Digitron Easy Lock DPN13AG User manual

PAGE 9
PAGE 4
PAGE 2
MAINTENANCEMAINTENANCE
USER’S GUIDEUSER’S GUIDE
INSTALLATION GUIDEINSTALLATION GUIDE
READ THE INSTRUCTIONS CAREFULLY
BEFORE USE AND KEEP THEM FOR
FUTURE REFERENCE
READ THE INSTRUCTIONS CAREFULLY
BEFORE USE AND KEEP THEM FOR
FUTURE REFERENCE
!
Easy Lock
EasyEasy LockLock
Mod. DPN13AG/B/A
Mod. DPN18AG/B/A
PINPIN
V. 2
COMBINATION LOCK
2
5
8
0
1
4
7
3
ENT
STATUS
6
9
Bolt Lenght 13 mm
Bolt Lenght 18 mm

Press the button , insert a 4 digits code and press the button
The led will shortly flash 1 time every 2 seconds to indicate that the lock is
closed
Press the button .
Digit the choosen code for closing and press the button
Press the button .
Insert the 6 digits passepartout code
USER’S GUIDEUSER’S GUIDE
CLOSING
OPENING
OPENING WITH PASSEPARTOUT CODE
The company suggest the change of passepartout code set by factory and
inform about it to the authorized personnel only.
ENT
ENT
CHANGE OF PASSEPARTOUT CODE
ENT
ENT
PAGE 2
With the lock "open" press the button and release it later only after that led
has issued 2 short flashes and 1 longer.
Insert the 6 digits passepartout code in use and press the button .
If the passepartout code is correct, the led will turn on for 3 seconds.
When the led turns off press the button .
Insert the new 6 digits passepartout code and press the button .
If the new passepartout code has been correctly inserted, the led will turn on
for 3 seconds.
After having executed these operations, it is advisable to check and open the
lock with the new passepartout code.

TIMER SETTING
ENT
ENT
ENT
ENT
PAGE 3
By inserting the timer, the lock will open after an established time
everytime it is closed.
To set the timer please follow the instructions below:
With the lock "OPEN" press the button and release it only after the led has
issued 2 short flashes and 1 longer.
Insert the 6 digits passepartout code in use and press the button
If the passepartout code is correct, the led will turn on for 3 seconds.
When the led turns off press the button
Insert after how many hours the lock must automatically open by using the
numeric keyboard (from 1 to 99 hours) and press the button
For disconnecting the timer proceed as above and insert “0” as value of the hours.
Example: If you wish the lock opens after 8 hours press the button 8 and the button .
If you wish the lock opens after 12 hours press the button 1, the button 2 and
the button .
The led will shortly flash 2 times every 2 seconds to indicate that the lock is
closed with the timer “ON”.

READ CAREFULLYREAD CAREFULLY
When the batteries have not enough power to close the lock the led red turn ON and stays ON until the complete
discharge of the batteries. ( approximately 3 days )
Replace them only with ALKALINE batteries ( AAA ) observing the right polarities.
Do not use rechargable batteries
BATTERIES ( see page 5 )
OBSTACLE ( see page 7 )
PASSEPARTOUT CODE
CLEANING
Clean the lock exclusively with a dump cloth.
Avoid soap, solvents, alcohol etc.
AVOID TO MAKE ENTER THE WATER IN THE LOCK
If the water gets inside the lock in addition to discharge the batteries can permanently damage the lock
If the discharged batteries remain in the lock they could release some acid substances which damage the contacts
When you noted that the led is ON replace as soon as possible the batteries.
To avoid confusion is advisable to program the same code for all the locks installed.
In this case remove the obstacle or verify that the door is well-aligned and adjust, if it necessary, the hinges of the door
or the stop-bolt
FEW INSTRUCTIONS AND SOME SUGGESTIONS TO KEEP EFFICIENT THE LOCKSFEW INSTRUCTIONS AND SOME SUGGESTIONS TO KEEP EFFICIENT THE LOCKS
If during the closing ( or the opening ) the red led flashes quickly 8 times this means that the bolt has met an
obstacle and it unable to close ( or open ).
When you have the need to change the passepartout code verify that the new passepartout programmed
works correctly after the changing
11
2299
4433
5577
PAGE 4
ATTENTION
PLEASE NOTE THAT THE NON-OBSERVANCE OF THE RULES IN THIS GUIDE FOR A CORRECT
MAINTENANCE WILL AUTOMATICALLY VOID EVERY KIND OF WARRANTY OF THE PRODUCT.

2
5
8
0
1
4
7
3
ENT
STATUS
6
9
REPLACING THE BATTERIESREPLACING THE BATTERIES
THE LOCK DOES NOT WORK AND THE RED LED
IS “ON”
THE LOCK IS COMPLETELY INACTIVE
ALKALINE BATTERIES
( 1,5 V - AAA )
BATTERIES DISCHARGEDBATTERIES DISCHARGED
ALWAYS ONALWAYS ON
or
USE ONLY ALKALINE BATTERIES
DO NOT USE RECHARGEABLE BATTERIES
IT IS RECOMMANDED TO REPLACE THE BATTERIES WITHIN 2 YEARS FROM THEIR INSTALLATION
PAGE 5

PAGE 6
OBSTACLEOBSTACLE
OK
IF THE LOCK CLOSES BUT THE BOLT FORCES HORIZONTALLY AGAINST THE STOP-BOLT
( SEE FIGURE 2 ) THE CONSUMPTION OF BATTERIES DRASTICALLY INCREASES.
TO PREVENT SUCH DISAVANTAGES IT IS ADVISABLE TO KEEP A SECURITY AREA BETWEEN
THE BOLT AND THE STOP-BOLT SO THAT THE FUNCTIONING IS PERFECT EVEN WHEN
IT HAPPENS A FOULTY ALIGNEMENT OF THE DOOR.
IF DURING THE CLOSING PHASE THE BOLT HITS AGAINST THE STOP-BOLT AND IT DOES NOT
CLOSE ( SEE FIGURE 3 AND 4 ) AFTER 3 SECONDS THE BOLT COME BACK IN THE
POSITION “OPEN”..
THE REPETITION OF THE PROBLEM COULD DAMAGE THE INTERNAL MECHANISM..
!
!!
3 mm
3 mm
(Min.)
(Min.)
12
34

PAGE 7
2
5
8
0
1
4
7
3
ENT
STATUS
6
9
12
DOOR
COVER
KEYBOARD
USE OF EXTERNAL POWER SUPPLY ( PFAESEL02 )
2
5
8
0
1
4
7
3
ENT
STATUS
6
9
ON
ON
OFF
Unhook the cover with
the help of a screwdriver
by acting in the point
shown in the picture
EMERGENCY OPENING
Please be sure that the external power supply
commutator is on “ON” position.
Then connect the two metal point in the proper
holes paying attention to the polarity.
For opening the lock please keep connected
the metal point and press the button
then digit the 6 digits passepartout code.
1
2

INSTALLATION GUIDEINSTALLATION GUIDE
On the door make a 9 mm diameter
hole.
To determine the horizontal position
of the hole refer to the fixing quotas
as reported at page 14 fig. 10.1
and 10.2.
( see note 1 )
Nota 1 : Since the connection between keyboard and the lock is made with
flexible cable, the hole can be done, if necessary, in a different
position.
What is important is that the hole is inside the area of the lock-body
in order to have the possibility to place the wires under the lock-body
itself without coming-out.
Pass the cable of the keyboard across
the hole made on the door
1
2
1.1
2.1
Pic.
Pic.
9 mm
KEYBOARD
DOOR
CABLE
PAGE 8

Fix the keyboard to the door with the
help of n.4 cylindric head screws
diameter 3 mm - lenght 12 mm.
DIN 7505-B
After having removed the cover of
the lock pass the cable across the
proper hole placed on the back of
the lock and insert it in the connector
as shown in the picture
2
5
8
0
1
4
7
3
ENT
STATUS
6
9
12
3
5.5
( max )
3
3.1
4.1
3.2
Pic.
Pic.
Fig.
4
1
2
Click
PAGE 9

Fix the lock to the door with the help
of n. 4 cylindric head screws,
diameter 4 mm making sure that the
bolt correctly works both in closing
and opening phase, according to the
specification reported at page 14
fig. 10.1 and 10.2.
Please refer to the table below for the
lenght of the screws
L
4
8
( max )
Bend the cable as shown in picture
in order to position the wires between
the lock and the door
5
5.1
Pic.
6.1
Pic.
6
PAGE 10
17
16 18
20
15 18
14 16
13 16
12 14
Uqual or major of
( mm )( mm ) ( mm )( mm )
DOOR THICKNESSDOOR THICKNESS SCREW LENGHT ( L )SCREW LENGHT ( L )

Close the lock with the cover with the
help of the proper fixing screws.
Hook the cover to the keyboard as
shown in picture
7
7.1
Pic.
8
Click
1
2
3
DOOR
LOCK
COVER
KEYBOARD
8.1
Pic.
PAGE 11

The spacer is an optional
accessory to be used when
you want to leave the body of the
lock from the door.
More spacers can be used
for the door with reduced
thickness.
9
PAGE 12
9.1
9.2
Pic.
Pic. DOOR
4 mm
SPACER
KEYBOARD
LOCK
USE OF SPACER ( optional )

3 mm
2 mm
(Min.)
(Min.)
Model DPN18AG/B/A = 18 mm
10
10.1
10.2
Pic.
Pic.
QUOTE FOR LOCK FIXING
*
PLEASE NOTE THAT THE NON OBSERVANCE OF THE RULES
ABOVE DESCRIBED FOR A CORRECT INSTALLATION
WILL AUTOMATICALLY VOID EVERY KIND OF WARRANTY
OF THE PRODUCT PAGE 13
39
37.5
14
14
13
13
22
22
10
10
37.5
39
Hole on the door
9
Right opening door
Left opening door
BOLT
BOLT
10.1
Fig.
SCALE 1:1
*
*

68 5.2
99
2
5
8
0
1
4
7
3
ENT
STATUS
6
9
KEYBOARD + COVER
11
95 26
7514
13
n.4 holes
4
675
95
788.5 8.5
22 10
LOCK
*
*Model DPN18AG/B/A = 18 mm
DIMENSION
This manual suits for next models
5
Table of contents
Other Digitron Lock manuals
Popular Lock manuals by other brands

LOX
LOX EM5000 installation manual

Borglocks
Borglocks BL2400 Series instruction manual

Q-See
Q-See QSE7F4 user manual

HAUTAU
HAUTAU ZV/R Mounting and operating instructions

Sargent and Greenleaf
Sargent and Greenleaf 8550 Installation and Combinatiion Changing Instructions

PROMIX
PROMIX SM101 operating manual