SceneDMXcas USA & Canada
Casambi Scene Controller/Selector
DMX Engineering LLC
hp://dmx.engineering
Product Descripon
SceneDMXcas is a Casambi “Gateway” device designed to ulize a connecon to a stand-
ard DMX digital master controller to provide remote selecon of pre-dened Casambi
Scenes and Scene Intensity. SceneDMXcas is connected between a 12-24 VDC Class 2
power supply, and a DMX master universe.
SceneDMXcas decodes two DMX channels, and provides Scene selecons by mapping the
rst DMX channel to up to 20 pre-dened Casambi Scenes. The second DMX channel
provides 0-100% intensity selecon for the selected Casambi Scene. The DMX Start Ad-
dress for each SceneDMXcas is also user selectable.
SceneDMXcas can be congured with the Casambi app which can be downloaded free of
charge from Apple App Store and Google Play Store.
Dierent Casambi enabled products can be used from a simple one luminaire direct con-
trol to a complete and full featured light control system where up to 127 units form auto-
macally an intelligent mesh network.
Compable devices:
iPhone 4S or later
iPad 3 or later
iPod Touch 5th gen or later
Android 4.4 or later devices
produced aer 2013 with full
BT 4.0 support
Technical Data
Input
Voltage range: 12-24 VDC, Class 2
No-load input current: 30 mA
DMX-512 Input
3-wire non-isolated DMX-512
Channel 1—Scene selecon
Channel 2—Intensity level
Radio transceiver
Operang frequencies: 2.401-2.483 Ghz
Maximum output power: typ. +0 dBm, +/-3dBm
Operang condions
Ambient temperature, ta: -13...+113°F (-25...+45°C)
Max. case temperature, tc: +167°F (+75°C)
Storage temperature: -13...+167°F (-25...+75°C)
Max. relave humidity: 0...80%, non-cond.
Connectors
Wire range, solid & stranded: 0.5 - 1.5 mm2
14 - 22 AWG
Wire strip length: .25” (6 - 7 mm)
Tightening force: 0.4 Nm / 2.6 Lb-in
Dimensions: 2.2 x 1.2 x 0.7 inch
72.6 x 30.0 x 18.0 mm
Weight: 0.8 oz (23 g)
DMX Casambi Scene Selector
Cercaons
FCC ID: 2ALA3-CBM002A
IC: 22496-CBM002A
Conforms to UL STD 916
Cered to CSA STD C22.2#205
Typical Connecon Diagram
Mechanical Data
DMX Engineering LLC
9221 E. Baseline Road, Suite 109-492
Mesa, AZ 85209
DMX+
DMX-
RETURN
SceneDMXcas
dmx.engineering
INPUT 12-24 VDC, 30mA,
Use Class 2 power supply
+ -
Casambi enabled
Scene Controller
+ -
12-24VDC
Class 2
Power
Supply
DMX+
DMX-
Ground
**RATED FOR INDOOR USE ONLY**
Installaon
Connect a Class 2 power supply with 12-24 VDC output voltage to the input connector of Scene10cas. Make sure not to use a constant current LED
driver and make sure that the cable polarity is correct. The product has two DMX input connecons (+ and -), plus one common (RETURN) ground.
Connect the DMX in wires to a DMX master of your choice to give you DMX control of your Casambi Scene lighng network. Add Scenes to the
Casambi network, the SceneDMXcas will allow up to 20 Scenes to be selected.
Using the Casambi app, go to Gateways, and press on the SceneDMXcas device, and add it to your Casambi network. Now press on the
SceneDMXcas icon, and scroll to the boom of that screen. Note at the boom of this screen there are 21 user programmable parameters—DMX
Start Address, and 20 Scene selectors. First select your DMX Start Address, then up to 20 Scenes from your pre-dened Scenes in your Casambi
network. Now simply use your DMX master to select the Scene and Intensity, with the rst DMX channel selecng the Scene and the second chan-
nel dening the Intensity.
SceneDMXcas should not be placed in a metal enclosure, such as metal juncon boxes. Metal will aenuate radio signals which are crucial to the
operaon of the product. If the product will have to installed into a juncon box, make sure to use a plasc juncon box. SceneDMXcas is an ETL
Listed Open-Type device which means that it will have to be used together with a Class 2 power supply with maximum output power of 100 VA. The
product can be installed outside of juncon box. Make sure to comply with Naonal Electric Code in installaon and when selecng installaon
wires.
Range
The range between two SceneDMXcas’s or between a SceneDMXcas and a smart phone can vary depending on obstacles and surrounding material.
In open air the range between two SceneDMXcass can be in excess of 200 , but if the unit is encapsulated into a metal structure, the range can be
only few feet. Therefore, thorough tesng is high suggested.
Casambi uses mesh network technology so each SceneDMXcas acts also as a repeater. When tesng the network, it is important to test that each
unit can be controlled from any point of the network covered area.
Compliance Statement
This device complies with part 15 of the FCC Rules. Operaon is subject to the following two condions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operaon.
Warning
Changes or modicaons not expressly approved by DMX Engineering and Design LLC could void the user’s authority to operate the equipment.
FCC Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to pro-
vide reasonable protecon against harmful interference in a residenal installaon. This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instrucons, may cause harmful interference to radio communicaons. However, there is no guarantee that interference
will not occur in a parcular installaon. If this equipment does cause harmful interference to radio or television recepon, which can be determined by turning the
equipment o and on, the user is encouraged to try to correct the interference by one of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separaon between the equipment and receiver.
• Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Radiaon Exposure Statement for Canada
This device complies with Industry Canada’s licence-exempt RSSs. Operaon is subject to the following two condions:
(1) This device may not cause interference
(2) This device must accept any interference, including interference that may cause undesired operaon of the device.
This equipment is exempt from the roune RF exposure evaluaon requirements of RSS-102. This equipment should be installed and operated with a minimum dis-
tance of 20 cm between the antenna and the user or bystanders.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitaon est autorisée aux deux condions sui-
vantes:
(1) l’appareil ne doit pas produire de brouillage;
(2) l’ulisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est suscepble d’en compromere le fonconnement.
Informaon in this document is subject to change.
Copyright DMX Engineering LLC 2019-2020
SceneDMXcas User Guide v1.04 USA and Canada
DMX Engineering LLC
9221 E. Baseline Road, Suite 109-492
Mesa, AZ 85209
**RATED FOR INDOOR USE ONLY**

Other DMX Controllers manuals

DMX Scene10cas User manual

DMX

DMX Scene10cas User manual

DMX 99-3375 User manual

DMX

DMX 99-3375 User manual

Popular Controllers manuals by other brands

Koei Industry Nucom L50S Operation manual

Koei Industry

Koei Industry Nucom L50S Operation manual

Dresser RR 16 instruction manual

Dresser

Dresser RR 16 instruction manual

Parker HTR Series product manual

Parker

Parker HTR Series product manual

Elation PIXEL DRIVER 1000IP user manual

Elation

Elation PIXEL DRIVER 1000IP user manual

YGE OPTO 205 HVT quick start guide

YGE

YGE OPTO 205 HVT quick start guide

Drucegrove IND055 user manual

Drucegrove

Drucegrove IND055 user manual

Siemens RWB27 Timeswitch Installation and operating instructions

Siemens

Siemens RWB27 Timeswitch Installation and operating instructions

Projoy Electric PEFS-24V-CN Series user manual

Projoy Electric

Projoy Electric PEFS-24V-CN Series user manual

Chino DB600 Series instruction manual

Chino

Chino DB600 Series instruction manual

YASKAWA U1000 iQpump Drive Quick start quide

YASKAWA

YASKAWA U1000 iQpump Drive Quick start quide

Parker IQAN-LST Instruction book

Parker

Parker IQAN-LST Instruction book

SpeedyBee F405 WING APP user manual

SpeedyBee

SpeedyBee F405 WING APP user manual

FMS winderGLIDE BKS.D.6 Series installation manual

FMS

FMS winderGLIDE BKS.D.6 Series installation manual

FASAR ELETTRONICA FE230/T manual

FASAR ELETTRONICA

FASAR ELETTRONICA FE230/T manual

Crestron MC2W supplementary guide

Crestron

Crestron MC2W supplementary guide

Lightmaxx Multi Dimm MKII user manual

Lightmaxx

Lightmaxx Multi Dimm MKII user manual

SSSR Labs SM800 Assembly manual

SSSR Labs

SSSR Labs SM800 Assembly manual

American Dynamics ADTT16E Touch Tracker reference guide

American Dynamics

American Dynamics ADTT16E Touch Tracker reference guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.