DITEC ARC User manual

Ditec ARC
Swing gates
(translation of the original instructions)
Technical Manual
IP1725EN • 2023-01-23
www.ditecautomations.com
Last version of this manual

2
IP1725EN
Legend
This symbol indicates instructions or notes relating to safety which require special attention.
This symbol indicates useful information for the correct operation of the product.
Index
Declaration of incorporation of partly completed machinery .................................................................................... 4
UK Declaration of Conformity ............................................................................................................................ 5
1. Technical data ................................................................................................................................................ 6
1.1 Operating instructions ................................................................................................................................... 7
1.2 Machinery Directive ................................................................................................................................... 7
2. Standard installation ............................................................................................................................ 8
3. Dimensions and components ............................................................................................................................ 9
4. Installation .............................................................................................................................................. 10
4.1 Preliminary checks ................................................................................................................................. 10
4.2 Gearmotor installation ................................................................................................................................. 10
5. Electrical connections .......................................................................................................................... 12
6. Installing the accessories .......................................................................................................................... 14
6.1 ARCFB mechanical end stops................................................................................................................................. 14
6.2 BOXFC1 rotary limit switch unit ............................................................................................................ 14
6.3 Installing the key-operated handle with DEB04 release cord .................................................................. 18
7. Routine maintenance plan .......................................................................................................................... 19
8. Troubleshooting .............................................................................................................................................. 19

3
IP1725EN
General safety precautions
This installation manual is intended for qualified personnel only • Installation, electrical connec-
tions and adjustments must be performed by qualified personnel, in accordance with Good Working
Methods and in compliance with the current regulations • Read the instructions carefully before
installing the product. Wrong installation could be dangerous • Before installing the product, make
sure it is in perfect condition.
The packaging materials (plastic, polystyrene, etc.) should not be discarded in the environment
or left within reach of children, as they are a potential source of danger • Do not install the
product in explosive areas and atmospheres: the presence of inflammable gas or fumes represents
a serious safety hazard • Make sure that the temperature range indicated in the technical speci-
fications is compatible with the installation site • Before installing the motorization device, make
sure that the existing structure, as well as all the support and guide elements, are up to standards
in terms of strength and stability. Verify the stability and smooth mobility of the guided part, and
make sure that no risks of fall or derailment subsist. Make all the necessary structural modifica-
tions to create safety clearance and to guard or isolate all the crushing, shearing, trapping and
general hazardous areas • The motorization device manufacturer is not responsible for failure to
observe Good Working Methods when building the frames to be motorized, or for any deformation
during use • The safety devices (photocells, safety edges, emergency stops, etc.) must be installed
taking into account the applicable laws and directives, Good Working Methods, installation prem-
ises, system operating logic and the forces developed by the motorized door or gate • The safety
devices must protect against crushing, cutting, trapping and general danger areas of the motorized
door or gate. Display the signs required by law to identify hazardous areas • Each installation must
bear a visible indication of the data identifying the motorized door or gate • Before connecting the
power supply, make sure the plate data correspond to those of the mains power supply. An om-
nipolar disconnection switch with a contact opening distance of at least 3 mm must be fitted on
the mains supply. Check that there is an adequate residual current circuit breaker and a suitable
overcurrent cutout upstream of the electrical installation in accordance with Good Working Meth-
ods and with the laws in force • When requested, connect the motorized door or gate to an effec-
tive earthing system that complies with the current safety standards • Before commissioning the
installation to the end user, make sure that the automation is adequately adjusted in order to
satisfy all the functional and safety requirements, and that all the command, safety, and manual
release devices operate correctly.
During maintenance and repair operations, cut off the power supply before opening the
cover to access the electrical parts • The protection cover of the operator must be removed
by qualified personnel only.
The electronic parts must be handled using earthed antistatic conductive arms. The manu-
facturer of the motorization declines all responsibility if component parts not compatible with
safe and correct operation are fitted • Only use original spare parts for repairing or replacing
products • The installer must supply all information concerning the automatic, manual and emer-
gency operation of the motorized door or gate, and must provide the user with the operation and
safety instructions
ATTENTION! Important safety instructions.Please follow these instructions carefully.
Failure to observe the information given in this manual may lead to severe personal injury or
damage to the equipment.Keep these instructions for future reference.
This manual and those for any accessories can be downloaded from www.ditecautomations.com

4
IP1725EN
Declaration of incorporation of partly completed machinery
(Directive 2006/42/EC, Annex II-B)
We,
ASSA ABLOY Entrance Systems AB
Lodjursgatan 10
SE-261 44 Landskrona
Sweden,
declare, under our sole responsibility, that the type of equipment with the name:
Ditec ARC BH Irreversible automation for swing gates up to 2.5 m
Ditec ARC 1BH Irreversible automation for swing gates up to 5 m
complies with the following directives and their amendments:
2006/42/EC Machinery Directive (MD), regarding the following essential health and safety requirements:
1.1.2, 1.1.3, 1.2.1, 1.2.2, 1.2.3, 1.2.4.2, 1.2.6, 1.3.9, 1.4.3, 1.7.2, 1.7.3, 1.7.4, 1.7.4.1, 1.7.4.2.
2014/30/EU Electromagnetic Compatibility Directive (EMCD)
2011/65/EU Restriction of Hazardous Substances (RoHS 2)
2015/863/EU Restriction of Hazardous Substances (RoHS Amendment 2)
Harmonised European standards which have been applied:
EN 61000-6-3:2007 + A1:2011 + AC:2012
EN 60335-1:2012 + AC:2014 + A11:2014 + A13:2017 + A1:2019 + A14:2019 + A2:2019
Other standards or technical specifications which have been applied:
IEC 60335-1:2010 + C1:2010 + C2:2011 + A2:2013 + C1:2014 + A2:2016 + C1:2016
EN 12453:2017
The manufacturing process guarantees that the equipment complies with the technical documentation.
Responsible for the technical documentation:
Matteo Fino
BSP Ind channel & Gate Automation
Ditec S.p.A.
Largo U. Boccioni, 1
21040 Origgio (VA)
Italy
Signed on behalf of ASSA ABLOY Entrance Systems AB by:
Place Date Signature Position
Origgio 2023-01-23 Matteo Fino Head of Ind channel & Gate Automation
© ASSA ABLOY, All rights reserved

5
IP1725EN
UK Declaration of Conformity
We:
ASSA ABLOY Entrance Systems AB
Lodjursgatan 10
SE-261 44 Landskrona
Sweden
Declare under our sole responsibility that the types of equipment with names:
Ditec ARC BH Non-reversible automation for swing gates up to 2.5 m
Ditec ARC 1BH Non-reversible automation for swing gates up to 5 m
complies with the following directives and their amendments:
• Supply of Machinery (Safety) Regulations 2016
• Electromagnetic Compatibility Regulations 2016
• The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equip-
ment Regulations 2012 (RoHS)
Harmonized European standards that have been applied:
EN 61000-6-3:2007 + A1:2011 + AC:2012
EN 60335-1:2012 + AC:2014 + A11:2014 + A13:2017 + A1:2019 + A14:2019 + A2:2019
Other standards or technical specifications that have been applied:
IEC 60335-1:2010 + C1:2010 + C2:2011 + A2:2013 + C1:2014 + A2:2016 + C1:2016
EN 12453:2017
The manufacturing process ensures the compliance of the equipment with the technical file.
Responsible for technical file:
Matteo Fino
BSP Ind channel & Gate Automation
Ditec S.p.A.
Largo U. Boccioni, 1
21040 Origgio (VA)
Italy
Signed for and on behalf of ASSA ABLOY Entrance Systems AB by:
Place Date Signature Position
Origgio 2023-01-23 Matteo Fino Head of Ind channel & Gate Automation
© ASSA ABLOY, All rights reserved

6
IP1725EN
ARCBH ARC1BH
Type Irreversible wings up to 2.5 m Irreversible wings up to 5 m
Stroke control
(limit switch) Rotary limit switch (optional)
Power supply 24 V 24 V
Absorption 3 A 12 A
Power absorbed 75 W nom. 290 W nom.
Torque 150 Nm 300 Nm
Maximum stroke 120° 120°
Cycles / hour 12÷100 s / 90° 9÷50 s / 90°
Gate maximum weight 200 Kg 500 Kg
Service class 4 - INTENSE
(tested up to 300,000 cycles)
4 - INTENSE
(tested up to 300,000 cycles)
Intermittent operation S2 = 30 min (T= 25°C)
S3 = 50 % (T= 25°C)
S2 = 30 min (T= 25°C)
S3 = 50 % (T= 25°C)
Temperature (T) (with NIO active)
-20°C +55°C -35°C +55°C
Protection rating IP54 IP54
Poids 14 Kg 15 Kg
Applications
m = leaf width
kg = leaf weight
500 kg
400 kg
300 kg
200 kg
100 kg
m12345
500 kg
400 kg
300 kg
200 kg
100 kg
m12345
1. Technical data
WARNING: to prevent forced entry, the use of an electric lock is recommended with gate
wings measuring more than 2.3 m in length.

7
IP1725EN
1.2 Machinery Directive
Pursuant to Machinery Directive (2006/42/EC) the installer who motorizes a door or gate has the
same obligations as the manufacturer of machinery and as such must:
- prepare the technical file which must contain the documents indicated in Annex V of the Ma-
chinery Directive;
(The technical file must be kept and placed at the disposal of competent national authorities for
at least ten years from the date of manufacture of the motorized door);
- draw up the EC Declaration of Conformity in accordance with Annex II-A of the Machinery Direc-
tive and deliver it to the customer;
- affix the EC marking on the motorized door in accordance with point 1.7.3 of Annex I of the
Machinery Directive.
1.1 Operating instructions
Use: INTENSIVE (For vehicle or pedestrian accesses to large condominiums, industrial or com-
mercial complexes and parking lots with very frequent use).
- Performance characteristics are to be understood as referring to the recommended weight
(approx. 2/3 of maximum permissible weight) and at an ambient temperature of 25°C. When
used with the maximum permissible weight a reduction in the above mentioned performance
can be expected.
- Service class, running times, and the number of consecutive cycles are to be taken as merely
indicative Having been statistically determined under average operating conditions, and are
therefore not necessarily applicable to specifi c conditions of use.
- Each automatic entrance has variable elements such as: friction, balancing and environmental
factors, all of which may substantially alter the performance characteristics of the automatic
entrance or curtail its working life or parts thereof (including the automatic devices themselves).
The installer should adopt suitable safety conditions for each particular installation.

8
IP1725EN
2. Standard installation
3
6
2
1
A
5
5
5
7
4
4
Ref. Code Description Cable
1 ZEN Transmitter /
2FLM
FL24
Flashing light 2 x 1 mm²
Antenna (integrated in the flashing light) coax cable RG-58
(50 Ω)
3
AXK4 Digital combination wireless keypad /
AXK5M
AXR5I
AXK5NM
AXK5NI
Wall-mounted key-operated selector switch with European cylinder
Semi-recessed key-operated selector switch with European cylinder
Wall-mounted key-operated selector switch without cylinder
Semi-recessed key-operated selector switch without cylinder
4 x 0.5 mm²
AXR7 RFID reader unit 5 x 0.5 mm²
4Ditec ARCBH
Ditec ARC1BH
Actuator for door wing of up to 2.5 m
Actuator for door wing of up to 5 m 2 x 1.5 mm²
A
Connect the power supply to an approved omnipolar switch with an opening distance of
the contacts of at least 3 mm (not supplied).
The connection to the mains must be made via an independent channel, separated from
the connections to command and safety devices.
5
LIN2
LIN2B
AXP2
LAB4
Photocells 4 x 0.5 mm²
6LCU30H
LCU40H Control panel 3G x 1.5 mm²
7 LAB9 Magnetic loop 2 x 1.5mm²

9
IP1725EN
3. Dimensions and components
374
1
130
150
360
100
30 30150 150
Ø9
Ø9
45 45
54
65 65
370
30 30
2
Ref. Description
1Lid
2Fastening plate
3Gate mounting bracket
Ø9
200
60 60 1010 60
3

10
IP1725EN
4. Installation
4.1 Preliminary checks
Unless otherwise specified, all measurements are expressed in millimetres (mm).
Check that the structure is sufficiently rugged and that the hinge pivots are properly lubricated.
Provide an opening and closing stop.
4.2 Gearmotor installation
- Remove the gearmotor from the fastening plate [2].
- Fasten the fastening plate [2] to the gate pillar and the gate fastening bracket [3] to the gate
wing, according to the type of installation, as shown in the figures.
- Replace the gearmotor on the fastening plate [2].
LEFT-HAND INSTALLATION RIGHT-HAND INSTALLATION
PAY ATTENTION to the type of installation
600
90°
min 360
max
300
3
~120°
500
max
300 min 360
3
2
2

11
IP1725EN
- Drill a Ø14 hole in the lid near the release shaft [B] (there are two boring templates [C] on the
inside of the lid).
-Insert the rubber cap [D] supplied and fasten the lid to the gearmotor.
- Fasten the articulated arms as shown in the figure.
WARNING: move the wing to the fully closed position and align the arms to the holes [A].
- The arm articulations must be lubricated and the screws tightened so that they do not impede
the movement of the arms.
A
C Ø14
B
D
CØ14
B
D

12
IP1725EN
5. Electrical connections
Ditec ARCBH Ditec ARC1BH
Electronic panel LCU30H - LCU40H LCU40H
ARCBH (electronic panel LCU30H)
To reverse the rotation direction exchange the motor phases.
36 35 34 33 32 31 +-LP - +LK 1520 0168
JR1
24 V~
C
O
M
UPDOWN
TRF
ENTER
ESC
BATTERY
CHARGER
(SBU)
BAT
F
U
S
E
F1
Trasformatore
M2 M1
LN
Passo-passo
Apertura parziale
Antenna
Lampeggiante
Elettroserratura
SCHEDA AD INNESTO
AUX
-
+
Uscita 24 V
Arresto di sicurezza
Sicurezza in chiusura
24 V 24 V
Alimentazione
230 V~
50 / 60 Hz
BOXFC1
R
X
R
A
D
I
O
ZENRS
ZENPRS
NOTE: the electrical wiring and the start-up of the gearmotors are shown in the control
panel installation manuals.
Before connecting the power supply, make sure that the data on the plate correspond to the elec-
tricity distribution network data. Provide an omnipolar switch/disconnector on the power network
with a contact opening distance of 3 mm or more. Check that there is a suitable residual-current
device and surge protector upstream of the electrical system. Use an H05RN-F 3G1.5 electrical
cable and connect it to terminals L (brown) and N (blue) inside the automation system. Connect
the earth cable (yellow/green) to the earth terminal.
Secure the cable by means of the cable clamp and only unsheathe it at the terminal.
Connections to the electrical distribution network and any other low-voltage conductors (230 V), in
the section outside the automation system, must be made with corrugated pipes that are independ-
ent and separate from the path of connections to the control and safety devices (SELV = Safety Extra
Low Voltage). Make sure there are no sharp edges that could damage the power cord.
ATTENTION: always observe L-N polarity when connecting to the mains.
Ensure that the mains connection cables, any other low-voltage cables (230 V), and safety
extra-low voltage safety accessory connection cables in the portion located inside the prod-
uct are kept well separated from the gear motor body.
PLUG-IN BOARD
Flashing light
Electric lock
Step-by-step
Partial opening
24V output
Safety stop
Transformer
Closing safety device
respect L-N
polarity
Power supply
230 V~
50/60 Hz

13
IP1725EN
36 35 34 33 32 31
30 2 3 4 9 13
+-LP - +LK 30 5 20 016 018
JR1
24V~
COM
A
U
X
2
A
U
X
1
UP
DOWN
TRF
ENTER
ESC
SCHEDA AD INNESTO
SCHEDA AD INNESTO
F
U
S
E
F1
RADIO RX
Trasformatore
Passo-passo
Apertura parziale
Antenna
Chiusura
automatica esterna
Apertura
Chiusura
Stop
Lampada stato
automazione
Lampeggiante
Elettroserratura
AUX1 AUX2
1
30 30
1
-
+
Uscita 24 V
-
+
Uscita 24 V
Arresto di sicurezza
Sicurezza in chiusura
LN
BATTERY
CHARGER
(SBU)
BAT
Alimentazione
230 V~
50 / 60 Hz
ZENRS
ZENPRS
M2 M1
24 V 24 V
BOXFC1
ARCBH - ARC1BH (quadro elettronico LCU40H)
For complete control panel instructions see manual LCU30H - IP2251:
For complete control panel instructions see manual LCU40H - IP2246:
https://www.ditecautomations.com/global/market-documents/QR/Multilanguages/LCU30H/DitecLCU30H.pdf
https://www.ditecautomations.com/global/market-documents/QR/Multilanguages/LCU40H/DitecLCU40H.pdf
Automatic external
closing
Opening
Closure
Stop
Automation status lamp
PLUG-IN BOARD
PLUG-IN BOARD
Flashing light
Electric lock
Step-by-step
Partial opening
24V output
24V output
Safety stop
Transformer
Closing safety device
respect L-N
polarity
Power supply
230 V~
50/60 Hz

14
IP1725EN
6. Installing the accessories
6.1 Mechanical end stops (ARCFB)
Install the end stops as shown in the figure below.
Adjust the stops using the screws [A] and the nuts [B].
B
B
A
A
6.2 Rotary limit switch unit (BOXFC1)
ABC
Ref. Description
AMicroswitches
BFlange
CCams

15
IP1725EN
- Installing the rotary limit switch
WARNING: check that between the gearmotor and the limit switch
cams there is a distance of at least 1 mm.
Leave the
screws loose for
adjustment, see
next paragraph
NOTE: for the connections, see point 7
“Rotary limit switch adjustment”.
1
3
6
7
4
2
5
≥1mm

16
IP1725EN
OPENING
SWITCH
CLOSING
SWITCH
OPENING
SWITCH
CLOSING
SWITCH
OPENING
SWITCH
CLOSING
SWITCH
31/34
33/36
32/35
32/35
OPENING
SWITCH
CLOSING
SWITCH
OPENING
SWITCH
CLOSING
SWITCH
Completely close the wing (1) and
move the cam to activate the clos-
ing microswitch (2).
Tighten the screw (3).
Completely open the wing (4)
and move the cam to activate the
opening microswitch (5).
Tighten the screw (6).
Connect the fastons on the limit switch cables to the microswitches as shown in the figure (7).
For more details on the functions or adjustments, refer to chapter 5 and/or the technical manual
of the control panel.
Rotary limit switch adjustment for right-hand automation
1
4
2
5
3
6
7
6

17
IP1725EN
CLOSING
SWITCH
OPENING
SWITCH
CLOSING
SWITCH
OPENING
SWITCH
CLOSING
SWITCH
OPENING
SWITCH
CLOSING
SWITCH
OPENING
SWITCH
33/36
31/34
32/35
32/35
CLOSING
SWITCH
OPENING
SWITCH
Completely close the wing (1) and
move the cam to activate the clos-
ing microswitch (2).
Tighten the screw (3).
Completely open the wing (4)
and move the cam to activate the
opening microswitch (5).
Tighten the screw (6).
Connect the fastons on the limit switch cables to the microswitches as shown in the figure (7).
For more details on the functions or adjustments, refer to chapter 5 and/or the technical manual
of the control panel.
Rotary limit switch adjustment for left-hand automation
1
4
5
6
2
7
3

18
IP1725EN
6.3 Installing the key-operated handle with DEB04 release cord
To correctly install the DEB04 release handle
follow the procedure described below:
• Insert the plug [A] in the sheath fastening plate
[B], screw the adjuster [C] onto the plate [B] and
fasten to the gearmotor with a nut and washer.
• Insert the release cord [D] and the sheath [E]
(from DEB04) in the lid [F], in the adjuster [C],
in the spring [G] and in the release lever [H]
and fasten the cord to the clamp [J] inside the
lever [H].
A
D
F
C
J
H
G
E
C
B

19
IP1725EN
Carry out the following operations and checks every 6 months or 36,000 cycles, or according to the
intensity of use of the automation.
Disconnect the 230V~ power supply and batteries (if present):
- Lubricate the gearmotor levers.
- Lubricate the wing rotation pin.
- Lubricate the gate hinges.
- Check the electrical wiring is in good condition.
- Check that the gearmotor fastening screws are tight.
Reconnect the 230V~ power supply and batteries (if present):
- Check the power adjustment.
- Check that all commands and safety functions are operating correctly (photocells).
- Check the release system is working correctly.
- If batteries are fitted, check they are working properly (in continuity) by disconnecting the power
supply and performing a series of consecutive operations. At the end, reconnect the 230V~
power supply.
8. Troubleshooting
Problem Possible cause Operation
The gate doesn't
open or close.
No power supply. Make sure the mains supply is active.
Gearmotor released. See the release instructions.
Photocells occupied. Check the photocells are clean and
operating correctly.
Permanent STOP command. Check the STOP command or the control
panel.
Faulty selector. Check the selector or control panel.
Faulty remote control Check the condition of the batteries.
Electric lock not working Check the lock is positioned and work-
ing correctly.
The gate opens, but
it doesn't close. Photocells occupied. Check the photocells are clean and
operating correctly.
7. Routine maintenance plan
NOTE: for spare parts, please see the spare parts list.

IP1725EN
ASSA ABLOY Entrance Systems AB
Lodjursgatan 10
SE-261 44, Landskrona
Sweden
© ASSA ABLOY
All the rights concerning this material are the exclusive property of ASSA ABLOY Entrance Systems AB. Although
the contents of this publication have been drawn up with the greatest care, ASSA ABLOY Entrance Systems AB
cannot be held responsible in any way for any damage caused by mistakes or omissions in this publication.
We reserve the right to make changes without prior notice.
Copying, scanning or changing in any way is expressly forbidden unless authorised in writing by ASSA ABLOY
Entrance Systems AB.
The crossed-out wheelie bin symbol indicates that the product should be disposed of separately from
normal household waste. The product should be recycled in accordance with local environmental regula-
tions for waste disposal. By separating a product marked with this symbol from household waste, you will
help reduce the volume of waste sent to incinerators or land-fill and minimise any potential negative impact on
human health and the environment.
This manual suits for next models
2
Table of contents
Other DITEC Fencing & Gate manuals
Popular Fencing & Gate manuals by other brands

Magnetic
Magnetic MHTM FlowMotion mWing operating instructions

Ansell
Ansell Tretight Installation, user, maintenance and dismantling manual

Betafence
Betafence Quixolid Plus installation manual

Dogtra
Dogtra E-Fence 3500 owner's manual

Parktron
Parktron AGT 210 user manual

Cardinal Gates
Cardinal Gates WG35 Assembly instructions