:35 AM
Weather Information
DISARMED
NOW
TUE
Panic
Chime
Check-in
Reset
MON 5:35 AM
Dealer Logo
Weather Information
Your system may be programmed at installation to provide local
weather information. Weather conditions for today and tomorrow are
then displayed on the Main Screen.

4 Graphic Touchscreen Keypad User’s Guide
Carousel Menu zones in an Area system or all zones assigned to the perimeter in
a Home/Sleep/Away or All/Perimeter system. To deactivate, press
CHIME again until it glows.
4. PANIC: Your keypad may be programmed at installation to send
a POLICE, EMERGENCY, or FIRE report to the Central Station. If
this option is programmed for your keypad, pressing Panic on the
Carousel Menu displays the Panic Options screen. Press the desired
icon until it glows.
The Main Screen Carousel Menu provides scrollable options. (The
Panic, Chime, Check-in and Keypad icons are default options on
the Carousel). Scroll through the available options by pressing
within the CarouselMenuareaandmovingyourngerupordown.
You may select any options within the Carousel Menu by pressing
the desired icon.
Note: Pressing the blue mini shield that displays in the upper left
corner of any of the Carousel Menu screens will return you
to the Main Screen.
1. RESET: When your system had a
previousrealarm,thisoptionis
used to reset the smoke detector
sensors. Pressing RESET until it
glows resets the sensors. SENSORS
OFF displays in the upper right
corner followed by SENSORS ON
when RESET is successful.
2. CHECK-IN: Pressing CHECK-IN
until it glows displays the Keypad
screen prompting entry of a USER
CODE. Enter your user code to
send a Check-in Report.
3. CHIME: Press CHIME until it
glows. This activates MONITOR.
The System Status displays
MONITOR ON in the upper right
corner and a blue door icon
displays in the System Status
display. This initiates the Zone
Monitor operation for all Exit
Panic
Chime
Check-in
Reset
MONITOR ON
Main Screen
Carousel Menu
BRIGHTNESS
TONE
VOLUME
MODEL NUMBER 7800 V100 111912
INSTALLER
OPTIONS
7. Keypad User Options
PANIC OPTIONS
PRESS AND HOLD BUTTON TO SEND
FIRE
POLICE EMERGENCY
4. Panic
DISARMED
NOW
TUE
Panic
Chime
Check-in
Fire Reset
MONITOR ON
3. Chime
ENTER CODE:
RESET
1
ABC
5
MNO
9
YZ
2
DEF
6
PQR
0
3
GHI
7
STU
4
JKL
8
VWX
CMD
ALL
CHIME PERIM
HOME
SLEEP
USER MENU
USER CHECKIN?
2. Check-in
ALARM
Panic
Chime
Check-in
Fire Reset
1. Reset
EXIT TIMER
EXIT TIMER MON 5:35 PM
3 5
ARM
INSTANT
5. Easy Exit
SYSTEM READY
RESET
1
ABC
5
MNO
9
YZ
2
DEF
6
PQR
0
3
GHI
7
STU
4
JKL
8
VWX
CMD
ALL
CHIME PERIM
HOME
SLEEP
6. Keypad Screen
Reset
Easy Exit
Keypad
Options
MONITOR ON
Lights
Locks
Thermostats
Favorites
MONITOR ON
LIGHTS
MON 5:35 PM
OFF ON
OFF ON
OFF ON
Living Room Kitchen
-+-+
-+
Front Porch Bedroom
---- - - -
OFF ON
8. Z-Wave Lights
LOCKS
MON 5:35 PM
UNLOCK LOCK
Front Door Back Door
---- - - -
UNLOCK LOCK
Locked Unlocked
UNLOCK LOCK
Warehouse Door Upstairs Door
UNLOCK LOCK
Unlocked Locked
9. Z-Wave Locks
THERMOSTAT
MON 5:35 PM
SETPOINT
---- - - -
ON AUTO
70
72
HEAT
OFF
COOL
10. Z-Wave Thermostat
FAVORITES
MON 5:35 PM
Lock All Bedroom
---- - - -
Morning Movie
11. Z-Wave Favorites

Graphic Touchscreen Keypad User’s Guide 5
System Status Display
System Status display shown across the top of the Main Screen,
displays the armed status, System Ready or System Not Ready,
alarm or trouble conditions on a zone or a system monitor such as
AC or battery trouble. The right corner scrolls to display the day of
the week and time. The following icons display informing you of the
status of your system:
Green Check Mark - System Ready to arm:
No Green Check Mark - System Not Ready: (door or window
is open)
Yellow Triangle - Attention List: After disarming, if an
alarm on any zone or communication
problem has occurred while armed,
System Status at the top of the Main
Screen displays a yellow triangle Attention
List icon. When pressed, the attention
list displays listing the zone and event.
Blue Door - Chime (Monitor) On
5. EASY EXIT: When the system is armed, Press EASY EXIT until it
glows. This activates the Exit Delay timer allowing you to exit an
entry zone, such as the front door, without triggering the alarm or
needing to disarm and rearm the system.
6. KEYPAD: Pressing KEYPAD until it glows displays the Keypad
screen. This replicates the standard button type keypad. Scroll
through the User Menu by pressing CMD. Refer to Keypad Select
Areas and Common Keys for more information.
7. KEYPAD USER OPTIONS: Pressing OPTIONS until it glows
displays the Setting Options screen. You may adjust the Screen
Brightness, Tone, and Volume by pressing the arrows at either end
of the bar indicators.
8. Z-Wave LIGHTS: Press LIGHTS until it glows. This displays the
Z-Wave Lights screen allowing you to turn ON, turn OFF or DIM
Z-Wave equipped lights.
9. Z-Wave LOCKS: Press LOCKS until it glows. This displays the
Z-Wave Locks screen allowing you to LOCK or UNLOCK Z-Wave
equipped Doors and display the battery status of each lock.
10. Z-Wave THERMOSTAT: Press THERMOSTATS until it glows. This
displays the Z-Wave Thermostat screen allowing you to select
HEAT, COOL or FAN, turn them ON or OFF, and raise or lower
temperatures.
11. Z-Wave FAVORITES: Press FAVORITES until it glows. This
displays the Z-Wave Favorites screen allowing you to select and
activate Z-Wave Favorites.
DISARMED
NOW
TUE
Panic
Chime
Check-in
Fire Reset
MON 5:35 AM
System Status Display

6 Graphic Touchscreen Keypad User’s Guide
Special Keypad Tones
Your keypad contains an internal speaker that alerts you about
events as they occur on your system.
Note: Forburglaryalarms,thetonewillsilenceassoonastherst
user code digit key is pressed. If a valid user code is not
entered within 5 seconds or an invalid user code is entered,
the burglary tone begins sounding again.
Below are brief descriptions of the different tones you hear from
the keypad.
Fire alert: An intermittent sweeping siren that continuously repeats
until the re alarm is silenced. This is in addition to a separate
siren activated by the alarm panel.
Burglary Alert: A siren tone that continues until the alarm is
silenced. This is in addition to the separate siren output operated
by the alarm panel.
Prewarn: A tone that sounds when you open an entry delay door
on a system that is armed (turned on) reminding you to disarm the
burglary protection.
Your system will silence the tone as soon as the rst user code
digit key is pressed. If a valid user code is not entered within 5
seconds or an invalid user code is entered, the prewarn tone begins
sounding again.
Exit: When fully arming your system to leave, a pulsing tone sounds
during the exit countdown just after arming to remind you to exit
the premise. At ten seconds prior to the end of the countdown, the
rate of pulsing increases.
Monitor (Chime): A tone that sounds each time a door or window is
opened while you are using the Zone Monitor (Chime) option from
the User Menu. See Zone Monitor.
Trouble: A steady tone indicating a trouble condition on your
system.
Common Keys for Keypad Screen
COMMAND (CMD)
The CMD key allows you
to advance through the
keypad displays, User Menu,
or complete a data entry
function.
Back Arrow ( <—)
The Back Arrow (<—) is used
to go back through the keypad
displays while operating your
system. You may press the Back Arrow to back up through the list
of functions in the User Menu or to erase the last character entered.
Data Entry Digit keys
These keys allow you to enter your user code when arming or
disarming or enter other information into the system.
Keypad Select Areas
There are four touch-sensitive
areas in the keypad message
display that allow you to make
selections by pressing the
choice shown in the display.
Note: For the purposes of this
guide, when instructed
to press the rst Select
Area, press the far left
area in the message
display; the second
Select Area is the second from the left; third Select Area
is second from the right; and the fourth Select Area is the
far right.
1ABC
5MNO
9YZ
2DEF
6PQR
0
3GHI
7STU
4JKL
8VWX
CMD
Select Area 1 Select Area 2 Select Area 3 Select Area 4
Keypad Select Areas
SYSTEM READY
RESET
1ABC
5MNO
9YZ
2DEF
6PQR
0
3GHI
7STU
4JKL
8VWX
CMD
ALL
CHIME PERIM
HOME
SLEEP
CMD and Back Arrow Display

Graphic Touchscreen Keypad User’s Guide 7
Special Keypad Displays
As you use your system, you may occasionally see a message display
that asks you to enter a user code or describes a condition on the
system. Below are some examples of the displays you may see.
ALARM
A24-hourzone,suchasareorpaniczone,oranarmedburglary
zone is faulted. Your system may also sound wireless sirens.
ALARM NOT SENT
The alarm signal was aborted and was not sent to the Central
Station because a user code was entered to disarm the system
before the alarm signal was sent to the Central Station. Also, your
system may be pre-programmed at installation to send an Abort
signal to the Central Station.
ALARM CANCELLED
An Alarm signal just sent to the Central Station was cancelled
because a user code was entered after the alarm was sent. Also, an
Alarm Cancel signal is sent to the Central Station.
ALARM VERIFIED
Avalidburglaralarmhasoccurredandhasbeenmanuallyveried
by the user. The alarm system also transmits a VERIFY message to
the Central Station.
ENTER CODE
The system requires you to enter a personal user code. User codes
can be used for turning your system on (arming), turning your
system off (disarming), and other system options.
As you enter your user code, the display shows an asterisk (*) in
place of each digit pressed. This prevents others from seeing your
user code on the display as you enter it.
INVALID CODE or TRY AGAIN
The user code you entered is not recognized by the system. Check
the user code and try again.
TRBL (TROUBLE)
There is a problem with a protection device or system component.
This display is accompanied by a description of the problem.
SYSTEM TROUBLE or SERVICE REQUIRED
There is an electronic failure in your system. Contact the service
department as soon as possible.
TEST IN PROGRESS
The system is currently being tested by an installation or service
technician.

8 Graphic Touchscreen Keypad User’s Guide
Understanding Security System Terms
Throughout this guide, and in some displays on your keypad, you
may see certain words or phrases that might be unfamiliar.
Below are some common terms seen here and on the display.
Arming
This is the term used for turning on the burglary protection in one
or more areas of the system. Your system may require you to enter
a user code. When armed, the system can sound alarm sirens and, if
monitored, send alarm reports to a Central Station when a burglary
zone is faulted. Fire, panic, and other 24-hour devices are always
turned on and do not need to be armed.
Disarming
This means turning off one or more areas of the system. When
disarmed, the system does NOT sound alarms or send alarm reports
to a Central Station when a burglary zone faults.
Zone
A zone refers to a protected opening or protection device assigned
to a zone number. Each door or window, motion detector, smoke
detector, or other device has a zone number and a name.
Entry or Exit Zone
Almost all systems have one or more doors through which you can
enter or exit the premises. These doors are programmed with a
delay time to allow you to enter or exit while the system is armed
without setting off the alarm.
When you arm the system, activity on all burglary zones is ignored
until the programmed exit delay time expires. Once that time has
expired and the system is fully armed, opening the door causes the
panel to start the entry delay time. During the entry delay time,
enter a valid user code to disarm the system or an alarm occurs.
Instant Zone
Exterior windows and non-entry doors, or interior protection
devices, are typically not programmed with delay times. If these
zones fault while the system is armed, an alarm occurs instantly.
24-Hour Zone
A 24-hour zone is not turned on or off by arming or disarming your
system. Some examples of 24-hour zones are re zones, panic
zones, and temperature control zones.
Areas
An area is made up of burglary zones that can be armed or disarmed
together. The Perimeter area, for example, consists of all the doors
and windows on the outside of the building. When you arm the
Perimeter, these zones sound an alarm if tripped.
Central Station Monitoring
Your system can also be programmed to automatically send alarm,
trouble, and arming and disarming reports to a Central Station.
Operators at the Central Station can then dispatch the appropriate
authoritiesorcontactyouwiththespeciceventinformation.
Status
Status displays the system armed or disarmed status at the keypad
and on the upper right corner of the Main Screen. Alarm or trouble
conditions on a zone or a system monitor such as AC or battery
trouble can also display. There are two types of status information
available: Status List and Armed Status.
Status List
The Status List displays on the Keypad screen any alarm or trouble
condition on a zone and any trouble condition that occurs with
the AC power or battery power. If your system contains any Panic
zones, these do not display on the screen for security reasons.

Graphic Touchscreen Keypad User’s Guide 9
Ifanalarmoccursonanon-re,24-hourzoneorasystemmonitor,
it remains in the Status List until it restores. If one or more armed
burglary zones trips, the last one to trip remains in the Status List.
The burglary zone alarm remains in the Status List until it is cleared
by disarming the system. Pressing CMD allows the next status list
item to be displayed
Zone Status
To display the status of a particular zone, Press Keypad on the
Carousel Menu to display the Keypad screen. Enter the zone number
followed by CMD when the screen displays the Status List.
Armed Status
With Armed status, the screen displays the current armed condition
of areas within your security system.
The screen displays When
HOME SYSTEM ON The perimeter areas is armed in a
Home/Away system.
PERIMETER ON The perimeter is armed in an
All/Perimeter system.
ALL SYSTEM ON All areas are on.
SLEEP SYSTEM ON The perimeter and interior areas are on
but the bedroom area is off.
Exit Error
This is an automatic panel function that occurs if an exit door does
not close completely after the system is armed.
For example, if the front door is left ajar upon exit and the exit delay
time expires, the system attempts to arm the front door zone but
recognizes the open condition. The system sounds the alarm sirens
and starts the entry delay. If the open condition is not corrected, an
alarm and exit error is reported to the Central Station.
Exit Error allows the Central Station to acknowledge the arming
error without dispatching the police on a false alarm.

10 Graphic Touchscreen Keypad User’s Guide Arming and Disarming
Arming and Disarming
Arming Functions
Arming:Duringarming,thesystemveriesthatalldoors,windows,
and other protection devices to be armed are in normal condition.
If everything is normal, the system arms. If there is a problem on
one or more burglary zones, the Keypad screen displays the problem
and allows you to correct the problem or bypass those zones.
If the problem can be corrected by closing a door or window, do
not bypass the zone. Instead, correct the problem and try arming
again. If the problem cannot be corrected, you can bypass the zone
or wait until the zone can be repaired by a service technician. A
bypassed zone is ignored by the system during the armed period.
In some cases the Keypad screen might display FRONT DOOR -
FAULT. The screen may then display PRIORITY ZONE, which is a
zone that cannot be bypassed. The problem on the zone must be
corrected before the system can be armed.
After making your arming selection, the Keypad screen displays any
zones that are currently bypassed. These zones remain bypassed
until the system is armed and then disarmed. Any 24-hour zones in
a faulted condition also display.
Armed Message: After completing all bypasses or correcting zone
faults, the areas selected are armed.
For All/Perimeter systems the Keypad screen briey displays ALL
SYSTEM ON if all areas in the system are arming or PERIMETER ON
if only selected areas are arming.
For Home/Away or Home/Sleep/Away systems the Keypad screen
displays ALL SYSTEM ON if all areas in the system are arming, HOME
SYSTEM ON or SLEEP SYSTEM ON if only selected areas are arming.
How Your System Operates
Your system has been programmed to operate in one of three ways:
All/Perimeter, Home/Sleep/Away, or Area.
• All/Perimeter — your burglary protection is divided into two
areas: Interior and Perimeter.
All arms both the Perimeter and the Interior of the system.
You want to arm both of these areas when leaving the building
and no one is left inside.
Perimeter arming is for when you are staying inside but want
the comfort of knowing the exterior doors and windows are
armed. Perimeter arming allows you to move freely about
inside without setting off any interior alarms.
• Home/Sleep/Away — Your burglary protection is divided into two
or three areas: Perimeter, Interior, and Bedrooms.
Home (Perimeter) arming is for when you are staying inside
but want the comfort of knowing the exterior doors and
windows are armed.
Sleep (Perimeter and Interior) arms all areas except those
near bedrooms and nighttime areas.
Away (Perimeter, Interior, and Bedrooms) arms all three
areas for when you leave the building and no one is left
inside.
• Area — your burglary protection can be divided into as many
areas as your control panel supports. Each area can have a custom
name, be turned on or off independently of other areas, and limit
access to only those with proper authority.
Regardless of programming, much of the operation is similar.
Throughout this guide, any differences between the systems are
noted for your convenience.

Arming and Disarming Graphic Touchscreen Keypad User’s Guide 11
For an Area System the Keypad screen displays SYSTEM ON if
at least one area in the system is armed, followed by the area
numbers that were armed. The Keypad screen displays ALL SYSTEM
ON if all areas in the system are armed.
Exit Delay: The screen then displays the exit delay time as it counts
down. If the entire system has been armed, your system beeps the
exit delay tone at eight-second intervals until the last 10 seconds
when the keypad beeps at three second intervals. After exiting the
building, if you re-enter during the countdown the exit countdown
restarts, allowing additional time to then disarm or again exit the
building during the countdown. This restart can occur only one
time. When the exit delay time expires, zones are armed. If your
system uses a keyswitch to arm an area, the exit delay time does
NOT count down on the screen display.
When you arm both the Perimeter and Interior to leave the
building but then you do not exit by the time the exit delay ends,
the system automatically arms but the interior area(s) remain
disarmed because you have not exited.
Instant: During the exit delay time, you can cancel the exit
and entry delays and cause all zones to be instant zones.
Press ARM INSTANT while the exit delay displays. This immediately
arms the exit zones. However, no entry delay is provided and an
alarm immediately occurs should an entry door be opened.
ONE MOMENT . . . Message: If your system is monitored, it may
be programmed to wait for the arming report to be sent to the
monitoring station before displaying the armed message. This
veriesthatthearmingmessagewasreceivedbyyourmonitoring
station. While the system waits, the screen displays ONE MOMENT....
When the report is received, the keypad buzzes for one second
and displays the armed message. If the report is not received, the
screen displays LOCAL ALARM ONLY before displaying the armed
message.
Key Fob Arming
Press the key fob button programmed for Arming or Toggle (Arm/
Disarm) button. A Red LED two-second acknowledgement indicates
All System On. A Green/Red two second acknowledgement
indicates System On with some areas armed.
Key Fob Disarming
Press the key fob button programmed for Disarming or Toggle
(Arm/Disarm) button. A Green LED two-second acknowledgement
indicates All System Off.

12 Graphic Touchscreen Keypad User’s Guide Arming and Disarming
2. Once released, the Exit Timer
screen displays and begins counting
down your programmed exit time.
3. To cancel arming your system
during Exit Timer count down,
press ENTER CODE TO CANCEL and
the Keypad screen displays. You
may now enter your User Code to
discontinue arming. If any zones
are faulted or bypassed, the system displays those zones.
4. At this point you can force arm or bypass any faulted burglary
zones. A zone that is force armed is restored into the system
if it later returns to normal. A zone that is bypassed remains
bypassed until the system is disarmed. See steps 4a through 4d.
4a. If a problem exists on any
zones, the zone name
and problem are shown
followed by: OK BYPASS
STOP.
4b. Press OK to force arm the
zone(s) before arming.
4c. Press BYPASS to bypass the
zone(s) before arming.
4d. Press STOP to stop the system from arming. Correct the
zone problem(s) and return to step 1.
Note: 24-hour zones cannot be bypassed.
5. The screen displays SYSTEM ON if at least one area in the system
is armed, and ALL SYSTEM ON if all areas in the system are
armed.
6. The screen then displays the exit time in seconds and counts
down the remaining time: EXIT: # # (# # = seconds remaining).
When the entire system is armed, the keypad sounds the exit
delay alert and when the delay expires, the zones are armed.
EXIT TIMER
EXIT TIMER MON 5:35 PM
3 5
ENTER CODE
TO CANCEL
ARM
INSTANT
Exit Timer
OK AY BYPASS STOP
RESET
1ABC
5MNO
9YZ
2DEF
6PQR
0
3GHI
7STU
4JKL
8VWX
CMD
ALL
CHIME PERIM
HOME
SLEEP
OK Bypass Stop Keypad Options
System Arming
Home/Sleep/Away, Home/Away, and All/Perimeter
On the Main Screen, press the center
of the Shield icon and release.
This displays the Arming Options
screen. Depending on which arming
system has been programmed, one
of the following screens displays:
• 1. Home/Sleep/Away
• 2. Home/Away
• 3. All/Perimeter
1. To select the desired Arming
Options press the icon until it
glows.
ARMING
PRESS A BUTTON TO ARM SYSTEMARMING OPTIONS
HOME SLEEP AWAY
Home/Sleep/Away Arming Option
ARMING
PRESS A BUTTON TO ARM SYSTEMARMING OPTIONS
HOME AWAY
Home/Away Arming Option
All/Perimeter Arming Option
ARMING
PRESS A BUTTON TO ARM SYSTEMARMING OPTIONS
ALL PERIMETER
Main Screen Interactive Shield

Arming and Disarming Graphic Touchscreen Keypad User’s Guide 13
System Disarming
Home/Sleep or Perimeter Systems - without door entry
Disarming:
1. On the Main Screen, press the
Shield and release.
2. The screen displays ENTER CODE:.
Enter your user code or present
credential to disarm the system.
ALL SYSTEM OFF is displayed in the
upper right corner after the system
disarms, the Shield indicates a
disarmed status.
System Disarming
All Systems - with door entry
Disarming: While the system is armed, you may only enter the
premises through an entry/exit delay door without causing an
alarm. After opening the door, the keypad sounds a prewarn tone
to remind you to disarm the system. You must disarm the system
before the delay time expires or an alarm on the door zone occurs.
1.
During the prewarn tone, the
screen displays ENTER CODE:
and the zone entered through.
Enter your user code or present
credential to disarm the system.
Only those areas authorized
for your user code will disarm.
Your system silences the tone as
soon as the rst user code digit is
pressed. If a valid user code is not
entered within 5 seconds or an
invalid user code is entered, the
prewarn tone begins sounding again.
2. ALL SYSTEM OFF is displayed in
the upper right corner after the
system disarms, the Main Screen
Shield indicates a disarmed status.
After disarming, if an alarm on any
zone or communication problem
has occurred while armed, the Main
Screen displays a yellow triangle
Attention List icon at the top of the
screen. Pressing the yellowAttention
List icon above the Shield displays the attention list. Pressing the
blue mini shield on the top left of the attention list returns to the
Main Screen.
ENTER CODE:-
RESET
1ABC
5MNO
9YZ
2DEF
6PQR
0
3GHI
7STU
4JKL
8VWX
CMD
ALL
CHIME PERIM
HOME
SLEEP
USER MENU
FRONT DOOR
FRONT DOOR with ENTER
CODE:- Keypad Display
ATTENTION LIST
ZONE: 27 -ALARM WAREHOUSE
ZONE: 29 -ALARM
Attention List Display
DISARMED
NOW
TUE
Panic
Chime
Check-in
Reset
SYSTEM ON
Attention
List
Main Screen with
Attention List Display
Main Screen Interactive Shield
ENTER CODE:-
RESET
1ABC
5MNO
9YZ
2DEF
6PQR
0
3GHI
7STU
4JKL
8VWX
CMD
ALL
CHIME PERIM
HOME
SLEEP
USER MENU
ENTER CODE:- Keypad Display
DISARMED
NOW
TUE
Panic
Chime
Check-in
Reset
SYSTEM ON
Attention
List
Main Screen with
System Status Display

14 Graphic Touchscreen Keypad User’s Guide Arming and Disarming
Disarming During an Alarm
Home/Sleep/Away, Home/Away, and All/Perimeter
1. While the alarm bell or siren
sounds, you may choose to
enter your user code or present
credential to silence the alarm
sounder.
For a burglary alarm, the screen
displays IS THIS A FALSE ALARM?
or CANCEL VERIFY.
This display remains on the screen until a selection is made or
the internal system bell cutoff timer expires.
After the pre-programmed alarm communication delay, the
alarm is sent to the Central Station. This allows you to investigate
the alarm prior to disarming the system.
Note: Thealarm sounder willsilenceatthe rst keypressedbut
this does not cancel the alarm.
2. If a valid alarm has not occurred,
press YES to disarm the
system and cancel the alarm.
The screen displays ALARM
CANCELLED then ALL SYSTEM
OFF is displayed in the System
Status area on the Main Screen to
conrmthesystemisdisarmed.
OR
If the alarm is valid, press NO to send an alarm verify message
to the Central Station.
System Arming
Area Systems
Your security system is programmed into separate areas.
You may arm and disarm all areas at one time or each area individually.
You may only arm or disarm areas authorized for your user code.
After entering your user code, the system allows you to arm either
all of the areas to which you have access or one or more selected
areas. If you choose to arm all areas, the system begins verifying
that all zones in those areas are in a good condition. If you choose
to arm selected areas, the system prompts you to choose the areas
you want to arm.
Arming the System
1. On the Main Screen, press the
Shield to display Keypad.
2. Press CMD until ARM DISARM
displays on the screen.
ALARM CANCELLED
Keypad Display
ALARM CANCELLED
RESET
1ABC
5MNO
9YZ
2DEF
6PQR
0
3GHI
7STU
4JKL
8VWX
CMD
ALL
CHIME PERIM
HOME
SLEEP
ALARM? NO YES
RESET
1
ABC
5
MNO
9
YZ
2
DEF
6
PQR
0
3
GHI
7
STU
4
JKL
8
VWX
CMD
ALL
CHIME PERIM
HOME
SLEEP
USER MENU
IS THIS A FALSE
IS THIS A FALSE ALARM?
Keypad Display
ARM DISARM
RESET
1ABC
5MNO
9YZ
2DEF
6PQR
0
3GHI
7STU
4JKL
8VWX
CMD
ALL
CHIME PERIM
HOME
SLEEP
USER MENU
ARM/DISARM Keypad Display
Main Screen Interactive Shield

Arming and Disarming Graphic Touchscreen Keypad User’s Guide 15
3. Press ARM to display ALL? NO YES.
Enter your user code if required.
4. Select NO to arm only selected
areas. Go to step 5. Select YES to
arm all areas authorized for your
user code.
5. If NO is selected in step 4,
the display begins to list
each area to which you have access followed by NO YES.
Example: OFFICE NO YES.
5a. Select YES for each area
you want to arm.
5b. Select NO for each area
you do NOT want to arm.
Note: You may also press the area
numbers you want to arm
while ALL? NO YES displays.
This changes the display to
AREAS:. The numbers you select
appear in the display. For example: AREAS: 2 4. Press
CMD
when done.
6. The system displays any faulted
and bypassed zones.
7. At this point you can force arm
or bypass any faulted burglary
zones. A zone that is force armed
is restored into the system if it
later returns to normal. A zone
that is bypassed remains bypassed until the system is disarmed.
See steps 7a through 7d.
7a. If a problem exists on any
zones, the zone name and
problem are shown followed
by: OKAY BYPASS STOP.
7b. Select OKAY to force arm
the zone(s) before arming.
7c. Select BYPASS to bypass the
zone(s) before arming.
7d. Select STOP to stop the
system from arming.
Correct the zone problem(s)
and return to step 1.
Note: 24-hour zones cannot be
bypassed.
8. The screen displays SYSTEM ON if
at least one area in the system is
armed, and ALL SYSTEM ON if all
areas in the system are armed.
9. The screen then displays the
exit time in seconds and counts
down the remaining time: EXIT: # #
(##= seconds remaining). When the
entire system is armed, the keypad
sounds the exit delay alert and
when the delay expires, the zones
are armed and the screen displays
the Shield with the Area icon in
the center.
ALL? NO YES
RESET
1ABC
5MNO
9YZ
2DEF
6PQR
0
3GHI
7STU
4JKL
8VWX
CMD
ALL
CHIME PERIM
HOME
SLEEP
ALL? NO YES Keypad Display
AREAS: 1 2 4 6
RESET
1ABC
5MNO
9YZ
2DEF
6PQR
0
3GHI
7STU
4JKL
8VWX
CMD
ALL
CHIME PERIM
HOME
SLEEP
AREAS: Armed
Keypad Display
RESET
1ABC
5MNO
9YZ
2DEF
6PQR
0
3GHI
7STU
4JKL
8VWX
CMD
ALL
CHIME PERIM
HOME
SLEEP
FRONT DOOR
ZONE: 1 -FAULT
Zone Fault Keypad Options
OK AY BYPASS STOP
RESET
1ABC
5MNO
9YZ
2DEF
6PQR
0
3GHI
7STU
4JKL
8VWX
CMD
ALL
CHIME PERIM
HOME
SLEEP
Okay Bypass Stop
Keypad Display
ALL SYSTEM ON
RESET
1ABC
5MNO
9YZ
2DEF
6PQR
0
3GHI
7STU
4JKL
8VWX
CMD
ALL
CHIME PERIM
HOME
SLEEP
ALL SYSTEM ON
Keypad Display
EXIT TIMER
EXIT TIMER MON 5:35 PM
3 5
ARM
INSTANT
Exit Timer
ARMED
Panic
Chime
Check-in
Fire Reset
AREA ARMED Display

16 Graphic Touchscreen Keypad User’s Guide Arming and Disarming
System Disarming
Area Systems
1. Press the Shield on the screen.
2 Press CMD until ARM DISARM
displays. During entry delay this
process starts at step 4 below.
3. Press DISARM to disarm areas.
4. The screen displays ENTER CODE:.
Enter your user code and press CMD
or present credential. The screen
displays ALL? NO YES.
5. Press YES to disarm all areas
authorized for your user code.
5a. Press NO to disarm only
certain areas individually.
The screen then displays
the name of each area
authorized for your code
followed by the NO YES display.
5b. Press YES to disarm the area
displayed.
5c. Press NO to not disarm and
to display the next area.
Note: You may also press the area
numbers you want to disarm
while at the ALL? NO YES display.
This changes the display to
AREAS: . The area numbers you press appear in the display.
For example: AREAS: 2 4. To remove an area number from
the display, press the corresponding number on the screen.
Press CMD when done.
6. After all areas have displayed,
any alarms that occurred during
the armed period are shown.
If all areas are disarmed, the
screen displays ALL SYSTEM OFF
in the System Status area on
the Main Screen to conrm the
system is disarmed.
ARMED
Panic
Chime
Check-in
Fire Reset
AREA ARMED Display
ARM DISARM
RESET
1ABC
5MNO
9YZ
2DEF
6PQR
0
3GHI
7STU
4JKL
8VWX
CMD
ALL
CHIME PERIM
HOME
SLEEP
ARM/DISARM Keypad Display
ALL? NO YES
RESET
1ABC
5MNO
9YZ
2DEF
6PQR
0
3GHI
7STU
4JKL
8VWX
CMD
ALL
CHIME PERIM
HOME
SLEEP
ALL? NO YES Keypad Display
ENTER CODE:-
RESET
1ABC
5MNO
9YZ
2DEF
6PQR
0
3GHI
7STU
4JKL
8VWX
CMD
ALL
CHIME PERIM
HOME
SLEEP
ENTER CODE:- Keypad Display
AREAS: 1 2 4 6
RESET
1ABC
5MNO
9YZ
2DEF
6PQR
0
3GHI
7STU
4JKL
8VWX
CMD
ALL
CHIME PERIM
HOME
SLEEP
AREAS: Armed
Keypad Display
DISARMED
NOW
TUE
Panic
Chime
Check-in
Reset
SYSTEM ON
Attention
List
Main Screen with
Attention List Display

Arming and Disarming Graphic Touchscreen Keypad User’s Guide 17
Disarming Area Systems During an Alarm
1. While the alarm bell or siren
sounds, the screen displays a red
keypad background, the zone name
and number. Press CMD until ARM
DISARM displays.
After the pre-programmed alarm
communication delay, the alarm is
sent to the Central Station. This allows you to investigate the
alarm prior to disarming the system. This display remains on the
screen until a selection is made, the blue mini shield is pressed,
or the internal system bell cutoff timer expires.
Note: Thealarmsounderwillsilenceat therstkeypressedbut
this does not cancel the alarm.
Note: From this point the disarming sequence is the same as Area
Disarming steps 2 through 6 in the previous section.
2. The screen may display ALARM
CANCELLED if your system was
disarmed after alarm message had
been sent to the central station.
If your system was disarmed before
the alarm message had been sent to
the central station, the screen may
display ALARM NOT SENT.
3. If all areas are disarmed, the screen
displays ALL SYSTEM OFF in the
System Status area on the Main Screen
toconrmthesystemisdisarmed.
RESET
1ABC
5MNO
9
YZ
2DEF
6PQR
0
3GHI
7STU
4JKL
8VWX
CMD
ALL
CHIME PERIM
HOME
SLEEP
FRONT DOOR
ZONE: 1 -ALARM
Zone Alarm Keypad Display
ALARM CANCELLED
RESET
1ABC
5MNO
9YZ
2DEF
6PQR
0
3GHI
7STU
4JKL
8VWX
CMD
ALL
CHIME PERIM
HOME
SLEEP
ALARM CANCELLED
Keypad Display
ALARM NOT SENT
RESET
1ABC
5MNO
9YZ
2DEF
6PQR
0
3GHI
7STU
4JKL
8VWX
CMD
ALL
CHIME PERIM
HOME
SLEEP
ALARM NOT SENT
Keypad Display
Other manuals for GRAPHIC TOUCHSCREEN KEYPAD
1
Table of contents
Popular Other manuals by other brands

Buyers Products Company
Buyers Products Company LT22 installation instructions

NEC
NEC Slot-In PC with Intel Celeron 2 x 1.6 GHz CPU STv2 (Sandy... installation instructions

Axent
Axent PRIMUS installation instructions

Carlisle
Carlisle 183G-500 Service manual

IMR
IMR IX616 user manual

Sealey
Sealey VS8812 instructions