DIHS Optima W R2+ User manual

Wireless Room Thermostat
This surface-
mounted radio thermostat has been developed to be able to switch electric and conventional heating
systems on and off using a set temperature and time.
Functions
Large display can be clearly read with the background lighting.
E
asy to fit thermostat and receiver.
Five buttons make it easy to use.
4 periods of each day programmable
The display shows the set temperature as well as the measured temperature, time.
Temperature display in degrees Celsius.
The thermostat is supplied wit
h a wall
Technical Data
Thermostat operating voltage:
Backup storage:
Receiver operating voltage:
Maximum voltage /
(ohmic) load:
Frequency:
Channel selection:
Switching options:
Receiver switch contacts:
Temperature settings:
Accuracy:
Thermostat dimensions:
Receiver dimensions:
Color:
IP protection rating:
Certification:
Wireless Room Thermostat
Optima
mounted radio thermostat has been developed to be able to switch electric and conventional heating
systems on and off using a set temperature and time.
Large display can be clearly read with the background lighting.
asy to fit thermostat and receiver.
Five buttons make it easy to use.
4 periods of each day programmable
The display shows the set temperature as well as the measured temperature, time.
Temperature display in degrees Celsius.
h a wall
-
fixing frame, base and a very compact receiver (surface
2 x AA1.5 V, alkaline batteries.
EEPROM
230 VAC, 50/60 Hz
(ohmic) load:
250 VAC/10 A.
868 MHz
By programming the thermostat and the receiver.
7day, 4 periods each day.
NO and NC.
5°C ~ 35°C, 0.5°C increments.
+/- 0.5°C
Surface mounted, 135mm x 87.5 mm x 23.2
mm.
Surface mounted, 86mm x 86 mm
White
20.
CE, Rohs, R&TTE
Optima
W R2 +
mounted radio thermostat has been developed to be able to switch electric and conventional heating
fixing frame, base and a very compact receiver (surface
-mounted).
By programming the thermostat and the receiver.
mm.

Wireless Room Thermostat Optima W R2 +
Display & Buttons
PRG. Schedule Setting
Long press PRG button to enter PRG setting. The weekday is fixed from Monday to Sunday(1~7), each day have 4
periods(1~4). Each press of PRG button can into next item setting.
The time and temperature of each period i can be set in following steps.
1). Press PRG and hold for 3 seconds, the time display flash, change the value by + and - button.(each press is 15mins)
2) Press PRG button , the temperature display flash, change the temperature by + and - button.
3). Press PRG button to next period.
4). The other period settings follow the same way.
Default Setting:
Period 1 2 3 4
Time Temp Time Temp Time Temp Time Temp
12345(Mon.~Fri.) 7:00 22℃8:30 19℃17:00 22℃22:00 19℃
6(Sat.) 8:00 22℃8:30 22℃17:00 22℃22:00 19℃
7(Sun.) 8:00 22℃8:30 22℃17:00 22℃22:00 19℃
Clock Adjustment
On/off Button
Mode Select & Time Adjust &
Sensor Calibration Button
Room Temp
Set Temp
Heat Icon
Programming Buttong &
MAN/PRG Mode Select
Week/Day
Time
PRG Period
PRG Mode
MAN Mode

Wireless Room Thermostat Optima W R2 +
-Press and hold the SET button for around 3 seconds. The minutes display (top left in the display) flashes.
-Change this value using the +and –buttons.
-Press the SET button . The hour display (top left in the display) flashes.
-Change this value using the +and –buttons.
-Press the SET button. The day display (top left in the display) will flash as a number.
-Change this value using the +and –buttons. Use 1 for Monday, 2 for Tuesday, 3 for Wednesday, 4 for
Thursday, 5 for Friday, 6 for Saturday and 7 for Sunday.
Code Pairing
-
I. Code Pairing with Sender
1) Long press the code pairing button on the receiver until LED 2 is flickering quickly.
2) Turn off sender, and long press SET button until the code shows on the screen, then press +button again.
3) Wait for a while, LED 2 stop flickering. Code pairing done.
II. Code Pairing with App
1) Scan the QR code, and download “Smart Life” APP from google play or app store
2) Install app and register account
3) Add device by press + button at top right corner
4) Press “ Home Applicanes II”
5) Find “ Thermostat or Heater” on the list and press
6) Long press Pairing button(F) on receiver to enter wifi connection mode, the LED will flash quickly.
7) Press “Confirm indicator rapidly blink” on phone.
8) Wait a moment till connection done. The LED on receiver will stop flashing. Wifi connection success.
If the LED still flash slowly, the connection fail, please try again from step. 5.
III. Clear all pairing
Long press both code pairing button and On/Off button for 5s, until LED1 and LED2 light.
And then light off, which mean the code pairing are eliminate.
Code pairing button
Heating on indicator (LED 1)
Power indicator (LED 2)
On/off button

Wireless Room Thermostat Optima W R2 +
IV. Signal Lost
In case the RF and WIFI signal lost/disconnected, LED 2 will flicker slowly.
Open Window Detection
When the Open Window detect function is enabled in the parameter setting, the system will automatically stop heating
when it detects a sudden drop of room temperature (2°C in 15 minutes as default). This is normally caused when a
window or door is opened without turning off the heating device.
The device will return to the previous mode of operation after 30mins, then OP disappear. Press any button will exit OWD
function during the heating off period.
Parameter Setting
Under off mode, press and hold SET button and +button for 6s to enter parameter setting. Each press of SET button will
go to next item setting. Adjust the value by pressing +or –button.
Wiring Diagram
Menu
Description Range Default Value
01 Temp. calibration for internal sensor -8 ℃~8 ℃0℃
02 Set Point Max. 5 ℃~35℃35 ℃
03 Set Point Min. 5 ℃~35℃5 ℃
05 Frost Protection Temp. 5 ℃~15℃5 ℃
09 Dead zone 0~3℃0℃
10 Display 0: Room temp.
1: SET temp.
0
12 Open window detect function 1: Enable 0: Disable
0
13 OWD Detect Time 2~30mins 15mins
14 OWD Drop temp. select
(within detect time)
2.3.4’C 2 ‘C
15 OWD Delay time select
(Return to previous working status)
10~60min 30mins
17 Factory reset 0: No 0
1: Yes, and then press
On/off button for 5s,wait
until thermostat restart
18 Software version 7109

Wireless Room Thermostat Optima W R2 +
Table of contents
Other DIHS Thermostat manuals
Popular Thermostat manuals by other brands

POOL
POOL WD 2.2 E user guide

Honeywell
Honeywell RTH221 Series Quick installation guide

Carrier
Carrier TSTATCCNTT01-B Installation and operating instructions

Telkonet
Telkonet SS5200 Installation & maintenance guidebook

HaiLin Controls
HaiLin Controls Elegance SMT-700 user manual

Pellux
Pellux CTP-02 Instructions for mounting and use

Carrier
Carrier MODULINE 37HS Installation instructions and parts list

meitav-tec
meitav-tec TAT-SUPER owner's manual

Aube Technologies
Aube Technologies TH209 owner's guide

BEINAT
BEINAT SC100 manual

Hoffmann
Hoffmann HRT-177RS Installation and user instructioins

Gewiss
Gewiss Chorus GW 10 764 Programming manual