DITEC Silver 1B/40B Manual

Manuale di installazione
emanutenzioneperauto-
mazioni per cancelli a
battente.
Installation and
maintenance manual for
swing gates.
Manuel d’installation et
d’entretien pour portes à
battant.
Montage und
Wartungshandbuch für
Drehflügeltore
Manual para la
instalaciòn y la
manutenciòn para
automatización para
cancelas batientes
Silver 1B / 40B
IP1592 05-03-2003
ISO 9001
Cert. n° 0957/1
DITEC S.p.A.
Via Mons. Banfi, 3
21042CaronnoP.lla(VA)Italy
Tel. +3902963911-Fax+39 029650314
www.ditec.it

2
DITECS.P.A-IP1592-SILVER
SILVER PF
Fig. 2
115
30
180
60
25 25 25
80
80
TX - 4x0.5 mm²
TX - 4x0.5 mm²
RX - 4x0.5 mm²
RX - 4x0.5 mm²
4x0.5 mm²
4x1.5 mm² 4x1.5 mm²
3x1.5 mm²
1
77
6
3
2
5
4
77
6
2x1.5 mm²
Fig. 1
I
GB
F
D
E
Impianto tipo
Standard installation
Installation type
Standard Montage
Instalaciòn tipo

3 DITECS.P.A-IP1592-SILVER
9
10
11
12
13
14
Fig. 4
15
8
16
Fig. 7
Fig. 8
Fig. 5
SILVER 1B / 40B
M1
~
UWV
Q.E. D1
LOGICA21
26 25 24
com
8 µF
Fig. 6
Fig. 9
UWV X Z Y
Q.E. D2
LOGICA22
com
com
26 25 24 26 25 24
M1
~M2
~
8 µF 8 µF
SILVER 1B / 40B
SILVER 1B = 1096
SILVER 40B = 1506
12090
Corsa max- Max stroke
Course max -Max Hub -
Carrera max
SILVER 1B = 280
SILVER 40B = 480
50
Fig. 3
E
F

4
DITECS.P.A-IP1592-SILVER
Fig. 10
D
L
EB
C
A
100
min
E
AB
C max
(90°) D
SILVER 1B 120 120 60 90°
120 100 40 100°
SILVER 40B
220 220 160 90°
140 240 180 90°
EL
70 1020
70 1020
90 1430
90 1430
200 200 140 100° 90 1430
180 180 120 100° 90 1430
160 220 160 100° 90 1430
200 180 120 110° 90 1430
220 140 80 120° 90 1430

8
DITECS.P.A-IP1592-SILVER
ENGLISH
APPLICATIONS
Maximum permissible weight and recommended weight: see TECHNICAL DATA
Service life: 3 (minimum 10÷5 years of working life with 30÷60 cycles a day)
Applications: FREQUENT (For vehicle or pedestrian accesses to town houses or small condominiums with frequent use).
Minimum number of consecutive cycles: 20
• Performance characteristics are to be understood as referring to the recommended weight (approx. 2/3 of maximum permissible
weight). A reduction in performance is to be expected when the access is made to operate at the maximum permissible weight.
• Service class, running times, and the number of consecutive cycles are to be taken as merely indicative having been statistically
determined under average operating conditions, and are therefore not necessarily applicable to specific conditions of use. During
given time spans product performance characteristics will be such as not to require any special maintenance.
• The actual performance characteristics of each automatic access may be affected by independent variables such as friction, balancing
and environmental factors, all of which may substantially alter the performance characteristics of the automatic access or curtail its
working life or parts thereof (including the automatic devices themselves). When setting up, specific local conditions must be duly
borne in mind and the installation adapted accordingly for ensuring maximum durability and trouble-free operation.
All right reserved
Alldataand specifications have been drawn upandcheckedwith the greatest care. Themanufacturercannothowever take any responsibility
for eventual errors, ommisions or incomplete data due to technical or illustrative purposes
GENERALSAFETYPRECAUTIONS
This installation manual is intended for professionally competent personnel only.
The installation, the electrical connections and the settings must be completed in conformity with good workmanship and with
the laws in force. Read the instructions carefully before beginning to install the product. Incorrect installation may be a source of danger.
Packaging materials (plastics, polystyrene, etc) must not be allowed to litter the environment and must be kept out of the reach of
children for whom they may be a source of danger. Before beginning the installation check that the product is in perfect condition. Do not
install the product in explosive areas and atmospheres: the presence of flammable gas or fumes represents a serious threat to safety.
Before installing the motorisation device, make all the structural modifications necessary in order to create safety clerance and to guard
or isolate all the compression, shearing, trapping and general danger areas. Check that the existing structure has the necessary
strength and stability. The manufacturer of the motorisation device is not responsible for the non-observance of workmanship in the
costruction of the frames to be motorised , nor for deformations that may be occur during use.
The safety devices (photoelectric cells, mechanical obstruction sensor, emergency stop, etc) must be installed taking into account: the
provisions and the directives in force, good workmanship criteria, the installation area, the funtional logic of the system and the forces
developed by the motorised door or gate.
The safety devices must protect against compression, shearing, trapping and general danger areas of the motorized door or gate.
Display the signs required by law to identify danger areas.
Each installation must bear a visible indication of the data identifying the motorised door or gate.
Before connecting to the mains check that the rating is correct for the destination power requirements.
A multipolar isolation switch with minimum contact gaps of 3 mm must be included in the mains supply.
Check that upstream of the electrical installation there is an adequate differential switch and a suitable circuit breaker.
When requested, connect the motorized door or gate to an effective earthing system carried out as indicated by current safety
standards. During installation, maintenance and repair operations, cut off the power supply before opening the cover to access the
electrical parts.
The electronic parts must be handled using earthed antistatic conductive arms.
The manufacturer of the motorising device declines all responsability in cases where components which are incompatible with
the safe and correct operation of the product only original spare parts must be used. For repairs or replacements of products
only original spare parts must be used. The fitter must supply all information corcerning the automatic, the manual and emergency
operation of the motorised door or gate, and must provide the user the device with the operating instructions.
It is recommended that antistatic conductive earthed arm bands be worn when manipulating electronic parts.
MACHINERYDIRECTIVE
Pursuant to Machinery Directive (98/37/EC) the installer who motorises a door or gate has the same obligations as the manufacturer of
machinery and as such must:
- prepare the technical file which must contain the documents indicated inAnnex V of the Machinery Directive; (The technical file must
be kept and placed at the disposal of competent national authorities for at least ten years from the date of manufacture of the
motorised door);
- draft the EC declaration of conformity in accordance with Annex II-A of the Machinery Directive and to release same to the customer;
- affix the CE marking on the power operated door in accordance with point 1.7.3 of Annex I of the Machinery Directive.
For more information consult the “Technical Manual Guidelines” available on Internet at the following address: http://www.ditec.it
DECLARATION BY THE MANUFACTURER
(Directive 98/37/EC, Annex II, sub B)
Manufacturer: DITECS.p.A.
Address: via Mons. Banfi, 3 - 21042 Caronno Pertusella (VA) - ITALY
Herewith declares that the electromechanical automatic system series SILVER
- is intended to be incorpored into machinery or to be assembled with other machinery to constitute machinery convered by Directive
98/37/EC, as amended;
- is in conformity with the provisions of the following other EEC directives:
ElectromagneticCompatibility Directive 89/336/EEC,as amended;
Low Voltage Directive 73/23/EEC, as amended;
and furthermore declares that it is not allowed to put the machinery into service until the machinery into which it is to be incorporated or
of which it is to be a component has been found and declared to be in conformity with the provisions of Directive 98/37/EC and with
nationalimplementinglegislation.
Caronno Pertusella, 26/02/1997. Fermo Bressanini
(Chairman)

9 DITECS.P.A-IP1592-SILVER
1TECHNICALDATA
2. REFERENCE TO ILLUSTRATIONS
2.1 Standard installation references (fig. 1)
ATTENTION: Only use DITEC’s safety devices and accessories for installation.
[1] Radio
[2] Flashing light
[3] Key selector
2.2 Accessories (fig. 2): SILVER PF Plateswith anchoringbracketsfor weld-freemounting
2.3 Geared motor references (fig. 4)
[8] Condenser
[9] Cover
[10] Release
3. INSTALLATION
3.1 Preliminary checks
Checkthat thestructureissufficiently sturdyandthat thehingepivotsare properlylubricated.Provide anopening
and closing stop.
Attention: SILVER 1B can only be installed if distance C is less than 60 mm (see Fig. 10)
3.2 Installing the geared motor
- Remove the geared motor from its package. Attention: Cover [9] is not secured.
- Position tailplate [11] on to the pillar to check installation measurements (see Figs. 10) and secure.
Note: The installation measurements given in the table in Figure 10 permit to select the values for [A] and [B]
according to the desired opening angle and with reference to existing room and spaces. Compliance with the
measurement given in the table is recommended. In order to ensure smooth gate movement, check that
measurements[A] and[B]are thesame.Increasing [A]reducesthe comingupspeed duringopening.Increasing
[B] diminishes the coming up speed during closing and improves burglar-proofing. Reducing [B] increases the
extent of gate opening. Measurements [A] and [B] must in any case be compatible with the useful travel of the
piston so that; if [A] is increased, [B] must be diminished and vice versa.
- Mount the piston on tail bracket [11] (see Fig. 5).
- Pull piston drive shaft [15] out to its full length and shorten it of approx. 20 mm (see dimension L of fig 10).
- When the gate is completely closed, position the head bracket in proximity to the attachment of the piston.
Check that head and tail brackets are perfectly level (see Fig. 6). Secure the head bracket to the gate.
- Secure the piston to the head bracket (see Fig. 7).
- Fitand secureshaftcover [13]onto thedriveshaft bymeans of thescrews provided(beforefitting, greasingof
the inside of the shaft cover with a thin film of grease is recommended).
- Release the piston (see operating instructions).
- Manually move the gate to check for free and smooth movement.
- Fit in the screw covering ring [14] and the plug (securing of plug to shaft cover by means of silicone gel is
advisable).
- Sealoffthetwotopholes[F]ofthehalfcasingbymeansofthetwoplugsprovided(orwithsiliconegel)(seeFig.3).
Attention: Check that the two bottom holes of the half-casing are not clogged thus preventing water to
drain off properly.
[5] electric board
[6] Gearedmotor
[7] Photocells
Degreeofprotection
Applications
Recommended
dimensions
forHEAVIDUTY
(servicelife =3)
Limit
dimensions
Powersupply
Absorption
Motor power
Geared motor torque
Jogging
Speed
SILVER 1B SILVER 40B
230 V~ 50 Hz 230 V~ 50 Hz
1.1 A 1.1 A
180 W 180 W
3000 N 3000 N
S2=15min,S3=25%
22 s / 90° 38 s / 90°
Temperature IP45
-15 °C / +50 °C
5
4
3
2
1
m
100 300 500
5
4
3
2
1
m
100 300 500
kg kg
[11] Tailbracket
[12] Head bracket
[13] Shaftcover
[14] Screwcoveringring
[15] Piston rod
[16] Plug
[4] Connectpower supply toantype-approved
omnipole switch with a contact opening
gap of no less that 3 mm (not supplied by
us)
ENGLISH

ENGLISH
TEAR OFF AND DELIVER TO USER
4.ELECTRICALCONNECTIONS
Drill a hole in cover [9] in correspondence with [E] (facing downwards) to route the cable (see Fig. 3).
Attention: Cable must be secured by means of a cable fitting (not supplied).
TheSILVER 1B/40Bgearedmotors canbe connectedto electricpanelsD1, D2,LOGICA21, LOGICA22.
Connect the geared motors SILVER 1B / 40B as shown in fig. 8 (1 wing) other in fig. 9 (2 wings).
5. MAINTENANCE PROGRAM (each 6 month)
Power off (230 V~ mains and batteries, if installed):
- Clean and lubricate the pivot pins.
- Check that fastening points are properly tightened.
Power on (230 V mains and batteries, if installed):
- Check the power adjustments.
- Check the operation of all command and safety functions (photocells).
- Check the good operation of the release.
ATTENTION: For spare parts, see the spares price list.
Electromechanicalautomatic system forswing gates.
RELEASEINSTRUCTION
Incase offaultyoperationor powerfailure,insert and
rotate the key clockwise. Unlock the electric lock, if
mounted.Manually slidethe gateopen.
To relock the wings, turn the key anticlockwise.
Attention: Lock and release operations must be
performed with motor not running.
DITEC S.p.A.
Via Mons. Banfi, 3
21042CaronnoP.lla(VA)Italy
Tel.+3902963911 - Fax+39029650314
www.ditec.it
Operating instruction SILVER 1B / 40B
GENERALSAFETYPRECAUTIONS
The following precautions are an integral and essential part of the product and must be supplied to the user. Read them carefully
as they contain important indications for the safe installation, use and maintenace. These instruction must be kept and forwarded
to all possible future user of the system. This product must be used only for that which it has been expressely designed. Any other use
is to be considered improper and therefore danger-
ous.
The manufacturer cannot be held responsible for
possible damage caused by improper, erroneous or
unresonable use. Avoid operating in the proximity of
the hinges or moving mechanical parts. Do not enter
the field of action of the motorised door or gate while
inmotion. Do notobstruct the motion ofthe motorised
door or gate as this may cause a situation of danger.
Do not allow children to play or stay within the field
of action of the motorised door or gate.
Keep remote control or any other control devices out of the reach of children, in order to avoid
possible involuntary activation of the motorised door or gate. In case of breack down or malfunc-
tioning of the product, disconnect from mains, do not attempt to repair or intervene directly and
contact only qualified personnel. Failure to comply with the above may create a situation of
danger.
All cleaning, maintenance or repair work must be carried out by qualified personnel.
In order to guarantee that the system works efficiently and correctly it is indispensable to comply
with the manufacturer’s indications thus having the periodic maintenance of the motorised door or
gate carried out by qualified personnel.
In particular regular checks are recommended in order to verify that the safety devices are operating correctly.
All installation, maintenance and repair work must be documented and made available to the user.
ISO 9001 - Cert. n° 0957/1
Installer:
ON
OFF

CARONNO P.LLA - VA
QUARTOD’ALTINO- VE
ISO9001
Cert. n° 0957/1
DITEC S.p.A.
Via Mons. Banfi, 3
21042CaronnoP.lla(VA)Italy
Tel.+39 02963911 -Fax+39 02 9650314
www.ditec.it





Table of contents
Other DITEC Fencing & Gate manuals
Popular Fencing & Gate manuals by other brands

Magnetic
Magnetic MHTM FlowMotion mWing operating instructions

Ansell
Ansell Tretight Installation, user, maintenance and dismantling manual

Betafence
Betafence Quixolid Plus installation manual

Dogtra
Dogtra E-Fence 3500 owner's manual

Parktron
Parktron AGT 210 user manual

Cardinal Gates
Cardinal Gates WG35 Assembly instructions