DMX Casambi SceneDMXcas User manual

SceneDMXcas USA & Canada
Casambi Scene Controller/Selector
DMX Engineering LLC
hp://dmx.engineering
Product Descripon
SceneDMXcas is a Casambi “Gateway” device designed to ulize a connecon to a stand-
ard DMX digital master controller to provide remote selecon of pre-dened Casambi
Scenes and Scene Intensity. SceneDMXcas is connected between a 12-24 VDC Class 2
power supply, and a DMX master universe.
SceneDMXcas decodes two DMX channels, and provides Scene selecons by mapping the
rst DMX channel to up to 20 pre-dened Casambi Scenes. The second DMX channel
provides 0-100% intensity selecon for the selected Casambi Scene. The DMX Start Ad-
dress for each SceneDMXcas is also user selectable.
SceneDMXcas can be congured with the Casambi app which can be downloaded free of
charge from Apple App Store and Google Play Store.
Dierent Casambi enabled products can be used from a simple one luminaire direct con-
trol to a complete and full featured light control system where up to 127 units form auto-
macally an intelligent mesh network.
Compable devices:
iPhone 4S or later
iPad 3 or later
iPod Touch 5th gen or later
Android 4.4 or later devices
produced aer 2013 with full
BT 4.0 support
Technical Data
Input
Voltage range: 12-24 VDC, Class 2
No-load input current: 30 mA
DMX-512 Input
3-wire non-isolated DMX-512
Channel 1—Scene selecon
Channel 2—Intensity level
Radio transceiver
Operang frequencies: 2.401-2.483 Ghz
Maximum output power: typ. +0 dBm, +/-3dBm
Operang condions
Ambient temperature, ta: -13...+113°F (-25...+45°C)
Max. case temperature, tc: +167°F (+75°C)
Storage temperature: -13...+167°F (-25...+75°C)
Max. relave humidity: 0...80%, non-cond.
Connectors
Wire range, solid & stranded: 0.5 - 1.5 mm2
14 - 22 AWG
Wire strip length: .25” (6 - 7 mm)
Tightening force: 0.4 Nm / 2.6 Lb-in
Dimensions: 2.2 x 1.2 x 0.7 inch
72.6 x 30.0 x 18.0 mm
Weight: 0.8 oz (23 g)
DMX Casambi Scene Selector
Cercaons
FCC ID: 2ALA3-CBM002A
IC: 22496-CBM002A
Conforms to UL STD 916
Cered to CSA STD C22.2#205
Typical Connecon Diagram
Mechanical Data
DMX Engineering LLC
9221 E. Baseline Road, Suite 109-492
Mesa, AZ 85209
DMX+
DMX-
RETURN
SceneDMXcas
dmx.engineering
INPUT 12-24 VDC, 30mA,
Use Class 2 power supply
+ -
Casambi enabled
Scene Controller
+ -
12-24VDC
Class 2
Power
Supply
DMX+
DMX-
Ground
**RATED FOR INDOOR USE ONLY**

Installaon
Connect a Class 2 power supply with 12-24 VDC output voltage to the input connector of Scene10cas. Make sure not to use a constant current LED
driver and make sure that the cable polarity is correct. The product has two DMX input connecons (+ and -), plus one common (RETURN) ground.
Connect the DMX in wires to a DMX master of your choice to give you DMX control of your Casambi Scene lighng network. Add Scenes to the
Casambi network, the SceneDMXcas will allow up to 20 Scenes to be selected.
Using the Casambi app, go to Gateways, and press on the SceneDMXcas device, and add it to your Casambi network. Now press on the
SceneDMXcas icon, and scroll to the boom of that screen. Note at the boom of this screen there are 21 user programmable parameters—DMX
Start Address, and 20 Scene selectors. First select your DMX Start Address, then up to 20 Scenes from your pre-dened Scenes in your Casambi
network. Now simply use your DMX master to select the Scene and Intensity, with the rst DMX channel selecng the Scene and the second chan-
nel dening the Intensity.
SceneDMXcas should not be placed in a metal enclosure, such as metal juncon boxes. Metal will aenuate radio signals which are crucial to the
operaon of the product. If the product will have to installed into a juncon box, make sure to use a plasc juncon box. SceneDMXcas is an ETL
Listed Open-Type device which means that it will have to be used together with a Class 2 power supply with maximum output power of 100 VA. The
product can be installed outside of juncon box. Make sure to comply with Naonal Electric Code in installaon and when selecng installaon
wires.
Range
The range between two SceneDMXcas’s or between a SceneDMXcas and a smart phone can vary depending on obstacles and surrounding material.
In open air the range between two SceneDMXcass can be in excess of 200 , but if the unit is encapsulated into a metal structure, the range can be
only few feet. Therefore, thorough tesng is high suggested.
Casambi uses mesh network technology so each SceneDMXcas acts also as a repeater. When tesng the network, it is important to test that each
unit can be controlled from any point of the network covered area.
Compliance Statement
This device complies with part 15 of the FCC Rules. Operaon is subject to the following two condions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operaon.
Warning
Changes or modicaons not expressly approved by DMX Engineering and Design LLC could void the user’s authority to operate the equipment.
FCC Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to pro-
vide reasonable protecon against harmful interference in a residenal installaon. This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instrucons, may cause harmful interference to radio communicaons. However, there is no guarantee that interference
will not occur in a parcular installaon. If this equipment does cause harmful interference to radio or television recepon, which can be determined by turning the
equipment o and on, the user is encouraged to try to correct the interference by one of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separaon between the equipment and receiver.
• Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Radiaon Exposure Statement for Canada
This device complies with Industry Canada’s licence-exempt RSSs. Operaon is subject to the following two condions:
(1) This device may not cause interference
(2) This device must accept any interference, including interference that may cause undesired operaon of the device.
This equipment is exempt from the roune RF exposure evaluaon requirements of RSS-102. This equipment should be installed and operated with a minimum dis-
tance of 20 cm between the antenna and the user or bystanders.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitaon est autorisée aux deux condions sui-
vantes:
(1) l’appareil ne doit pas produire de brouillage;
(2) l’ulisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est suscepble d’en compromere le fonconnement.
Informaon in this document is subject to change.
Copyright DMX Engineering LLC 2019-2020
SceneDMXcas User Guide v1.04 USA and Canada
DMX Engineering LLC
9221 E. Baseline Road, Suite 109-492
Mesa, AZ 85209
**RATED FOR INDOOR USE ONLY**
Other DMX Controllers manuals
Popular Controllers manuals by other brands

Siemens
Siemens RWB27 Timeswitch Installation and operating instructions

Projoy Electric
Projoy Electric PEFS-24V-CN Series user manual

Chino
Chino DB600 Series instruction manual

YASKAWA
YASKAWA U1000 iQpump Drive Quick start quide

Parker
Parker IQAN-LST Instruction book

SpeedyBee
SpeedyBee F405 WING APP user manual

FMS
FMS winderGLIDE BKS.D.6 Series installation manual

FASAR ELETTRONICA
FASAR ELETTRONICA FE230/T manual

Crestron
Crestron MC2W supplementary guide

Lightmaxx
Lightmaxx Multi Dimm MKII user manual

SSSR Labs
SSSR Labs SM800 Assembly manual

American Dynamics
American Dynamics ADTT16E Touch Tracker reference guide